| 1 | Supply and wiring of sub main with three number 2.5 sqmm. FRLSH PVC insulated 1100 V grade single core multistrand single core copper conductor cable in 20mm dia heavy duty 2mm thick PVCconduit on surfacecomplete with 2 number 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable as earthwire drawn inside the conduit,including matching color wash etc. complete in all respects. |
| 2 | Wiring point for light with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall, and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable as earthwire drawn inside the conduit, piano type modularswitch& ceiling rose/angle batten holder on 3mm thick phenolic laminated backelite sheetetc. completion in all respects including matching colour wash. |
| 3 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall, and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable as earthwire drawn inside the conduit, piano type modularswitch& ceiling rose/angle batten holder on 3mm thick phenolic laminated backelite sheetetc. completion in all respects including matching colour wash. |
| 4 | Wiring point for Plug with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall, and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable as earthwire drawn inside the conduit, piano type modular switch & socketetc. completion in all respects including matching colour wash.. |
| 5 | Supply and wiring of sub main with two number 4 sqmm. FRLSH PVC insulated 1100 V grade single core multistrand single core copper conductor cable in 20mm dia heavy PVCconduit concealed in complete with 2.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable as earthwire drawn inside the conduit,including matching color wash etc. complete in all respects. |
| 6 | Supply and wiring of sub main with three number 4 sqmm. FRLSH PVC insulated 1100 V grade single core multistrand single core copper conductor cable in 25mm dia heavy PVCconduit concealed in complete with2nos. 2.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable as earthwire drawn inside the conduit,including matching color wash etc. complete in all respects. |
| 7 | S/F ofelectranic Fan RegulatorModular 120-280V ISI marked on the existing switch board including making connections, required matrials, labour T & Petc. for proper completion of work to the satisfaction of E/c of work. |
| 8 | S/F of surface/flush mounting 12 ways TPN distribution board with additional metal door without MCBs complete in all respects and as directed at site by engineer incharge.Cat A |
| 9 | S/F of surface / flush mounting8ways SPN distribution board with additional metal door without MCBs complete in all respects and as directed at site by engineer incharge. |
| 10 | S/F of40 Amp. DP MCB (10KA) C Curve Cat A |
| 11 | S/F of 6 to 32 Amp. SP MCB (10KA) C CurveCat A |
| 12 | S/F of SP MCB blanking plateCat A |
| 13 | S/F of63 Amp.4P MCB (10KA) C Curve Cat A |
| 14 | S/F of sheet steel enclosure surface/flush mounting fitted with 30Amp. 2pin & earth metal clade scraping earth plug & socket complete in all respects. as directed at site by E/C |
| 15 | Supply and fixing of power plug with 20A/250V flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed MS boxincluding S/o all material, labour, T&P etc. required for proper completion of the work. |
| 16 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) |
| 17 | Supply and burring of Safe Earthing Electrode T-39,( Hot Dip Galvanized), Length up to 2000mm, outer door pipe 50mm, inner Dia 25 mm, terminal Dia 12mm, outer GI pipeof 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystallineconductive mixture (CCM) having anti corrosive & conductive propertywith 50 kgs activatedsoil(BFC) capable of reducing the soil resistivity with good mixture of retainingcapacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (from apron to switch board, of 25mm x 3mm G.I. stripwill be extra) make as App. in UP PWD & CPRI Certified |
| 18 | Supply and burring of Safe Earthing Electrode T-19, Cu Copper coated , Length up to 3000mm, outer door pipe 48.4 mm X 3.2inner Pipe 26.94mm X 2.6mm,terminal Dia 12mm coating80 to 100 micron filled with crystallineconductive mixture (CCM) having anti corrosive & conductive propertywith 50 kgs activatedsoil(BFC) capable of reducing the soil resistivity with good mixture of retainingcapacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (from apron to switch board, of 25mm x 3mm copper. stripwill be extra) make as App. in UP PWD & CPRI Certified |
| 19 | S/F of one number 6 SWG GI wire in 15mm dia G.I pipe for Earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
| 20 | S/F of one number 6 SWG Copperwire in 15mm dia G.I pipe for Earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
| 21 | S/F of 32mm x 6mm G.I. stripfrom earth electrode directly in the ground asrequired complete in all respects |
| 22 | S/F of vertical air termination final rod comprising of 25mm x 3mm GI. strip , GI Clamp on surface complete in all respects |
| 23 | S/F of horizontal air termination Roof conductorof 300mm long X 25mm dia, GI rod with one pointed prong & 100mm dia X 3mm thick base plate etc. complete in all respects App. by Engineer- in-charge. |
| 24 | S/F of testing joint of GI. strip32mm x 63mm & 150mm long with GI bolts & nuts etc. complete in all respects |
| 25 | S/F of 32mm x 6mm copper. stripfrom earth electrode directly in the ground asrequired complete in all respects . |
| 26 | S/L of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer –Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(g) 6 sqmm 4 core |
| 27 | (q) 185 sqmm 3.5 core |
| 28 | (s) 300sqmm 3.5 core |
| 29 | (i) 16 sqmm 4 core |
| 30 | S/F ofrecess/surface/Pendentmounting round40wattLED surface mounting weather proof luminaire with PChousing & opal finish cover confirming to IP65 complete in all respect.4400 system lumens, 110lm/W, PF>0.95with 5years warantee. . Cat AAA |
| 31 | Supply and laying of 1800mmx 900mmx12mm thick chequered rubber matting of tested quality. |
| 32 | Supplying and fixing following modular Tel.socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 33 | Supplying and drawing of 02 pair 0.5 sq.mm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ pvc conduit as required |
| 34 | Supplying and fixing suitable GI box with modular plate and cover in front on surface or in recess, including p&f 6 pin 15/16 & 5/6Amp modular scoket outlet and 15/16 Amps modular switch, connection etc. as required. |
| 35 | Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended FRLSom the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 36 | Supplying and installing 600 mm width X 75 mm depth X 2 mm thickness size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended FRLSom the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 37 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 38 | S/E of Factory fabricated & wiredMetal clad dust & vermin proof floor mounting MS Chanel base with bottom & top cableentres Electrical control panel with TPN MCCBs (Four Pole 36 KA) with thermal magnatic release) Switches complete & instrument chamber etc. complete in all respects. The instrument chamber shall be separate & shall comprise of flush type digital metering system for phase to phase voltage & single phase voltage, current & other parameters( KVA, PF, KW etc.) in each phase with touch type selector switches for different readings, instrument fuses, current Tr. etc. The panel board shallhave suitable capacity electrolytic Al. busbars as per IS8623 or above insulated with heat shrink sleeving & mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers & shall be suitable for extention on the sides. The MCCBsshall be complete with suitable cable end boxes, compression glands & indicating lamp on incoming etc. The job includes the grounting of the board as per directions of Engineer-in charge. All out going of 100 Amp. & above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a min. thikness of 1.6mm/2mm. Cubicle type switch board shall be ofcat BIncomming- 400Amp. MCCB-01 NosOutgoing- 100 Amp MCCB- 03 Nos & 63 Amp MCCB- 01 No+ 40 Amp. MCB -06Nos. + 400Amp 4 Pole on load Change Over(b) (ii)+1016 Cat A +381A |
| 39 | S/O 1200 mm Ceiling Fan with fan Motor of AC Permanent insulation, capacitor rating conforming BEE 5Star rating & IS: 374/79 & also comply with IS:1709/1984with latest amendment. The rated voltage 220/240 V,50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc & with double ball bearing system. |
| 40 | S/F of Fire Extinguisher ABC type 6.00Kg capacity(ISI Marked IS: 15683 & TAC Approved) Complete with initial charge & Wall Bracket, along with S/o of all matrials & labour for Proper completion of work. |
| 41 | S/F of Fire Extinguisher Co2 type 4.50Kg capacity(ISI Marked IS: 15683 & TAC Approved) Complete with initial charge & Wall Bracket, along with S/o of all matrials & labour for Proper completion of work |
| 42 | Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. |
| 43 | Supply and fixing of PUF Insulation panel of thickness of 80 mm, for Cold Room walls & ceiling including Common walls inclusive of all accessories as per specification for 03 Nos of Cold Room with 100 MT capacity (Dimenssion - 16.0x6.1x3.5 mtr). Make - Lloyd insulation, Sintex, Rinac, Jindal, BNAL, DIGNUS (PUF Panel Thickness a) Cold Room - 80 mm (walls) 80mm (ceiling) b) Density - 40 +/- 2 Kg/M3 c) Closed cell content - 90 - 95% d) Thermal Conductivity - 0.023 W/mKe) Compressive Strength - 2.1 kg/ m2 (at 10% deformation) f) Water Vapour Permeability - 0.8 -.12 gms/hr m2 g) Fire Resistance - Self extinguishing h) Blowing Agent - CFC Free i) Sheet - 0.5 mm TCT, PPGI) |
| 44 | Supply and fixing of Cold Room Floor with, Insulation Material- PUF slab of 80mm thickness( in 2 layers of 40 mm each), Vapour Barrier, inclusive of all accessories as per specification. Make - Lloyd Insulation, Sintex, Rinac, Jindal, BNAL, DIGNUS, Industrial Foam. a) Insulation Material - PUF slab b) Density - 40 +/- 2 Kg/M3 c) No. of Layers - 2 layers ( 40 mm each) d) Total Thickness - 80 mm e) Vapor Barrier - Tarfelt, Polythene Sheet as per dwg f) VDF floor - VDF as per dwg) |
| 45 | Supply and Installation of Cold Room Doors (for positive temp) insulated type of Horizontal Manual Sliding Door, Dimensions -1500 mm x 2100mm ( clear) with Sandwich panels constructed of a core of 80 mm PUF complete with all accessories as per specification Make - Metaflex, lloyd insulation, Rinac, Hormann, Gandhi Automation (a) Type of Door - Manual Sliding Door b) Dimensions - 1500 X 2100MM c) Type of panel - Sandwich panels constructed of a core of 80 mm PUF on both sides covered with 0.6 mm galvanized steel plate finished with 20mucoating. The panels are supplied with thermal bridge-free PVC surrounding profilesd) Sealing - All round with triple rubber profile e) Colour outside - RAL 9002 (white) f) Colour inside - Standard colour RAL 9002 (white/grey) g) Hardware - Galvanised Steel h) Track Rail - Drop/Lift rail system i) Finish of opening - To be Included j) Door Operation - Manual) |
| 46 | (reference capacity 27kw for each room) complete with all spares as per specification for each of 3 no cold room be provided with Freon 404A based refrigeration system to cater to the refrigeration design load and suitable PLC System to control and monitor the operations as per specification for each of 3 nos cold rooms.. 1. DESIGN TEMP: EVAPORATION -7.5 DEG C, CONDENSING 53.5 DEG C 2. COMPRESSOR – SCROLL (1 PER COLD ROOM) 3. AIR COOLED CONDENSER, AIR VOLUME 10400 M3/HR, FANS TO BE CONTROLLED BY TEMP CONTROLLER , SUCTION 15/8”, LIQUID 7/8”. TYPICAL DIMENSIONS : 1591MM (LENGTH) X 998MM (HEIGHT) X 1000MM (DEPTH) (MAKESBITZER, BOCK, FRASCOLD, CARRIER) 4. COOLERS OF CAPACITY 27 KW (1 PER COLD ROOM. WITH 3 AXIAL FANS OF 450MM, 19200 M3/HR, FIN SPACING 4 FIN/ SQ. INCH (MAKES – LUVE, PATTON, GUNTNER, STAR COOLER) – TYPICAL DIMENSIONS : 3500MM (LENGTH) X 655MM (HEIGHT) X 675MM (DEPTH) 5. VENTILATION FAN 450MM 6. CONTROLS, THERMOSTAT, SOLENOID VALVE, VALVE, SIGHT GLASS 7. CONTROL PANEL FOR EACH ROOM AT REAR SIDE OF COLD ROOM CONTROL PANEL (PLC CONTROLS TYPE) TO HAVE FOLLOWING FEATURES – STARTING ARRANGEMENT FOR COMPRESSOR (HP/LP/OP CUT OUT FOR EACH COMPRESSOR) CONTRACTOR FOR CONDENSER FAN, THERMOSTATIC CONTROLLER FROM DANFOSS FOR CONTROLLING THE FAN, CRANKCASE HEATER TO OPERATE WHEN COMPRESSOR IS STOPPED AND OFF WHEN RUNNING. LIGHTING MAIN SWITCH ALSO IN THE PANEL. THIS WILL HAVE ALL STARTERS WITH INTERLOCKING SYSTEM. PUSH BUTTONS FOR START/STOP. HUMIDIFIER & ETHYLENE SCRUBBER SWITCHES ALSO IN THE PANEL. OVERLOAD RELAYS & FUSES, NAME PLATES |
| 47 | Supply, Installation, Testing & Commissioning of Ultrasonic type humidification system in all Cold rooms with automated controls capable of providing 90 - 95% RH in each room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, , complete with all connections in all rooms as per specification - The humidification system offered should be ltrasonic type humidification system in all Cold rooms with automated controls capable of providing 90 - 95% RH in each cold room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, complete with all connections in all rooms as per specification |
| 48 | Supply and fixing of PUF Insulation panel of thickness of 40 mm having Density 40 kg/cu.m (+/- 2), 0.5 mm thick PPGI sheet, thermal conductivity [0.023 W/mK], for ceiling at loading, unloading and Admin area (3.5 mtr. Hight from floor level) inclusive of all accessories and installation as per specification. Make - Lloyd Insulation, Sintex, Rinac, Jindal & DIGNUS . |
| 49 | Supply, Installation, Testing and Commissioning of Portable Ethylene Generator connected to an electrical plug point inside the room, the Ethylene Generator should be suitable for providing suitable levels of ethylene (as per the fruit category) in ripening rooms of volume around 60 cum by catalytic dehydration of developing liquid into ethylene gas complete with suitable developing liquid required for commercial ripening applications for each of the ripening rooms as per specification alongwith 5 ltr of developing liquid ethylene with each generator. Make- Aseko, Catalytic, American Ripener (The provision for Ethylene Gas dosage for ripening in each room shall be by placing a Portable Ethylene Generator connected to an electrical plug point inside the room. The Ethylene Generator should be suitable for providing suitable levels of ethylene (as per the fruit category) in ripening rooms of volume around 58 cum by catalytic dehydration of developing liquid into ethylene gas complete with suitable developing liquid required for commercial ripening applications.) |
| 50 | Supply, Installation, Testing and Commissioning of Ethylene Gas sensor complete with display in all 4 Ripening Rooms of catalytic type with measuring range upto 2000 ppm for ripening room application as per specification. Make- Aseko, Carel |
| 51 | Supply, Installation, Testing and Commissioning of CO2 gas sensors complete with display in all 4 Ripening Rooms of infrared type with measuring range 0 – 5%suitable for ripening application as per specification. Make- Aseko, Carel |
| 52 | Supply, Installation, Testing and Commissioning of Air Ventilation Systems connected with gas control system for all Ripening Roomssuitable for ripening application as per specification |
| 53 | Supply, Installation, Testing and Commissioning of CO2 gas sensors complete with display in all 4 Ripening Rooms of infrared type with measuring range 0 – 5%suitable for ripening application as per specification. Make- Aseko, Carel |
| 54 | Supply, Installation, Testing and Commissioning of Air Ventilation Systems connected with gas control system for all Ripening Roomssuitable for ripening application as per specification |
| 55 | Supply, Installation, Testing and Commissioning of Plastic Pallet of size : 1200 x 1000 x 150 mm with 4 way entry HDPE 100% virgin material |
| 56 | Supply, Installation, Testing and Commissioning of Platform weighscale of electronic digital type of 200 kg capacity as per specifications Make - Kantawala, Swastik, Dewlite, Avery (a) Capacity 200 Kg b) Pan Size & MOC 400mm X 500mm minimum c) SS for 200 kg e) Least Count 20 gm maximum for 200 kg h) 100% Tare through Keyboard i) Stamping to be provided) |
| 57 | Supply, Installation, Testing and Commissioning of hand pallet truck with 2500 kg lifting capacity as per specification Make - Godrej, Voltas, Mahindra, Jay, Maini (a) Load Capacity : 2500 mm b) Fork Length : 1100 mm c) Fork Width : 150 mm d) Out Side Fork Spread : 550 mm e) Inside Fork Spread : 250 mm f) Maximum Fork Height : 185 mm g) Minimum Fork Height : 75 mm) |
| 58 | Supply, installation, testing & commissioning of Diesel Generating Set of 40KVA rating Silent Type Radiator type, suitable for of 415V, 3 phase 4 wire, 0.8 pf. (lagging) 50c/s A.C supply complete with engine (1500 RPM) and alternator DG Set controller with accessories including residential type silencer and manual control panel fuel service tank as per standard, battery and battery charger with all associated accessories including MCCB of suitable rating & standard set of tools and anti-vibration mounting pads etc. The specification shall be as per GEM specification attached. The instalation, testing, commissioning shall be done as per GEM |
| 59 | Supply, Installation, Testing and Commissioning of Plastic Pallet of size : 1200 x 1000 x 150 mm with 4 way entry HDPE 100% virgin materia |
| 60 | Providing preventive maintenance, repair, replacement for all equipment for a period of 4 years after warranty period |
| 61 | Providing skilled one manpower for the Management of proposed cold room facility. The agency will be responsible for the management of facility in terms of accounting and etc for the first year. |
| 62 | Providing skilled one manpower for the Management of proposed cold room facility. The agency will be resposible for the management of facility in terms of accounting and etc for the 2nd year |
| 63 | Providing skilled one manpower for the Management of proposed cold room facility. The agency will be resposible for the management of facility in terms of accounting and etc for the 3rd year |
| 64 | Providing skilled one manpower for the Management of proposed cold room facility. The agency will be resposible for the management of facility in terms of accounting and etc for the 4thyear |
| 65 | Providing skilled one manpower for the Management of proposed cold room facility. The agency will be resposible for the management of facility in terms of accounting and etc for the 5th year |