Military Engineer Services-MES has published Tender For Repairs / Replacement And Day To Day / Periodical Maintenance Of Electrical Pump / Borewell / Starters And Suction Delivery Lines, Cleaning Of Oh / Ug Sump At Afs Darjipura / Jakatnaka Baroda. Submission Date for this Tender is 09-03-2024. Bore Well Tenders in baroda Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Mar-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-03-2024 |
Sl. No. | Item Description |
1 | Attending complaint /Repair/rectification of leakages to above ground water suction /delivery line of 80 mm dia DI/CI/GI tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of spunyarn, Leadjoints, rubber joints, gaskits etc, threading, drilling, tapping if required including refrashing of jointsas required at site complete all as specified and directed. Note :Spares like bend, Tee, MJ joints, collars, union sockets for /DI/CI/GI fittings required to be replaced and shall be measured and paidseparately under respective items of BOQ. |
2 | Description all as per item No 1.00 here-in-before but for GI tubing 100 mm dia complete all as specified and directed. |
3 | Description all as per item No 1.00 here-in-before but for GI tubing 150 mm dia complete all as specified and directed. |
4 | Description all as per item No 1.00 here-in-before but for CI water mains of size 200 mm dia complete all as specified and directed. |
5 | M & L for Detection of leakage in under ground pipe in main water line and attending break down of water supply pipe line and repair to CI /DI/HDPE water mains of size upto 50 mm dia at a given notice including necessary excavation in mud, in any type of soil by manual or using special T &P such as JCB etc.De-watering from the trenches by using pump sets, rectification of leakages by using spunyarn, lead joints rubber joints gasket etc fixing of CI/DI/HDPE specials such as collars bends/tail pieces etc and making joints complete all as specified and as directed. Note:-(i) Repair rectified by caulking of CI pipeare deeemed to be incuded with unit rate of job. (ii) CI specials, lead Joints, D-Joints, Clamp joints, mechanical joint etc shall be measured and paid under respective items of sch "A". |
6 | Description all as per item No 5.00 here-in-before but for GI tubing of size 80 / 100 mmbore complete all as specified and directed. |
7 | Description all as per item No 5.00 here-in-before but for GI tubing of size 150/ 200 mm bore. Notes for Sl item No 1.00 to 7.00 :- (a)The contractor will be alloted complaints at MES complaint cell on daily basis on all working days and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b)A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c)The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard. |
8 | (d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e)The quoted rated is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Air Force Station Baroda. (f)The contractor will maintain location wise record of each spare/fittings utilized as per inventory format given by AGE E/Mand the same shall be submitted to E/Mstore yard on daily basis. (g)The stationery required for the job work such as complaints registers, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items. |
9 | Supply only GI Fittings50 mm bore medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :- |
10 | Union |
11 | All equal Tee |
12 | Socket |
13 | Reducer 50 mm x 40 mm |
14 | Reducer50mm x 25 mm |
15 | Elbow |
16 | M&L for Rubber Gasket /Tyton Rubber ring as per IS :5382 suitable for 100mmDI pipes /CI pipes complete all as specified and directed |
17 | M&L for Rubber Gasket /Tyton Rubber ring as per IS :5382 suitable for 150mmDI pipes /CI pipes complete all as specified and directed |
18 | M&L for Rubber Gasket /Tyton Rubber ring as per IS :5382 suitable for 200mmDI pipes /CI pipes complete all as specified and directed |
19 | M&L for Rubber Run lead joint suitable for 80mmDI pipes /CI pipes complete all as specified and directed |
20 | M&L for Rubber Run lead joint suitable for 100mmDI pipes /CI pipes complete all as specified and directed |
21 | M&L for Rubber Run lead joint suitable for 150/200mmDI pipes /CI pipes complete all as specified and directed |
22 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying/taking out of cables, CI/GI pipe lines and getting out in sooft/loose soil complete all as specified and directed. |
23 | Returning, filling in trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cms insoil complete all as specified and directed. |
24 | Removal of excavated material and deposited where directed at a distance not more than 50M from starting point and not more than 1.5Mabove ground level complete all as specified and directed. |
25 | Taking out unserviceable CI/GI water main from trenches including fittings / fixtures like bend, Tee, Union, Elbow etc with flanged endscomplete all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under appropriate items. |
26 | 200 / 150mm bore CI pipe |
27 | 100 mm bore CI pipe |
28 | 80mm bore CI / GI pipe |
29 | 50/63 mm bore GI / MS pipe |
30 | 15mm bore GI / MS pipe |
31 | 25mm bore GI / MS pipe |
32 | Relaying of old serviceable CI/GI tubing obtained from Srl item No. 18.00 here-in-before after cleaning the pipes internally and externally with all fittings laid in trenches, floor, under road wall ceiling, floors etc for following sizes complete all as specified and directed. :- |
33 | 200 / 150 mm bore |
34 | 100 mm bore |
35 | 80 mm bore |
36 | 50 mm bore |
37 | Supply and laying Cast Iron pipes,with spigot and socket centrifugally cast, class LA, confirming to IS-1536 of 2001 in any length laid in trenches or on supports including making alteration in existing /new pipe line for insertion of new pipe if necessary of following sizes complete all as specified and directed. |
38 | 200 mm bore |
39 | 150 mm bore |
40 | 100 mm bore |
41 | 80 mm bore |
42 | Supply and laying Ductile Iron pipes,with spigot and socket centrifugally cast, class LA, confirming to IS-1536 of 2001 in any length laid in trenches or on supports including making alteration in existing /new pipe line for insertion of new pipe if necessary of following sizes complete all as specified anddirected. |
43 | 200 mm bore |
44 | 150 mm bore |
45 | 100 mm bore |
46 | Supply and laying in trenches / fixing on walls / layed on floors Unplasticiscd PVC pipe (UPVC), ISI Marked with fitting such as tees, bend elbows connecting to existing water main including taking down old pipe for following sizes complete all as specified and directed. |
47 | 80 mm bore |
48 | 100 mm bore |
49 | Supply & laying in trenches/ Walls 15mm GItubing, medium grade, ISI marked with GI fitting such as tees, bend, elbows connecting to existing water main complete all as specified and directed. |
50 | Description all as per item No. 23.00 here-in-before but 25mm bore GI tubing. |
51 | Description all as per item No. 23.00 here-in-before but 50mm bore GI tubing. |
52 | Supply and fixing in repair of heavy graded flanged MS pipe of 100mm dia 3 mtr long section with four holes flanged at both end for tightning of suitable size nut and bolts suitable for suction pipe fixing on walls / floor heavy graded, ISI marked with rubber flanged connecting to existing suction side of pump complete all as specified and directed |
53 | Description all as per item No. 24.00 above but 80mm dia pipe |
54 | M & L for construction of mild steel header not less than 350mm dia bore and minimum 3 mtr long with provision of 3 Nos incoming and 4 Nos outgoing (01 No 150mm dia and 3 Nos 100mm dia) by using MS connecting pieces both end welded flanged and other end reducers / bell mouth pieces, bends, blanking plate, tapers any type and readius and angle, tee pieces, single brach "Y" junction, double branch, both end flanged including gaswelding machine and electric welding to required length including required size of bends, tees, flanges, nuts, bolts and washers, rubber gasket etc for provision of water pressure head including lathe work finishing and painting with approved paint, all ends socket, all ends flanged of size upto 300 mm made out of MS plate suitable thick conforming to Fe-410-0 or Fe - 310-0 painting two coats of enamel paint over a coat of red oxide primer including dismantling of old valve pit complete all as specified and directed. Note: Rate of welding / end cape / dismantling of existing header etc any type of arrangement for fixing is included in item rate, no extra payment should be made to contractor |
55 | Detection of leakage in main water line by necessary excavation in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to CI pipe of 200mm bore by burning & including lead, spunyarn etc as occuring at Site including cutting, threading for addition & alternation and for insertion of fittings all as required. (for Main Line from Jakatnaka) complete all as specified and directed Note:- (i) Rate quoted shall be deemed to be inclusive of necessary excavation in hard/dense soil to a depth exc 1.50m and n.exc 3.5m including necessary returning filling, removal of soil, draining of water if any and making good the existing surface all as directed by the Engineer-in-Charge. (for Main Line from Jakatnaka to Darjipura alongwith highway) |
56 | Supply and fix accessories, CI / DI specials confirming to IS 1578 of 1970(any type radius and angle) such as bends, tapers, straight, increasing / decreasing or double socket / flanged end collars, connecting pieces etc, as required at site and for Upto 200mm bore size completeall as specified and directed. Note:- Lead joints and jointing material shall be measured and paid in above item. |
57 | Supply and fixing of mechanical Joint (MJ) fittings of various sizes and various depth of any type radius and angle such as tapers, straight, increasing / decreasing or double socket / flanged, connecting pieces etc, as required at site and for the folowing sizes complete all as specified and directed |
58 | 200/250 mm bore size |
59 | 150 mm bore size |
60 | 100 mm bore size |
61 | 80 mm bore size |
62 | Dismantling / Taking down unserviceable Gun metal globe/gate valve and supply and fix new Gun metal globe / gate valve, screwed down high pressure with iron wheel head, screwedboth ends for GI/PPR pipe including all fittings / fixtures like nipple, union etc complete for following sizesall as specified completeall as specified and directed. |
63 | 25 mm bore size |
64 | 15 mm bore size |
65 | Supply, fixing and testing of SS Spindle CI sluice valvepressure/class/rating PN 1.6, long body, confirming to IS- 14846 : 2000 complete all as specified and as directed including dismantling of existing sluice valve of following sizes complete all as specified and directed. |
66 | 200 mm bore sluice valve |
67 | 150 mm bore sluice valve |
68 | 100 mm bore sluice valve |
69 | 80 mm bore sluice valve |
70 | Construction of brick masonry valve pit chamber of inner dimension 900x900x1050mm suitable for valves up to 200 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering in CM 1:4, 15 mm thick mixed with water proofing compound, coping in PCC 1:2:4 type B-1, including necessary earth work, form work and provision of MS sheet cover of thickness not less than 2.80 mm on 50 x 50 x 6.0 mm Angle iron frame with locking arrangement, including painting over MS surfaces with two coats of synthetic enamel paint over one coat of red oxide primer etc, complete all as specified and directed |
71 | Description all as per item No 31.00 here-in-before but valve pit chamber of inner dimension 750mmx 750mm x1050mm complete all as specified and directed. |
72 | M&L for painting the surface of each Pump- Motor set of any capacity with sluice valve completewith one coat of primer,writing machine number as directed complete all as specified and directed. |
73 | M&L for painting of CI/GI pipes of 200mm bore at pump houses such as suction and delivery main with two coats of synthetic enamel paint as per MES colour code including preparation of surfaces by scrubbing down old existing paint complete all as specified and directed. |
74 | M &L for Cleaning and de-silting of RCC under ground sump with Chemical such as bleaching powder of following capacity after de-watering and cleaning scrapping with steel brushes/hessin cloths of the sump walls from inside and including floor of the sump complete and repair to vent pipes including providing wire mesh and clamps complete, providing two coat of white wash internally and writing Cleaning date and next due date with black enamel paint on white background complete all as specified and directed Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the required level without any extra cost. Necessary tools and safety measures to be arranged by contractor. |
75 | 15000 Gallon |
76 | 20000 Gallon |
77 | 50000 Gallon |
78 | 100000 Gallon |
79 | M & L for cleaningde-siltingof Overhead tank of following capacity by scratching and cleaning inside walls,pillars and floors with bleaching powder and clean water including taking out dirt, mud from storage tank including stag at site and removal from out side MD land and repair to vent pipes including providing wire mesh to cover all air gap holes and clamps complete providing two coat of white wash internally,and writing Cleaning date and next due date with black enamel paint on white bacground complete all as specifiedand directed Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the mark without any extra cost. Necessary tools and safety measures to be arranged by contractor. |
80 | 35000 Gallon |
81 | 50000 Gallon |
82 | 75000 Gallon |
83 | 20000 Gallon |
84 | Supply, install and testing of KASHYAP anti scale system, model K-25 operated on 220V AC supply as input and 24V DC supply, suitable for 3" dia pipe,up to 25 M3/Hrs flow , impulse band 3M x 4,with descealing strip generate a controlled electrophoresis process,which produce metalcarbonate layer inside of pipeinstall at various places complete all as specified and directed |
85 | Supply and fix Gland packing 6mm thick for sluice valve and pumps complete all as specified and directed. |
86 | M & L for dismantling of defective sluice valve for repairssuch as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc complete all as specified and directed of following sizes:- |
87 | 80 mm bore. |
88 | 100 mm bore. |
89 | 150mm bore. |
90 | 200mm bore. |
91 | M & L for mild steel framed work as in doors or gates of angle (40mmx40mmx5mm) or other section with gusset plates, rails,braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging also fastening and fixing complete with locking arrangement complete all as specified and directed.(Under ground Sump) |
92 | M & L for 2mm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc as required complete all as specified and directed. |
93 | M & L for Drilling and tapping cast iron/GI water mains (in position) for branch connections of the internal dia of 20mm bore size including ferrul complete all as specified and directed. |
94 | Labour only for Disconnecting and lifting of the existing non functional submersible pump set from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity upto 20/15 HPandin any position, along with existing column pipe 50mm dia and existing submersible cable of any size from the bore well (approximately 450 feet depth of pump set from GL) and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed. NOTE: - Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc. shall be arranged by the contractor at his own cost. |
95 | (ii). Number of column pipe may vary from 30 to 50, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints along with flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately. |
96 | Labour only for Lowering down of the submersible pump set of any description and any capacity and in any position, in bore well along with column pipe 50 mm dia and submersiblecable of any size (approximately 450 feet depth of pump set from GL) complete all as specified and directedincluding making necessary electric connections & testing the pump set after lowering complete all as specified and directed. |
97 | Supply only the following items/ spare parts suitable for ACsubmersible pump set/Moter up to 5 HP capacity dismantled under Schedule ‘A’ item here in beforecomplete all as specified and directed. |
98 | Cast iron stage bowl |
99 | Gun metal neck ring make NITCO’ or equivalent |
100 | Anti magnetic stainless steel pump shaft with key made : DD/’KSB or equivalent |
101 | Impeller gunmetal make: NITCO/ KSB or equivalent |
102 | Stainless steel sleeve (inlet) make : DD/KSB or equivalent |
103 | Stainless steel sleeve (outlet) make : DD or equivalent |
104 | Running bush outlet of gun metal |
105 | Stage bowl cover |
106 | Bolt stud with nut and washers |
107 | Running bush inletofgun metal |
108 | Strainer stainless steel |
109 | Shaft nut with washer |
110 | Supply only the following items/ spare parts suitable forsubmersible motor ofAC 5 HP capacity complete all as specified and directed. |
111 | Connector for motor |
112 | Steel bolt set |
113 | Key for thrust plate |
114 | Thrust bearing[set of 02] |
115 | Cable pressure washer |
116 | Thrust plate |
117 | Laour only for dismantling/taking downof complete Engine driven pump assembly after disconnecting existing water supply pipe line andfollowing checks shall be done for Engine driven pump 10 BHP . (a) Checking of lubricating oil condition(b)Checking engine for oil,water leakage and correcting the same (c) Checking of all the nut bolts of engine and pump (d) Checking of all pipes and adjustproperly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance(g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of pump motor coupling(i) Checking of cooling system and fuel systemprime moover connectionfrom Pump and transporting to work shop for opening the engine and replacement of unserviceable worn out partsoverhaualing,reassmbling and alignment withreplacement offollowing unserviceable parts and refixing the same back to pump houseform including testing completeall as specified and as directed. NOTE (1) Cost of Spares required will be paid and measured separately (2)Servicing/routine check up carried out through authorised service centre of manufacturer |
118 | Supply and fix in repair following parts for existing Engine driven pump set 10 BHP |
119 | Engine oil 24W40 type for varioius |
120 | Air cleaner Assy complete |
121 | Air cleaner refill of existing type |
122 | Oil filter element |
123 | Fuel filter element |
124 | Suction / delivery green pipe of 4" dia flexible type |
125 | Fuel pipe with benjo bolt at both side of suitable size |
126 | Starting handle |
127 | MS Coupling for engine and pump |
128 | M & L for calibration of injector unit including supply and fixing in replacement O-Ring, Pin roll, barrel, Pin spring, washer and testing for 10 BHP Engine dirven pump complete all as specified and directed |
129 | Dismentling& taking out existing U/S pumping unit of pumpmotor set installed at MAP pump house Darjipura and S & F of new pumping unit (centrifugal Pump) of 100x100 mm size suction and delivery with 2900 RPM and discharge of 100 mtr3 /Hrs on35 Mtr headsuitable for coupled with 415 V 3 phase of 25 HP capacity existing motor including stainless steel impeller, mechanical seal,MS coupler with rubber packing & stainless steel shaft complete assembled / alligned with existing motor on common iron frame recommended by OEM and grouted on foundationincluding testing and commissioning complete all as specified and directed. Note- 1.PCC /RCC foundation for grouting of Pump is dim included in quoted rate. Required length of MS pipe and fabrication of suction and delivery pipe also included in quoted rate. 2. It is suggusted that contractor has to be visit the site (MAP Pump house Darjipura) before qoute the rate. If item will not executed by contractor thenPenalty of Rs 50000/-will be recovered. 3. Old U/S pump unit will be deposited in MES store yard. |
130 | Rewinding the submersible motor 5 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etc complete all as specified and directed. |
131 | S&F in repair of aviation obstruction light suitable for OH tank up to 50 mtr Height ,red colour,IP 67,with junction box ,aluminium LM6 casting ,heat resistant, power 75VA borosillicate glasses and alternate circuit technologyLED light fitting suitable for over head tankwith and including 1.5 sqmm 2 core cable 20 meter for connetion and nuts, bolts, clamps complete all as specified and directed |
132 | Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 3 pole, 415 Volt AC supply, 250 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directed. |
133 | S&F in repair of contactor 4 pole with AC coil 415 volt 50 Hz,25 Amp for motor starter complete all as specified and directed. |
134 | Material & labour for boring of holes under road for insertion of pipe of up to 200 mm bore, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine complete all as specified and directed. |
135 | M & L for water testing in Biological& Chemical test for various location at collection of the sample from the various site (like pump house, RO plant & Bore well, pump house, STP, swimming pool will be measured as one job) and testing in each quarter through authorised lab complete all as specified and directed . |
136 | M & L for Notice board for installation glass top of size 5" x 4" x 2", front openable alumine body, blue / greem blezer cloth fixed inside of the board, board fixed on wall as per direction fixing arrangement complete all as specified and directed |
137 | Supply and fix in repair of submersible pump motor DOL starter of 5 HP as suitable at site complete all as specified and directed |
138 | M & L for Taking out and rewinding of openwell submersible motor 1 HP with PVC insulated submersible rewinding wire of suitable gauge/size as existing including rotor balancing, testing and connection of submersible cable and cable gland including taking down old winding wire complete all as specified and directed. |
139 | M & L for Taking out and rewinding of pressure booster motor 1 HPrewinding wire of suitable gauge/size as existing including rotor balancing, testing and connection of connection cable and other fittings on roof top including taking down old winding wire complete all as specified and directed. |
140 | S&F in repair sensor system of pressure booster pump of 1 HP including testing on ground complete all as specified and directed. |
141 | Labour only dismantling / taking down of complete centrifugal pump assembly after disconnecting existing water supply pipe line and electric connection from motor and transporting to work shp opening the pump and replacement of unserviceable worn out parts refixing, overhaualing, reassembling and alignment with replacement of following unserviceable parts and refixing the same back to pump house platfrom including testing complete all as specified and directed Note: Spares of items required shall be paid separately under respective item of BOQ. |
142 | 7.5 / 12.5 HP pump with motor |
143 | 25 HP pump with motor |
144 | 40 HP pump with motor |
145 | 50 HP pump with motor |
146 | 40 HP Vaccum pump |
147 | M & L for rewinding of monoblock/ Centrifugal pump (Motor), 3 phase, 415 voltwith supper emamelled copper rewinding wire of suitable size/gauge as existing and providing insulation varnishing, heating, testingincluding taking out the existing winding wire complete all as required for completion of JOB for following capacity pumps complete all as specified and directed |
148 | 7.5 / 12.5 HP pump with motor |
149 | 25 HP pump with motor |
150 | 40 HP pump with motor |
151 | 50 HP pump with motor |
152 | 40 HP Vaccume pump / motor |
153 | Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 50/40 HP having discharge 400 LPM at 990 mtr head complete all as specified and directed |
154 | Motor bearing . Make : SKF/NBC/TATA/FAG/ UBC. |
155 | Motor cooling fan |
156 | Pump motor MS coupling |
157 | L-190 spider. |
158 | Cover bolts & washers |
159 | Pump bearing No. 6307 of Make : SKF/UBC/TATA/FAG/ NBC |
160 | CI impellar suitable for centrifugal pump set. |
161 | CI Gland packing chaplla |
162 | SS Sleeve (Gland Sleeve) |
163 | Pump shaft with studs and nuts for pump body. |
164 | Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 40 HP having discharge 400 LPM at 990 mtr head. |
165 | Motor bearing . Make : SKF/NBC/TATA/FAG/ UBC. |
166 | Motor cooling fan |
167 | Pump motor MS coupling |
168 | L-190 spider. |
169 | Cover bolts & washers |
170 | Pump bearing No. 6307 of Make : SKF/UBC/TATA/FAG/ NBC |
171 | CI impellar suitable for centrifugal pump set. |
172 | CI Gland packing chaplla |
173 | SS Sleeve (Gland Sleeve) |
174 | Pump shaft with studs and nuts for pump body. |
175 | Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 25 HP complete all as specified and directed |
176 | Motor cooling fan |
177 | Pump motor MS coupling |
178 | L-190 spider. |
179 | Cover bolts & washers |
180 | Pump bearing Make : SKF/UBC/TATA/FAG/ NBC |
181 | Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC |
182 | CI impellar suitable for existingpump set. |
183 | CI Gland packing chaplla |
184 | SS Sleeve (Gland Sleeve) |
185 | Pump shaft with studs and nuts for pump body. |
186 | Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 12.5/7.5 HP complete all as specified and directed |
187 | Motor cooling fan |
188 | Pump motor MS coupling |
189 | L-190 spider. |
190 | Cover bolts & washers |
191 | Pump bearing Make : SKF/UBC/TATA/FAG/ NBC |
192 | Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC |
193 | CI impellar DB 80/20 for existing 50/40 HP centrifugal pump set. |
194 | CI Gland packing chaplla |
195 | SS Sleeve (Gland Sleeve) |
196 | Pump shaft with studs and nuts for pump body. |
197 | Starter relay of Make : Jyoti, Range 36-60 |
198 | Magnet coil of MakeJyoti. |
199 | Starter copper contact set |
200 | Starter oil. |
201 | Starter base plate |
202 | Supply and fix in repair fully automatic star delta starter of following capacity all as specified and directed. |
203 | For 50/40 HP motor |
204 | For 25 HP motor |
205 | For 12/7.5 HP motor |
206 | Supply & provide Aquafit (Calcium hypo chlorite)65% - 70% chlorine content (Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chlorite packed in 45 Kg drum complete all as specified and directed |
207 | Supply of water through tanker/bouser for domestic use including transportation from source to U/G sump Darjipura AFS Baroda complete all as specified and directed.The water should have the following main factors :- (a)Water should be clear and from all suspended matters both Hyganic & inorganic matter. (b) Water should be free from taste and odour. (c) Water should be colour less and no vegetable stain should be present. (d) Water should be soft that it should not contain dissolved impurities like calcium or magnesium bicarbonate and Sulphates. (e) Water should be soft and should be free from all pathogenic organism causing diseases. (f) Copy of gate entry at guard room with vehicle No date and time shall be submitted duly defaced by Engr in charge before claiming payment. Note : Water analysis duly tested by authorised lab will be rendered by supplier before supplying the water. |
208 | M & L for cleaning of static water tank (SWT) 100000 Ltrs with all T&P and man power required to pump out the existing water and removing the sludge and greet from 6f ft deep water collector and throwing it out side 50Mtr away from site complete all as specified and directed. |
209 | Repairing and servicing of Digital water level indicator suitable for Over Head water storage tanks upto 30 meter staging including of dome height complete with replacement of following necessary parts are (measured and paid separately with ISI marked including taking down products) complete all as specified and directed:- Note:- 1.Any PCC work for fixing of scale is also inclusive in this item. 2.No other payment will be issue to contractor for working in Height. 3.Contractor must be apply all safety measures for installing the same items as work on heights. 4.As work will be done in height so contractor is responsible for insurance of his employees. |
210 | Digital display unit of existing make and model suitable to operation on AC 220 V 50 Hz |
211 | Sensor unit on O/H tank |
212 | Multi core sensor cable of copper solid conductor |
213 | Supply and fixing of brass foot valve of following sizes incl lifting of UNSV foot valve from UG sump from any depth by removing of suction pipes of pumps complete all as specified and directed. |
214 | For 100mm dia pipe |
215 | For 80 mm Dia pipe |
216 | Supply and fixing of On-line chloronator booster dozing pump capacity 1 HP suitable exisiting chloronator system complete all as specified and directed |
217 | M&Lfor fabricationof motor pumpbase and suppportingleg of various pipes etc using MS flate 25x5mmiron strip/channel/angle Ironincluding necessary cutting , welding, bending etc complete all as specified and directed. |