Tender For Construction Of Sports Stadium At Village Andhli, Distt. Kaithal (C.M. Announcement Code No. 21026 Dated 22.05.2018), Kaithal-Haryana

Haryana Police Housing Corporation Limited has published Tender For Construction Of Sports Stadium At Village Andhli, Distt. Kaithal (C.M. Announcement Code No. 21026 Dated 22.05.2018). Submission Date for this Tender is 07-03-2024. Stadium Tenders in Kaithal Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42269775
Tender For Construction Of Sports Stadium At Village Andhli, Distt. Kaithal (C.M. Announcement Code No. 21026 Dated 22.05.2018)
Open Tender
Indian
Haryana
Kaithal
07-03-2024

Tender Details

Construction Of Sports Stadium At Village Andhli, Distt. Kaithal ( C.M. Announcement Code No. 21026 Dated 22.05.2018 )

Key Value

Document Fees
INR 20000 /-
EMD
INR 1002000.0 /-
Tender Value
INR 5.01 Crore /-

BOQ Items

Name of Work: Construction of Sports Stadium at Village Andhli, Distt. Kaithal (C.M. Announcement code No. 21026 dated 22.05.2018
Sl. No. Item Description
1HSR PART [10.1]Providing and laying of base course of floors consisting of 100 mm thickcement1:8:16and100mmsandor stone filling.
2[10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth.
3[10.29.4]Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 4. Ordinary cement without any pigment
4[10.30.4]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 4. Ordinary cement without any pigment
5[10.36]Brick on end in soil/edging in required pattern with bricks of class designation
6[10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick
7[10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
8[10.4]Providing and laying of screedof50mmthickcementconcrete 1:8:16 to be laid below the topping.
9[10.42]Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
10[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
11[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thickin skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade ofGranite including labour for fixing cramps pins and dowels etc.
12[10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
13[10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm
14[10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm
15[10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4
16[10.77]Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
17[10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4
18[10.82.6]Providing and fixing of P.V.C. sheet flexible type conforming to I.S.3462-1966 flooring plain coloured marble or mottled finish on a smooth damp proof base laid with adhesive recommended by manufacturer including pressing the sheet with a suitable tool to get a smooth surface all complete as directed by the Engineer-in-Charge. 6. 5.00 mm thick
19[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand)
20[11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand)
21[11.5.2]12 mm cement plaster of mix : 2. 1:3 (1 cement: 3 fine sand)
22[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)
23[11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand)
24[11.52]Cement rendering on plaster 1 mm thick
25[11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand)
26[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
27[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer
28[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer
29[11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
30[11.76]Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete.
31[11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc.
32[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.
33[11.84.1]Painting over the wooden/metal surface with aluminium paint of approved brand and manufacture to give an even shade . 1. Two or more coats on new work
34[11.92.1]Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade : 1. Two or more coats on new work
35[11.93.1]Finishing walls with water proofing cement paint of required shade : 1. New work (Two or more coats applied @ 3.84 kg/10 sqm)
36[11.98.1]Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
37[12.10.2.1]Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 2.1. Kiln seasoned and chemically treated Hollock wood 35 mm thick
38[12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm
39[12.102.3]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 75 mm
40[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fastenersto be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
41[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
42[12.89]Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
43[12.9.7.1]Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 7.1. Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm).
44[12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm
45[12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm
46[12.99.1]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 300x10 mm
47[12.99.2]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm
48[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
49[13.3.1.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb
50[13.3.2.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.1. Profile C Fixing with adjustable lugs with split end tail to each jamb
51[14.1]Dressing bed and preparation of sub grade for lining by mechanical/ mannual means
52[15.26.1]Sand Filling and Water Filling of Wells 1. Sand Filling in Wells complete as per Drawing and Technical Specifications MORT&H clause 1207
53[17.14.3]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 3. Grading III material
54[17.15.1]Granular Sub-Base with CoarseGraded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 1. Grading I material
55[17.23.2]Water Bound Macadam Grading - II 2. Water Bound Macadam - II with Screening Type A / Type B Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications
56[17.44]Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing, as per clause 601 of MORT&H specifications
57[17.5.3]Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications
58[20.114.4]Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 4. 25 HP Motor
59[20.124.36]Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of IS 8034-1989 and Clause 4.1 of IS 9283-1979. 36. LPM 850 Head 90 BHP 28.33 Say Round BHP 30.00
60[20.24.6]Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections 6. Ferrule size 40 mm
61[20.25.1]Cutting holes up to 23 cm square through brick work in mud walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall
62[20.25.2]Cutting holes up to 23 cm square through brick work in mud walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall
63[20.54.3]Providing GI pipes class B marked with IS: 1239 in 3.05 m length, their threading and welding with flanges (Heavy Duty) on both sides, jointing with nuts and bolts ( ‘W’ make), rubber gaskets , lowering into Tube wells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. 3. 80 mm i/d
64[20.56.2]Providing and screwing in brass/Gun Metal ferrules drilling and tapping Cast Iron /D.I. /G.I. pipe lines of all diameters and connections including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (Excavation will be paid separately). 2. 10mm i/d ferrule
65[20.62.3]Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 3. 300 mm i/d
66[20.63.1]`Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. ` 1. 100 mm i/d
67[20.63.2]`Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. ` 2. 150 mm i/d
68[20.68.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia
69[20.76.6]Design, Supply and erection of transformer of standard make Required 25 KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity. 6. 150 KVA
70[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects.
71[20.88]Supply, erection, testing and commissioning of CT meter of standard make with cubical meter box as per HVPNL specifications including 3 phase electrical meter 100/5 of standard make approved by HVPNL including CT/PT of suitable rating complete in all respect as per directions of Engineer-in-charge
72[20.97]Supplying, fixing and lowering reducing socket as per IS:226 as amended up to date 273.10mm outer dia, x 219.10mm outer dia with 8 threads per inch or 25.40mm to be made out of M.S. plate with internal threads, suitable for jointing 273.10mm outer dia pipe andouter dia pipe and 219.10mm outer dia ERW pipe
73[21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping
74[21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab)
75[22.10.2.1]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 2.1. Kitchen sink without drain board 610x510 mm bowl depth 200 mm
76[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore
77[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore
78[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore
79[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore
80[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
81[22.128.2]Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 2. 15 mm nominal bore with 45 cm length
82[22.162.1.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 1.1. 100 mm diameter Class I
83[22.162.3.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 3.1. 150 mm diameter Class I
84[22.163.1]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 1. 100 mm diameter
85[22.163.2]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2. 150 mm diameter
86[22.164.1]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 1. 100 mm diameter S.W. pipe
87[22.164.2]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 2. 150 mm diameter S.W. pipe
88[22.166.1.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5
89[22.173.1]Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5
90[22.174.1]Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5
91[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
92[22.212.1.2]Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. 1.2. C.P Brass Two Way
93[22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
94[22.221.9]Providing and fixingin position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval)
95[22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete
96[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete
97[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete
98[22.24.1]Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 1. W.C. pan with ISI marked white solid plastic seat and lid
99[22.26.3]Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 3. Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
100[22.35]Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
101[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
102[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass
103[22.44]Providing and fixing 32 mm diameter Gl. extension pipe for Indian type Water Closet suite complete with accessories(as approved by the Engineer -in-charge)
104[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes
105[22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 6. 50 mm nominal outer dia Pipes
106[22.88.4]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 4. 32 mm dia nominal bore
107[22.88.5]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 5. 40 mm dia nominal bore
108[22.90]Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc.
109[22.94.2]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 2. 20 mm nominal bore
110[22.94.3]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 3. 25 mm nominal bore
111[22.94.4]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 4. 32 mm nominal bore
112[22.94.5]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 5. 40 mm nominal bore
113[22.95]Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
114[22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore
115[22.98.2]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore
116[22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore.
117[22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore
118[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
119[23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA
120[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
121[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
122[23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door8 way ( 8 incoming 3phase*8 outgoing)
123[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DBHorizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
124[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
125[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE
126[23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE
127[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
128[23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosureof following Ratings200 amp 415 volts
129[23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required
130[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
131[23.27.1]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof .The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level.0 0
132[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
133[23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)
134[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)
135[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etcin 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A
136[23.4.1.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etcin 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B
137[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVCconduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A
138[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A
139[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
140[23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules
141[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
142[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
143[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
144[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
145[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but withoutcharcoal or coke and salt) etc. complete as required.
146[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
147[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
148[24.4.15.2]STREET LIGHT 15.2. B.S.E.N. 10025 High Masts "Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top and Bottom Section = 3 mm & 4mm (minimum) Top Dia = 150 mm and Bottom Dia = 410mm Thickness of Galvanization - Top = 65 micron (minimum) andBottom = 85 micron (minimum)"
149[24.4.7.2]STREET LIGHT 7.2. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia
150[24.4.8.3]STREET LIGHT 8.3. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 5 Metre Long pole with top dia 65 mm and bottom dia 130mm with base plate of size 250 x 250 x 16 mm
151[24.4.8.7]STREET LIGHT 8.7. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 350 x 350 x 20 mm.
152[24.5.1.4]MISCELLANEOUS ITEMS 1.4. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 6 sqmm
153[24.5.1.5]MISCELLANEOUS ITEMS 1.5. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 10 sqmm
154[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
155[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia
156[24.9.2]RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES 2. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 16m high mast pole
157[26.2]Supplying and stacking of goodquality top layer gardenearth free from debris and weeds,at site including royalty and carriage/lead5 km (good earth measured in stacks will be reduced by 20 % for payment) only for filling of pots and flowerbeds .0.00 0.00 0.00
158[26.9.4]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per100 sqm, maintenance till weed free turf is formed 4. Providing and fixing Selection no. 1 grass turf with earth 50mm to 60mm thickness and ramming with required wooden tools, rolling with light roller to make the surface smooth and even
159[28.43]Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) ) 78, solar reflection ) 0.70 and initial emittance ) 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
160[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Modulemanufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hzplus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp
161[33.10.3]Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed and approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer-in-charge. 3. 200 mm nominal size dia having minimum wall thickness 5.40 mm
162[33.12]Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
163[33.14]Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge.
164[33.15]Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
165[33.16.3]Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia
166[33.17.3]Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 3. 200 mm clamp
167[33.18.3]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 3. 200 mm dia
168[33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge.
169[33.6.1.1]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.1. All types of soil 300 mm dia
170[33.8.2]Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 2. 150 mm nominal size dia
171[33.9.2]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 2. 150 mm nominal size dia
172[34.24.2]Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control 2. Up to 10 cm in width
173[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil
174[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil.
