}

Tender For Civil And Allied Works-2 Kota Stone Flooring Providing And Laying Machine Cut Machine Polished Kota Stone Flooring 25Mm To 30Mm Thick Andrequiredwidthinplain/Diamondpatternonbedof1:6C.M.Including Cementfloat, Filling Joints With Neat Cement Slu, chandrapur-Maharashtra

District Collector-DC has published Tender For Civil And Allied Works-2 Kota Stone Flooring Providing And Laying Machine Cut Machine Polished Kota Stone Flooring 25Mm To 30Mm Thick Andrequiredwidthinplain/Diamondpatternonbedof1:6C.M.Including Cementfloat, Filling Joints With Neat Cement Slu. Submission Date for this Tender is 23-02-2024. Stone Flooring Tenders in chandrapur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42225679
Corrigendum : Tender For Civil And Allied Works-2 Kota Stone Flooring Providing And Laying Machine Cut Machine Polished Kota Stone Flooring 25Mm To 30Mm Thick Andrequiredwidthinplain/Diamondpatternonbedof1:6C.M.Including Cementfloat, Filling Joints With Neat Cement Slu
Open Tender
Indian
Maharashtra
chandrapur
23-02-2024

Tender Details

Tender For Civil And Allied Works-2 Kota Stone Flooring Providing And Laying Machine Cut Machine Polished Kota Stone Flooring 25Mm To 30Mm Thick And Required Widthin Plain / Diamond Pattern On Bedof1:6C.M.Including Cement Float, Filling Joints With Neat Cement Slurry, Curing, Polishing And Cleaning Etc. Complete.25 Mm Thick 3 Ms Front Sliding Gate- 2Nosexcavation For Foundation In Earth, Soil Of All Types, Sand, Gravel And Soft Murum, Including Removing The Excavated Material Upto Adistance Of 50M.Beyondthe Building Area And Stacking And Spreading As Directed, Dewatering, Preparing The Bed For The Foundation And Necessary Back Filling, Ramming, Watering Including Shoring And Strutting Etc. Complete. ( Lift Upto 0.00 To 1.50 M. ) By Manual Means 4 Ms Front Sliding Gate- 2Nos Providing And Laying Casti Nsitu / Ready Mix Cement Concrete In M-10Oftrap / Granite / Quartzite / Gneissmetalforfoundationandbeddingincludingbailingoutwater, Steel Centering, Formwork, Laying / Pumping, Compacting, Roughening Them If Special Finish Is To Be Provided, Finishingifrequiredandcuringcomplete, Withfullyautomaticmicroprocessor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete.With Fine Aggregate ( Crushed Sand Vsi Grade ) 5 Ms Front Sliding Gate- 2Nosprovidingdry / Trap / Granite / Quartzite / Gneissrubblestonesoling15cmto20cmthick Including Hand Packing And Compacting Etc. Complete. 6 Ms Front Sliding Gate- 2Nosprovidingandlayingcastinsitu / Readymixcementconcretem-25Oftrap / Granite / Quartzite / Gneissmetalforr.C.C.Workinfoundationslike Raft, Strip Foundations, Grillage And Footings Of R.C.C. Columns And Steel Stanchions Etc. Including Bailing Out Water, Steel Centering, Formwork, Coverblocks, Laying / Pumping, Compactionandcuring Roughening The Surface If Special Finish Is To Be Provided ( Excluding Reinforcement And Structural Steel ) Etc. Complete, With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 7 Ms Front Sliding Gate- 2Nosprovidingandlayingcastinsitu / Readymixcementconcretem-25Oftrap / Granite / Quartzite / Gneissmetalforr.C.C.Columnsasperdetaileddesignsanddrawingsoras Directedincludingsteelcentering, Formwork, Coverblocks, Laying / Pumping, Compaction Finishing The Formed Surfaces With Cement Mortar 1:3 Of Sufficient Minimum Thickness To Give A Smoothand Even Surface Or Roughening If Special Finish Is To Be Providedand Curing Etc. Complete, ( Excluding Reinforcement And Structural Steel ) .With Fully Automatic Micro Processor Based Plc With Scada Enabled Reversible Drum Type Mixer / Concrete Batch Mix Plant ( Pan Mixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 8 Ms Front Sliding Gate- 2Nosprovidingandlayingcastinsitu / Readymixcementconcreteinm-25Oftrap / Granite / Quartzite / Gneiss Metal For R.C.C. Beams And Lintels As Per Detailed Designs And Drawings Or As Directed Including Steel Centering, Formwork, Cover Blocks, Laying / Pumping, Compactionand Roughening The Surface If Special Finish Is To Be Provided And Curing Etc. Complete. ( Excluding Reinforcementandstructuralsteel ) .Withfullyautomaticmicroprocessorbasedplcwith Scadaenabledreversibledrumtypemixer / Concretebatchmixplant ( Panmixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 9 Ms Front Sliding Gate- 2Nosproviding Fly Ash Brick Masonry With Conventional / I.S. Type Bricks In Cement Mortar 1:6 In Superstructureincludingstrikingjoints, Rakingoutjoints, Wateringandscaffoldingetc. Complete 10 Ms Front Sliding Gate- 2Nosprovidingandlayingcastinsitu / Readymixcementconcreteinm-20Oftrap / Granite / Quartzite / Gneiss Metal For R.C.C.Coping To Plinth Or Parapet And Sill Of Doors And Windows Moulded As Per Detailed Drawings Or Chamfered As Approved By The Engineer Including Steel Centering, Formwork, Coverblocks, Laying / Pumping, Compacting, Curing, Finishingand Rougheningthemifspecialfinishistobeprovidedandcuringcomplete. ( Excluding Reinforcementandstructuralsteel ) .Withfullyautomaticmicroprocessorbasedplcwith Scadaenabledreversibledrumtypemixer / Concretebatchmixplant ( Panmixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) 11 Ms Front Sliding Gate- 2Nosproviding And Fixing In Position Tmt - Fe - 500 Bar Reinforcement Of Various Diameters For R.C.C.Pilecaps, Footings, Foundations, Slabs, Beamscolumns, Canopies, Staircase, Newels, Chajjas, Lintelspardis, Copings, Fins, Archesetc.Asperdetaileddesigns, Drawingsand Schedules. Including Cutting, Bending, Hooking The Bars, Binding With Wires Or Tack Welding And Supporting As Required Complete. 12 Ms Front Sliding Gate- 2Nosproviding And Fabricating Structural Steel Work In Rolled Sections Like Joists, Channels, Angles, Teesetc.Asperdetaileddesignanddrawingsorasdirectedincludingcutting, Fabricating, Hoisting, Erecting, Fixinginpositionmakingriveted / Bolted / Weldedconnectionswithout Connecting Plates, Braces Etc. Andincluding One Coat Of Anticorrosive Paint Andover Ittwo Coats Of Oil Painting Of Approved Quality And Shade Etc. Complete. 13 Ms Front Sliding Gate- 2Nosproviding Sand Faced Plaster Externally In Cement Mortar Using Approved Screened Sand, In All Positionsincludingbasecoatof15mmthickincementmortar1:4Usingwaterproofing Compound At 1Kilogramper Cement Bag Curing The Same For Not Less Than 2 Days And Keeping Thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm Thickin Cementmortar1:4Finishingthesurfacebytakingoutgrainsandcuringforfourteendays Scaffolding Etc.Complete. 14 Ms Front Sliding Gate- 2Nosproviding And Applying Two Coats Of Water Proof Cement Paint Of Approved Manufacture And Of Approved Colour To The Plastered Surfaces Including Scaffolding If Necessary, Cleaning And Preparing The Surface, Watering For Two Days Etc.Complete. 15 Ms Front Sliding Gate- 2Nosproviding And Applying Two Coats Of Synthetic Enamel Paint Of Approved Colour To New / Old Structural Steel Work And Wood Work In Buildings, Including Scaffolding If Necessary, Cleaning And Preparing The Surface ( Excluding Primer Coat ) Etc. Complete. 16 Ms Front Sliding Gate- 2Nosfillinginplinthandfloorswith Approved Excavatedmaterialin15cm.To20cm.Layers Including Watering And Compacting Etc. Complete. 17 Ms Front Sliding Gate- 2Nosconstruction Of Granular Sub-Base By Providing Close Graded Material, Spreading In Uniform Layers With Motor Grader / Paveron Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Clause 401 -- By Mix In Place Method And Grading - I Material 18 Ms Front Sliding Gate- 2Noswet Mix Macadam -- Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mix Plant Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers With Paver In Sub- Base / Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Achieve The Desired Density. Laying By Grader / Paver. 