Tender For Provision Of Retaining Wall, Uncovered Pathway With Chequered Tiles, Provn Of Electric Supply At Signal Complex And Provn Of Electrical Appliances Under Age (I) Tawang, Siliguri-West Bengal

Military Engineer Services-MES has published Tender For Provision Of Retaining Wall, Uncovered Pathway With Chequered Tiles, Provn Of Electric Supply At Signal Complex And Provn Of Electrical Appliances Under Age (I) Tawang. Submission Date for this Tender is 09-03-2024. Wall construction Tenders in Siliguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42167532
Tender For Provision Of Retaining Wall, Uncovered Pathway With Chequered Tiles, Provn Of Electric Supply At Signal Complex And Provn Of Electrical Appliances Under Age (I) Tawang
Open Tender
Indian
West Bengal
Siliguri
09-03-2024

Tender Details

Tender For Provision Of Retaining Wall, Uncovered Pathway With Chequered Tiles, Provn Of Electric Supply At Signal Complex And Provn Of Electrical Appliances Under Age ( I ) Tawang

Key Value

Document Fees
INR 1000 /-
EMD
INR 119500.0 /-
Tender Value
INR 63 Lakhs /-

BOQ Items

Nature of Work: PROVN OF RETAINING WALL, UNCOVERED PATHWAY WITH CHEQUERED TILES, PROVN OF ELECTRIC SUPPLY AT SIGNAL COMPLEX AND PROVNOF ELECTRICAL APPLIANCES UNDER AGE (I) TAWANG
Sl. No. Item Description
1Excavating over areasexc 1.5 m deep and getting out in Hard dense Soil complete all as specified and directed.
2M&L for Hardcore of Broken stone ofgauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface and rolled with 8 to 12 tonne power roller, complete all as specified and directed.
3M/LPCC 1:4:8 type D-2 using 40 mm graded stone aggr as in foundation filling and mass concrete complete all as specified and directed.
4Material and labour for walling of random rubble uncoursed ,well bonded stone massonary bedded and solidly hearted built in cement mortar 1:4 complete all as specified and directed.
5M&L of PCC 1:3:6 type C1 using 20mm graded stone aggregate as in bond stone , bed platesand set in cement mortar 1:4 complete all as specified and directed.
6Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level with broken stone/ boulders complete all as specified and directed.
7M&L for raised pointing to uncoursed Random Rubble masonaryin CM (1:4) complete all as specified and directed.
8M&L for 1:2:4 type B1(20mm graded stone aggregate)in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like e including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
9S&F PVC (SWR) pipes 75 mm bore, single socketed of pressure rating 6 kg/cm2 in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
10Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, back side of the wall complete all as specified and directed.
11Removing excavated materials exceeding 50 Mbut not exceding 100 M and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
12M&L for 100 mm thick Plain cement concrete 1:2:4 type B 2 (using 40mm graded aggregate), as in top layer of the floor, complete all as specified and directed.
13M & L screed bed or bedding layer of mortar (1:4) 15mm thick for Tiles laying floor finishers
14M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set and jointedin neat cement slurry and pointed with white cement and pigments in floor, complete all as specified and directed.
15S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5 Core complete all as specified and directed.
16S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2.0 Core complete all as specified and directed.
17M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, etc. or for laying of cable, pier holes, etc. nexc 10 sq m on plan andn exc 1.5 m in depth and getting out in soft & loose soil complete all as specified and directed.
18M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of any type of soil
19M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of any type of soil complete all as specified and directed.
20Cement concrete in foundations, filling and massconcrete Type C2,1:3:6 with 40 mm graded stone complete all as specified and directed.
21S&F DWC High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size inner dia 50 mm outer dia 63 mm complete all as specified and directed.
22S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size inner dia 75 mm outer dia 90 mm complete all as specified and directed.
23Supply install testing commissioning of LT panel board out door type of size 1300 x 950 mm, floor mounted, free standing , dust and vermin proof,fabricated from 3.15 mm CRCA sheet,finished with powder coating & providing 200 Amp TPN aluminiumr Bus bar and wiring consisting of following items:- Incoming :- (i) MCCB 250 Amp,4 P,30 KA with spreader link : - 01 No (Havells) (ii) Digital voltmeter (0-500 V),CL-1 with selector switch - 01 No (ABB) (iii) Digital Ammeter (0-100 A),CL-1 with selector switch - 01 No (ABB) (iv) CT 100/5A,Tape wounded (v) LED Type indication lamp ,RYB - 01 Set (vi) MCB SP 6 A - 03 Nos (Havells) Out going :- (i) MCB SPN 40 A, 10 KA - 20 Nos (Havells)
24S&F GI Pipe 50 mm bore, "light grade",galvanised,with all fitting;laid in trenches complete all as specified and directed.
25M&L Wiring for circuit/submain wiring alongwith earth wire with the two run of 4.0 sqmm + 1x4.0 sq mm for earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed.
26Supply and fixing MCB 40 Amp SPN 240V, 10KA "C"complete with connection testing and commissioning complete all as specified and directed.
27M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 25x4mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 32 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed..
28M&L for point wiringwith two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawing through in and including PVC casing & cappingof size not less than 20mm on surface of wall including provn of PVC box of suitable size for mounting modular type switch, socketalong with earth wire of PVC insulated, unseathed,1100 V grade cable multi stranded copper conductor of size 2.5 sqmm for One 3 pin socket outlet, 5 Amps, independent board complete all as specified and directed.
29S&FModular switch 1 way 16A,1 module complete all as specified and directed.
30S&FSocket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
31S&F sheet metal enclosuredistribution box4 way SPN 230 volts with 200 Amps rated bus bar double door complete including connecting up all as specified
32Supply and fixing MCB 32 Amp SPN 240V, 10KA "C"complete with connection testing and commissioning.
33Supply and fixing MCB 5- 32 Amp SP 240V, 10KA "C"complete with connection testing and commissioning.
34Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Starrated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed.
35S&F Refrigerator ,Electric driven (single phase) ,capacity 224 Ltrs,BEE 5 star rated of make LG/Blue star/Voltas/LG complete all as specified and directed
36Supply, installation, commis-sioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz of capacity 320 Ltr complete all as specified and directed.
37Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core 10 sq mm cable flat or circular complete all as specified and directed.
38Supplying and fixing House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 90 degree bends. M.S. hook and stay or guy complete all as specified and directed.
39Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers connected to and including GI earth wire 4.0 mm dia upto 7.5 mtr by means of bolts, nuts, check nuts and washers, and protected by light grade 20 mm dia and connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with P C C 1:2:4 Type C2 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009