175[4.16.1.2]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.2. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
176[4.2]Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
177[4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil
178[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
179[4.8.1]Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m : 1. All kinds of soil
180[6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
181[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
182[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
183[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
184[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
185[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
186[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
187[6.21]Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size).
188[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete
189[6.30.13]Centering and shuttering including strutting, propping etc. and removal of form for 13. Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
190[6.30.14]Centering and shuttering including strutting, propping etc. and removal of form for 14. Extra for shuttering in circular work (20% of respective centering and shuttering items)
191[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform
192[6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ)
193[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
194[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts
195[6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases
196[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.
197[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.
198[6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
199[6.8.1]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 1. 50 mm thick
200[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)
201[7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand)
202[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand)
203[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand)
204[7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
205[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase
206[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
207[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter
208[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter
209[9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend
210[9.58.5.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend
211NS PART Providing and fixing CP Jali with frame complete in all respect
212Providing & fixing CP brass flange complete
213Providing & fixing SWR PVC pipe clip/ clamp 90mm dia
214Providing & fixing SWR PVC Vent cowl with Jali 90mm dia
215Providing & fixing SWR PVC Coupler/ Socket 90mm dia
216Providing & fixing SWR PVC Bend with Door 90mm dia
217Providing & fixing SWR PVC Nanhi trap with Jali(110x110mm)
218Providing & fixing SWR PVC Vent cowl with Jali 110mm dia
219Providing & fixing SWR PVC pipe clip/ clamp 110mm dia
220Providing & fixing SWR PVC Coupler/ Socket 110mm dia
221Providing & fixing SWR PVC Bend with Door 110mm dia
222Providing & fixing SWR PVC P-Trap(DS) 110 x 110mm
223Providing and Fixing of Co-polymer based rainwater harvesting structure including supply of crosswave of size 494 mm x 494 mm x220mm with minimum void ratio of 94.7% having a weight of 1.8 kgand spacers having size of 988 mm x 240 mm x 25 mm having a weightof 0.8 kg of approved make and arranging the same in as directed by the engineer-in-charge and in complete accordance to the design, drawings as per entire satisfaction of Engineer -in-charge
224Providing and fixing of non woven Geotextile having thickness of 400 gsm, having minimun tear Strength of 250 ASTM D4533, width wise at least 215 ASTM D4533 having puncture strength of 1550 plus as per ASTM D6241 Having elongation at Break % of 57 plus as per ASTM D 4595 in Two layers, made out of long fibers to hold the modules including cutting, sizing, heat welding and needle punched for high porosity and proper percolation. Complete as per entire satisfaction of engineer-in-charge
225Providing and fixing of CGWB/GRIHA approved Pure Rain Filters with extensions as required desilting suspended solid catcher made out of FRP and strainers including bucket of SS 304 grade with long fiber foam size around 600mm dia, filtration capacity 40 kiloliters per hour with porosity of 600 microns filter complete in accordance to the desgin , drawing and specification complete as per entire satisfaction of Engineer-in-Charge. Size of FIlter 780 mm Dia, 800 mm height
226Supplying and fixing of 300 mm supreme UPVC Pipe 315mm O/D conforming toI.S 4985-81 Dated-12/12/2013,I.S marked having 6 KG per centimeter square Pressure i.e. excavation, refilling for providing proper loop from catch pit to filter /filter to cross wave as per entire satisfaction of Engineer in charge.(from chamber to Filter to tank)
227Providing and Fixing of Medium Duty SFRC cover of required size with perforated slots over gully chamber. All as per requirementsand direction of Engineer-in-charge
228Providing and fixing in position 5mm thick looking mirror bevelled on sides fixing in position with necessary C.P. screw and washer complete
229Providing and fixing SWR PVC Single T With door90mm dia
230Providing and fixing SWR PVC Single T With door 110mm dia
231Providing and fixing SWR PVC Single T 110mm dia
232Earth filling with earth brought from outside the campus, irrespective of any lead, including laying in 15cm in layers, watering and consolidating complete in all respect and fully satisfaction of Engineer-in-charge (Based on HSR 2021).
233Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron `Y` shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
234Cutting chase in brick/ concrete wall for providing skirting flush with plaster
235Providing and fixing aluminium Eye hook (powder coated) for door and windows shutter with stainless steel or CP brass screws of required size complete
236Providing and fixing aluminium Folding Handle 100mm (powder coated) for door and windows shutter with stainless steel or CP brass screws of required size complete
237Providing and Fixing 25mm thick finished red sand stone both sides slightly rounded for partition and shelves in CB.
238Providing and fixing MS rod 8mm fully threadedwith nut bolts and washer inserted in aluminium sections, window and door shutters complete in all respect
239Extra for making hole in working slab for gas pipe/ stair railing etc.i/c finishing complete
240Providing and fixing acrylic sheet 4mm thick complete in all respect
241Making corbelling with CC 1:1.1/2:3 with stone aggregate 20mm thick nominal size i/c shuttering
242Providing and fixing zinc coated clamp i/c cost of 12mm screwed GI rod and fastener complete in all respect having dia 110mm/90mm
243Extra on account of labour for plaster work for cornice RCC/ brick work in facias parapets of various building in any design and any height complete in all respect
244Curtain Rod 25 mm of S.S. with 304 grade all Material Wall to wall Latoo complete in all respect
245Providing and fixing CPVC ball valve/ gate valve (union type) with of approved quality complete in all respect25mm dia
246Providing and fixing CPVC ball valve/ gate valve (union type) with of approved quality complete in all respect40mm dia
247Providing and fixing 25mm CPVC Tank Connector / Tank Nipple complete in all respect
248Providing and fixing 32mm CPVC Tank Connector / Tank Nipple complete in all respect
249Providing and fixing SWR PVC Single T 90mm dia
250Grouting the joints of flooring tiles having joints of 5mm width, using epoxy grout mix of 0.70kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting, 5mm dia backer rod and finishing for heat resistant tiles complete as per direction of Engineer-In-Charge (Derived rate based on HSR 10.70) Size 300mm x 300mm Heat Resistant Tiles
251Providing and Fixing aluminium fittings (powder coated) for door and windows shutters with stainless steel or C.P brass screws of required size complete. Sliding bolt 200 x 16mm
252Providing and Fixing aluminium fittings (powder coated) for door and windows shutters with stainless steel or C.P brass screws of required size complete. Sliding bolt 150 x 12mm
253Providing and fixing 25mm dia CPVC union complete in all respect
254`Providing and fixing CPVC union of approved quality complete in all respect i) 20mm dia`
255`Providing and fixing CPVC union of approved quality complete in all respect iii) 32mm dia
256`Providing and fixing CPVC union of approved quality complete in all respect iii) 40mm dia
257Drilling 685.8 mm dia bore by reverse rotatry/ DTH/ Precussion RIG according to ISI specifications no. ISI 2800-1991 as amended up to date in all classess of soil. Boulder upto 125 mm dia except rockey, includes the cost of all consumbles stores fuiel oil soil stablishing material and transportation of rig and other accessorries to the site of the work and back, drillling upto the 100 mm depth from ground level.
258P/I of electrically driven diaphragm metering dozing pump for injecting chlorine solution into the pipe line of AMS or any other reputed make complete in all respects including making connection to the pipe line.
259S/L 217.50 mm outer dia S/S screen as per IS: 8110:2000 of 6.3 mm thick in 3.20 M lengths /short length as per site requirement and with design of slots as per ISI specifications screwed and socketed with sockets of S/S for jointing the slotted lengths and blind ERW steel pipes oin suitable length to the satisfaction of the Engineer In-charge.
260Resistivity survey with deep penetration, generator operated, D.C. resistivity meter to know the type of sub surface strata at diferent depth of tube well to be installed to obtain potable water, including transportation of equipments and man power site.
261Providing and fixing complete basket ball set (Make Anera or equivalent) Specifications:- a) Pole made of 200mm M.S. pipe with 3.2 mtr. Extension. The extension is supoorted with scissors type double support at bottom to prevent jurk and special sport of plate at back for dunking ring. b) Basket ball board made of imported acrylic 1.80x1.05x25mm size all corners are covered with angle iron frame and with all marking on board. c) Dunking ring is made of 20mm solid rod with 3 spring mechanism and special designed hooks for net hanging and special shock pad will be provided to stop jurk while drunk d) Net heavy duty will be provided e) 8 back supports will be provided to support board from all and corners from pole f) complete set with all Nuts and bolts
262Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
263Supply and Erectionof Plastic Body Ornamental Exhaust Fan heavy duty 230V A.C 50 cycles, 300 mm sweep, 1300 rpm, energy efficient, complete erected in position with all accessories.
264Extra for grouting the joints of floor tiles having joints of 4 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 800x800mm
265Providing and fixing SWR Pipe clip/ Clamp 160mm dia
266Providing and fixing SWR Coupler/ Socket 160mm dia
267Providing and fixing SWR PVC Bend with Door 160mm dia
268Providing and fixing SWR PVC Single T with Door 160mm dia
269Supply and Erection of LT aluminum under ground cable loose in existing pipe or trenches including necessary connection,digging and refilling of trenches. (i) 185 Sq. mm 3.5 Core Cable . (Armoured)
270Supply and erection of LT aluminum under ground cable ,loose in existing pipe or trenches complete with necessary connections. (i) 95 Sqmm 3.5 Core cable (armoured)
271Supply and erection of LT aluminum under ground cable ,loose in existing pipe or trenches complete with necessary connections. (i) 70 Sqmm 3.5 Core cable (armoured)
272Supply and erection of LT aluminum under ground cable ,loose in existing pipe or trenches complete with necessary connections. (i) 25 Sqmm 4 Core cable (armoured)
273Supply and Erection of factory wired integral LED flood light luminaries with die cast aluminium housing built with driver set suitable for 80 to 90 watt. Confirming to IP 66 protection complete in all respect
274Supply and erection of LT aluminum under ground cable ,loose in existing pipe or trenches complete with necessary connections. (i) 300 Sqmm 3.5 Core cable (armoured)
275Supply, Installation, Testing and Commissioning of 5 MP Bullet VF Camera with 100 mtr IR, with below mentioned minimum features: Type of Camera: Bullet Image Sensor:1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @ 20fps or better Minimum Illumination:0.05 Lux or better, F 1.6 or better Video Compression (Minimum):H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording :Including internal or external Mic IR: 100 mtr. or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure:IP67, IK10 Standards: BIS,UL/CE/FCC Power: PoE Reset Button :Required Lens Type: 7~35mm Motorized Lens or better or Equivalent to achieve 120mtr IR distance Lens :F 1.6 or better Signal-to-Noise Ratio:50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition:0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Feature: Defog, BLC,HLC Video Analytics: Motion Detection, Tampering, People Counting Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes
276Supply and erection of LT aluminum under ground cable ,loose in existing pipe or trenches complete with necessary connections. (i) 50 Sqmm 4 Core cable (armoured)
277Supply, Installation, Testing and Commissioning of Speaker Cable with the following specifications: 1.5 Sqmm (48/0.20mm) x 2 core cable. The cable should have an ATC copper conductor and PVC insulation. The cores should be twisted together, and the cable should have an outer jacket with a PVC sheath. This speaker cable should be designed to provide reliable and high-quality audio signal transmission. The 1.5 Sqmm size ensures sufficient current carrying capacity, while the ATC copper conductor offers excellent conductivity. The PVC insulation provides electrical insulation and protection. The twisted cores help to minimize interference and crosstalk, ensuring clear audio transmission. The cable should have finished with an outer jacket featuring a PVC sheath, which adds durability and protects against external factors.
