Tender For Junction Improvement Work Of Transport Nagar And Devalchaud Chauraha, Haldwani In Compliance With The Approval Of Road Safety Audit Committee, haldwani-Uttarakhand

Public Works Department-PWD has published Tender For Junction Improvement Work Of Transport Nagar And Devalchaud Chauraha, Haldwani In Compliance With The Approval Of Road Safety Audit Committee. Submission Date for this Tender is 22-02-2024. Road Work Tenders in haldwani Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

42172307
Tender For Junction Improvement Work Of Transport Nagar And Devalchaud Chauraha, Haldwani In Compliance With The Approval Of Road Safety Audit Committee
Open Tender
Indian
Uttarakhand
haldwani
22-02-2024

Tender Details

Junction Improvement Work Of Transport Nagar And Devalchaud Chauraha, Haldwani In Compliance With The Approval Of Road Safety Audit Committee

Key Value

Document Fees
INR 2360 /-
EMD
INR 56000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: lM+d nq?kZVuk U;wuhdj.k @ ;krk;kr lqj{kk dh –f"V ls gY}kuh "kgj ds vUrxZr jksM ls¶Vh v‚fMV lfefr ds vuqeksnu ds vuqikyu esa nsoypkSM+ tuD"ku dk lqèkkj dk;ZA
Sl. No. Item Description
1S/O hot dip Galvanized 12.5m high mast (In Two sections) 360 mm bottom, 100 mm top, 3/3 mm section thickness, PCD 445 mm with base plate of 520 x 25mm with 3 wire rope system and accessories. Accessories include head frame, lantern ring with 6 nos of lum arms (symmetrically arrangement) three wire ropes system power tool, AOL bracket, Foundation accesssories each set consists of 6 nos of M 24 x 850 mm bolts with Anchor plate and 10% templates.
2S/O high mast control panel as per SRL std-1 Control panel with 40 A MCB as incommer along with 32 A contactor and timer for auto switching ON/OFF of Luminiares. Also there facility to operate the power tool for raising and lowering of lantern carraige
3S/O LED type aviation obstruction Light, Double Dome type
4S/O 300W LED Flood light having PDC housing 300W ± 5W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor >0.95, Driver Efficiency >85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)<10% to 90% RH working Temp-10 C to+ 50C, System Efficacy 110 Lm/Watt.
5S/O hot dip Galvanised Steel OCTAGONAL POLE height = 4m, Top OAF= 70 mm, Bottom OAF-130, Thickness-3 mm, Base Plate-200 x 200x 12mm, PCD-200mm
6S/O foundation accessories set-each set consists of 4 nos of M 16x 600 J bolts plus 10% templates
7S/O 600mm single arm bracke, standard tiype 36.3/mm OD pipe
8S/O 45 W LED Flood light having PDC housing 45 W ± 2W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor >0.95, Driver Efficiency >85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)<10% to 90% RH working Temp-10 C to+ 50C, System Lumen 4900± 2%, System Efficacy110 Lm/WattLm 9 front NABL lab, LED Make- CREE/NICHI / OSRAM/LUMILEDS CRS is mandatory should have vailed ISO
9S/O hot dip Galvanised Steel OCTAGONAL POLE height = 6m, Top OAF= 70 mm, Bottom OAF-130, Thickness-3 mm, Base Plate-200 x 200x 12mm, PCD-200mm
10S/O foundation accessories set-each set consists of 4 nos of M 20x 750J bolts plus 10% templates
11S/O 1000mm single arm bracke, standard tiype 36.3/mm OD pipe
12S/O 70 W LED Flood light having PDC housing 70 W ± 2W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor >0.95, Driver Efficiency >85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)<10% to 90% RH working Temp-10 C to+ 50C, System Lumen 4900± 2%, System Efficacy110 Lm/WattLm 9 front NABL lab, LED Make- CREE/NICHI / OSRAM/LUMILEDS CRS is mandatory should have vailed ISO
13S/O hot dip Galvanised Steel OCTAGONAL POLE height = 7m, Top OAF= 70 mm, Bottom OAF-130, Thickness-3 mm, Base Plate-200 x 200x 12mm, PCD-200mm
14S/O foundation accessories set-each set consists of 4 nos of M 16x 600 J bolts plus 10% templates
15S/O 1000mm Double arm bracke, standard tiype 36.3/mm OD pipe
16S/O 90 W LED Flood light having PDC housing 90 W ± 2W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor >0.95, Driver Efficiency >85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)<10% to 90% RH working Temp-10 C to+ 50C, System Lumen 4900± 2%, System Efficacy110 Lm/WattLm 9 front NABL lab, LED Make- CREE/NICHI / OSRAM/LUMILEDS CRS is mandatory should have vailed ISO
17Centralized Auto On off Timer, 12 w Three Phase Automatic Strell light cubical panel feeder box with Astronomical Timer Complete
18S/L of 4x 6 sq mm Al. armoured cable
19S/L of 4x 10 sq mm Al. armoured cable
20S/L of 50 mm dia GI pipe
21Supplying and drawing 3 x 1.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
22Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
23Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
24Supplying and laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
25Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Disclaimer :