19 Ms Front Sliding Gate- 2Nosproviding And Applying Tack Coat On The Prepared Surface Heating By Fames In Boiler And Spraying Bitumen Set Footed In Bitumen Boller On B.T. Surface 2.5 Kg / 10 Sqm. ( Vg-30 Bulk Bitumen Rates Are Considered To Arrive At Rates ) On W.B.M. @ 0.75 Kg / Sqm 20 Ms Front Sliding Gate- 2Nosproviding And Applying Tack Coat On The Prepared Surface Heating By Fames In Boiler And Spraying Bitumen Set Footed In Bitumen Boller On B.T. Surface 2.5 Kg / 10 Sqm. ( Vg-30 Bulk Bitumen Rates Are Considered To Arrive At Rates ) On Bituminous Surface @ 0.50 Kg / Sqm 21 Ms Front Sliding Gate- 2Nosproviding And Applying Tack Coat On The Prepared Surface Heating By Fames In Boiler And Spraying Bitumen Set Footed In Bitumen Boller On B.T. Surface 2.5 Kg / 10 Sqm. ( Vg-30 Bulk Bitumen Rates Are Considered To Arrive At Rates ) Dense Bituminous Macadam:--Providing And Laying Dense Bituminous Macadam Using Crushed Aggregate Of Grading 1, Premixed With Bituminous Binder Bitumen Of Specified Grade, @ 4.50 % By Weight Of Total Mix And Filler, Transported At Site With Vts, Laid Over A Previously Prepared Surface , Finished To The Required Grade , Level, Alignment, And Rolling To Achieve The Desired Density For 76 / 100 Mm Compacted Thickness With Drum Mix Type Hot Mix Plant With Scada Having Complying Essential Features Of Hot Mix Plant As Per Irc-27-2009 Specified Conditions And Attachments Such As Electronic Load Sensor Based Belt Conveyers, Automatic Synchronization Of Bitumen And Aggregate Fedder, Built In Dust Controller System And Plc For Drum Mix Plant , Sensor Paver, And Vibratory Roller Excluding Prime / Tack Coat Etc. Complete --Bitumen Vg-30 Grade With Stone Dust Filler ( Vg-30 Bulk Bitumen Rates Are Considered To Arrive At Rates ) 22 Ms Fabrication Itemsproviding Structural Steel Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing, Gussetplatesetc.Asperdetaileddesignsanddrawingsoras Directedincluding Cutting, Fabricating, Hoisting, Erectingfixinginposition, Makingriveted / Bolted / Welded Connectionandone Coat Of Anticorrosive Paint Andover It 2 Coats Of Oil Painting Approved Quality And Shade Etc. Complete. 23 Ms Fabrication Itemsproviding And Fabricating Structural Steel Work In Rolled Sections Like Joists, Channels, Angles, Teesetc.Asperdetaileddesignanddrawingsorasdirectedincludingcutting, Fabricating, Hoisting, Erecting, Fixinginpositionmakingriveted / Bolted / Weldedconnectionswithout Connecting Plates, Braces Etc. Andincluding One Coat Of Anticorrosive Paint Andover Ittwo Coats Of Oil Painting Of Approved Quality And Shade Etc. Complete. 24 Ms Fabrication Itemsprovidingandfixingcorrugatedgalvanisedironsheetsof0.63Mmthick ( 24B.W.G. ) For Roofing Without Wind Tiles Including Fastening With Galvanised Iron Screws And Bolts, Lead And Bitumen Washers As Per Drawing Etc. Complete. ( Weight Of 5.5 Kilogram / Sq.M. ) . 25 Chain Link Fencing Providing And Erecting Chain Link Fencing 2.1 M. Height With G.I. Chain Link Of Size 50X 50 Mm, 8 Gauge Thick And Fixed 75 Mm Above Ground Level On Vertical M.S. Angles Of 40 X 40 X 6 Mm Size, Includind Excavating Pits For Foundation And Embedded In C.C. Block Of 1:4:8 Mix Of Size 450 X 450 X 670 Mm. At 1.75 M. C / C With Iron Bar 16Mm Dia As Hold Fast Including Welding Link With Angle Frame At 30 Cm C / C With Nuts And Bolts And Horizontal M.S. Angles At Top Andbottom Of 25 X 25 X 5 Mm Size Andvertical M.S. Flat 35 X 5 Mm And25 X 5Mm Horizontal Including Cross Support Of 40 X 40 X 6 Mm Angles Both Side At Every Corner Or Bend Embedded In Concrete Blocks Of 1:4:8Of Size 450 X 450 X 670 Mm Including 3 Coats Of Oil Painting Etc. Complete. 