Tender For Detection Of Spot Of Leakage And Leakage Removal In Existing Ci/Di/Pvc/Ac Pipe Lines Ofdifferent Sizes In The Area Of Phed Distribution Sub Division Ist Under City Division Ist Kota, Kota-Rajasthan

Public Health Engineering Department-PHED has published Tender For Detection Of Spot Of Leakage And Leakage Removal In Existing Ci/Di/Pvc/Ac Pipe Lines Ofdifferent Sizes In The Area Of Phed Distribution Sub Division Ist Under City Division Ist Kota. Submission Date for this Tender is 26-02-2024. AC Pipes Tenders in Kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42266784
Tender For Detection Of Spot Of Leakage And Leakage Removal In Existing Ci/Di/Pvc/Ac Pipe Lines Ofdifferent Sizes In The Area Of Phed Distribution Sub Division Ist Under City Division Ist Kota
Open Tender
Indian
Rajasthan
Kota
26-02-2024

Tender Details

Tender For Detection Of Spot Of Leakage And Leakage Removal In Existing Ci / Di / Pvc / Ac Pipe Lines Ofdifferent Sizes In The Area Of Phed Distribution Sub Division Ist Under City Division Ist Kota

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: Detection of spot of leakage and leakage removal in existing CI/DI/PVC/AC pipe lines ofdifferent sizes in the area of PHED Distribution Sub Division Ist under City Division Ist Kota
Sl. No. Item Description
1Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe lineup to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
2In all type Soil AC/PVC/HDPE pipe
350/63/75mm
480/90mm
5100/110mm
6125/140mm
7150/160/180mm
8200/225mm
9250/280mm
10300/315mm
11350mm
12400 mm
13Add on above item no. 2 for B.T. Road
14Add on above item no. 2 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
15Add on above no. 2 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
16Add on above no. 2 item if depth of pipeline is above3.0 mtr.
17Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and thenrefilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
18In all type Soil
1980 mm
20100 mm
21125 mm
22150 mm
23200 mm
24250 mm
25300 mm
26350 mm
27400 mm
28450 mm
29500 mm
30600 mm
311000 mm
32Add on above item no. 8 for B.T. Road
33Add on above item no.8for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
34Add on above no. 8 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
35Add on above no. 8 item if depth of pipeline is above3.0 mtr.
36Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof andthen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost)
37In all type Soil
3850/63/75mm
3980/90mm
40100/110mm
41125/140mm
42150/160/180mm
43200/225mm
44250/280mm
45300/315mm
46350mm
47400mm
48450 mm
49500 mm
50600 mm
51Add on above item no.14 for B.T. Road
52Add on above item no. 14 for C.C. Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
53Add on above no. 14 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
54Add on above no. 14 item if depth of pipeline is above3.0 mtr.
55Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site andthen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost)
56In all type Soil
5780 mm
58100 mm
59125 mm
60150 mm
61200 mm
62250 mm
63300 mm
64350 mm
65400 mm
66450 mm
67500 mm
68600 mm
69Add on above item no. 1.4.1 for B.T. Road
70Add on above item no. 1.4.1 for CC Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
71Add on above item no. 1.4.1 if depth of pipe line is above 1.5 mtr to 3.0 mtr
72Deduct on above item no. 1.4.1 if valve is fixed at plinth level / platform i.e. no excavation is required
73Removal of Choking from pipe line, including tree roots, malba, sand and otherby manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material andthen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.
74In all type Soil
7575 mm
7690/80 mm
77110/100 mm
78140/125 mm
79180/160/150 mm
80225/200 mm
81250 mm
82300 mm
83Add on above item no. 26 for B.T. Road
84Add on above item no.26 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
85Add on above item no. 26 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
86Add on above item no. 26 if depth of pipe line is above3.0 mtr.
87Removal of Choking from pipe line, including tree roots, malba, sand and otherby manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material andthen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.
88In all type Soil
8980 mm
90100 mm
91125 mm
92150 mm
93225/200 mm
94250 mm
95300 mm
96Add on above item no.32 for B.T. Road
97Add on above item no. 32 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
98Add on above item no. 32 if depth of pipe line is above 1.5 mtr up to 3.0 mtr.
99Add on above item no.32 if depth of pipe line is above 3.0 mtr
100Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degreethen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour.
101Add on above item no. 37 for B.T. Road
102Add on above item no. 37 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
103Add on above item no. 37 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
104Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof andthen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
105In all type Soil
10680 mm to 110 mm
107125 mm to 165 mm
108200 mm to 300 mm
109Add on above item no. 42 for B.T. Road
110Add on above item no. 42 for CC Road.Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
111Add on above item no.42 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
112Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof andthen refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
113In all type Soil
11480 mm to 100 mm
115125 mm to 150 mm
116200 mm to 300 mm
117350 mm to 450 mm
118Add on above item no.47 for B.T. Road
119Add on above item no.47 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
120Add on above item no.47 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
121Restoration of bitumen road by patch work of WBM using crushed / broken aggregate as per the standard specification and consolidation with hand rammer spreading and consolidation of binding material , cleaning of surface of WBM and providing of seal &tack coat as per site condition by using ready cold mixup to the satisfaction of engineer in charge.The rate includes the makingof pit in regular shape, all labour, material and T&P charge complete job. (minimum200mm depth)
122Restoration of cement concreteroad including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compactingcement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction ofengineer incharge.The rate includes the makingof pit in regular shape, all labour, material and T&P charge complete job.
123Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail