Tender For Provision Of Certain New Igloo Sheds Phase Iii At Af Station Amla, Betul-Madhya Pradesh

Military Engineer Services-MES has published Tender For Provision Of Certain New Igloo Sheds Phase Iii At Af Station Amla. Submission Date for this Tender is 28-05-2024. Vegetables and Fruits Tenders in Betul Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42242851
Corrigendum : Tender For Provision Of Certain New Igloo Sheds Phase Iii At Af Station Amla
Open Tender
Indian
Madhya Pradesh
Betul
28-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Provision Of Certain New Igloo Sheds Phase Iii At Af Station Amla

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Mar-2024 DateCorrigendum01 Date 26-04-2024
2 02-Apr-2024 Revised Drawings Technical Bid 26-04-2024
3 02-Apr-2024 TECHNICAL BID CORRIGENDUM Technical Bid 26-04-2024
4 16-Apr-2024 DATE CORRIGENDUM 03 Date 06-05-2024
5 26-Apr-2024 DATECORRIGENDUM04 Date 15-05-2024
6 06-May-2024 Date Corrigendum 05 Date 28-05-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 26.26 Crore /-

Attachment

FileName File Description File Size
17b92e54-cce9-432d-bcd8-a78ae85019b8.html Tender Notice 0 KB
BOQ_719103.xls Tender Document 0 KB
CompleteDrawingSet.pdf Tender Document 0 KB
CompleteTender.pdf Tender Document 0 KB
IntegrityPact.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: PROVISION OF CERTAIN NEW IGLOO SHEDS (PHASE-III) AT AFS AMLA
Sl. No. Item Description
1Blank
2Blank
3Blank
4Blank
5Blank
6Blank
7Blank
8Blank
9Blank
10Blank
11Blank
12Blank
13SCH "A" PART XIV (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule "A" Part-II.
14Supply and fixing hazard division symbol double sided board of size 1500 x 1500 mm by using double legged informatory sign board fixed on single frame and meeting back to back on the square pipe, boards of high intensity Green/blue or in colour as required by using retro-reflective sheeting of AVERY DENNISON made out of 2 mm thick Alco bond/ aluminium sheet conforming to IS 736 to be covered with high intensity grade retro-reflective sheeting (AVERY DENNISON) of Green/Blue or required colour as per user complete all as specified and as directed.
15NOTES :- (i) The computerized cut AVERY DENNINSON sheet shall be fixed with suitable adhesive to alco bond/ aluminium sheet painted with epoxy paint to standard make, fixed to structural steel frame work of MS pipe of size 35 x 35mm square pipe with nuts, bolt/rivets ensuring safety against removal of plates. (ii) The lettering shall be computerised cut of high intensity grade white sheeting (AVERY DENNISON) and mechanically fixed on this board of Green/Blue colour or required color. Then these two separate boards shall be fixed back to back on single frame to two vertical posts of 50mm square pipe 2.5 mtr long to be painted in black and white alternative bands of 25cm height with synthetic enamel paint complete in all respect. (iii) This board on single frame shall be embedded in PCC 1:4:8, type D2 of required size including necessary excavation in post hole all as specified and as directed.
16Supply and fixing double legged informatory sign board single side of size 1200 x 1200 mm, fixed on single frame and meeting back to back on the square pipe, board of high intensity Green/blue or in colour as required by using retro-reflective sheeting of AVERY DENNISON made out of 2 mm thick Alco bond/ aluminium sheet conforming to IS 736 to be covered with high intensity grade retro-reflective sheeting (AVERY DENNINSON) of Green/Blue or required colour as per user complete all as specified and as directed.