26 Antibacterior Food Grade Coating Inside Drinking Water Tank:-Providing And Applying A Base Coat Comprising Of 1Kilogrampolydee-Mc And 1Kilogramfresh Cement After Wetting The Surface Followed By Drying The Surface For 2 Days, Apply Primer Coat Of Tp-40 And After Drying, Applying Polydee-11 Two Component ( Mixing Ratio 2 A : 1 B ) ) Antibacterial Food Grade Coating Inside Drinking Water Tank In Two Coats With Time Interval Of Minimum 8 Hrs. Covering 7 Years Guarantee On Court Fee Stamp Paper Of Rs. 100 / - Etc. Complete. 27 Stainless Steel Railing At Porch And External Providing And Fixing 900Mm High S.S.304 Grade Stainless Steel Railing With 40Mm Diameter And1.5Mmthickattop, 40Mm Diameterand1.5Mm Thickverticalsupportsspacedat1.5M Centertocenterand8mmthicktoughenedglassincludingfabricating, Fixtures, Errecting, Necessary Welding , Grinding , Finishing, Buffing To Stainless Steel Pipe Etc. Complete 28 Connecting Bridge Of Façade At Gfdesign Wind Pressure ( Kg / M2 ) Proof Load At 1.5 Times Of Design Wind Pressure ( Kg / M2 ) Semi-Unitized Four Sided Structural Glazing ( Punch Windows & Strip Glazings ) Design, Fabrication, Supply, Installation, Testing, Protection, Cleaning & Handover Of Semi-Unitized Four Sided Structurally Glazed Curtain Wall System Custom Designed To Withstand The Design Wind Pressure Confirming To Is-875 Part Iii. ( The System Must Pass The Proof Test At 1.5 Times Design Wind Pressure Without Any Failure ) With Microwave Cured Epdm Gaskets, Structural & Weather Sealants, Open Pu Cell Spacer Tape, Backer Rod, Bracketing System With Ms Hot Dip Galvanized / Aluminium Alloy Of 6005 T5brackets Designed To Accommodate Three Dimensional Movements With Serrated Plate And Serrated Washers, Building Plump Tolerances Upto 50Mm, Ss 316 Grade Fasteners & Anchor Fasteners, Nylon Separators To Prevent Bi-Metallic Contacts, Aluminium Trims And Flashings To Seal The Gaps Between Curtain Wall And The Building Structure All Complete Required To Perform As Per Specification And Drawing In Conjunction With Boq. Transom Shall Be Overlap With Mullion To Have Proper Drainage To Mullion. The Design To Accommodate Building Movements, Thermal Expansions & The Seismic Movements. The System Shall Be Designed Considering Surface Temperatures Of 80°C-90°C & Temperature Differential Of 25°C Without Creating Excess Stress In The System. All Metal Joints In The Wet Area Shall Be Small Joint Sealant Applied To Ensure Water Tightness. The System Shall Be Designed Of Floor Height Units Spanning Between The Floors With Face / Slab Mounted Brackets Or Hook-On Bracket On Mullion With Provision To Accommodate Movement At All Floor Levels And At Every Grid Panels Horizontally. System Shall Be Mounted On To The Bracket Arrangement With The Help Of Ss316 Anchor Fastener. The Bracketing System With Aluminium Alloy / Ms Hdg With Built In Serration & Serrated Washers. The System Shall Be Designed To Accommodate 24Mm Igu In Vision Area & 6Mm Sgu In Spandrel Area At All Floor Level. The Spandrel Panel Shall Have Aluminium Adaptor Profile To Balance The Dgu And Sgu Glass Thickness In Black Anodized. System Shall Accommodate Openable Panel As Per Architectural Requirement In The Semi-Unitized System. All Fix Vision Glass And Openable Shall Look Similar In The Elevation. Aluminium Edge Guard Shall Be Fixed At All Vertical & Horizontal Grooves. Each Glass Panel Shall Be Structurally Glazed On The Main System . Each Glass Panel Shall Be Supported For Dead Load At The Bottom Of Glass With Black Anodized Glass Retainers Two Per Panel. System To Have Provision To Accommodate Openable Panels As Per The Architectural Intent. System To Have Provision To Accommodate Fibre Cement Board For Lower Pane As Per The Façade Tender Drawings. Flashing / Trim / Floor Closure At Parapet Level, Floor Level, Beam Bottom Level And Required Flashings Shall Be Provided Continuously With Required Gi / Aluminium Sheet. Internal & External Concealed Flashings Shall Be 1.0Mm Thk Gi Sheet. External Exposed Flashing Shall Be 2.5Mm Thk. Internal Exposed Flashing Shall Be 2Mm