278Supply, Installation, Testing and Commissioning of a 15-meter HDMI Active Optical Cable with the following specifications: The cable should support 4K60 4:4:4 18Gbps bandwidth, ensuring high-quality video transmission with vivid colors and clear details. It should be Plenum rated and have a small diameter, making it suitable for installation in plenum spaces and ensuring easy cable management. The cable`s video compliance should include HDMI 2.0, HDCP 2.3, and HDR, ensuring compatibility with the latest HDMI standards and technologies. The cable should utilize active circuitry in the permanent HDMI connectors, allowing for reliable and robust HDMI signal transmission over long distances. It should support HDMI signals with video resolutions up to 4K@60Hz (18.0Gbps), providing smooth and high-definition video playback. This 15-meter HDMI Active Optical Cable shall be designed to provide a reliable and high-performance solution for extending HDMI connections over long distances while maintaining excellent video and audio quality. Its advanced features and specifications make it suitable for various audiovisual applications, such as home theater setups, professional AV installations, and multimedia presentations.
279Supply, Installation, Testing and Commissioning of a 10-meter HDMI Active Optical Cable with the following specifications: The cable should support 4K60 4:4:4 18Gbps bandwidth, ensuring high-quality video transmission with vivid colors and clear details. It should be Plenum rated and have a small diameter, making it suitable for installation in plenum spaces and ensuring easy cable management. The cable`s video compliance should include HDMI 2.0, HDCP 2.3, and HDR, ensuring compatibility with the latest HDMI standards and technologies. The cable should utilize active circuitry in the permanent HDMI connectors, allowing for reliable and robust HDMI signal transmission over long distances. It should support HDMI signals with video resolutions up to 4K@60Hz (18.0Gbps), providing smooth and high-definition video playback. This 10-meter HDMI Active Optical Cable shall be designed to provide a reliable and high-performance solution for extending HDMI connections over long distances while maintaining excellent video and audio quality. Its advanced features and specifications make it suitable for various audiovisual applications, such as home theater setups, professional AV installations, and multimedia presentations.
280Supply,Installation, Testing and Commissioning of various types of bulk connectors as per site requirements, including XLR Male, XLR Female, AUX, RCA, RJ-45, Velcro Tape, Cable ties, USB Cable and more. These connectors will cater to different audio, video, and data connectivity needs, providing flexibility and versatility in the setup. (For Seminar Halls)
281Supplying and Fixing of Floor Standing Network Rack - 22U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top and Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capacity of 500Kgs. Side Panels - 22U/800d Front MS Door perforated honeycomb 22U/600w Rear MS Door (Fully Perforated - Mesh) 22U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 22U complete in all respect.
282Providing and fixing CPVC ball valve/ gate valve (union type) with of approved quality complete in all respect 32mm dia
283Providing and fixing CPVC ball valve/ gate valve (union type) with of approved quality complete in all respect 50mm dia
284Supply and erection of LED flood light 200 watt white colour, pressure diecast, working hour minimum 35000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc
285SITC of All-Weather Compact 2-Way Coaxial Loudspeaker with 1 x 12` - 15` or more LF Driver: Shouldhave Highly weather-resistant IP56 rating: Coverage : 90x90deg ormore: Components: 300 mm (12 in) ormore woofer with Kevlar-reinforced cone and 75 mm (3 in) voice coil ,25 mm (1 in) exit compression driver: Should support overload protection: Frequency Range (-10 dB) : 56Hz–19kHz orbetter: Frequency Response (±3 dB) : 82Hz–19kHz orbetter: Long-Term 100hrs System Power Rating (pk): 1000W or more: Sensitivity (2.83V @ 1m): 96dB ormore: Maximum SPL (pk): 128dB ormore: Should support Transformer Taps (70V/100V): Minimum three power tapping including 200W (Max.): Enclosure: ABS with Glass enclosure: Attachment: Two M10: Grille: Corrosion-resistant zinc-rich extra-thick powder coated steel grille, 3-layer assembly with foam and woven poly mesh backing: Input Connection: CE-compliant covered barrier strip terminals: Environmental: IP56 per IEC529 or better: etc.
286SITC of All-Weather Compact Low Frequency Subwoofer Unit with 1 x 15` - 18` or more Driver: Shouldhave Highly weather-resistant IP56 rating: Components:380 mm (15 in) ormore woofer with Kevlar-reinforced cone and 75 mm (3 in) voice coil: Frequency Range (-10 dB) : 46Hz–2kHz orbetter: Frequency Response (±3 dB) : 71Hz–1.2kHz orbetter: Long-Term 100hrs System Power Rating (pk): 1400W or more: Sensitivity (2.83V @ 1m): 94dB ormore: Maximum SPL (pk): 127dB ormore: Should support Transformer Taps (70V/100V): Minimum three power tapping including 200W (Max.): Enclosure: ABS with Glass enclosure: Attachment: Two M10: Grille: Corrosion-resistant zinc-rich extra-thick powder coated steel grille, 3-layer assembly with foam and woven poly mesh backing: Input Connection: CE-compliant covered barrier strip terminals: Environmental: IP56 per IEC529 or better: etc.
287SITC of Two Way 8.0inch - 10.0inch LF, Compact Wall Loudspeaker for indoor and outdoor uses with Frequency Range 47Hz–19kHz ormore: Power rating 90Watts - 100Watts Continuous or more: Max SPL (pk) 118dB or better: Should have 70/100V Transformer taps 60W, 30W, 15W ormore: 100-120 degree (H) x100-120 degree (V) orbetter coverage: etc.
288SITC of Networked Digital Signal Processor with 12 or more inputs and 8 or more outputs or more: 12 or more Control Inputs and 6 or more Logic Outputs for GPIO Integration: 48V phantom power on all analog inputs: THD: (0.01% 20Hz to 20KHz: Crosstalk: (-75dB or better: Open architecture software configurable: Separate logic processing power: 2 digital audio bus RJ45 Port: 1 Ethernet port for Monitoring and configuration: Capable to handleplus 5V unloaded logic output voltage: Should have speech sense engine: Capable to control 3rd party devices with TCP IP and RS232: Should have 1nos of RS 232 port for integration with control System: Should have Bi-Directional Locate Functionality: Should have 48 or more digital audio Channel Bus: Should have monitoring LED for COM, STAT, ERR and PWR: etc.
289SITC of Mixing Console with 22 channels or more analog inputs and outputs and USB Interface: shall have Ghost Preamps : 16 , Sapphyre EQ: 4-band (2 bands of swept mids), Limiters on inputs :8 , Dual Engine effects , USB Interface 2-in/2-out  ,5 Auxes, 4 mono/2 stereo subgroups , 100mm faders: etc.
290SITC of Wireless Handheld Microphone System with MHzcarrier frequency band, Up to 16 ormore pre-programmed frequencies within the same frequency band: Audio bandwidth 35-20000Hz orbetter: THD at 1 kHz: (0.3%(Receiver): Signal-to-noise: 120 dB(A)( Receiver): Wideband FM Modulation: Up to 48 ormore Simultaneous channels: Upto 14 or more hours operation with one single AA battery or better: Pilot Tone transmission to know the transmitter battery status: Receivershould have microphone level and line level output: Transmitter should have display to show the battery and LED to show the Muted /Unmuted status: Sensitivity 6.3 dB V / -100 dBm orbetter: Should have Microprocessor-controlled diversity: T.H.D. 0.7% or better (Transmitter): Infrared programmable: RF output power: 50mW ormore: etc.
291SITC of Wireless Lavalier and Headworn Microphone System with MHzcarrier frequency band, Up to 16 ormore pre-programmed frequencies within the same frequency band: Audio bandwidth 35-20000Hz orbetter: THD at 1 kHz: (0.3%(Receiver): Signal-to-noise: 120 dB(A)( Receiver): Wideband FM Modulation: Up to 48 or more Simultaneous channels: Upto 14 or more hours operation with one single AA battery or better: Pilot Tone transmission to know the transmitter battery status: Receiver should have microphone level and line level output: Transmitter should have display to show the battery and LED to show the Muted /Unmuted status: Sensitivity 6.3dB V / -100 dBm orbetter: Should have Microprocessor-controlled diversity: T.H.D. 0.7 % or more (Transmitter): Infrared programmable: RF output power: 50mW or more: etc.
292SITC of wired Vocal microphone Should be Professional Dynamic Handheld Microphone and On/Off Switch: should support Polar Pattern supercardioid orbetter Audio Frequency bandwidth 70 to 20000Hz ormore: Sensitivity 2.6 mV/Pa or better: Electrical Impedance : 600 Ohms or better: Recommended Load Impedance : 2000 Ohms or more: Connector Type : 3-pin XLR Male (Balanced):Metal Body: etc
293Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres
294Providing and installation of aluminum Hand ball goal post of STAG make or equivalent with back support, portable-HP 2 dimension size 3x2mtr. of 80mm square aluminum pipe of thickness 2.8mm, wheel size 125mm, PU wheel with bearing 2mm thick nylon type net complete in all respect
295Supply and installation of Volley ball of STAG make of equivalent TELESCOPIC Arcle code: VBPO 10 Polie diameter, 75mm wall size, 4mm height adjustable, 2to 2.55 mtr. of MS steel with jack system including nylong type net spartan approved by volley ball federation of international standards complete in all respect
296Supplying and installation of Football goal post used in ISL and FIFA under 17 of STAG make or equivalent fixed with sleeeves, measuring 7.31x2.44 mtr., 120mm diameter aluminium pipe of thickness 3.50mm, back support 60mm round, 3mm thick having height of 10 ft (8ft above ground level) of GI pipe, net clips and goal post net of 2mm thickness nylon material complete in all respect
297Supplying and installation of Hockey goal post 75x50mm diameter, 2mm thick of NSE GRANDE brand or equivalent including double thickness of nylon net, back support with 25mm thick board complete in all respect
298Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : (DSR 2022/ 18.16.2) Stainless Steel (Grade 304).
299Supply and erection of LED flood light 100 watt with SPD white colour, pressure diecast, CCT 5700 K, power factor greater than 0.90 and working hour minimum 50000 hours, with IP66 rating operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc.
300Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia.
301Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :7.7)100 mm dia.
302Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating withronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : (DSR 2022/18.11.4) 80 MM Dia.
303Supplying, installation, testing and commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain and hammer assembly complete with glass and push button etc. as required. (DSR 2022/ 17.1.3).
304Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : (19.1) 2 way-100 mm dia M.S. Pipe.
305Providing and fixing in position the industrial type pressure gauges with gun metal/ brass valves complete as required.
306Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : (9.1) Single headed Gunmetal.
307(a) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. (c) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. (d) M.S. fabricated common base plate, coupling, coupling gaurd, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head.
308SITC of Powered Stage Monitor with Minimum 15” Should support Power Rating (pk): 1500W - 1800W ormore: Max SPL Output : 131dB - 133dB ormore: Frequency Response (±10 dB) : 31Hz-150kHz orbetter: etc..
309SITC Of Two-channel, 300W @ 4? Analog Power Amplifier, 70V/100V , 300 W x 2 channels at 4 and 8 ohms/100V/70V or better, Voltage Gain :34dB , Frequency Response 20 Hz - 20 kHz (at 1 W ), Signal-to-Noise RatioAnalog Input : 104 dB ,Damping Factor :) 1000, Input Impedance 20 kO balanced, 10 kO unblanced, Should have Integrated 8 band EQ , Limiter , Crossover and Delay
310Supply and erection of Air circulators wall fan of size 600 mm sweep heavy duty, suitable for single phase A.C. 230 Volts, 50 HZ supply, complete in all respect.
311Supply and Erection of surface mounting LED Batten fitting 1 x 18/20 watt (4` long), white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc
312Supply and erection of LED flood light 70 watt, suitable for operation on 230 volt ±5%, 50 HZ AC supply complete in all respect including all petty material, labour and making necessary connection etc.
313Providing and fixing 6 Kgs capacity ABC stored pressure type ISI marked fire extinguisher IS:15683 with 90% MAP powder complete in all respect with the entire satisfaction of Engineer-In-charge. (Make:Omex/Lifeguard/ Safex).
314Fabrication, supply, Installation , testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 5.1 INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Voltmeter 0- 500V with selector switch Digital Ammeter (0-250 A) with selector switch and CTs etc. LED type RYB phase indicating lamps, ON, OFF, preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/ manual/ OFF operation.
315Supply and Erection of hose box double door(750*600*250 mm) suitable for 2 No. hose pipe 15 meter, 1 No. short branch pipe complete in all respect
316Supply and erection of Fire Extinguisher ISI marked CO2 type of 4.5 Kg capacity as per IS :7285 duly erected/ hags on wall with hooks i/c the cost of hook, screws etc. with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in Charge of the work
317S.I.T.C. of Auto Glow Exit Signs and indication signs of Size 12” x 4” and Attack Fire, DP indication every exit point, Fire Point, Fire Extinguisher complete in all respect
318Supply and erection of water cooler SP body with 150 ltr /hr cooling and 150 ltr storage capacity complete in all respect including all labour and petty material.
319Supply and erection of 25 Liters commercial RO plus UV, Fully automatic with auto cut off RO plus UV Water Purification system 25 liter/ hr. capacity complete with all labor and petty material required including making necessary connections up to entire satisfaction of Engineering-Charge of the work.
320Supply, Installation, Testing and Commissioning of online UPS (2KVA) with 4 Hours battery backup 1. Technology Microprocessor Controlled, Double Conversion, PWM IGBT Inverter with LCD Display for UPS status monitoring 2. Isolation NA 3. Input Voltage Range 160-270 VAC on full load 4. Input Power Factor )0.99 5. Input Frequency 45-55Hz 6. Out Put Voltage Single Phase 230 plus /-1%, 50Hz 7. Output Power Factor 0.8 8. Frequency 50Hz plus /-0.5% 9. Efficiency )85% 10. Wave Form Pure Sine wave 11. Total Harmonic Distortion (THD) (3% for linear load, (6% nonlinear load 12. Overload Capacity overload capacity upto 125% for 60 sec 13. Back up Time 4 Hr back up 14. Battery, Backup and with Battery Rack SMF Batteries with Minimum of 4 hr. With a Battery rack with a suitable inbuilt charger 17. Protections Low Battery, overload, over temperature, short circuit 18. Operating Temperature 0-40’C 19. Optional RS 232/USB, SNMP Compatibility 20. Noise: (50dB up to 1 meter 21. SNMP Port: Yes 22. Product Quality Standard and certification ISO 9001:2008, 14001:2004, CE, ROHS45001, 50001, 14025 and BIS Certification 23. Compatibility DG Set `
321Supply, installation, testing and commissioning of 1.5 TR,5 star, Inverter type, Wall mount `Split Air-conditioning unit `, single phase consisting of condensing indoor unit, outdoor unit of copper coil, MS stand, copper wound digital stabilizer 4 KVA , 160V -270V , copper refrigrant piping and cabling between indoor and outdoor unitupto 3 meter etc., complete in all respecti/c making repair of wall,floor and roof in origional shape caused by making holes and chases etc.