17NOTES :- (i) The computerized cut AVERY DENNINSON sheet shall be fixed with suitable adhesive to Alco bond/aluminium sheet painted with epoxy paint to standard make, fixed to structural steel frame work of MS pipe of size 35 x 35mm square pipe with nuts, bolt/rivets ensuring safety against removal of plates. (ii) The lettering shall be computerised cut of high intensity grade white sheeting (AVERY DENNISON) and mechanically fixed on this board of Green/Blue colour or required color.Then these two separate boards fixed back to back on single frame are fixed to two vertical posts of 50mm square pipe 2.0 mtr long to be painted in black and white alternative bands of 25cm height with synthetic enamel paint complete in all respect. (iii) This board on single frame shall be embedded in PCC 1:4:8, type D2 of required size including necessary excavation in post hole all as specified and as directed.
18INTERNAL ELECTRIFICATION
19Material and labour for flameproof sub main wiring with 2 runs of 2.5 Sqmm as main cable and one run of 2.5 sqmm as earth continuity conductor on wall and surface wiring on ceiling / roof with necessary fixing arrangements using approved colour coding as per IS with single core PVC insulated unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade, IS-694 marked, drawn through ISI Marked (IS 9537 Part II) ERW stove enamelled rigid steel conduit suitable for wiring, not less than 20mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., and making good the disturbed surface complete all as specified and as directed.
20Notes : (i) Flame proof accessories shall be measured and paid separately. (ii) One switch shall control 4 to 5 Nos FP Points fitting. (iii) 3 runs of 2.5 sqmm cable and 1 run of conduit shall be measured as 1 unit .(iv) Rates of flame proof bends and elbows, couplers, bell mouth reducer etc are deemed in the rate quoted.
21Supply and fixing surface mounted flame proof weather proof threaded type junction box LM 6 aluminum alloy 3 to 4 way with closing plug complete all as specified and as directed.
22Supply and fixing surface mounted flame proof weather proof LM6 union (male, female type)for 20 mm dia conduit complete all as specified and as directed.
23Supply and fixing flame proof weather proof LM6 couplingsfor 20 mm dia conduit complete all as specified and as directed.
24Supply and fixing surface mounted Flame proof switch /isolator cast iron body 16A single pole ON/OFF, 240 volts LM-6 (rotary type) certified by CMRI complete all as specified and as directed.
25Supply and fixing CMRI Dhanbad certified LED Flameproofwell glass luminaries 60W with LM 6 aluminum alloy lamp housing, heat resistant and toughened glass, cover hinges cover with neoprene gasket, painted MS bar guard, epoxyfinish provided with built in controlgear box complete with all accessories internallyprewired& eye bolt for suspension, IP65 Protectionand including fixing light fitting on wall/ roof and making all electrical connectioncomplete all as specified and as directed.
26Supply and fixing weather proof flame proof with IP55 sheet metal enclosure for DB SPN 8 way 240A - 200A rated bus bar certified by CMRI Dhanbad of cast aluminium alloy LM-6 construction with cable entries at bottom consisting of DB with one 20A, 10KA MCB SPNas incomer and MCB SP 6 A, 10KA -04Nosas outgoing including flameproof cable gland & lugs at bottom side etc. including making connection complete all as specified and as directed.
27Material and labour for earthing with galvanized iron earth plate of size 600 mmx600mmx6mm thick buried directly in ground not less than 2.25 mtr below normal ground level, earth plate packed on all side with charcoal mixed with salt to a thickness of 150 mm connected by GI wire 4 mm dia at two points soldered and riveted to earth plate, GI earth wire protected by using 20 mm bore light grade GI pipe, watering pipe GI 20 mm dia medium grade 2.5 mtr long with funnel, wire mesh etc. necessary earth/brick work and PCC work, disposal of surplus soil to a distance not less than 50 metre, chamber of PCC (1:4:8) type D2 using 40 mm graded stone aggregate, coping in PCC (1:3:6) type C1 using 20 mm graded stone aggregate,
28RCC pit cover 50 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate, reinforced with 8 mm MS bar at 80 mm C/C both way, flame funnel wire mesh, testing on completion all as specified and as shown in electrical plate No 3 of MES SSR Part-1 2009 complete all specified and as directed. Note:- Quantity of GI earth wire & protection pipe beyond 7.5mtrs length shall be measured and paid separately.
29Material and labour for point wiring with 2.5 Sq. mm (nominal area) PVC insulated and unsheathed single core FRLSH/FRLS copper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 2.5 Sq mm PVC insulated and unsheathed single core HRFR/FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one 3 pin socket outlet/power point 15 Amps controlled by one switch complete all as specified and as directed.
30Supply and fixing LED bulb 7 watt , 6500K complete all as specified and as directed.
31Supply, installation, testing and commissioning of integral driver LED security light(Bldg security light) with a nominal system lumen output of 4500 lm. The luminaire shall have rated system lifetime of 50000 burning hours. The luminaire should have cool white colour temperature (CT>5700K + 300K) and CRI > 70. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with weather proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP65 protection, input voltage 140-270V, PF>0.95 the total power consumption should not exceed 45W (including driver) complete all as specified and as directed.
32Supply and fixing MCB SPN 6-32 Amps, single phase, 240 volts including making connection complete all as specified and as directed.
33Supply and fixing MCB SP 6-32 Amps, single phase, 240 volts including making connection complete all as specified and as directed.
34Supply and fixing double door metalic sheet metal enclosure for DB when MCBs to be used SPN 6 ways, IP 43, IK 09 protection, 240 volts with 200 Amps rated bus bar complete fixed properly on in concealed position including connection with existing sub circuits, electric meter etc with proper size copper cable, lugs connectors etccomplete all as specified and as directed.
35EXTERNAL ELECTRIC SUPPLY
36Material and labour for disconnecting, shifting, re-installation and commisioning of existing Sub-Station Transformer of capacity 100 KVA from Sub Station "C" to proposed sub station "C" complete all as specified and directed.
37Material and labour for disconnecting, shifting, re-installation and commisioning of HT 11 KV, 3 Phase, 50 Hz VCB rated 400 Apms (3 Nos of one incomer and two outgoings) from Sub Station "C"to proposed Sub Station "C" complete all as specified and directed.
38Material and labour for Cutting/ Demolition of PCC/Hard Standing Plinth Protection/WBM Road not exceeding 20 cm in width and not exceeding 30 cm in depth for passing ofLT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e. bitumen/PCC 1:3:6 type C1 complete all as specified and as directed.
39Supply, installing, testing and commissioning of factory fabricated LT panel board, indoor type, floor mounted, cubical design type, lock and hood on top and centre opening, double door with locking arrangement, made out of 2 mm thick CRCA sheet as per IS & IP protection IP 54, CPRI approved, with bus bar compartments and including copper bus bars, four strips colour coded for each phase of rating 250 Amps for phase and half for neutral, mounted on hygroscopic / epoxy coated insulators and necessary copper stranded conductor control wiring, cable gland etc. compartmental MCB, mounted on angle iron frame anti rust painted 50 mm x 50 mm x 6 mm of height 0.60 m above ground level and 0.6 m below ground level totally enclosed & completely weather, dust and vermin proof,
40cable in/out holes, suitable for 3 phase 4 wire, 415 volts, 50 Hz, AC supply, cable glands duly powder coated panel, PCC foundation 1:2:4 type B2 using 20 mm graded stone aggregate including necessary earthwork & excavation etc. and comprising of the following items with all clearance as per IE rule complete all as specified and as directed :-
41(i) MCCB, 4 Pole, 100 Amps, 25 KA, 415 volt, Three phase, AC, 50 Hz - 01 Nos (incoming)(ii) MCCB, 4 Pole, 25 Amps, 16 KA, 415 volt, Three phase, AC, 50 Hz - 02 Nos (for LT Panel 1 and Panel 2) (iii) MCCB, 4 Pole, 16 Amps, 16 KA, 415 volt, Three phase, AC, 50 Hz - 04 Nos (for periphery lights 2 Nos and Spare 2 Nos) (iv) Phase indicator lamp LED type R Y B - 01 set of three (v) Hand operated on load change over switch 415 Volts in sheet metal enclosure 63 Amps, 4 Pole - 01 Nos
42Supply, installing, testing and commissioning of factory fabricated LT panel board, outdoor type, floor mounted, cubical design type, lock and hood on top and centre opening, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet as per IS & IP protection IP 54, CPRI approved, with bus bar compartments and including copper bus bars, four strips colour coded for each phase of rating 250 Amps for phase and half for neutral, mounted on hygroscopic / epoxy coated insulators and necessary copper stranded conductor control wiring, cable gland etc. compartmental MCB, mounted on angle iron frame anti rust painted 50 mm x 50 mm x 6 mm of height 0.60 m above ground level and 0.6 m below ground level totally enclosed & completely weather, dust and vermin proof,
43cable in/out holes, suitable for one phase 2 wire, 240 volts, 50 Hz, AC supply, cable glands duly powder coated panel, PCC foundation 1:2:4 type B2 using 20 mm graded stone aggregate including necessary earthwork & excavation etc. and comprising of the following items with all clearance as per IE rule complete all as specified and as directed :-
44(i) MCCB, 4 Pole, 25 Amps, 16 KA, 415 volt, three phase, AC, 50 Hz - 01 Nos (incoming) (ii) MCB, SPN, 16 Amps, 240 volt, single phase, AC, 50 Hz - 06 Nos (For igloo No, 12, 13, 14 and 15 and Spare 2 Nos) (iii) Phase indicator lamp LED type R Y B - 01 set of three
45Material and labour forearthing complete with GI mild steel earth plate electrode 600mm X 600mm X 6 mm thick, burried directly in ground veritcally (Earth pit not less than 2.25 metre deep below ground level) with top edge of the earth plate not less than 1.5 metres below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and earth plate connected to GI strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of steel and riveted to earth plate at one end and connected to metallic bodies of equipment etc. at other end, earth strip encased in and
46including 40mm bore GI lightgrade pipe with all fitting from top of electrode to the body of equipment fixed with and including 25 x 4mm flat iron clamps, bolts, nuts and washer and also including GI pipe 20 mmlight grade for watering from bottom of earth pit to top of electrode including GI funnel with wire mesh all as shown in electrical plate No. 3 including PCC pit (1:3:6) type C1 in cement concrete 40mm thick precast RCC cover in (1:2:4) type B1 reinforced with 8mm dia TMT bars @ 75 c/c both ways with 01 No lifting handle of 12mm dia MS plain bar, etc. complete all as specified and as directed. NOTE : Quantity of GI strip/ protection pipe beyond 7.5mtrs length shall be measured and paid separately.
47ROAD/PATH/CULVERT/FIREBREAK
48Material and labour for Granular sub base (GSB) 200mm thick Compactedand conforming to the grading given in Table 400-1 and physical requirement given in Table 400-2, Grading Zone III and IV in Table 400-1 as per MORTH specification and laid in two layers (each layer of 100mm compacted thickness) by using shingle or gravel spread, rolled and consolidated to a gradient and camber complete all as specified and as directed.
49Material and labour for 150mm WMM in two layers (each layer of 75mm)conforming to the gradinggiven in Table 400-13 and physical requirement as per Table 400-12,spread with mechanical means and rolled using 8-10 Tonne vibratory power roller over compacted sub grade surface as specified in clause 406.3.5 on page 134-135 MORTH specification complete all as specified and as directed.
50Material & Labour for providing PCC 1:3:6 type C1 (20mm graded stone aggregate) as kerb stone of size 35cm x 30cm x 15cm, long set in cement mortar 1:6 in line complete including necessary earth work in any type of soil to fix in position all as specified and as directed.
51Material and labour for 150mm thick PCC M-25 design mix using 20mm graded stone aggregate as in flooring using tremix vacuum dewatering method including all necessary equipments for finishing the floor using tremix method complete all as specified and as directed.
52Material and labour for preparing surface of unsurfaced WMM surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc. and applying evenly a priming / tack coat with cold emulsion primer with cationic bitumen RS Grade-I (using paving bitumen) at the rate of 10 Kg per 10 Square metre of road surface as per manufacturers instructions complete all as specified and as directed.
53LIGHTENING PROTECTION
54Material and labour forearthing complete with GI mild steel earth plate electrode 600mm X 600mm X 6 mm thick, burried directly in ground veritcally (Earth pit not less than 2.25 metre deep below ground level) with top edge of the earth plate not less than 1.5 metres below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and earth plate connected to GI strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of steel and riveted to earth plate at one end and connected to metallic bodies of equipment etc. at other end, earth strip encased in and
55including 32mm bore GI lightgrade pipe with all fitting from top of electrode to the body of equipment fixed with and including 25 x 4mm flat iron clamps, bolts, nuts and washer and also including GI pipe 20 mmlight grade for watering from bottom of earth pit to top of electrode including GI funnel with wire mesh all as shown in electrical plate No. 5 including PCC pit (1:3:6) type C1 in cement concrete 40mm thick precast RCC cover in (1:2:4) type B1 reinforced with 8mm dia TMT bars @ 75 c/c both ways with 01 No lifting handle of 12mm dia MS plain bar, etc. complete all as specified and as directed. NOTE : Quantity of GI strip/ protection pipe beyond 7.5mtrs length shall be measured and paid separately.
56Supply, erection in true vertical position and fixing of steel tubular LT poles,swaged , welded complete with CI base plate 6 mm thick of size 300 mm x 300 mm, finial taper plugpole cap, bolts and nuts and screws as per IS - 2713 (Pt-II)made out of ERW MS tubing with including drilling of holes of required size &Nos for fixing cross arms and 2 Nos holeson bottom & top of pole for insertion of cableincluding painting with two coat of aluminium paint over one coat ofprimer for exposed surface and two coats of bituminious paint for embeded portion in concrete, painting three bue bands at lower porion of pole of 300 mm height at 300 mm spacing, painting Pole No with black paint at suitable heightcomplete of type 410 SP-64 (12 mtrs long)all as specified and as directed.
57Supply and fixing [post insulator epoxy LV type suitable for holding aluminium strip 25 x 4 mm conductor fixed on wall / roof / pole including screwcomplete all as specified and as directed.
58Supply and fixing single pointed air termination aluminium rod, 12 mm dia 600 mm long complete all as specified and as directed.
59STATIC DISCHARGE
60Material and labour forearthing complete with copper earth plate electrode 600mm X 600mm X 3 mm thick, burried directly in ground (Earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip 20x3 mm as earth lead by means of bolts, nuts, check nuts and washers of copper or brass connected to earth test point including watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode and 40 mm bore light grade GI Pipe protection pipe up to 7.5 Mtr from earth strip complete with wire mesh, funnel, necessary excavation and earth work in any type of soil/ strata, PCC chamber in 1:3:6 type C1, 550mmx550mmx50mm including CI cover 10 mm thick hinged to CI frame, complete all as shown in electrical plate No 3 and all as specified and or indicated including testing on completion complete all as specified and as directed.
61NOTES :- (a) Quantity of copper strip/ protection pipe beyond 7.5mtrs length shall be measured and paid separately. (b) On testing, after completion, if the earth resistance < 5 ohms is not obtained, earthing shall be rejuvenated at no extra cost till the desired earth resistance is obtained.
62Supply and fixing post insulator epoxy LV type suitable for holding aluminium air termination rod 12 mm dia fixed on stand post including screws complete all as specified and as directed.(Note : Insulator spacing is 0.5 metre)
63EXTERNAL WATER SUPPLY
64Supply and laying in trenches, jointing and testing of ductile iron pipe of size 100 mm dia of bore with spigot and socket ends, centrifuglly cast, class K-9 in any length conforming to IS-8329 with required jointing and fittings material such as rubber packing, nut and bolts along with washers etc, complete all as specified and as directed. Note: Joints will be measured and paid separately.
65Material and labour for fittings for DI pipe of size upto 150mm dia of bore conforming to IS-9523, socket / spigot socketed pipe such as bends (any type radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc) T-pieces, single branch Y junction, double branch cross (all socket or socket and spigot) reducer in required length, collar cap and plug etc with cutting / welding/ jointing / bolting etc complete all as specified and as directed.
66Material and labour for rubber joints, jointing for ductile iron pipe of size 100 mm dia of bore with spigot and socket ends, centrifugally cast, class K-9 in any length, complete all as specified and as directed.
67Supply and laying of 100 mm bore, cast iron sluice valve both end flanged, class PN 1.0 conforming to IS-14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber / fiber board gasket complete all as specified and as directed.
68Material and labour for cutting existing 200 mm CI pipeline and providing T-joint of size 200 x 200 x 100mm dia for taking a branch CI pipeline of 100mm dia from existing 200mm CI pipeline complete all as specified and as directed.
69Material and labour for valve chamber 900 x 900 x 900 mm (internal) with fly ash brick masonry 230 mm thick in cement mortar 1:6, PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) foundation 75 mm thick finished fair and even, PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), MS cover 3 mm thick including MS angle iron 40x40x6 mm size frame fixed to PCC coping with same size of angle iron hold fast and with necessary handle and locking arrangement, metal surfaces duly painted with black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surface with 3 coats of white wash including necessary excavation and earthwork complete all as specified and as directed.
70EXTERNAL SEWAGE DISPOSAL
71Construction of RCC Hume Pipe septic tank for 10 users including excavation in any type of soil, PCC 1:4:8, Type D2 below foundation, vent shaft , connection etc. complete all as specified and as directed.
72Construction of soakage well with excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber, screen chamber made up of brickwork in CM 1:4, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete of size 1.2mdia x 3.0m effective depth complete all as specified and as directed.
73Total amount of Schedule "A" Part XIV carried over to General Summary
74Blank
75Blank
76Blank
77GENERAL SUMMARY
78Lumpsum price worked out by the contractorfor “BUILDINGS & STRUCTURES” as listed inSchedule ‘A" Part I representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part I on Srl Page No. 33
79Lumpsum price worked out by the contractorfor “SITE CLEARANCE, EXCAVATION AND EARTH WORK (FOR SCHEDULES OTHER THAN SCHEDULE "A" PART-I)” as listed inSchedule ‘A" Part II representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part II on Srl Page No. 36
80Lumpsum price worked out by the contractorfor “DEMOLITION OF BUILDINGS” as listed inSchedule ‘A" Part III representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part III on Srl Page No. 38
81Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A" Part IV above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part IV on Srl Page No. 41
82Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A" Part V above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part V on Srl Page No. 43
83Lumpsum price worked out by the contractor for “ROAD/ PATH/ CULVERT/ FIRE BREAK” as listed in Schedule ‘A"Part VI representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VI on Srl Page No. 48
84Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A" Part VII representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VII on Srl Page No. 50
85Lumpsum price worked out by the contractor for “COMPOUND WALL, FENCING & GATE” as listed in Schedule ‘A" Part VIII representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VIII on Srl Page No. 55
86Lumpsum price worked out by the contractor for “EXTERNAL SEWAGE DISPOSAL” as listed in Schedule ‘A" Part IX representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IX on Srl Page No. 58
87Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A" Part X representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part X on Srl Page No. 59
88Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A" Part XI above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part XI on Srl Page No. 62
89Lumpsum price worked out by the contractor for “STATIC DISCHARGE” as listed in Schedule ‘A" Part XII representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part XII on Srl Page No. 63
90Lumpsum price worked out by the contractorfor “LIGHTENING PROTECTION” as listed in Schedule ‘A"Part XIII representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part XIII on Srl Page No. 66
91Total amount of SCHEDULE "A" PART XIV (MISC B/R & E/M ITEMS) brought forwarded from Serial Page No. 95