Thk. Aluminium Sheet Shall Be Coated Matching With Respective Areas Aluminium Profiles. The Extruded Aluminium Sections Of Alloy 6063 T5 / T6 & Tolerances Confirming To Din / En Standard From Approved Extruder. All The Visible Surfaces Shall Have Super Durable Powder Coating Of 60 - 80 Micron Confirming To Aama 2604. The Non Visible Aluminium Surfaces Shall Have Minimum Chromatizing Treatment.All Material Make / Vendor List / Supplier List Shall Be As Per Tender Specification. ( Annexure 1 ) .Acceptance Of Equivalent Makes Is Subject To Prior Approval From Client / Pmc / Architect / Consultant. All Shade Approval Shall Be As Per Client / ArchitectS Approval. The Quote Rate Shall Include All Design, Engineering & Shop Drawing Approval From Architect, Consultant & Client. The Quote Rate Shall Include Loading, Unloading, All Taxes, Duties, Statutory Obligations And Safety Code Compliance As Per Client.Semi-Unitized Structural Glazing Curtain Wall System Quote Rate For Complete System As Mentioned Above Under ( A ) 29 Connecting Bridge Of Façade At Gfvision Glass Gl1 : 24Mm Thick Dgu ( Middle Pane ) Providing & Fixing The Vision Glass On The Semi-Unitized Panel6mm Thick Ref. Hs + 12Mm Thick Air Gap + 6Mm Thick Clear Hsappearance - Greyvlt - 35-50%, Shgc < 0.25, U-Value - 1.8W / M2k 30 Connecting Bridge Of Façade At Gfspandrel Glass : 6Mm Sgu ( Top Pane ) Providing & Fixing The Spandrel Glass On The Semi-Unitized Panel6mm Ref. Hsappearance To Match With Gl1 31 Connecting Bridge Of Façade At Gfspandrel Panel: Extra Over A.1 Quote Extra Over On Item ( A.1 ) For Providing And Fixing The Spandrel Panel With The Glasswool Insulation Of 50Mm Thick 48 Kg / M3 Density Slab With Inbuilt Black Veil Of 0.65Mm Firmly Held On The Gi Tray Of 2Mm Thk. The Assembly Is Kept Atleast 50Mm Away From The Glass Surface. 32 Frosted Filmsupply & Installation Of Crystal Glass Film, Having Frosted Or Dusted Effect, With Approved Artwork, Lettering Or Pattern, Cut Using Digital Plotter Along With Printing With Water Based Inks Certified To Have No Hazardous Air Pollutants. Film To Be Self-Adhesive And Bubble-Free. Installation To Be Done On Clean Glass By Authorised Installers Only As Recommended By Manufacture.Warranty For A Period Of 120 Months For Interior Application. Rate Including Design As Per Requirment.Approved Make: 3M. Lumar, Avery Dennision 33 False Flooring Supply And Installation Of Vinyl Posters Of Approved Shade With Recommended Adhesive Of Approved Make And Sample As Per ManufacturerS Specifications. Cost To Include Preparation On The Punned Surface For Receiving The Poster As Per The Manufacturer Specification. Including Design Approved Make: 3M / Avery Dennison Or Equivalent 34 False Flooring Providing And Fixing Steps For False Flooring With Treads Of Width 300Mm And Risers As 150Mm Using 19Mm Thick Marine Plywood Boxing With Necessary Hardwood Framework 50Mm X50mm At The Corners With Necessary Supports At Edges Or As Directed. The Exposed Edges Of The Steps To Be Finished In Anti-Static Laminate Of Approved Make And Sample. 35 External Paint On Existing External Texturepainting And Applying Exteriorpaint On Texture Pattern And Shade / Colour Of Paint To The Exterior Walls / Ceiling / Rcc Surfaces / Any Other Location As Desired By The Eic After Preparation Of The Wall / Rcc Surfaces To The External Surfaces Of The Building, Filling In Cracks With Approved Putty, Min Onecoats Of Exterior Grade Paint Including Scaffolding, Preparing The Surface, Curing, Primer Coat Etc Complete. Final Coat Paint Should Be Done Before Handing Over. 36 Internal Texturepaint Providing And Applyingpaint Of Approved Shade & Colurof Oikos Or Equivalent On Internal Wall Surfaces Wherever Required At All Heights To Give An Even And Uniform Shade, Applied Over 2 Coats Of Primer And Putty Of Approved Make As Per Manufacturer Specification