Tender For Repair To Storm Water Drainage System ,Fencing ,Wall Footpath ,Hardstanding Including Other Misc B/R Items At Mo (Mb) Ghatkopar Under Ge(Nw) Bhandup, ghatkopar-Maharashtra

Military Engineer Services-MES has published Tender For Repair To Storm Water Drainage System ,Fencing ,Wall Footpath ,Hardstanding Including Other Misc B/R Items At Mo (Mb) Ghatkopar Under Ge(Nw) Bhandup. Submission Date for this Tender is 09-03-2024. Drainage Tenders in ghatkopar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42168250
Corrigendum : Tender For Repair To Storm Water Drainage System ,Fencing ,Wall Footpath ,Hardstanding Including Other Misc B/R Items At Mo (Mb) Ghatkopar Under Ge(Nw) Bhandup
Open Tender
Indian
Maharashtra
ghatkopar
09-03-2024

Tender Details

Repair To Storm Water Drainage System ,Fencing ,Wall Footpath ,Hardstanding Including Other Misc B/R Items At Mo (Mb) Ghatkopar Under Ge(Nw) Bhandup

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work : REPAIR TO STORM WATER DRAINAGE SYSTEM ,FENCING ,WALL FOOTPATH ,HARDSTANDING INCLUDING OTHER MISC B/R ITEMS ATMO(MB) GHATKOPAR UNDER GE(NW) BHANDUP
Sl. No. Item Description
1Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
2Dismantling of old barbed wire fencing complete all as specified and directed.
3Demolition of cement concrete (un reinforced) of any descriptionin any position not otherwise specifically provided complete all as specified and directed.
4Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
5Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level complete all as specified and directed.
6Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
7M&L PCC (1:4:8) type B2 using 40mm graded agg as in foundation mass concrete complete all as specified and directed by Engineer-in-Charge.
8M&L for brick work with fly ash bricks old size bricks in cement mortar, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as spd as directed
9M&L 15mm thick in CM 1:4 rendering on fair faces of brick work is to be finished even and smooth (without using extra cement) complete all as spd as directed
10M&L rendering 15 mm thick in CM 1:6 on brick masonary or concrete surfaces ofwall surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed.
11M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over a coatwhite wash complete all as specified and directed.
12M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemperincluding application of white cement based wall care puttyfinish (3mm thick) for smooth finish.etc complete all as specified and directed.
13Preparation of new steel surfaces exc 10 cm width or girth and applying two coats of syntetic enamel paint overone coat of red oxide of zinc chrome primer complete all as spd &directed .
14M&L Providing Cement concrete Type C2 1:2:4 (20 mm graded aggregate) in surface channels and drains complete all as spd as directed
15M&L forPCC Type B1 (1:2:4) for copings on brick wall surfaces including weathering, slightly rounded or chamferred angles and throating complete all as specified and directed.
16M& L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed
17M&LSand filling under floors or in foundationincluding watering and consolidation complete all as specified and directed.
18M&L forMachine pressed (LAQUER FINISH)cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of60mm thickness, M-35 Grade,machine pressed of pattern and colour as approved by GE complete all as specified and directed.
19M&L forMachine pressed (LAQUER FINISH) cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of 80 mm thickness, M-40 Grade,machine pressed of pattern and colour as approved by GE complete all as specified and directed.
20M&L for PCC (1:2:4) type B1 using 20mm graded aggregate for machine pressesd precast cement concrete kerb stone including weathering, slightly rounded or chemferred angles and throating , as directed edges complete including excavavtion for kerb stone complete all as specified and directed.
21M & L 25 mm thick PCC 1:2:4type B0, using 12.5mm graded aggregate as in floors toreceive surface of tile complete all as specified and directed.
22M&L screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
23M&L for coloured glazed chequered liquid finish cement concrete30cm x 30cm x 25cm thick With mixture of grey and white cement in equal proportions and no pigment set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
24S&F in repair MS steel work in tubular trusses for sign board posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as spd as directed
25S&F Welded steel wire fabric weight n exc 4 kg/sqm supplied and fixedcomplete to wood or steel members complete all as specified and directed.
26S&F Pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
27M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation and filling around fencing post complete all as spd & directed .(Deduction for the portion of fencing post/strut embeded in concrete shall be made)
28M&L 20-22 mm thick Granite of any colour(tablee rubbed and polished) as in windows cill , in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including form work , pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as spd as directed
29S&Fin repair of razer type concertina coil , 9 SWGhot galvanized spring tensile wire 145 to 150newton per square mm , zinc coating 250-300 gram per sqmdia of coil when unstretched 610mm minimum no of coil 10 per RM affter laying hot dip galvanised razer ribbon tape of size 0.50mm thick 19mm wide before wrapping of central corewise fixed with 1.66mm thk GI clips 25 nos per running meter and special nut bolt hold Z coil together and extra two rows parrel wire of 10 gauge complete all as specified and directed by EIC and dismantling of razer type concertina coil with two parallel rows of wire remove of the debris out side MD land complete all as specifide and directed by EIC
30S&F M S Posts and struts in fencing (any size of angle) mm including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagnal faces of each pannel to be intertwined with Chain link fencing, and fixed to posts with MS nut bolts and washers ,wind ties for sign board posts and struts, andsimilar work confirming to Fe 290 Gde E-165 complete al as spd and directed
31M&L for Formwork to sides of Rough finished surfaces of concretefoundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
32S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts including securing of typing at crossings with provision of galvanised mild steel wire staple or steel pin as directed (each line of wire to be measured) complete all as spd & directed
33S&F mild steelgrills framed work as such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways, MS railings framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 all as specified and directed.
34S & F 1.25 mm thick Mild steel, plain black sheet in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc as required complete including cutting out of existing sheet if required all as spd as directed
35S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing FE 290 Gde E-165 complete all as specified and directed.
36Supply only MS accessories for Gate repair such as shaft helical prings , pully ,lath sheets ,cast iron wheels, nuts/bolt, etc complete all as specified and directed.
37M&L forreinforced cement concrete M-30 (20 mm graded aggregates)(nominal mix) as in drain cover slabssupported on wall with cast in situ incl form work (width of drainn exc 3.0 mtr) complete all as specified (reinforcement to be measured & paid under respective items).
38Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified and directed.
39M& L for walling of random rubble masonry uncoursed well bonded and built in cement mortar 1;6 complete all as specifide and directed .
40All as per item No.39 above but for old stone masonary (Except stone ) complete all as specified and directed
41M&L for Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints in random rubble walling, uncoursed with maximum depression 40 mm on face fromstraight edge of granite or trapstone of face bed & joints as specified of random ruble walling uncoursed or brought up tp course copmplete all as specified and directed .
42M& L for Racking out joints / pointing to random rubble or polygonal rubbel uncoursed or brought up to courses built in cement mortar complete all as specified and direted
43M&L for raised pointing to random rubble or polygonal rubble uncoursed masonry in CM 1: 4 complete all as speified and directed .
44M&L Providing precast ce- ment concrete 1:2:4 Type B-1 (using 20 mm graded aggregate ) in window or door grills, lintels,bressumers, steps,quoin blocks (for use with masonry), string courses, copings.kneelers, apex stones, pier caps,columns, posts,boundary pillars,bed plates, pintle blocks, anchorage blocks, bonders (for stonelling).corbels, brackets,etc. (of any section indicated), with plain fair faces,including chamfers, weatherings,throating etc. and setting in mortar complete with joints to match complete all as speified and directed
45M&L for 20 mm thick broken glass coping in cement mortar 1:3 on top of wall complete all as specified and directed.
46M&L for reinforced concrete pipes class NP-2 ,450 mm dia laid and jointed complete with collars andall as specifed and directed.
47S&F for Stainless steel railing special alloy (grade 304) pipe 1.50 mm thick and any dia of pipe, incl necessary cutting , notching organ welding , grinding and drilling counter sunk holes and bending required shape by mechanical means in factory as per requirement without forming wrinkles and butting polishing complete all as specified and directed.
48M&L for Aluminium composite panel 4 mm thick work for partition wall and necessary fittings and fixing arrangement and finishing complete all as specified and directed.
49Preparation of Old surface of wall by filling cracks by fill paste of Crack fillier as approved by GE , removing loose paint etc ,removing nails etc and making good surface by applying two coat of wall care putty 1 mm thick in complete area ,smoothen surface by sand paper and applying twocoatofexterior paint over coat of primer complete all as spd & directed .
50M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemperincluding application of white cement based wall care puttyfinish (3mm thick) for smooth finish.etc complete all as specified and directed.
51M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
52M&L for Mild framed works such as angles, tees , channels, etc as in fenching posts large and small gates and grills , gratings and chainlink fenching etc, including hanging gates in pillar with proper pintle hinges, stops, hand made sliding bolts ,etc complete all as specified and directed. (For Y angles).
53M&L for reinforced cement concrete with design Mix M-30using 20mm graded stone aggregate in pillars, piers, posts and struts complete all as specified and directed.
54Deduct Credit for Demolished/ Dismantled material Rs. (-) 46000.00 (Minus) as listed in Schedule of CreditNote1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the "Contract Sum" Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail