Himachal Pradesh State Electricity Board-HPSEB has published Tender For Supply Ofmaterial, Design, Erection, Testing, Commissioningfor Sop To Lis Hartara Chobu (E) Section Mahankal Uesd Kudail Under Ed Baijnath( Seop-62/2023-24).. Submission Date for this Tender is 20-02-2024. Construction Material Tenders in kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | 11KV HT line |
2 | AAAC 7/3.15 mm (50mm²) |
3 | Steel Tubular Pole (09 mtr.) |
4 | Muffs with concerete filling |
5 | Run Thro" Structures (? Formation): on Single Pole Structures (Adopt Eight (8) No. Run -through Structures per Km)- |
6 | Cross Arm: [Channel Iron (100x50x6 mm), Length (1270) mm i/c tolerance of 100mm either side x 8 structure |
7 | Angel Iron (50x50x6 mm), Length (2x750) mm x 8 structure |
8 | 11 KV Pin Insulators (Porcelain, 12 KV, 10 KN): 3 No per pole structure |
9 | Pole top Bracket |
10 | X-Arm 75x40x6 mm Length 1500 mm for Earth wire |
11 | Dead End Structures: (Adopt three (3) No. per Km) on Double Pole (Prefer along road side) |
12 | Belt Set- MS Angle Iron : 50X50X6, Length 1800mm X 2 No. |
13 | X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mmx 2 No.] |
14 | X-Arm (Horizontal)- MS Channel Iron: 100X50X6, Length 2340mm X 2 No. |
15 | Discs insulator sets on Dead End structures (comprising 1 No. Disc: (Porcelain, BS, 12 KV, 80 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides) |
16 | 11kV Pin Insulators |
17 | X-Arm 75x40x6 mm Length 2400 mm for Earth wire |
18 | HT Stay / Guy Arrangement |
19 | Stay set complete in all repect (1 No. / Single Pole, 4 No. / Double Pole Structures) |
20 | Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set) |
21 | Earthing |
22 | HT Earthing set complete |
23 | GI 8 SWG Earth Wire |
24 | Danger Plate (250x200x1.6 mm) |
25 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
26 | Barbed Wire |
27 | Aluminium Paint |
28 | GO AB Switch Unit (11kV, 400A, 25 KA ) |
29 | X-Arm: [Channel Iron (75x40x6 mm), Length: 2800mm x 4 No. for supportingGO Switch & DO Fuse Unit |
30 | Add erection charges |
31 | Add transportation charges |
32 | 11/0.4kV 250 KVA DTR |
33 | 11/0.4kV DISTRIBUTION TRANSFORMER 250KVA |
34 | S/T POLE 9MTR.W/L200KG |
35 | MUFF with concrete filling |
36 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] forincomer line |
37 | MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA"s |
38 | X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
39 | Transformer Bed, Belting & Knee Bracing |
40 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer bed |
41 | X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer] |
42 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
43 | MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos |
44 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
45 | Transformer LT Distribution Box and GO Switch fixing Assembly |
46 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
47 | MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
48 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length 460mm |
49 | GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
50 | D.O Fuse Unit |
51 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
52 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90KN)including Dead End Clamps etc. |
53 | Stay set complete |
54 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
55 | Pipe Earthing Set |
56 | LT Distribution Panel Box With MCCB(400A, 25KA,4P, 1No) & SFU(150A,4No, rewirable) |
57 | Half Clamp (M.S. Flat 50X6 mm) |
58 | Full Clamps (M.S. Flat 50X6 mm) |
59 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16mm F or more (with flat and spring washers)] |
60 | Aluminium Thimble |
61 | Aluminium Thimble |
62 | Danger Plate |
63 | Barbed Wire |
64 | Lead-Tin solder (60:40) |
65 | Solder flux |
66 | LT Cable (3.5 Core) 400 mm² |
67 | LT Cable (3.5 Core) 300 mm² |
68 | LT ABC 1*120+16+70mm2 |
69 | CT PT unit |
70 | LT switched capacitor 9-kva |
71 | Energy Meter (3-Phase, 4-Wire) DLMS compliant 600 A CT Type for 250KVA Transformer |
72 | Aluminium Paint. |
73 | ADD TPT. CHARGES AS PER COST DATA 2022-23 |
74 | ADD ERECTION CHARGES AS PER COST DATA 2022-23 |
75 | ADD ERECTION CHARGESFOR LT Cable AS PER COST DATA 2022-23 |
76 | 3F LT line |
77 | S/T Pole 8 Mtr. W/L 140 kg |
78 | RCC Muff |
79 | Shackle Insulator |
80 | D-Iron. |
81 | EggInsulator |
82 | Eye Hook Bolt |
83 | LT Stay Set |
84 | Stay Wire 7/3.15 mm ( @ 6.0 kg Per Stay Set) |
85 | LT Earthing set complete |
86 | G.IWire 8 SWG for Earthwire (1.03 km) |
87 | M.S. Nuts and Bolts (Off Sizes) |
88 | Aluminium Paint |
89 | AAAC Conductor 50 mm2 |
90 | ADD TPT. CHARGES AS PER COST DATA |
91 | ADD ERECTION CHARGES |
92 | Civil Work |
93 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
94 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
95 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) |
96 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. |
97 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
98 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm |
99 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm |
100 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
101 | Quantities are mentioned above are tentative and Actual Quantity shall be worked out after Check Survey to be carried out by the successful Tender and detailed Engineering and finalization of Tower location Chart. Payment shall be made as per Approved Bill of Material/Actual Quantities measured at site. |