Fully To Give A Smooth And Even Surface Including Thoroughly Brushing The Surface Free From Water / Mortar Dropping And Other Foreign Matter And Sand Papered Smooth, Complete Per Manufacturers Specifications And As Directed ( Including Texture ) 37 Apex Ultima Paint For External Surfaces Providing And Applying Onecoats Apex Ultima Puranature Anti-Pollution Or Equivalent Approved Brand, Paint Should Decomposes Organic Substances And Inorganic Gases ( Nox, Voc’S, Co, Sox, Formaldehydes, Etc. ) In Presence Of Natural Or Artificial Light. It Contains Graphene And Nanoparticles Of Titanium Oxide. And Absorbs Co2 ( 4.8 Kilogram / 15 L ) . Plaster Crack Should Be Filled By Acrylic Base Crack Seal / Textured Crack Filler, Paint Has To Applied On One Coat Of Apex Ultima Puranature Anti-Pollution Primer Or Equivalent. Warranty Should Be Given By The Manufaturer The Work Should Be Done By The Manufacturer Recommended Applicator And He Should Be Able To Furnish Stage Wise Onsite Technical Reports From The Concerned Company Technologist. Including Scaffolding For All Height. 38 Aluminium Composite Panelsupply, Fabricating, Installation And Fixing In Position Aluminium Panel With One Side Film Faced Marine Plywood Backing, With Open Grooves For Linear As Well As Curvilinear Portions Of The Building, For Roof Levels Etc. As Shown In The Drawings Including:A ) Structural Analysis & Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design.B ) Providing, Fabricating And Supplying And Fixing Panels Of Aluminiumpanel Cladding In Pan Shape In Metalic Colour Of Approved Shades Made Out Of 2Mm Thick Aluminium Panel. The Aluminiumpanel Cladding Sheet Shall Be 50 Microns Thick Powder Coating Of Approved Colour And Shade On Face # 1 And Polymer ( Service ) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc.C ) The Fastening Brackets Of Aluminium Alloy 6063 T56 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing. The Item Includes Cost Of All Material & Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individualcomponents For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminiumpanel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminiumpanel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work Foraluminium Cladding Is Payable Under The Relevant Aluminium Item.S The Contractor Shall Provide Curtain Wall With Aluminium Panel Cladding, Having All The Performance Characteristics All Complete , As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer-In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Panel Cladding ( Including Width Of Groove ) Shall Be Measured In Sqm. Up To Two Decimal Places. 39 Concertina Coil Fencing Providing And Fixing Concertina Coil Fencing With Punched Tapeconcertina Coil 600 Mm Dia 10 Metreopenable Length ( Total Length90 M ) , Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Ofwall With Existing Angle Iron Y Shaped Placed 2.4M Or 3.00 M Apartand With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape ( R.B.T. ) / Spring Core ( 2.5Mm Thick ) Wire Of High Tensile Strength Of 165 Kg / Sq.Mm With Tape ( 0.52 Mm Thick ) And Weight 43.478 Gm / Metre Includingm.S. Angle Of Size 50 Mm X 50Mm X 6Mm, Hilty Anchor Fastener, Ms Gussete Plateand C.C. Blocks, Etc Completed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Feb-2024 Corrigendum Other 20-02-2024
2 20-Feb-2024 date extenssion 1 Date 23-02-2024

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: F1. CIVIL AND ALLIED WORKS
Sl. No. Item Description
1F1. CIVIL AND ALLIED WORKS
2Kota Stone Flooring Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete. 25 mm Thick
3MS Front Sliding Gate- 2nos Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means
4MS Front Sliding Gate- 2nos ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)
5MS Front Sliding Gate- 2nos Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete.
6MS Front Sliding Gate- 2nos ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
7MS Front Sliding Gate- 2nos ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite /quartzite/gneissmetalforR.C.C.columnsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
8MS Front Sliding Gate- 2nos ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade)
9MS Front Sliding Gate- 2nos Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructureincludingstrikingjoints,rakingoutjoints,wateringandscaffoldingetc. Complete
10MS Front Sliding Gate- 2nos ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering,formwork,coverblocks,laying/pumping,compacting,curing,finishingand rougheningthemifspecialfinishistobeprovidedandcuringcomplete.(Excluding reinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade)
11MS Front Sliding Gate- 2nos Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
12MS Front Sliding Gate- 2nos Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete.
13MS Front Sliding Gate- 2nos Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.
14MS Front Sliding Gate- 2nos Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.complete.
15MS Front Sliding Gate- 2nos Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
16MS Front Sliding Gate- 2nos Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete.
17MS Front Sliding Gate- 2nos Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paveron prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - I Material
18MS Front Sliding Gate- 2nos Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver.
19MS Front Sliding Gate- 2nos Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates) On W.B.M. @ 0.75 Kg / sqm
20MS Front Sliding Gate- 2nos Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates) On bituminous surface @ 0.50 Kg / sqm
21MS Front Sliding Gate- 2nos Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates) DENSE BITUMINOUS MACADAM:--Providing and laying dense bituminous macadam using crushed aggregate of grading 1, premixed with bituminous binder Bitumen of specified grade,@ 4.50 % by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 76/100 mm compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC-27-2009 specified conditions and attachments such as electronic load sensor based belt conveyers, automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver, and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen VG-30 grade with stone dust filler (VG-30 bulk bitumen rates are considered to arrive at rates)
22MS Fabrication Items Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsoras directedincluding cutting,fabricating,hoisting,erectingfixinginposition, Makingriveted/bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete.
23MS Fabrication Items Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete.
24MS Fabrication Items Providingandfixingcorrugatedgalvanisedironsheetsof0.63mmthick(24B.W.G.)for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.).
25Chain Link Fencing Providing and erecting chain link fencing 2.1 M. height with G.I. chain link of size 50x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top andbottom of 25 x 25 x 5 mm size andvertical M.S. flat 35 x 5 mm and25 x 5mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete.
26Antibacterior Food grade Coating inside drinking water tank:- Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.
27Stainless Steel Railing at Porch and External Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and1.5mmthickattop, 40mm diameterand1.5mm thickverticalsupportsspacedat1.5m centertocenterand8mmthicktoughenedglassincludingfabricating,fixtures,errecting, necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
28Connecting bridge of Façade at GF Design Wind Pressure (kg/m2) Proof Load at 1.5 Times of Design Wind Pressure (kg/m2) Semi-Unitized Four Sided Structural Glazing (Punch Windows & Strip Glazings) Design, fabrication, supply, installation, testing, protection, cleaning & handover of Semi-unitized four sided structurally glazed curtain wall system custom designed to withstand the design wind pressure confirming to IS-875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with microwave cured EPDM gaskets, Structural & weather sealants, Open PU cell Spacer tape, backer rod, Bracketing system with MS hot dip galvanized / Aluminium Alloy of 6005 T5brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, building plump tolerances upto 50mm, SS 316 grade fasteners & Anchor fasteners, nylon separators to prevent bi-metallic contacts, Aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ. Transom shall be overlap with mullion to have proper drainage to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall be designed of floor height units spanning between the floors with face / Slab mounted brackets or hook-on bracket on mullion with provision to accommodate movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of SS316 Anchor fastener. The Bracketing system with Aluminium Alloy / MS HDG with built in serration & serrated washers. The system shall be designed to accommodate 24mm IGU in vision area & 6mm SGU in spandrel area at all floor level. The spandrel panel shall have aluminium adaptor profile to balance the DGU and SGU glass thickness in black anodized. System shall accommodate openable panel as per architectural requirement in the semi-unitized system. All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard shall be fixed at all vertical & horizontal grooves. Each glass panel shall be structurally glazed on the main system . Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel. System to have provision to accommodate openable panels as per the architectural intent. system to have provision to accommodate fibre cement board for lower pane as per the façade tender drawings. Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 2.5mm thk. Internal exposed flashing shall be 2mm thk. Aluminium sheet shall be coated matching with respective areas aluminium profiles. The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. All the visible surfaces shall have Super Durable Powder Coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1). Acceptance of equivalent makes is subject to prior approval from client / PMC / architect / consultant. All shade approval shall be as per client / architect"s Approval. The quote rate shall include all design, engineering & shop drawing approval from architect, consultant & client. The quote rate shall include loading, unloading, all taxes, duties, statutory obligations and safety code compliance as per client. Semi-Unitized structural glazing curtain wall system Quote rate for complete system as mentioned above under (A)
29Connecting bridge of Façade at GF Vision Glass GL1 : 24mm thick DGU (Middle Pane) Providing & fixing the vision glass on the semi-unitized panel 6mm thick Ref. HS + 12mm thick Air Gap + 6mm thick Clear HS Appearance - Grey VLT - 35-50%, SHGC < 0.25, U-Value - 1.8W/m2K
30Connecting bridge of Façade at GF Spandrel Glass : 6mm SGU (Top Pane) Providing & fixing the spandrel glass on the semi-unitized panel 6mm Ref. HS Appearance to match with GL1
31Connecting bridge of Façade at GF Spandrel panel: Extra over a.1 Quote extra over on item (a.1) for providing and fixing the spandrel panel with the Glasswool insulation of 50mm thick 48 kg/m3 density slab with inbuilt black veil of 0.65mm firmly held on the GI tray of 2mm thk. The assembly is kept atleast 50mm away from the glass surface.
32Frosted Film Supply & Installation of Crystal Glass Film, having Frosted or Dusted effect, with approved artwork, lettering or pattern, cut using digital plotter along with printing with water based inks certified to have no hazardous air pollutants. Film to be Self-adhesive and bubble-free. Installation to be done on clean glass by authorised installers only as recommended by manufacture. Warranty for a period of 120 months for interior application. Rate Including design as per requirment. Approved Make: 3M. Lumar, Avery Dennision
33False Flooring Supply and Installation of Vinyl Posters of approved shade with recommended adhesive of approved make and sample as per manufacturer"s specifications. Cost to include preparation on the punned surface for receiving the Poster as per the manufacturer specification. including design Approved Make: 3M / Avery Dennison or equivalent
34False Flooring Providing and fixing steps for false flooring with treads of width 300mm and risers as 150mm using 19mm thick marine plywood boxing with necessary hardwood framework 50mm x50mm at the corners with necessary supports at edges or as directed. The exposed edges of the steps to be finished in anti-static laminate of approved make and sample.
35EXTERNAL PAINT ON EXISTING EXTERNAL TEXTURE Painting and applying ExteriorPaint on Texture pattern and shade / colour of paint to the exterior walls / ceiling / RCC surfaces / any other location as desired by the EIC after preparation of the wall / RCC surfaces to the external surfaces of the building, filling in cracks with approved putty,min onecoats of exterior grade paint including scaffolding, preparing the surface, curing, primer coat etc complete. Final Coat Paint should be done before Handing Over.
36INTERNAL TEXTUREPAINT Providing and applyingpaint of approved shade & colurof oikos or equivalent on internal wall surfaces wherever required at all heights to give an even and uniform shade, applied over 2 coats of primer and putty of approved make as per manufacturer specification fully to give a smooth and even surface including thoroughly brushing the surface free from water / mortar dropping and other foreign matter and sand papered smooth, complete per manufacturers specifications and as directed (Including Texture)
37Apex Ultima Paint for External Surfaces Providing and applying onecoats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Including Scaffolding for all height.
38Aluminium Composite Panel Supply, fabricating, installation and fixing in position Aluminium Panel with one side film faced marine plywood backing, with open grooves for linear as well as curvilinear portions of the building, for roof levels etc. as shown in the drawings including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminiumpanel cladding in pan shape in metalic colour of approved shades made out of 2mm thick aluminium panel. The aluminiumpanel cladding sheet shall be 50 microns thick powder coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6063 T56/ MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminiumpanel cladding, cleaning and protection of the curtain wall with aluminiumpanel cladding till the handing over of the building for occupation. Base frame work foraluminium cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
39Concertina Coil Fencing Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metreopenable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron "Y" shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre IncludingM.S. angle of Size 50 mm x 50mm x 6mm, hilty anchor fastener,MS Gussete plateand C.C. blocks,etc completed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail