}

Tender For Electrical And Allied Works, Chandrapur-Maharashtra

District Collector-DC has published Tender For Electrical And Allied Works. Submission Date for this Tender is 06-03-2024. MCCB Tenders in Chandrapur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42246721
Corrigendum : Tender For Electrical And Allied Works
Open Tender
Indian
Maharashtra
Chandrapur
06-03-2024

Tender Details

Tender For Electrical And Allied Works-2 External Lighting-Feeder Pilarhigh Mast Light Supply, Installation, Testing & Commissioning Of 16M High Masts With Following:Supplying And Erecting 16 M ( Clear Height ) Motorized High-Mast ( Top-150Mm, Bottom-410 Mm ) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen -10025 S 355 / E350 & 3 Mm Thickness, With Base Plate 25 Mm Thick X Od 570 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Arc Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 6 Mm, Sg-Dg U Clamps, Double Drum Winch Assembly 350 Kg, 5X2.5 Sq.Mm Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 16 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report / Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud / Bolts With Necessary Accessories Complete. Specification No. Ohpl / Hm ( Excluding Luminaries ) 3 External Lighting-Feeder Pilar16 Nos. Led Light Fixtures As Per Crompton Greaves Catalogue No. Lsfo-C300-Cdl-60 With 1X300w Flood Light With Minimum Lumen / Lamp 31000 ( For 1 Set 16 Nos Led Light ) 4 External Lighting-Feeder Pilar Outdoor Type Ip 65 Design, Supply, Installation & Commissioning Of Floor / Wall Mounting / Free Standing, Totally Enclosed Compart-Mentalized, Cubical, Dust, Vermin Proof External Lighting Panel Fabricated Out Of 2Mm Thick Cold Rolled Carbon Annealed, Sheet Steel, Internally Straightened With 35Mm X35mm X6mm Angle Iron Frame Work With Hinged Centre Opening Type Double Doors, ( Fabricated Out Of 2Mm Crca Sheet Steel ) The Fabricated Panel With Ip-65 As Enclosure Protection As Per Specification. Supplying And Mounting Including Making Connections / Interconnection With Lugs / Glands Testing And Commissioning Of Following Items Inside The Panel. Incomeraluminium Bus Strips Of High Electrolytic Conductivity 200A, 3- Phase With Neutal, 415V, 50 Hz, ( + / - 10% ) Ac Supply -1Set. Mccb 4 Pole 100 Amps, 25 Ka, 415 V, 3 Phase, Ac Supply With In Built Overload, Short Circuit & On / Off Indication On The Front- 1No. Led Type Phase Indicating ( R-Y-B ) Lamps Provided With McbS Protections And Individual Toggle Switches Having Lens And Lamp Visible From The Front -1Set. 1 Set Of ( 0-500V ) Voltmeter With Selector Switch & Control McbS. 1 Set Of ( 0-100A ) Ammeter With Selector Switch & 100 / 5A Ratio Cts. 1 No. Astronomical Timer Outgoingsmcbs 16A / 20A, Dp, 10Ka, C Series -12 Nos. On Each Phase Mcbs 25A / 40A, 4P, 10Ka, C Series -5 Nos. Feeder Pillar As Described Above 5 Boom Barrier System Supply, Installation, Testing And Commissioning Of Automatic Boom Barrier Suitable For 5.0M-7.5M Road Width Forintensive Applications, High Speed With 4.5 Second Opening Time With Straight Aluminium Boom Of Minimum Size 100Mm X 70 Mm, Builtin Blinker Indicator Etc. Complete Asrequired As Per Specifications & At Site Of Work. 6 Boom Barrier System Supply, Installation, Testing And Commissioning Of A Set Of Entry / Exit Push Buttons For Manual Open And Closing Of Barrier Etc.Complete As Required. 7 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Main Lt Panel Dimensions : 14 M ( W ) X 1.5 M ( D ) X 2.2 M ( H ) 8 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Ht Panel Dimensions :3 M ( W ) X 2 M ( D ) X 2.2 M ( H ) 9 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Dg Panel Dimensions :6 M ( W ) X 1.5 M ( D ) X 2.2 M ( H ) 10 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Fire Emergency Panel Dimensions :5 M ( W ) X 1.2 M ( D ) X 1.8 M ( H ) 11 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Lift Panel-1 Dimensions :2.5 M ( W ) X 0.6 M ( D ) X 1.6 M ( H ) 12 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Lift Panel-2 & 3 Dimensions : 1.1 M ( W ) X 0.6 M ( D ) X 1.6 M ( H ) 13 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Capacitor Panel - 1 & 2 Dimensions : 2.5 M ( W ) X 1.5 M ( D ) X 2.2 M ( H ) 14 Panel Suppression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Linear Pneumatic Tube Detection Based Fk-5-1-12 / Novec 1230 Fluid ( Ul Listed ) System For Electrical Panels ( Linear Pnuematic Heat Detection Tube Panel Protection System ) , Consisting Of Following Components For Electrical Panel: 4 Kg Novec 1230 Fluid / Fk-5-1-12 , Dlp Assembly With Automatic Valve, Push In Connector For Tube, Mounting Bracket, End Of Line Adaptor And Low Pressure Switch For Monitoring System Activation. Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports.A / V Alarm With Battery Backup Ups Panel - 1 & 2 Dimensions :2.5 M ( W ) X 0.6 M ( D ) X 1.6 M ( H ) 15 Kitchen Hood Supression System Design, Supply, Fixing, Testing And Commissioning Of Automatic Kitchen Hood Suppressions System Including The Following9 Liters Firedetec ® F / K Ea Stainless Steel Cylinder, Ilp Cylinder / Valve Assembly, Mounting Bracket, Flexible Hose, Ss Tube Fittings, Tube Clamps, Firedetec Tube ( Grey ) Alongwith Cross Panel Fittings , Fdt Tube Clamps , Manual Release Device , With Pressure Switch And T Connectors Ss Tubing Nozzle 1 Hole For Kitchen System / R 1 / 4 / Stainless Steel / Class F Agent Alarm Box 16 Gas Shut Off Valve 17 Total Room Flooding System1x55 Itr Completele Ccoe Approved High Pressure Seamless Bis 7285 Approved Cylinders Having55 Ltr Capacity, Ul / Fm / Vds Approved Fk5-1-12 Clean Agent Gas With Ul / Fm / Vds Listed Valve Assembly And Electric Solinoid Switch. The System Also To Be Fitted With Low Pressure Supervisory Switch For Monitoring Cylinder Pressure Gauge With Safety Burst Disc Safety Cap, Elbow And Other Accessories, Mounting Bracket, Container Straps, Nrv , Pressure Operated Control Head Which Shall Allow For Pressure Actuation Of Gas Mounted, Manually Operated Actuator To Actuate The Gas Flooding Process With The Help Of A Lever, Flexible Rubber Hose With Wire Bralded Enforcment To Route The Gas From The Storage Cyinder To The Discharge Piping, To Be Connected To The Discharge Outlet Of Gas Cylinder Valve & To Be Terminated At The System Piping Or Discharge Manifold, Flexible Actuation Hose Complete As Required. Discharge Nozzle, 180 / 360 Degree. Designated To Provide Proper Flow Rate & Distribution Fk5-1-12 Gas To Flood The Hazard Area As Per Latest Nfpa 2001 Requrement. Piping Astm Grade A 106 Schedule 40 With Fittings & Supports And Gas Release Panel Compatible To Fire Alarm System. ( Ups Room-1 ) 18 Total Room Flooding System1x55 Itr Completele Ccoe Approved High Pressure Seamless Bis 7285 Approved Cylinders Having55 Ltr Capacity, Ul / Fm / Vds Approved Fk5-1-12 Clean Agent Gas With Ul / Fm / Vds Listed Valve Assembly And Electric Solinoid Switch. The System Also To Be Fitted With Low Pressure Supervisory Switch For Monitoring Cylinder Pressure Gauge With Safety Burst Disc Safety Cap, Elbow And Other Accessories, Mounting Bracket, Container Straps, Nrv , Pressure Operated Control Head Which Shall Allow For Pressure Actuation Of Gas Mounted, Manually Operated Actuator To Actuate The Gas Flooding Process With The Help Of A Lever, Flexible Rubber Hose With Wire Bralded Enforcment To Route The Gas From The Storage Cyinder To The Discharge Piping, To Be Connected To The Discharge Outlet Of Gas Cylinder Valve & To Be Terminated At The System Piping Or Discharge Manifold, Flexible Actuation Hose Complete As Required. Discharge Nozzle, 180 / 360 Degree. Designated To Provide Proper Flow Rate & Distribution Fk5-1-12 Gas To Flood The Hazard Area As Per Latest Nfpa 2001 Requrement. Piping Astm Grade A 106 Schedule 40 With Fittings & Supports And Gas Release Panel Compatible To Fire Alarm System. ( Battery Room-1 ) 19 Total Room Flooding System1x55 Itr Completele Ccoe Approved High Pressure Seamless Bis 7285 Approved Cylinders Having55 Ltr Capacity, Ul / Fm / Vds Approved Fk5-1-12 Clean Agent Gas With Ul / Fm / Vds Listed Valve Assembly And Electric Solinoid Switch. The System Also To Be Fitted With Low Pressure Supervisory Switch For Monitoring Cylinder Pressure Gauge With Safety Burst Disc Safety Cap, Elbow And Other Accessories, Mounting Bracket, Container Straps, Nrv , Pressure Operated Control Head Which Shall Allow For Pressure Actuation Of Gas Mounted, Manually Operated Actuator To Actuate The Gas Flooding Process With The Help Of A Lever, Flexible Rubber Hose With Wire Bralded Enforcment To Route The Gas From The Storage Cyinder To The Discharge Piping, To Be Connected To The Discharge Outlet Of Gas Cylinder Valve & To Be Terminated At The System Piping Or Discharge Manifold, Flexible Actuation Hose Complete As Required. Discharge Nozzle, 180 / 360 Degree. Designated To Provide Proper Flow Rate & Distribution Fk5-1-12 Gas To Flood The Hazard Area As Per Latest Nfpa 2001 Requrement. Piping Astm Grade A 106 Schedule 40 With Fittings & Supports And Gas Release Panel Compatible To Fire Alarm System. ( Server Room-1 ) 20 Total Room Flooding System1x34 Itr Completele Ccoe Approved High Pressure Seamless Bis 7285 Approved Cylinders Having34 Ltr Capacity, Ul / Fm / Vds Approved Fk5-1-12 Clean Agent Gas With Ul / Fm / Vds Listed Valve Assembly And Electric Solinoid Switch. The System Also To Be Fitted With Low Pressure Supervisory Switch For Monitoring Cylinder Pressure Gauge With Safety Burst Disc Safety Cap, Elbow And Other Accessories, Mounting Bracket, Container Straps, Nrv , Pressure Operated Control Head Which Shall Allow For Pressure Actuation Of Gas Mounted, Manually Operated Actuator To Actuate The Gas Flooding Process With The Help Of A Lever, Flexible Rubber Hose With Wire Bralded Enforcment To Route The Gas From The Storage Cyinder To The Discharge Piping, To Be Connected To The Discharge Outlet Of Gas Cylinder Valve & To Be Terminated At The System Piping Or Discharge Manifold, Flexible Actuation Hose Complete As Required. Discharge Nozzle, 180 / 360 Degree. Designated To Provide Proper Flow Rate & Distribution Fk5-1-12 Gas To Flood The Hazard Area As Per Latest Nfpa 2001 Requrement. Piping Astm Grade A 106 Schedule 40 With Fittings & Supports And Gas Release Panel Compatible To Fire Alarm System. ( Ups Room-2 )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Feb-2024 Corrigendum Other 20-02-2024
2 20-Feb-2024 date extenssion 1 Date 23-02-2024
3 23-Feb-2024 Date extenssion Date 29-02-2024
4 01-Mar-2024 date extenssion Date 06-03-2024

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work F2. ELECTRICALAND ALLIED WORKS
Sl. No. Item Description
1F2. ELECTRICALAND ALLIED WORKS
2External lighting-Feeder Pilar High Mast Light Supply, installation, testing & commissioning of 16M High masts with following:Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 570 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OHPL/HM (excluding luminaries)
3External lighting-Feeder Pilar 16 nos. LED light fixtures as per Crompton Greaves catalogue no. LSFO-C300-CDL-60 with 1x300w flood light with minimum lumen/ lamp 31000 ( For 1 Set 16 nos LED Light)
4External lighting-Feeder Pilar Outdoor Type IP 65 Design, supply, installation & commissioning of floor/ wall mounting/ free standing, totally enclosed compart-mentalized, cubical, dust, vermin proof external lighting panel fabricated out of 2mm thick cold rolled carbon annealed, sheet steel, internally straightened with 35mm x35mm x6mm angle iron frame work with hinged centre opening type double doors, (fabricated out of 2mm CRCA sheet steel) The fabricated panel with IP-65 as enclosure protection as per specification. Supplying and mounting including making connections/ interconnection with lugs/ glands testing and commissioning of following items inside the panel. Incomer Aluminium bus strips of high electrolytic conductivity 200A, 3- Phase with neutal, 415V, 50 Hz, (+/- 10%) AC supply -1set. MCCB 4 pole 100 Amps, 25 kA, 415 V, 3 phase, AC supply with in built overload, short circuit & ON/ OFF indication on the front- 1No. LED type phase indicating (R-Y-B) lamps provided with MCB"s protections and individual toggle switches having lens and lamp visible from the front -1set. 1 Set of (0-500V) voltmeter with selector switch & Control MCB"s. 1 Set of (0-100A) ammeter with selector switch & 100/5A ratio CTs. 1 No. Astronomical timer Outgoings MCBs 16A/20A, DP, 10kA, C series -12 Nos. on each phase MCBs 25A/40A, 4P, 10kA, C series -5 Nos. Feeder Pillar as described above
5Boom Barrier System Supply, installation, testing and commissioning of automatic boom barrier suitable for 5.0m-7.5m road width forintensive applications, high speed with 4.5 second opening time with Straight aluminium boom of minimum size 100mm x 70 mm, builtin blinker indicator etc. complete asrequired as per specifications & at site of work.
6Boom Barrier System Supply, installation, testing and commissioning of a set of Entry/ Exit push buttons for manual open and closing of barrier etc.complete as required.
7PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Main LT Panel Dimensions : 14 m (W) x 1.5 m (D) x 2.2 m (H)
8PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup HT Panel Dimensions :3 m (W) x 2 m (D) x 2.2 m (H)
9PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup DG Panel Dimensions :6 m (W) x 1.5 m (D) x 2.2 m (H)
10PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Fire Emergency Panel Dimensions :5 m (W) x 1.2 m (D) x 1.8 m (H)
11PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Lift Panel-1 Dimensions :2.5 m (W) x 0.6 m (D) x 1.6 m (H)
12PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Lift Panel-2 & 3 Dimensions : 1.1 m (W) x 0.6 m (D) x 1.6 m (H)
13PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup Capacitor Panel - 1 & 2 Dimensions : 2.5 m (W) x 1.5 m (D) x 2.2 m (H)
14PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed)System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm with battery backup UPS Panel - 1 & 2 Dimensions :2.5 m (W) x 0.6 m (D) x 1.6 m (H)
15KITCHEN HOOD SUPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Kitchen Hood Suppressions System including the following 9 Liters FireDETEC ® F/K ea stainless steel cylinder, ILP Cylinder/valve assembly, mounting bracket, Flexible Hose, SS Tube fittings, Tube clamps, FireDeTec tube ( Grey) alongwith cross panel fittings , FDT tube clamps , Manual Release Device , with Pressure Switch and T connectors SS Tubing Nozzle 1 hole for kitchen system / R 1/4" / Stainless steel / Class F agent Alarm Box
16Gas Shut Off Valve
17TOTAL ROOM FLOODING SYSTEM 1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (UPS ROOM-1)
18TOTAL ROOM FLOODING SYSTEM 1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (BATTERY ROOM-1)
19TOTAL ROOM FLOODING SYSTEM 1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (SERVER ROOM-1)
20TOTAL ROOM FLOODING SYSTEM 1x34 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having34 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (UPS ROOM-2)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail