Military Engineer Services-MES has published Tender For Repairs Maintenance Of Summer Cooling Appliances At Nad, Mo V, Ncb, Ce Office Complex And Other Areas Under Age Em Of Ge Nd Visakhapatnam. Submission Date for this Tender is 04-03-2024. AMC of Air Condition Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Schedule "A" Part -I |
2 | M & L for defective / burnt out compressor from Split type air conditionerof upto 1.5 ton capacity in situ or at workshop and providing new compressor Rotary / Reciprocating for the job complete all as specified and directed. [Make: OEM or any equivalent approved make] Note:-The rate quoted will be included of full charging withrefrigerant gas , all electrical connection,testing and commissioning , cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, terminals etc as required |
3 | All as per item No. 1 above but for 2.0 Ton capacity floor mounted / tower model Split type AC Conditioner |
4 | All as per item No. 1 above but for inverter type wall mounted / tower model Split type AC Conditioner |
5 | All as per item No. 2 above but for inverter type wall mounted / tower model Split type AC Conditioner |
6 | All as per item No 1 here-in-before but for 3.5 ton capacity floor mounted / tower model cassette type air conditioner three phase 415 Volts |
7 | All as per item No 1 here-in-before but for 5.5 ton capacity floor mounted / tower model cassette type air conditioner three phase 415 Volts |
8 | All as per item No 1 here-in-before but for 7.5/8.5 ton capacity floor mounted / tower model cassette type air conditioner three phase 415 Volts |
9 | M & L for compressor suitable for refrigerator upto 400 litres (inverter / non-inverter) capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as directed. [Make: OEM or any equivalent approved make] |
10 | M & L for compressor suitable for Deep freezer of any capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as directed. [Make: OEM or any equivalent approved make] |
11 | M & L for compressor suitable for water cooler upto 150 litres capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as directed. [Make: OEM or any equivalent approved make] |
12 | Supply and charging of refrigerant gas suitable for window / split air conditioners / water coolers / refrigerators/Deep freezers complete all as directed. [Make: Floron / Mafron / Refron / National] |
13 | M & L for leak testing with N2 gas of indoor/outdoor unit upto 8.5 TR capacity, rectification of leaks by welding / brazing and pressure testing as per the standards and holding the pressure for 24 Hrs and observe for any pressure drop in the system including evacuation with vaccum machine complete all as directed. Note:-The rate quoted will be included of full charging withrefrigerant gas after leakage rectification,testing and commissioning , cost of cutting, brazing , sealing the refrigeration tubing,etc. |
14 | Supply and replace in repairs unserviceable indoor unit (inverter/non-inverter) blower fan motorupto 1.5 Ton capacity Split air conditioner with new fan motorsuitable for air conditioners 800 to 1250 RPM including testing complete all as directed. [Make: OEM or any equivalent approved make] |
15 | All as per item no 9 but for 2.0 TR |
16 | Supply and replace in repairs unserviceable outdoor unit (inverter/non-inverter)fan motorupto 1.5 Ton capacity Split air conditioner with new fan motorsuitable for air conditioners 800 to 1250 RPM including testing complete all as directed. [Make: OEM or any equivalent approved make] |
17 | All as per item no 11 but for 2.0 TR |
18 | Supply and replace unserviceable indoor blower fan motor forupto 2.0 Ton capacity Split air conditioner with new fan motor double shaft type suitable for air conditioners 800 to 1250 RPM including testing complete all as directed. [Make: Magic / National / CG / Usha] |
19 | Supply and replace unserviceable blower fan motorfor water cooler upto 150 Lit capacity complete all as directed. [Make: Magic / National / CG / Usha] |
20 | Supply and replace unserviceable blower fan blade for hot air / cool air suitable for split type air conditioner upto 2.0 Ton capacity, balancing for smooth rotation in the casing and testing complete all as directed. [Make: Magic / National / CG / Usha] |
21 | Supply and replace unserviceable blower fan blade for hot air / cool air suitable for floor mounted / tower model split type air conditioner upto 3.0 - 8.5 Ton capacity, balancing for smooth rotation in the casing and testing complete all as directed. [Make: Magic / National / CG / Usha] |
22 | Supply and replace unserviceable blower fan blade for water cooler upto 150 Ltr capacity balancing for smooth rotation in the casing and testing complete all as directed.[Make: Magic / National / CG / Usha] |
23 | Supply and replace old defective running capacitors with new capacitors 45 mfd rating suitable for 1.0/1.5Ton capacity air conditioners complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
24 | Supply and replace old defective running capacitors with new capacitors 50 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
25 | Supply and replace old defective running capacitors with new capacitors upto 25 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
26 | Supply and replace old defective starting capacitors with new capacitors 80-100 mfd rating suitable for 1.0/1.5 Ton capacity air conditioners/Watercooler complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
27 | Supply and replace old defective starting capacitors with new capacitors 100-120 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
28 | Supply and replace old defective starting capacitors with new capacitors 40-60 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
29 | Supply and replace old defective starting capacitors with new capacitors 60-80 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
30 | Supply and replace old defective capacitors with new capacitors 2.5 - 10 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners for fan motor complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon] |
31 | Supply and replace unserviceable copper condensation coil upto 2.0 Ton capacitysplit type air conditioner including testing complete all as directed. |
32 | Supply and replace unserviceable condensation coil 3.0 Ton capacity split type/tower/cascade air conditioner including testing complete all as directed. |
33 | Supply and replace unserviceable condensation coil 5.5 to 7.5 Ton capacity split type/tower/cascade type air conditioner including testing complete all as directed. |
34 | Supply and replace unserviceable condensation coil upto 150/150 Litres capacity water coolers including testing complete all as directed. |
35 | Supply and replace unserviceable condensation coil upto 400 Litres capacity Refrigerators/deepfreezer including testing complete all as directed. |
36 | Supply and replace unserviceable Evaporator coil upto 3.0 Ton capacity window / split type air conditioner including testing complete all as directed. |
37 | Supply and replace unserviceable single phase contactor suitable for Split air conditioners upto 2.0 Ton capacity complete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH] |
38 | Supply and replace unserviceable three phase contactor suitable for Split air conditioners up to 7.5 Ton capacity complete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH] |
39 | Supply and replace unserviceable Relay suitable for Split AC upto 3.0 Ton capacity complete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH] |
40 | M & L for servicing of Air conditioners (indoor unit and outdoor unit complete) of any make and capacity with electrical blower , cleaning with castic soda and soap water to all the parts including evaporator , condenser , grills, etc and checking of all the electrical connections, etc complete all as directed. |
41 | M & L for servicing of water coolers, Refrigerators and deep freezers of any make and capacity with electrical air blower and water pressure jet cleaning with castic soda and soap water to all the parts including evaporator, condenser, etc and checking of all the electrical connections, etc complete all as directed. |
42 | M & L for rewinding of unserviceable blower motor (indoor unit) / fan motor (outdoor unit) of any capacity Split type AC,including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testingcomplete all as directed. |
43 | M & L for rewinding of unserviceable blower fan of any capacity watercooler,including taking downthe motor completely, removing old burn out winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials , painting and fixing back the motor in original position including testingcomplete all as directed. |
44 | All as per item No. 36 above but for Refrigerators/Deep Freezer of any capacity. |
45 | Supply and replace air filters, non woven, synthetic, high efficiency washable type suitable for 1.5 / 2.0 Ton capacity Air conditioners complete all as directed. |
46 | Repairs to defective printed circuit board of Split AC (inverter/non-inverter)/ Window AC / water cooler / refrigerator of 230 Volts single phase any capacity complete all as directed. |
47 | Supply and replace unserviceable Electronic Printed Circuit board for inverter type Split AC of 1.5/2.0/3.0 Ton capacity for outdoor unit complete all as directed. |
48 | Supply and replace unserviceable Electronic Printed Circuit board for inverter type Split AC of 1.5/2.0/3.0 Ton capacity for indoor unit complete all as directed. |
49 | Supply and replace unserviceable solenoid valvefor inverter type Split AC of 1.5/2.0/3.0 Ton capacity for outdoor unit complete all as directed. [Make: OEM or any equivalent approved make] |
50 | Supply and replace unserviceable coil sensor/room sensor for inverter type Split AC of 1.5/2.0/3.0 Ton capacity for indoor unit complete all as directed. [Make: OEM or any equivalent approved make] |
51 | Supply and fix copper tubing 24 SWG of size5/8" along with tubular insulation suitable for Split AC complete all as specified and directed. |
52 | Supply and fix copper tubing 24 SWG of size1/2" along with tubular insulation suitable for Split AC complete all as specified and directed. |
53 | Supply and fix copper tubing 24 SWG of size1/4" along with tubular insulation suitable for Split AC complete all as specified and directed. |
54 | Supply and replace PVC drain pipe for split AC of 20mm bore complete all as specified and directed by Engineer-in-Charge. [Make: KISAN / JAIN IRRIGATION / FINOLEX / SUPREME / PRINCE] |
55 | Supply and replace Split AC Valves made of high grade free cutting brass and copper for pipe of size 1/2", 1/4", 3/8" and 5/8" complete all as specified and directed. |
56 | M & L for cutting and removing rusted steel body of Split AC / Window AC / Water coolers of any type and welding new MS sheet of suitable gauge including necessary bending as required and applying two coats of synthetic enamel paint over a coat of primer complete all as directed. [Make: ASIAN / SHALIMAR / BERGER / J & N] |
57 | Supply and replace copper capillary tube suitable for Split AC of 1.5 / 2.0 Ton capacity complete all as directed. |
58 | S & F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete including one MCB, SPN, 20 Amps, 240 volts, 10 KA complete all as specified and directed. |
59 | Supply and replace electronic remote control with hand set compatible for Split AC of 1.5 / 2.0 Ton capacity of existing make and model complete all as directed. |
60 | Repairs to Voltage stabiliser including replacing the defective parts like relay, bridge, transformer, glowing lamps and making serviceable for automatic operation, for input variation between 170 to 250 volt and output voltage stabilised at 230 volt with accuracy of + 2.5% of capacity 2.0/3.0/4.0 / 5.0 KVA complete all as directed. |
61 | Supply and replace lift/push cock chromium plated brass of 15mm size suitable for water cooler of capacity 40/80 Litres complete all as directed. |
62 | Supply and replace thermal insulation for indoor to outdoor copper pipe suitable for split type AC of any capacity complete all as directed. |
63 | Supply and replace Thermostat suitable for water cooler of capacity upto 150/150 Lit complete all as directed. [Make: Sporlon / Floron / U Flow / Honeywell / Siemens / Danfoss] |
64 | Supply and replace Overload protector suitable for water cooler of any capacitycomplete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH] |
65 | Supply and replace indoor unit of split type Air conditioner 1.5 Ton capacity suitable for existing outdoor unit complete all as directed. [Make: BLUE STAR / HITACHI / DAIKIN / CARRIER] |
66 | Supply and replace indoor unit of split type Air conditioner 2.0 Ton capacity suitable for existing outdoor unit complete all as directed. [Make: BLUE STAR / HITACHI / DAIKIN / CARRIER] |
67 | Supply and replace stainless steel drain tray made of SS 304 suitable for water coolers of any capacity complete all as directed. |
68 | Supply and replace non magnetic gasket top corner for water cooler complete all as specified |
69 | Supply and replace magnetic gasket for refrigerator complete all as specified |
70 | Supply and replace PVC cable of 3/4 core 4.0sqmm for connecting indoor unit to outdoor unit complete all as specified |
71 | Supply and replace Power Plug Top suitable for Split/Window AC/Refrig/Deep Freezer/Water Cooler for connecting in Power Socket complete all as specified |
72 | M&L for core cutting hole for AC drain pipe and copper tubing passing from indoor unit to outdoor unit in any type of wall complete including filling with cement motar forfilling the gap to match with the existing finish complete all as specified. |
73 | Supply and replace of swing motor of split/tower AC of any capacity complete all as specified |
74 | Supply and fixing of stand for outdoor unit of 1.5/2/3.0TR capacity including complete fixing of oudoor unit in suitablly in any location and any height all as specified and directed |
75 | M&L for shifting of split AC unit of any capacity and any make (indoor and outdoor complete) from one location to another after disconnecting from main supply and restoring refrigerant gas and installing in new location and connecting with electric supply line all as specified and directed. |
76 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA suitable for 1.5 TR AC |
77 | Supply and replace of HP/LP switch of 7.5/8TR AC of any type and make complete all as specified |
78 | Supply and replace of wire mesh of suitable size for outdoor unit complete all as specfied. |
79 | Supply and replacement of connector for AC of capacity 1.5/2/3TR for connecting the wire/cable from indoor unit to outdoor unit complete all as specified and directed. |
80 | Supply and Fixing 40mm dia PVC Drain Pipe including all accessories(ie Bend/Elbow/Tee/Reducer/GI Clamps etc) for connecting of Split AC drains in series on Building roof/Wall/Chhajja complete all as specified and directed. |
81 | S&Fwhite Rebon/ white Teplon role for insulation ofSplit AC outer copper tubes complete all as specified and directed. |