Tender For Maintenance Replacement Of Certain B R Works Unsv Pipes Valves Pit Chambers Renewal Of Earthing Alongwith Cleaning Of Ug Sump, bengdubi-West Bengal

Military Engineer Services-MES has published Tender For Maintenance Replacement Of Certain B R Works Unsv Pipes Valves Pit Chambers Renewal Of Earthing Alongwith Cleaning Of Ug Sump. Submission Date for this Tender is 02-03-2024. Electrification Work Tenders in bengdubi West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42168260
Corrigendum : Tender For Maintenance Replacement Of Certain B R Works Unsv Pipes Valves Pit Chambers Renewal Of Earthing Alongwith Cleaning Of Ug Sump
Open Tender
Indian
West Bengal
bengdubi
02-03-2024

Tender Details

Maintenance Replacement Of Certain B R Works Unsv Pipes Valves Pit Chambers Renewal Of Earthing Alongwith Cleaning Of Ug Sump Maintenance Replacement Of Certain B R Works Unsv Pipes Valves Pit Chambers Renewal Of Earthing Alongwith Cleaning Of Ug Sump Rcc Overhead Tank And Pcc Tank Etc At Certain Locations Under Age E M And Age B R Ii Of Ge Bengdubi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Feb-2024 BOQ Corrigendum BOQ 02-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: MAINTENANCE / REPLACEMENT OF CERTAIN B/R WORKS, UNSV PIPES, VALVES, PIT CHAMBERS, RENEWAL OF EARTHING ALONGWITH CLEANING OF UG SUMP, RCC OVERHEAD TANK AND PCC TANK ETC AT CERTAIN LOCATIONS UNDER AGE E/M AND AGE B/R-II OF GE BENGDUBI
Sl. No. Item Description
1B/R Items: Excavating inpost holes( or similar holes) each n exc0.50 cum , getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed.
2M&L for PCC 1:3:6using 40mm graded stone aggregate, type C2 asin foundation filling & mass concrete complete all as specified and directed.
3M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
4M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165and similar workcomplete all as specified and directed.
5S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longcomplete all as specified and directed.
6M&L forMild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
7M&L forrolled sections as in main and cross beams, hip and jack rafters, purlins where connected to comman rafters and running railsfixed with angle cleats or other connecting plates conforming to Fe 410 W (Gde E-250) quality-A including welded to rafter,purlin complete all as specified and directed.
8M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conformingFe-410W(GdeE-250) quality -A complete all as specified and directed.
9S&F MSframed work confirming to Fe 410 -W quality Aas in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
10Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Posts embedded in Concrete, brick work, masonry, etccomplete all as specified and directed.
11Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wirecomplete all as specified and directed.
12S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed. (each line wire to be measured)
13M&L Running welding in repairs to gates, doors, hold fast of doors on metal thickness n exc 6mm complete all as specified and directed.
14Supply only Chain link MS galvanisd fencing, any size or type all as specified and directed.
15S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed.
16S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed.
17M&L for 75mm thick PCC 1:3:6 type C1(Using 20mm graded stone aggregate) as in plinth protectionfinishedeven and smoothwithout using extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed.
18M&L for 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregates)as in flooring, rough finished for hard stading completeall as specified and directed.
19Dismantling of floor, hearth or wall tiling / Paving Blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
20Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
21Taking down existing un-sreviceable water proofing treatment from roof slab and slab and cleaning the roof by wire brush and removing WPT felt beyond the MOD premises etc. cement plaster on brick or stone walls, etc.complete all as specified and directed.
22M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed.
23Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed.
24Demolition of cement concretein ground floorand paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed.
25Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
26Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified and directed
27M&L for Glazed ceramic tiles coloured 300mmx 450mm , 6 to 7 mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface etc complete all as specified and directed.
28M&L for pre polished coloured cement concrete chequred tile of size 300x300x25mm with grey cement and no pigment of approved quality on floors over and including 15 mm thick screed bed cement mortar 1:6 set and jointed in neat cement slurry and pointed with colour to match the tiles complete all as specified and directed.
29M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; completeall as specified and directed.
30M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
31M&L for preparation of new undecorated surface of wall and applying two coats of white wash complete all as specified and directed.
32Material & Labour for prepration of old surfaces including complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over existing surfaces of height upto 25mtrs from ground level complete all as specified and directed. (Note: Rate for scaffolding and all misc connected materials for painting upto 25mtrs to be considered in quoted rate)
33Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitionsetc complete all as specified and as directed.
34M&L for surface preparationfree from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating prime the surface with water including removal of all existing treatment, bituminious membrane, tarfelt.screed concrete etc from RCC roof slab complete all as specified and directed.
35M&L for waterproofing coating by providing and applying Fostoc Brushbond Roof Guard of FOSROC or equivalent of SIKA/STP , a single component High build fibre Reinforced Acrylic Waterproofing render for roofing system applied by brush, at three coats at minimum dry film thickness of 1 mm, cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as per manufacturer specification, specified and directed. Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2 h
36E/M Items: Excavation in trenches not exceeding 1.50 m wide and 1.5 mtr depth for foundation etc, not exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
37Returning filling in including spreading, leveling watering well ramming in layers not exc 25cm thick complete all as specified and directed.
38Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
39M&L for PCC 1:3:6 type C2 using 40 mm grade cruhed stone aggregate for making good the road/path etc complete all as specified and directed.
40M&L for surface excavation n.exc 30 cm deep and averaging 15 cm deep getting out in soft/loose soil for cleaning and cutting of grass/bushes (at zero level) in and around the installation / yard and spreading thin layer of anti-vegitaion chemical to prevent abnormal growth of grass/bushes including removal of surplus soil complete all as specified and directed. (Note :- The above item shall be carried out through out the contract period as and when required and shall measured and paid once only)
41Taking down GI pipes 15 mm dia from trenches/walls etc complete all as specified and directed.
42Taking down GI pipes 20 mm dia from trenches/walls etc complete all as specified and directed.
43Taking down GI pipes 25 mm dia from trenches/walls etc complete all as specified and directed.
44Taking down GI pipes 40 mm dia from trenches/walls etc complete all as specified and directed.
45Taking down GI pipes 50 mm dia from trenches/walls etc complete all as specified and directed.
46Taking down GI pipes 80 mm dia from trenches/walls etc complete all as specified and directed.
47Taking down GI pipes 100 mm dia from trenches/walls etc complete all as specified and directed.
48Labour onlyfor refixing steel water tubing medium grade galvanised with new fitting laid in trenches/wall obtained from item No. 41 to 47 here-in-before for the following sizes :
4915 mmBore.
5020 mmBore.
5125 mmBore.
5240 mmBore.
5350 mmBore.
5480 mmBore.
55100 mmBore.
56M&L for steel water tubing medium grade galvanised with new fitting laid in trenches for the following sizes :-
5715 mmBore.
5820 mmBore.
5925 mmBore.
6040 mmBore.
6150 mmBore.
6280 mmBore.
63100 mmBore.
64S&F PPR (Poly Propylene random co-polymer) pipe size 90mm OD, PN-10 (SDR-11) IS-15801, 3-layer (outer green coloured UV stablized, middle black coloured UV stablizer and innermost layer white coloured with anti-microbial property) having thermal stability for hot & cold water supply with and including all necessary PPR plain and brass threaded fittings, laid in trenches complete all as specified & directed. (NOTE:- Contractor shall give 7 years warranrty certificate of the manufacturing defect and leak proof material & 50 years product life certificate will be submitted before RAR process).
65Taking down unserviceable sluice valve 80 mm dia complect all as specfied and directed.
66Taking down unserviceable sluice valve 100 mm dia complect all as specfied and directed.
67Taking down unserviceable sluice valve 150 mm dia complect all as specfied and directed.
68Taking down unserviceable sluice valve 200/250 mm dia complect all as specfied and directed.
69S&F sluice valve cast iron confirming to IS : 14846 both end flanged with S/S spindle with nut class PN - 1.0 ISI marked complete with hand wheel nuts, bolts, washers & rubber gusket etcfor the sizes complete all as specified & directed.
7080 mm bore
71100 mm bore
72150 mm bore
73200 mm bore
74250 mm bore
75Taking down unserviceable Air release valve 80 mm dia complect all as specfied and directed.
76S&F Cast Iron Air release valves conforming to IS 14845-2000 with tamper proof arrangement of size 80 mm bore complete all as specified and directed.
77M&L for construction of brick masonry valve pit of size 1200x1200x900mm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation, and 15mm thick rendering in cement mortor (1:4) internally, externally up to 15cm below GL, providing valve pit cover made of 3 mm thick MS sheet/plate, welded with 40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embeded in PCC 1:2:4 type B-1 (20mm graded aggregate) block of size 230 x 200 x 100mm and provision of hinges, handle and locking arrangement including two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer and necessary excavation and earth work in soft/loose soil including dismantling of existing valve pit complete all as specified & directed.
78M&L for construction of brick masonry valve pit of size 900x900x900mm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation, and 15mm thick rendering in cement mortor (1:4) internally, externally up to 15cm below GL, providing valve pit cover made of 3 mm thick MS sheet/plate, welded with 40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embeded in PCC 1:2:4 type B-1 (20mm graded aggregate) block of size 230 x 200 x 100mm and provision of hinges, handle and locking arrangement including two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer and necessary excavation and earth work in soft/loose soil including dismantling of existing valve pit complete all as specified & directed.
79S&F mild steel machine made nuts, bolts & washers of size 15mm(5/8”) dia and 75mm (3”) long or nearest suitable sizes for top cover and side cover of Soda /Alum pot complete all as specified and directed.
80M&L and repair for LED Aviation/ Obstruction Light installed on The Roof of Overhead reservoir or on High mast light complete all as specified and directed.
81Supply and Fix in repairs Smart metal water level indicator with alarm on full tank with 05 no sensors of stainless steel molded with polypropylene contact type water level sensor for overhead water tank complete all as specified and directed.
82Taking down CI pipes 80 mm dia, Checking, cleaning internally by using steel brush /scrubber throughly to remove all rusts/slit/mud etc from pipe and Keep the Serviceable pipes & Lead in safe custody for refixing in existing/new positionincluding replacing worn out Sockets, nuts, bolts, flange, gasket complete all as specified and directed.
83All as per item No. 63.00 above but for 100 mm dia.
84All as per item No. 63.00 above but for 150 mm dia.
85All as per item No. 63.00 above but for 200 mm dia.
86All as per item No. 63.00 above but for 250 mm dia.
87Labour onlyfor refixing CI Pipes any type with fittings fixed to floor / laid in trench obtained from item No. 63 to 67 here-in-before for the following sizes :-
8880 mmBore.
89100 mmBore.
90150 mmBore.
91200 mmBore.
92250 mmBore.
93Supply, jointing, laying and testing in standard length, centrifugally cast (spun) ductile iron (DI) pressure pipes with inside cement mortor lining and black bitumen external coating, nominal diameter, class K-7 classification, confirming to IS-8329 including push on and rubber gasket joints and jointing necessary DI specials etc complete all as specified and directed. (Note:- DI special/ fitting will be measured and paid seperately under relevent item of SCh"A"/BoQ)
9480 mmBore.
95100 mmBore.
96150 mmBore.
97200 mmBore.
98250 mmBore.
99M&L for attending pipe line break down of CI pipe of 80 mm dia by making lead joint with lead and spun yarn and moulding clay including taking up/down pipe using chain pulley or rope and excavation in any type of soil,returning filling and removel of soil all as specified and testing of pipe line complete all as specified and directed.
100All as per item no. 70.00 here-in-before but CI pipe of dia 100 mm
101All as per item no. 70.00 here-in-before but CI pipe of dia 150 mm
102All as per item no. 70.00 here-in-before but CI pipe of dia 250 mm
103All as as per item no. 70.00 here-in-before but CI pipe of dia 300 mm
104M&L for run lead joints for CI pipe of following bore of pipe with spun yarn and complete testing :-
10580 mmBore.
106100 mmBore.
107150 mmBore.
108200 mmBore.
109250 mmBore.
110300 mmBore.
111M&L for Tyton rubber joint of size 100 mm dia complete all as specified and directed.
112M&L for Tyton rubber joint of size 150 mm dia complete all as specified and directed.
113M&L for Tyton rubber joint of size 200 mm dia complete all as specified and directed.
114M&L for Tyton rubber joint of size 250 mm dia complete all as specified and directed.
115M&L for Tyton rubber joint of size 300 mm dia complete all as specified and directed.
116S&F CI/DI bends (any type, radius and angel) tapers any type (straingh, bend, increasing, decreasing or double socket etc) tee pieces single brancehs "Y" junction double branch, cross (all socket or socket and spigot) collars, caps and plugs for following bore of pipes :-
117Upto 150 mm bore
118200 mm to 300 mm bore
119Supply, installation, testing, and commissioing 3 phase and neutral, 415 volts indoor type Feeder pilar box "pedastal type" confirming to IP 43, CPRI approved, factory fabricated & factory assembled, water proof, dust and vermin proof cubical type with locking arrangement, LT Penal made out of suitable size angle iron, chennel and fabricatedfrom 3.15mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicationg lamps with & including busbars made of copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours, Bus bar shell be properly supported/mounted on epoxy insulators, All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connectingsultable earth strips, Suitable openable doors shall be provided for all operational switch gear and MCCBs and detchable cover shall be provided on all other accessories, Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6 (type C-I using 20mm grade stone aggregate ) complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper conductor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electril supply. INCOMING (a) MCCB 4 pole, 415 Volts, 200 Amps, 25 KA, 100% Icu- 01 No Make- Legrand/L&T/ABB/Havells OUTGOING (a) MCCB 4 pole, 415 Volts, 100 Amps, 25 KA, 100% ICU-02 Nos. (b) 3 PH, Star-Delta Starter for 5.0 - 25.0 HP Pump-motor Set - 02 Nos with following Protection:- i) Single Phase. ii) Overload iii)PhaseReversal. iv) Phase Imbalance. v) Over & under voltage. Make: C&S/L&T/Legrand/BCH. (c) Digital Voltmeter 0-500 V with selector switch - 01 No. (d) Digital Ammeter 0-200 Amps with CTs and selector switch- 01 No (e) Copper bus bar 4 strip (electro -plated with aluminium) 01 Set (f) indicator lamps (RYB) (set of three -01 Set (g) Spare - 01No
120M/L for PVC syntax capacity of 50000 Ltr cleaning throw bacteriological treatment TRABAC-G-05, TERBAC- G 65 at any height as per site requirement all as specified and directed.
121M&L for sixstage cleaning and sterloization inside the existing RCC UG water well (Jack well/Shallow well) of capacity 88000 gallon(approx) Size::Dia 6M, Depth-15 M through bacteriological treatment using TERBAC-G05. TERBAC-G65 or eqct at pump House included suitable staging for lowering & instllation of pump at any depth as required at site all directed by Engr-in -charge incl seven stages are as uinder:- (a) First stage is to drain out the water by using exit valve or our own high capacity dewatering system. (b) Second stage is cleaning all ther algae formation side inside the tank uising TERBAC G10 or equivalent a laboratory tested branded chemical of the company and scrubbing the walls of tanks. (c) Third stage is scrubbing the walls with mechanised scrubber & fresh cleaning. (d) Fourth stage is and first bacteria screening is sterilisation by using TERBAC-G5 or equivalent a Govt Laboratory certified branded halogen compound test certificate of TERBAC -G5 or equivalent from PHED or Authorised labaratory mentioning suitablity for sterilization should be submitted to the office before using for sterilization. (e) Fifth stage is cleaning the floor of the water tank. (f) Sixth stage of cleaning and third bacteria screening is to sterilize the floor of the water well by the using loaboratory certified branded strong oxidizing agent TERBAC-G65 or equivalent test certified of of TERBAC-G65 or equivalent from PHED or authorised laboratory mentioning suitability for sterilizarion should be submitted to the office before using for sterilizarion
122M&L for six stage cleaning and sterloization inside the existing RCC overhead water tank of capacity 75000 gallon through bacteriological treatment by using TERBAC-G5, TERBAC-G65 or equivalent at pump house at any height (as per site requirement) all directed by Engr-in-charge including stagging seven stage are as under:- (a) First stage is to drain out the water by using exit valve or our own high capacity dewatering system. (b) Second stage is cleaning all ther algae formation side inside the tank uising TERBAC G10 or equivalent a laboratory tested branded chemical of the company and scrubbing the walls of tanks. (c) Third stage is scrubbing the walls with mechanised scrubber & fresh cleaning. (d) Fourth stage is and first bacteria screening is sterilisation by using TERBAC-G5 or equivalent a Govt Laboratory certified branded halogen compound test certificate of TERBAC -G5 or equivalent from PHED or Authorised labaratory mentioning suitablity for sterilization should be submitted to the office before using for sterilization. (e) Fifth stage is cleaning the floor of the water tank. (f) Sixth stage of cleaning and third bacteria screening is to sterilize the floor of the water well by the using loaboratory certified branded strong oxidizing agent TERBAC-G65 or equivalent test certified of of TERBAC-G65 or equivalent from PHED or authorised laboratory mentioning suitability for sterilizarion should be submitted to the office before using for sterilizarion
123S&F in repairs Gun metal gate valve, Cast Copper alloy, screwed down high pressure with Crutch or Butterfly handle screwed both ends for iron pipe complete all as specified and directed for the following size:-
12420 mm
12525 mm
12640 mm
12750 mm
128(Note : The Scope of Work contained in "Sch of Credit" amounting to Rs. 1,09,105.00 (refer Tender Srl Page No 33). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
Disclaimer :