Tender For Additional/Alternator And Repair To Offer Md Accommodation Buildings At Palampur Military Station, palampur-Himachal Pradesh

Military Engineer Services-MES has published Tender For Additional/Alternator And Repair To Offer Md Accommodation Buildings At Palampur Military Station. Submission Date for this Tender is 18-03-2024. Mobile Generator Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42191528
Corrigendum : Tender For Additional/Alternator And Repair To Offer Md Accommodation Buildings At Palampur Military Station
Open Tender
Indian
Himachal Pradesh
palampur
18-03-2024

Tender Details

Tender For Additional/Alternator And Repair To Offer Md Accommodation Buildings At Palampur Military Station

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Feb-2024 REVISION OF BOQ AND CERTAIN PAGES BOQ 11-03-2024
2 11-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-03-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 134500.0 /-
Tender Value
INR 73 Lakhs /-

BOQ Items

NAME OF WORK:- ADDN/ALTN AND REPAIR TO OFFR MD ACCN BULIDINGS AT PALAMPUR MILITARY STATION
Sl. No. Item Description
1Demolition of cement concrete (unreinforced) in ground floor and pavingn.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
2Demolition of reinforced cementconcrete (reinforcement cut as required to facilitate demolition)of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
3Demolition of existing cement concrete padding of water proofing treatment from roof including taking down bituminous polythine sheets plasters etc over all thickness n.exc. 200 mm cleaning of concrete surface by wire brush scrubbing down with water and removing the dust debris etc to a distance exceeding 1.50 Km but n.exc. 5.00 Kmfrom the work site concrete all as directed.
4Demolition of brick workor stonework built in cement mortar including allquoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
5Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints,hacking for key , scrubbing down with water etc complete all as specified and directed
6Taking downsteel water tubing 15 mm bore including all fitting and connections complete all as specified and directed.
7Taking downsteel water tubing 20 mm bore including all fitting and connections complete all as specified and directed.
8Taking downsteel water tubing 25 mm bore including all fitting and connections complete all as specified and directed.
9Taking downand removing chowkats with shutters (withouttaking off shutters from chowkat)not exceeding 1.50 Sqmeach complete all as specified and directed.
10Taking down and removing chowkats with shutters (withouttaking off shutters from chowkat)exc 1.50 Sqmbut not exc 4.00 Sqm each complete all as specified and directed. .
11Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each and removing from site, complete all as specified and directed. .
12Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each and refixing after making necessary repair , complete all as specified and directed. .
13Dismantling plain or corrugatedsteel sheetsany gaugethickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
14Dismantlingtimber in scantling 40 sqcm and over in section framed work complete all as specified and directed.
15Dismantlingtimber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section un-framed work complete all as specified and directed.
16Dismantling floor, hearth or wall tiling including cement mortar bedding (But not backing), removing and rubbish of the premisses, complete all as specified.
17Dismantling of cast iron or reinforced concrete drain pipes 100mm bore, jointed in cement mortar and taking out of trenches, if required, complete all as specified.
18Dismantling of cast iron or reinforced concrete drain pipes 75mm bore, jointed in cement mortar and taking out of trenches, if required, complete all as specified.
19Taking down roof trusses, coupled rafters or trussed beams above8m and upto 12m, complete all as specified.
20Demolition and breaking up 150mm bore drain pipe(Salt glazed ware, PVC,AC or Reinforced concrete) set in cement mortar including demolition of PCC under and haunching complete all as specified and directed.
21Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed.
22Hacking out old broken glass (any thickness, size, quality or description) from wooden or steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
23Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
24Taking down steel Rolling shutters or frames and removing from siten exc 10 sqm as specified allas directed by Engineer-In Charge.
25Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type ofsoil, complete all as specified and directed.
26Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed.
27Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
28Precast reinforced cement concrete as in landing, cover slabs (for manhole etc) and similar articles withprecast cement concrete Type B-1, 1:2:4 (20mm graded crushed stone aggregate) and setting in cement mortar 1:4 complete all as directed.
29PCC 1:4:8 (nominal mix) type D-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed.
30Plain cement concrete 1:2:4 ( nominal mix )type B-1 (using 20 mm graded crushed stone aggregate) as insurface channel drains all as specified and as directed.
31Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified and as directed.
32PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
33Brick work with old size fly ash bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:4 all as specified & directed.
34Walling of random rubble stone masonry, uncoarsed, well bonded, bedded and soilidly hearted,built in CM 1:6, complete all as specified and directed.
35Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 105 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkatscomplete all as specified.
36Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 165 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkatscomplete all as specified.
37Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete as shown on page No176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
3835mm thick2nd class hardwood Plain framed, panelledshutter (Factory Made) (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated and fitted to chowkats complete all as specified and directed.
3935 mm thick 2nd class hardwood glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members ofdoor shutters as specified in SSR- 2009Part-I Section 8.24(a) complete all as specified and directed.
40Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails.M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Pane of 4 mm thick sheet glass to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable 5mm thick x15mm wide PVC sheet beading used inside stiles and rails anddecorative PVC beading of 10mm x 10mm (900 ), and joined together with solvent cement, suppling & fixing in the frame at site, complete as shown on page No176 to 183 of MES SSR 2020 Part-II compete all as specified and directed.
41Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS tube factory made with double side shutters wire gauged shutters & glass glazed shutter(wire and glass panes shall be measured and paid separately) with side hung shutters with steel handles and steel peg stay doytailed at welded incl 2 Nos tower bolts 150 mm long for each leaf and 8 mm square bar grills at spacing as shown on drg welded to FI frame work,incl other fittings,hinges,handles tarred hold fast PCC blocks etc. all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 ,complete all as specified.
42Steel ventilator with top hung shutter including hinges, steel peg stay, complete, complete all as specified and directed.
43Extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed.
44Aluminium anodizedbarrel tower bolt of extruded section of size 150 mm and fixed complete all as specified and directed.
45Mild steel butt hinges of size 100mm medium weight cold rolledcomplete all as specified and directed.
46300mm longaluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
4775mm size, Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
48Stainless steel peg set of five pegs, fixed/wel ded/soldered on stainless steel base plate of size 300x30x2.5 mm and fixed with stainless steel screws, rowel plugs as per the sample approved by the Engineer-in-charge complete all as specified and directed.
49Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete, overall length of cover plate 140mm, complete all as specified and directed.
50Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
51Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples,fixed in repair, complete all as specified and directed.
52Sheet glass, 3 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
53Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
54Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking endsand binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
55Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
56Mild steel work as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
57RolledMild Steel Work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410- W(Gde-E-250) quality- A, complete all as specified and as directed. , complete all as specified and as directed.
58Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 , complete all as specified and as directed.
59Steel rolling shutters "(thickness of lath 1mm), with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
603mm thick, figured glasspin head type and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
61Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
62Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
636mm thick E-board (Classic) false ceiling of size 610mm x 610mm fixed with and includingaluminium snap grid frame work of same size as aluminium tee of size 25x25x1.50mm as main runner, 25x25x1.25mm thick aluminium tee as cross runner and aluminium angle of size 25x25x1.25 mm at the perimeter, including GI adjustable suspender of required length,complete all as specified.
6418/19mm thick, Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in cup board shutter/shelves/pelmet box, fixed in repair , complate all as specified.
65Auto closing hinges 35 mm of 0 degree crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters fixed in repair complete all as specified and directed.
66Ball bearing runners 45 mm Telescopic (KTS-20) full extension load capacity 50 kgs fixed in repair complete all as specified and directed.
67Stainless steel handles 100 mm size for kitchen cabinet shutters fixed in repair complete all as specified and directed.
68Chromium plated stainless steel wire basket ( storage basket) pull out type for large utensils size 480 x 500 x 150 mm of Grade 304 with necessary fixing clips etc fixed in repaircomplete all as specified and directed.
69Chromium plated stainless steel wire basket ( cup and saucer basket) pull out type for large utensils size 380 x 500 x 100 mm of Grade 304 with necessary fixing clips etc fixed in repaircomplete all as specified and directed.
70Chromium plated stainless steel wire basket ( Plate basket) pull out type for large utensils size 380 x 500 x 100 mm of Grade 304 with necessary fixing clips etc fixed in repaircomplete all as specified and directed.
71Chromium plated stainless steel wire basket ( Cutlery basket) pull out type for large utensils size 380 x 500 x 100 mm of Grade 304 with necessary fixing clips etc fixed in repaircomplete all as specified and directed.
72Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mmthick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
73Vitrified ceramic tiles (light shade) 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
74Vitrified ceramic tiles (light shade) 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm as directed by EIC as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
75Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE
76Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
77Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE
78Machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4, cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified.
79Machine cut kota stone slab flooring 20-25 mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as inin skirting, dados, risers to steps etc, laid over and including 10mm thick rendering in cement mortar 1:4 , cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
80Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with ad mixture of pigment to match the shade of granite stone including grinding and polishing complete. complete all as specified and directed.
81Glazed ceramic colouredtilesof size350x 250x 7 mm/ 450X 350X 7mmthick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
82Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
83Rendering cement plaster 10mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, as in ceiling , surface finished even and smooth without using extra cement, all as specified.
84Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
85Rendering cement plaster 15mm thick in cement mortar 1:3 as in sunken floor including WPC includingng taking out exisiting filling anf repairing the sunken floor concrete and making the line in true shape , surface finished even and smooth without using extra cement, all as specified.
86Chipping of unsound/weak concrete material from slabs (, beams, columns, (25mm average thickness for slab/chajja/ceiling) etc, with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-in-Charge including tampering all edges, making square shoulders of cavities etc incl scoffolding complete and disposal of debris upto 50m and all as directed..
87Chipping of unsound/weak concrete material from slabs (, beams, columns, (50mm average thickness for beams/columns) etc, with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-in-Charge including tampering all edges, making square shoulders of cavities etc incl scoffolding complete and disposal of debris upto 50m and all as directed..
8815mm thick cement plaster in cement mortar 1:3 on concrete surface of roof or terracing surface, finished even and smooth without using extra cement,mixed with water proofing compound complete all as specified and directed by Engr-in-Charge. (NOTE: WPC to be measured and paid separately).
89Supplying and applying High performance two component brushable elastomeric polyurea waterproofing coating cold applied brush applied ultraseal BA or approved equivalent liquid membrane with white in color with an elongation of 500% and tensile strength of 5 N/mm2@ DFT 1mm as per ASTM D 2370,73 % Solid content, shore A Hardness of Min 70. The system includes final base preparation epoxy primer application@200-250 grms/sqmt depending upon the surface porosity and applying Home Shield Ultaseal BA or Approved equivalent in two cots at 1.5 kg per Sqm providing 1.2 mm DFT etc,complete as per Manufacturer specificationcomplete all as specified and directed by Engr-in-Charge .
90Mixing and applying bonding coat,acrylic polymer modified cementitious bond coat @ 2.2 kg cement per sqm of surface area with specified proportion of polymer admixtute( rate shall include cost of cement), on prepared surface of parent materials as per specification and as direc Engr-in-Charge.
91Providing and mixing polymer modified cement mortar in layer (25mm average thickness for slab/chajja), each layer not exceeding 10 mm thick, including trowelling with wooden tools etc, complete as per specification and direction of Engr-in- Charge. Note :For payment purposes, pre-measurement of thickness shall be done just after the surface preparation is completed. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sound/tapping with a blunt metal instrument.
92Providing and mixing polymer modified cement mortar in layer (50mm average thickness fordeams/columns), each layer not exceeding 10 mm thick, including trowelling with wooden tools etc, complete as per specification and direction of Engr-in- Charge. Note :For payment purposes, pre-measurement of thickness shall be done just after the surface preparation is completed. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sound/tapping with a blunt metal instrument.
93Preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girthand applying two coats of synthetic enamel paintover a coat of pinkprimer complete all as specified and directed.
94Preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise describedand applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed.
95Preparation of old wooden surfaces of any description, not otherwise described, over 10cm in width or girthand applying one coat of synthetic enamel paint, complete all as specified and directed.
96Preparation of old steel surfaces of any description, not otherwise described, over 10cm in width or girthand applying one coat of synthetic enamel paint, complete all as specified and directed.
97Preparation ofoldplastered surfaces or un plastered, previously undecorated ceiling surfaces and applyingone coat of white wash, complete all as specified and directed.
98Preparation ofnewplastered surfaces or un plastered, previously undecorated ceiling surfaces and applyingthree coats of white wash, complete all as specified and directed.
99Preparation ofnewplastered surfaces or un plastered, previously undecorated wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm, complete all as specified and directed.
100Preperation ofold wall surface by removing existing treatment by scrapping, brushing etc including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and filling holes, dents, cracks with mixture of white cement and mortar for applying one coats of acrylic, antifungal emulsion exterior weather proof paint on existing external surfaces, complete all as specifiedand directed by Engineer in Charge.
101Preparation ofnewplastered surfaces or un plastered, previously undecorated wall surfaces and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. Two or more coats on new work, complete all as specified and directed.
102Preparation ofoldplastered surfaces or un plastered, previously undecorated wall surfaces and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. one coat on old work, complete all as specified and directed.