322SITC of Commercial grade 55 inch DISPLAY UNIT having following technical specification 1.Display Size: 55 inches or more 2.Resolution and built in:3840 x 2160 (UHD) ,4K 3.AUDIO: Advanced Audio 4.Built in :Bluetooth Connectivity (optional), built in Wi Fi, 5.Built in Speaker:20W 6.Others:HDMI X 3, DP X 1,USB X1 ,RJ45 X 1 , Digital audio out. 7.Brightness:300 cd/m2 or better 8.Dashboard feature:SNMP support to take control of display to check, Diagnose and Corrections through LAN network, Wake on LAN 9.Operation Temperature:0 °C to 40 °C or better, humidity 80% 10.Warranty: 3 years onsite 11.Mounting:Wall mount and table mount both 12.Display Type:24x7 working compatibility 13.Certificates and Approvals: BIS, ISO 9001, CB/UL
323Supply and erection of prestressed cement concrete pole as per IS: 1678-1960. 11 meters long PCC pole 152 mm x 203 mm at top and 152 mm x 368mm at bottom with working load of 360 KG burried 2.20 m in ground complete in all respect upto the entire satisfaction of Engineer -in-charge of the work.
324Supply and Erection of lightning arrestor model SDU suitable for 11 KV 3 phase 50 cycle per second grounded netural system comprising of spark gap type quench gap in service with non liner resistor element housed in along with mountering clamps and confirming to ISS-3070 (part-I) of 1988 with latest amendments with all labour and material required to complete the job in all respect upto entire satisfaction of the Engineer-in-charge of the work.
325Supply and Erection of 4 MP Indoor Network Mini Dome Camera with Night Vision and 2.8mm Lens 1/3” 4MP PS CMOS Image Sensor,Max. 20fps@4MP, Max. 25/30fps@3MP,H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night(ICR), 3D-DNR,ROI, AWB, AGC, BLC, HLC, 2.8mm fixed lens (3.6mm optional),IR Range of 30 Mtrs, IP67, PoE, Minimum Illumination -0.08Lux/F2.0( Color,1/3s,30IRE) 0.3Lux/F2.0, ( Color, 1/30s,30IRE) 0Lux/F2.0(IR on),Effective Pixels-2688(H) x 1520(V)Shutter Speed- Auto/Manual, 1/3~1/100000s, White Balance- Auto/Natural /Street Lamp/Outdoor/Manual,Lens- 2.8mm (3.6mm optional), Gain Control (AGC)-Auto/Manual, Video Compression-H.265 plus/H.265 /H.264 plus/H.264, S/N Ratio-More than 50dB, Back Light Comp.BLC / HLC / WDR(120dB), Video Streaming- 4MP(1 ~ 20fps) /3MP (1 ~ 25/30fps), D1/CIF(1 ~ 20fps), 720P1 ~ 15fps), Digital Zoom- 16x, Resolution- 4MP(2688x1520/2560x1440) /3MP(2304×1296)/ 1080P (1920×1080) /720P(1280×720)/ D1(704×576/704×480)/ CIF(352×288/352×240),IR Range- IR Range of 30 Mtr., Operating Temperature - -30°C~ plus 60°C , Less than 95%RH ,Power Source- DC12V, PoE (802.3af), Power Consumption- (5.7W, Weatherproof Standard- IP67.
326Supply and Erection of Network Video Recorder of 16 Channels High decoding capability for full HD viewing and recording. Up to 16 channel IP camera input, Smart H.265 plus /H.265/Smart H.264 plus /H.264 codec decoding, Up to 8Mp resolution preview and playback, Max 200Mbps incoming bandwidth, Support 2 SATA HDDs up to 10TB Each, 2 USB Ports (1 USB 3.0), HDMI / VGA simultaneous video output Support Multi-brand network cameras, ONVIF Version 2.4 conformance.
327Supply, Installation, Testing and Commissioning of a 8-port 1000base-T Gigabit PoE plus Smart Managed Switch. The switch should support Network Protocol and Standards Compatibility, including IEEE 802.3 Ethernet, IEEE 802.3i 10BASE-T, and IEEE 802.1x. It should also have the capability to implement Access Control Lists (ACLs) at L2 / L3 / L4 . The switch shall be designed to provide reliable and efficient network connectivity, offering high-speed Gigabit Ethernet connections with Power over Ethernet (PoE plus ) capabilities. It shall enable the management and control of network traffic, ensuring secure and efficient data transmission. The switch will include standard accessories necessary for its installation and operation, ensuring a complete and functional networking solution.
328Supply and erection of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe / trenches / surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm 3 core XLPE cable`
329S/E of stay set suitable for 9/11 mtr long PCC pole made out of 7/8 SWG GI wire with U type MS rod 5/8``dia duly threaded by means of angle iron of size 50mmx6mmx6mm, 30 cm long and 6 ft. long MS rod5/8`` dia, 5` buried in the ground after fixing with cross channel of size 75mmx40mmx60cm. The stay wire will be binded on the top of the pole with the help of suitable size of double U type MS clamps and tied with nuts and bolts. the stay wire shall be insulated in the middle point with the help of insulator(for HT and LT pole) and complete with one coat of red oxide with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work..
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy