Tender For Shifting Of Existing Pump Set From Indira Kalyan Vihar Pumping Site To Proposed Pumping Site At Okhla Disaster Management Centre And Provision Of Additional Pumping Equipments At Okhla Dmc Premises., Delhi-Delhi

Municipal Corporation-MC has published Tender For Shifting Of Existing Pump Set From Indira Kalyan Vihar Pumping Site To Proposed Pumping Site At Okhla Disaster Management Centre And Provision Of Additional Pumping Equipments At Okhla Dmc Premises.. Submission Date for this Tender is 21-02-2024. Submersible Pump Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42265502
Tender For Shifting Of Existing Pump Set From Indira Kalyan Vihar Pumping Site To Proposed Pumping Site At Okhla Disaster Management Centre And Provision Of Additional Pumping Equipments At Okhla Dmc Premises.
Open Tender
Indian
Delhi
Delhi
21-02-2024

Tender Details

Shifting Of Existing Pump Set From Indira Kalyan Vihar Pumping Site To Proposed Pumping Site At Okhla Disaster Management Centre And Provision Of Additional Pumping Equipments At Okhla Dmc Premises.

Key Value

Document Fees
INR 1770 /-
EMD
INR 175400.0 /-
Tender Value
INR 87.65 Lakhs /-

BOQ Items

Name of Work : -Shifting of existing pump set from Indira Kalyan Vihar pumping site to proposed pumping site at Okhla Disaster Management Centre and provision of additional pumping equipments at Okhla DMC premises.
Sl. No. Item Description
1A. Pumps and piping arrangements: 1. Dismantling of pump set of capacity 150 HP- 1 no. including piping arrangements, electric panel, starters and other accessories and loading the same in a vehicle and transporting at disaster management centre at Okhla phase-II and unloading by using the crane and skilled labour and keeping in safe custody for re-using at site. The work includes cutting of nut bolts, removing the electrical connection of all equipments, transportation, tools and tackles such as tripod arrangement or crane, skilled labour including loading/ unloading etc. complete all as required at site.
2Installation, testing and commissioning of serviceable electrical motor pump set, 150 HP dismantled at serial no. 1 above, complete all as required at site.
3Supply installation testing and commissioning of electrically operated Horizontal Split Casing Pump Set with non-clog impeller to handle storm/ mixed/ sewage water having minimum Discharge of 350 m3/ hr at 70 Mtrs head, 1480 RPM (syn), pump efficiency not less than 82% having suction and delivery size of 200 mm x 150 mm dia. or suitable, mounted on a common base frame including AVM pad coupled with Min. 150 HP or suitable rating three phase, 415 volt, 50 Hz, totally enclosed fan cooled electrical Motor minimum 120 HP or suitable rating complete as required. M. O. C. as Casing- C. I., Impeller- Bronze, Shaft- 40 C8 & Shaft Sleeve- SS 410 complete with coupling, coupling guard and foundation bolts.
4SITC of Horizontal type, self priming non clog sewage pump, single stage Pump, with CI Impeller, ENB shaft & Sleeve, with suitable suction & Delivery LPM 1032 at 10 Mtr, Head up to 20 Mtr coupled with 3 phase 1 Induction motor 5 HP, TEFC, 440 Volt, 1450 RPM with coupling guard, Base frame with AVM etc complete as required
5Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in- charge. (Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately). All works up to plinth level (pump base). (a) All works up to plinth level (For 2 nos. pump sets + 1 charging pump= (2*1*0. 60*2) + (1. 2*0. 9*0. 3*1) =2.724
6Steel reinforcement for R. C. C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo- Mechanically Treated bars of grade Fe- 50D or more
7Providing and fixing of M. S. Black pipe confirming to IS: 3589 Gr. 330 with packing sheets etc. as required of following dia. (i) 80 mm (4. 85 mm thickness)
8(ii) 150 mm (5. 4 mm thickness)
9(iii) 200 mm (9. 5 mm thickness)
10(iv) 250 mm (9. 5 mm thickness)
11Providing and fixing of M. S. Blank Flange fabricated with required nut, bolt, packing sheet etc. as required of following Dia. (i) 250 mm (25 mm thickness)
12Providing and Fixing of M. S. Flange with required nut, bolt, packing sheet etc. as required of following Dia. (i) 80 mm (10 mm thickness)
13(ii) 150 mm (10 mm thickness)
14(iii) 200 mm (16 mm thickness)
15Providing and Fixing of M. S. Bend with required nut, bolt, packing sheet etc. as required of following Dia. (i) 80 mm short bend C-Class
16(ii) 150 mm short bend C-Class
17(iii) 200 mm, 8 mm thick, 0.5 m long
18(iv) 250 mm, 8 mm thick, 0.5 m long
19Supply and fixing of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1. 6 complete as required. (i) NRV 80 MM
20(ii) NRV 200 MM
21(iii) NRV 250 MM
22Supplying, fixing, testing & commissioning of non rising spindle sluice valve of CI body with wedge bronze ring confirming to IS 14846 and SS - 6603, ISI marked complete PN 1.6 complete as required. (i) 80 mm
23(ii) 150 mm
24Providing and Fixing of M. S. reducer 300 mmx200 mm, 10 mm thick, approx. 0. 5 mtr length/ required length at site, with suitable size nut, bolt, packing sheet etc. all as directed at site.
25Providing and Fixing of M. S. enlarger/ reducer 150 mmx300 mm, 10 mm thick, approx. 0. 5 mtr length/ required length at site, with suitable size nut, bolt, packing sheet etc. all as directed at site.
26Supplying and fixing mild steel chequered plate 6 mm thick on cable duct complete all as required at site.
27B. External Electrification: i. Supply, installation testing and commission of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400A to 630 A with heat shrinkable colour coded sleeves suitable for accommodating MCCBs/MCBs/Isolators as incoming and outgoing as required (without MCCBS/MCBS/Isolators) complete with digital meter Module, including voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights including connections etc as required (conforms to IS:8623)
28(ii)MCCB Rating 630A, 415V, FP 3 phase 50KA 50Hz, with spreader, Extended ROM- 1 No. (For incoming in panel).
29(iii) On load change over switch 630 Amp. Open execution type: 2 Nos. (one for DG set and 1 for phase sequence).
30(iv)MCCB with 400 A, 415V, TP 3 phase 35 KA 50Hz, with spreader, Extended arm rotary switch- 3 Nos. (1 for pump and 1 no. as spare).
31S/I/T/C of fully automatic Auto Transformer Starter will be made- out/fabricated with 2mm thick. MS sheet steel, dust & vermin proof, dam & drip-proof, front operated, self supported, free standing type constructions and will be duly spray painted Synthetic Enamel paint of Light Grey shade 631 of IS:5 and accommodate all switch-gear items required to meet the technical requirements of ATS 150 HP & Adequate rating Oil immersed Auto Transformer having Coper winding, class "E" insulation with taping 50%, 65% & 80% (01 No.), Adequate rating Power Contactors, Over Load relay, Single Phase Preventer Relay with Under Voltage & Over Voltage OR As suitable (01 No.), Flush mounting type Ammeter 965q.mm with Selector Switch suitable CT connection (01 No.), Voltmeter 96Sq.mm with Selector Switch (01 No.), Indicating lamp for ON, OFF,TRIP (03 Nos.), Indicating lamp for R,Y,B (03 Nos.) without transformer"s Oil, as follows:- (1). Switch Fuse unit 250 A TPN with Handle FN 250 A-01 No. (2). HRC Fuse 250A-3 Nos. (3). Star Contactor coil voltage 240 AC with 2 No + 2 NC AUX, contacts Block MNX 110-1 No. (4). TAP contactor coil voltage 240 AC with 2 No + 2 NC AUX, contacts Block MNX 225- 1 No. (5). Line contactor coil voltage 240 AC with 2 No + 2 NC AUX. contacts Block MNX 225-1 No. (6). Over Load relay range ACT operated 135-225A MNS-01 No. (7). Current Transformer 15 VA, CL. 1 for Metering 200/5A 3 No. (8). Push Button Start/stop element 22.5mm dia-2 Nos. (9). Indicating lamps 230V AC Red LED Type 3 No. (10). MCB 6A 1P MCB, 10 KA- 1 No. (11). On Delay Timer 0-30 Sec., Coil Voltage 240V, AC 2AODT53 Nos. (12). Ammeter, 0-100/5a, (100-600A) Suppress Scale 6-Time, 96 Sq.mm with Ammeter Selector switch 0-100/5A 1 No. (13). Voltmeter 0- 500V, 96 SQMM size with voltage selector switch 596-1 No.
32MCCB with 100 A, 415V, FP 4 phase 30 KA 50Hz, with spreader, Extended arm rotary switch- 3 Nos. (1 for pump and 1 no. as spare).
33Control MCB 6- 32 Amp. SP for all starter: 03 Nos. (per starter).
34S&F DOL starter suitable for 7. 5 hp with single phase and over load protection for dewatering pump with complete accessories.
35Supply of corrugated & chequered rubber mat for electrical purposes exceeding IS: 5424/ 69 Black or Red in 1 M X 2 M of size. (i) 25 mm thickness
36Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1. 1 KV conforming to IS: 7098/ (Part- I) of following size. (i) 3.5 core 185 sq mm
37(ii) 3.5 core 150 sq mm
38Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1. 1 KV grade of following size in the existing masonry open duct as required. Above 185 Sq mm and up to 400 sq. mm.
39Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1. 1 KV grade as required. (i) 3. 5 X 185 sq. mm (57 mm).
40Earthing with G. I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 metre long etc. with charcoal/ coke and salt as required. (APFC panel, pump, panel).
41Supplying and laying 6 SWG G. I. wire at 0. 50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
42Supplying and laying 25 mm X 5 mm G. I strip at 0. 50 metre below ground as strip earth electrode, including connection/ terminating with G. I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G. I. nut bolt & spring washer spaced at 50mm).
43Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD- 63 mm & ID- 51 mm nominal).
44Providing and fixing ABC (Aluminium Phosphate) Power type fire extinguisher of 6 Kgs capacity complete in all respect with ISI mark i/ c fixing arrangement etc as required as per technical specification attached.
45Providing and fixing 4. 5 kg Co2 type fire extinguisher squeeze grip type, trolly wheel as well as wall mounting type complete in all respect with ISI mark i/ c fixing arrangement etc as required as per technical specification attached.
46S. I. T. C. of 150 W LED flood light luminaire fitted with lens made of pressure die cast aluminium housing &toughened glass cover complete with the following specification as required (b)Total system voltage =150 watt +/- 5% (c) Luminaire Efficiency =100 Lm/ w(d) Power Factor >=0. 95 (e) Protection Class- IP- 66 (for pump house building).
47Supply and fixing of nut bolts of assorted sizes as per site requirement.
48(2Cx2. 5 Sq. MM) Copper Conductor, Flexible cable per meter rate as per latest IS standards.
49DG Set: Supply, Installation, Testing and Commissioning of 250 KVA rating Silent DG set CPCB IV+ comprising of engine coupled to alternator mounted on a common base frame along with other accessories i.e. Standard Control Panel, Panel, Fuel tank, Battery with leads.
50APFC Panel: Supplying, installing, testing & commissioning of APFC Panel, 240 Kvar (Automatic Power Factor Correction) duly compartmentalised wall mounted/ floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly powder coated inclusive of suitable size of 4 strip Al. Busbar complete with interconnection providing Lugs, inter- earthing, painting etc. i/ c providing & fixing below noted accessories: - 1. Suitable Size of INCOMING four pole MCCB, 2. Suitable Size of Analog Ammeter with selector switch C. T. "s etc.- 1 Set, 3. 500 Volt Analog Voltmeter with selector switch- 1 Set 4. RYB LED type Indication lamps with Backup fuses- 1 Set of three., 5. Power factor meter- 1 Set, 6. 14 step APFC relay with aux. Contactor and timer- 1 Set., 7. Suitable capacity 4 strip Al. Bus- Bar., 8. Required numbers of OUT GOINGS with suitable sets & sizes of MCCB compatible to KVAR rating of APFC panel for overall maintaining of required P. F. and also confirming to safe running of complete panel etc., 9. Required set of Push button for START/ STOP., 10. AUTO/ MANUAL Selector switch- 1 No. Complete with all required accessories, connections, interconnection etc as required.
51INTERNAL ELECTRIFICATION: 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1. 5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1. 5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C.
52Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
53Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/ 6 A & 15/ 16 A modular socket outlet and 5/ 6 &15/ 16A modular switch, connections etc. as required.
54Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/ 6 A modular socket outlet and 5/ 6 A modular switch, connections etc. as required.
55Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
56Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm).
57Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 modules (125mm x125 mm).
58Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
59Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/ 6 A switch.
60Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 4 way, Double door.
61Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 8 way, Double door.
62Supplying and fixing 5 A to 32 A rating, 240/ 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole.
63Supplying and fixing following rating, double pole, 240 volt, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps.
64Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2. 5 sq. mm + 1 X 2. 5 sq. mm earth wire.
65Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 2. 5 sq. mm + 2 X 2. 5 sq. mm earth wire.
66Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
67Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Up to 450 mm sweep.
68Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with Brush Less direct current (BLDC) Motor, class of insulation, 3 nos. blades, 30cm long down rod, 2nos. Canopies, shackle kit, safety rope, copper winding, power factor not less than 0. 9, service value (CMM/ W) minimum 6. 85, Air delivery minimum 215 CMM, 350RPM (tolerance as per IS: 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (Max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50Hz, single phase AC supply, earthing etc. complete as required.
69Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
70Supply of 12"" (300 mm) sweep 1400 RPM exhaust fan heavy duty complete with shutter, blade etc as required.
71S. I. T. C of LED Tube type Luminaire 20W rating complete with polycarbonate housing batten integrated electronics driver prewired with high efficient LEDs with the following: (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/ watt >=95 (c) power factor >= 0. 95.
72Providing and fixing of 600 mm sweep Air circulator complete with blades, jaal workable on 220/ 240 volts AC supply etc as reqd.
73Supply, installation, testing & commissioning of single/ three phase Monoblock pump set complete with all accessories workable on 240/ 415 volts, 50 Hz AC supply. (a) 1 HP (0. 75 KW) Single phase pump set, head from 12- 30 mtr, suction and delivery 25X25 mm
74Providing of 500 mm sweep pedestal fan 3 blades, 160 watt 1300-1400 RPM as required
75Supply of 15"" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
76Labour Component: 1. Operator Semi skilled for operation of Electric motor/ Diesel pump set/ DG set/ other equipments along with other day to day works at the pumping station site- One operator in day shift per day for a period of 365 days i.e. 1 person*365 days= 365 Man days.
77Helper Un skilled for assisting the operator for operation of Electric motor/ Diesel pump set/ DG set/ other equipments along with day to day works/ watch and ward of pumping equipments installed at site- 1 in one of the 2 night shifts and 2 in remaining night shift for a period of 365 days i.e. 3 persons*365 days= 1095 Man days.
Disclaimer :