103Wash hand basins with pedestal, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot" or ‘Cold" with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, fixed in repair,completeall as specified.
104Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore iron pipe or for unionsfixed in repair complete all as specified.
105Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore, fixed in repair, complete all as specified and directed.
106Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed 15 mm bore, fixed in repair, complete all as specified and directed.
10715mm bore, Brass CP centre hole basin mixerfor mixing hot & cold water , opal prime single lever High neck , fixed in repair, complete all as specified and directed.
10815mm bore, Brass CP sink mixerfor mixing hot & cold water , with regular swinging spout (wall mounted type) with connecting legs and wall flanges, fixed in repair, complete all as specified and directed.
109Brass chromium plated shower rose 125mm sizewith or without swivel joints, including fixing to steel pipe or union.fixed in repair complete all as specified.
110Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
111Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 15cm dia, complete all as specified and directed.
112PVC Bathroom cabinet of size 50cmx41cm with hinged door and locking arrangementwith built in shelvs and looking mirror, fixed in cabinet door, fixed to wall as per manufactuerer"s instructions, fixed in reapir, complete all as specified.
113S&F in repairs, Hand Shower (Health Faucet) with 1.2 Meter Long Easy Flex Tube in Chrome Finish with Wall Hook and 25mm bore chromium plated stop valve completeall as specified.
114Continuous (piano) hinges,mild steel, bright finish or electrogalvanised, width of flap 30mm (when opened), complete all as specified.
115Soap dish, SS, approximate size 160x160x90mm, any type, fixed to plugs with chromium plated brass screws, fixed in repair complete all as specified.
116S&F in repairs, Chromium plated Toilet Paper Holder with Flap Recessed Type, fixed to walls with chromium plated brass screws, completeall as specified.
117PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, fixed in repair, all as specified. Make: Cat Part No. 2602 ofCera or equivalent in makes mentioned in Appx .
118Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc, fixed in repair all as specified. Make: Cat Part No. 2071 of "Cera" or equivalent makes mentioned in Appx.
119Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover andchromium plated jet including PVC connection, fixedcomplete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs all as specified. Make: Cat Part No. 2008 for EWC, 2308 for seat cover, 2201/B for internal fittings of"Cera" or equivalent makes mentioned in PS.
120Sink with drainage board made of stainless steel, l mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
121Stainless Steel plate rack of overall size750mm x 600mm x 250 mm made of stainless steel having thickness1mm, fixed with screws in poistion complete all as specified and directed.
122G I tubingmedium gradeof 15 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed.
123All as per item 122 above but fixing only
124G I tubingmedium gradeof 20 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed.
125All as per item 124 above but fixing only
126G I tubingmedium gradeof 25 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed.
127100mm bore, Cast iron, soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with lead joints, fixed to walls , complete all as specified and directed.
12875mm bore, Cast iron, soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with lead joints, fixed to walls , complete all as specified and directed.
129100mm bore, Bends (any radius), diminishing pieces or tapers (larger bore measured) , fixed with oval access door, complete all as specified and directed.
13075mm bore, Bends (any radius), diminishing pieces or tapers (larger bore measured) , fixed with oval access door, complete all as specified and directed.
131100mm bore, Branch pieces, single (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches , fixed with oval access door, complete all as specified and directed.
13275mm bore, Branch pieces, single (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches , fixed with oval access door, complete all as specified and directed.
133Stack clamps made out of 50mmx5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100mm bore of pipe, complete all as specified and directed.
134Stack clamps made out of 50mmx5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 75mm bore of pipe, complete all as specified and directed.
13575mm bore,Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed.
136Cast iron cowl for 100mm bore of pipe complete all as specified and directed.
137Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supplyline including dismantlinf old tank complete all as specified.
138Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supplyline including dismantlinf old tank complete all as specified.
139PVC coated mild steel conduit pipe 25 mm bore (Drapery rod) with a pair of PVC coated MS clamps to hold drapary rod and decorative attachment at one or both ends of drapary rod,fixed to opening of door/windows, (fixed in repair), contained with a pair of clamps and a pair of side ornamental attachments)complete all as specified and directed.
140Salt glazed stoneware drain pipe150 mm diagrade"A" laid in trenches and jointedwith cement joints complete all as specified and directed
141Concrete bed to drain pipeof 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) complete all as specified and directed.Note :- Thickness of bed and width of bed shall be provided all as per preamble a (i) & a (ii) on Srl page no 391 of SSR Part-II Rates (2020).
142Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
143Taking down main switches, distribution board, steel enclosure with MCB"s any way and rating including wooden board or from steel board and making good distubed surfaces complete all as specified and directed.
144Taking down the sub main wiring of any size from the wall/roof/ceiling and removing from the site and making good disturbed surface complete all as specified and directed.
145Taking out/down un-serviceable XLPE Cable of any type and any size from pole to building complete all as specified and directed.
146M&L for point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Med Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Pressed steel powder coated Modular GI sunken flush boxese of any way i.e. 1 to 8 way as per site requirement suitable for modular switch/socket) for mounting switches, sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a)Wiring shall be done by using proper colour coding (b)Earth wire shall be of green colour (c)On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed. Note: Modular white cover plate with frame shall be measured and paid separately.
147All as per serial item No "146" above, but for one 3 pin 5 Ampssocket outlet, on same board all as specified and directed.
148All as per serial item No "146" above, but for one 3 pin 5 Ampssocket outlet, independent all as specified and directed.
149All as per serial item No. "146" above but for 3 pin 15 Amps socket out letindependentwith 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
150All as per serial item No. "146" above for two way switchese, all as specified.
151Modular switch 2 way 6A, 1 module complete all as specified and directed.
152Modular bell push 1 way 6A, 1 module complete all as specified and directed.
153Modular switch 1 way 6A, 1 module complete all as specified and directed.
154Modular socket, 6A-2/3 pin combined 2 module complete all as specified and directed.
155Modular socket, 6A and 16A, 2/3 pin combined 2 module complete all as specified and directed.
156Modular switch 1 way 16A, 1 module complete all as specified and directed.
157S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amp & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed.
158Bell, AC, 230 volts, single pole all as specified.
159Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
160Lamp holder, PVC/Polycarbonate type with back plate suitable for angular/ batten fittingscomplete all as specified & directed.
161Sub main wiring with two single core PVC insulated cable1100 volts grade with copper strandedRLS conductor of size 16 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire ofsize 16 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor andone RM of earth wire of 4 Sqmm,shall be measured as one RM).
162MCB SPN 32-40 Amp, 240 Volts, 10 KA all as specified.
163MCB SPN 63 Amp, 240 Volts, 10 KA all as specified.
164MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.
165Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
166Sheet metal enclousers, VTPN Distribution board 4 way 415 V, double door with 100A MCCB as incomer complete with copper bus bar and neutral link earthing fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Note:- Distribution board and MCB"s should be same make.
167Sheet metal enclousers, VTPN Distribution board 4 way 415 V, double door with 125A MCCB as incomer complete with copper bus bar and neutral link earthing fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Note:- Distribution board and MCB"s should be same make.
168Wall mounted LED integrating batten fitting T5, 10 Watt LED, 2 feet, PVC extruded with 10 watt LED tube rod with all acessoreis prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make: Havell"s Cat Part No. LUMILINEBS10WLED865SPCWH of"Havells" or equivalent in makes mentioned in Appendix
169Supply & fixing surface /wall mounted light fittingpre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make:-Cat Part No for batten:- STREAKT8UPTO 1X22WSSBSWH of make Havells "or" IGP161LT8-16 of make Crompton "or"TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved . Cat Part No for Tubelight:- PHOTANULTRAE2.0 1213T8SSTL18WLED865SPC of make Havells "or" LTT8-20 of make Crompton "or" MAS LED tube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
170Supply and FixLED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed. Make- Crompton/havells/bajaj
171Disconnecting/ Taking down Exhaust fan of any sweep removing and cleaning the dust properly, painting with same colour good quality synthethic enemelled paint after preparing surface for painting with existing color shade oiling and greasing of bearing including refixing and making the conection and testingcomplete all as specified and directed.
172Disconnecting/ Taking down ceilingfan of any sweep taking in safe custody and depositing in MES Store Yard, complete all as specified.
173Supply and fix Ceiling fan ISI marked, AC single phase 240V,complete with blades , down rods, electronic regulator and accessories, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 1200mm Min air delivery 210 CFM 5star rated with brushless direct current motor (BLDC) complete with connection from ceiling rose to exhaust fan all as specified and directed.
174Taking down andre-fixing electric water heater, storage typeany type25 litre,all as specified and directed.
175Disconnecting electronic meters temper proof LCD display and taking in safe custody and refixing the same with caliberation and cleaning and making the conection and testingcomplete all as specified and directed.
176Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
177Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
178GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
179XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
180Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
181Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 34 of tender doucments.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail