Tender For Repair Maintenance Of Ac Plants, Cooling Appliances And Other Connected Misc Works At Af Stn Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Tender For Repair Maintenance Of Ac Plants, Cooling Appliances And Other Connected Misc Works At Af Stn Pathankot. Submission Date for this Tender is 02-03-2024. Air Conditioner Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42167024
Corrigendum : Tender For Repair Maintenance Of Ac Plants, Cooling Appliances And Other Connected Misc Works At Af Stn Pathankot
Open Tender
Indian
Punjab
pathankot
02-03-2024

Tender Details

Tender For Repair Maintenance Of Ac Plants, Cooling Appliances And Other Connected Misc Works At Af Stn Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Feb-2024 Corrigendum NIT Other 02-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work : REPAIR MAINT OF AC PLANTS, COOLING APPLIANCES AND OTHER CONNECTED MISC WORKS AT AF STN PATHANKOT
Sl. No. Item Description
1Comprehensive and preventive maintenance of the following Window, Split ACs, Water cooler, Refrigerator, Deep Freezer of different capacitiesby carrying out periodically maintenance of equipments including cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injection required for cleaning condenser/cooling coils complete and attending complaints all as specified and as directed by Engr-In-Charge Note: for items No 1 to 5.00(i) Window / Split ACs / Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis, (ii) Window/ Split Acs are to be maintained for heating as well as cooling mode all as specified and directed.A1 (iii) The contractor shall ensure and assesed at the site any initial maintenance required, to make the all Window/Split ACs/Water cooler / Refrigerator /Deep Freezer/Desert cooler in fully proper working condition. (iv) The date of periodical check will start from the date of commencement of work. (v) After completion of contract, contractor shall hand over the all " handed over Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler" in perfect running/functioning condition to the department. (vi)Contractor shall provide his authorised Cell/mobile No.and local address to contact and communicate the message for any break down and contractor"s rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to daycomplaints of any nature/type. (vii) Penalty for not rectifying the defect in time(within 24 hrs)will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (viii) Complaints will be treated as rectified only after user"s "Satisfactory slip "will be produced by contractor to concerned JE E/M. (ix) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made. (x) Old material obtained from spares replacedunder this item shall be contractor"s property and will be measured as per credit schedule. (xi) Cost of minor spares i.e, insulation to copper tubes, soldering, internal wiring to cooling appliances are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately, Refrigerant gas will only be measured when major items i.e, Comperessor, Condensing coil, Cooling coils are replaced, else cost of refrigerant gas required for less cooling, due to leakage etc will be deemed to be included in quoted rates. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor. (xii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates. (a) 1.5/2.0 Ton capacity Split AC.
2All as per ser item No 1.00 here-in-above for 1.5/2.0 Ton capacity window type AC complete all as specified and as directed by Engr-In-Charge.
3All as per ser item No 1.00 here-in-above for Water cooler ofany capacity complete all as specified and as directed by Engr-In-Charge.
4All as per ser item No 1.00 here-in-above forRefrigerator of any capacity complete all as specified and as directed by Engr-In-Charge.
5As per ser item No 1.00 here-in-above forDeep freezer of any capacity complete all as specified and as directed by Engr-In-Charge.
6Supply only following items to be fixed under Item No. 1 to 5 above:- Running capacitor of capacity 1.5 to 2.5 MFD as per existing sample and requirement complete all as specified and as directed by Engr-In-Charge.
7Supply only running capacitor of capacity 4 to 8 MFD as per existing sample and requirement complete all as specified and as directed by Engr-In-Charge.
8Supply only running capacitor of capacity 10 MFD as per existing sample and requirement complete all as specified and as directed by Engr-In-Charge.
9Supply only running capacitor of capacity 30 to 42 MFD as per existing sample and requirement. complete all as specified and as directed by Engr-In-Charge.
10Supply only running capacitor of capacity 45 to 60 MFD as per existing sample and requirement. complete all as specified and as directed by Engr-In-Charge.
11Supply only Starting capacitor, 40/60 MFD to 80/100 MFD as per existing sample and requirement. complete all as specified and as directed by Engr-In-Charge.
12Supply only Starting capacitor, 100/120 MFD to 120/150 MFD as per existing sample and requirement. complete all as specified and as directed by Engr-In-Charge.
13Supply only Thermostat switch for cooling appliances as per existing sample complete all as specified and as directed by Engr-In-Charge.
14Supply only Overload relay for cooling appliances as per existing sample complete all as specified and as directed by Engr-In-Charge.
15Supply only Starting relay for cooling appliances as per existing sample complete all as specified and as directed by Engr-In-Charge.
16Supply only Capillary tube special annealed double wound copper tubing as per existing sample complete all as specified and as directed by Engr-In-Charge.
17Supply only Copper tubing for cooling appliances of required size as per existing sample complete all as specified and as directed by Engr-In-Charge.
18Supply only Condensor Fan blade for cooling appliances of any size as per existing sample complete all as specified and as directed by Engr-In-Charge.
19Supply only Blower Fan blade for cooling appliances of any size as per existing sample complete all as specified and as directed by Engr-In-Charge.
20Supply only Blower Motor for cooling applinaces of any size as per existing sample complete all as specified and as directed by Engr-In-Charge.
21Supply only Condensor Motor for cooling appliances of any size as per existing sample complete all as specified and as directed by Engr-In-Charge.
22Supply only PCB card for refrigerator as per existing sample complete all as specified and as directed by Engr-In-Charge.
23Supply only PCB card for Air conditioner including remote as per existing sample complete all as specified and as directed by Engr-In-Charge.
24Supply only Push cock stainless steel as per existing sample for water cooler complete all as specified and as directed by Engr-In-Charge.
25Supply only Float valve as per existing sample complete all as specified and as directed by Engr-In-Charge.
26Supply only Plastic drain pipe for water cooler as per existing sample complete all as specified and as directed by Engr-In-Charge.
27Supply only Plastic drain pipe for Air conditioner as per existing sample complete all as specified and as directed by Engr-In-Charge.
28Supply only Swing motor for Air conditioner as perexisting sample complete all as specified and as directed by Engr-In-Charge.
29Supply only PVC connection as per existing sample complete all as specified and as directed by Engr-In-Charge.
30Supply only Display unit of Split/Window AC complete all as specified and as directed by Engr-In-Charge.
31Supply only Strainer/Filter for cooling appliances as per existing sample complete all as specified and as directed by Engr-In-Charge.
32Supply only Gasket, suitable for magnetic door of Refrigerator of any make and capacity and as per sample complete all as specified and as directed by Engr-In-Charge.
33Supply only Chilling tray, suitable for Refrigerator of any make and capacity as per existing sample complete all as specified and as directed by Engr-In-Charge.
34Supply only Vegetable tray, suitable for Refrigerator of any make and capacity as per existing sample complete all as specified and as directed by Engr-In-Charge.
35Supply only Freezer chamber for refrigerator of any make and capacity as per existing sample complete all as specified and as directed by Engr-In-Charge.
36Material and labour for replacement of condensing coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge.
37As per ser item No 36.00 here-in-above forWater cooler/refrigerator/deep freezer of any capacity complete all as specified and directed by Engr-in-Charge.
38Material and labour for replacement of cooling coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge.
39As per ser item No 38.00 here-in-above for refrigerator/water cooler/Deep freezer of any capacity as per sample complete all as specified and directed by Engr-In-Charge.
40Taking out of desert cooler from the site, de-assembling, cleaning of distribution pipe for proper water spray on pads, oiling and greasing the fan motor and tullu pump, checking of electrical circuit, fixing broken parts with the help of nutbolts, welding if required etc complete all as specified and directed by Engr-In-Charge.
41Material and labour for shifting of window/Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to Copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units if required including testing after shifting complete all as specifed and directed by Engr-In-Charge.
42Supply and fixing in Replacement of electrical lead from main connection3 core PVC insulated copper conductor of size 2.5 Sqmm in PVC conduit concealed/recessed as required at site complete all as specified and directed by Engr-In-Charge.
43As per ser item No 42.00 here-in-above forof size 4 sqmm complete all as specified and directed by Engr-In-Charge.
44Supply and filling of Gas R-22 for charging to window/Split Air conditioner/Deep freezer and water cooler to maintain adequate gas pressure complete all asspecified and directed by Engr-in-Charge.
45As per ser item No 44.00 here-in-above forgas R-407/410 complete all as specified and directed by Engr-In-Charge
46As per ser item No 44.00 here-in-above for gas R-134A complete all as specified and directed by Engr-In-Charge
47Material and labour for replacement of blower motor for Desert cooler as per sample complete all as specified and directed by Engr-In-Charge.
48Material and labour for replacement of blower fan blade suitable for Desert cooler as per sample complete all as specified and directed by Engr-In-Charge.
49Material and labour for replacement of submersible tullu pump suitable for desert cooler complete all as specified and directed by Engr-In-Charge.
50Supply and fixingin replacement indoor type unit of split type air conditioner 1.5 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
51Supply and fixing in replacement outdoor unit of split type air conditioner 1.5 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
52Supply and fixing in replacement indoor type unit of split type air conditioner 2.0 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
53Supply and fixing in replacement outdoor unit of split type air conditioner 2.0 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
54Material and labourfor replacement of rusted desert cooler body of desert cooler capacity upto 4000 cum/hr with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size matching with existingfabricated out of 20 gauge mild steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water, electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min 3 mtr in length). External surface shall be spray painted over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as per sampleand specified and directed by the Engr- in- Charge.
55Material and labourfor replacement of rusted louver suitable for desert cooler of capacity upto 4000 cum/hr as per sample complete all as specified and directed by Engr-In-Charge.
56Material and labourfor replacement of front grill including control panel prewired for desert cooler of capacity upto 4000 cum/hr as per sample complete all as specified and directed by Engr-In-Charge.
57Supply and fixing in replacement of wood wool pads different sizes as required with fixing accessories of superior quality /high density for desert cooler complete and all as specified and directed by Engr-In-Charge
58Supply and fixing in replacement front show grill of window AC 1.5 Ton capacity of any make as per sample complete all as specified and directed by Engr-In-Charge.
59Supply and fixing in replacement Metal clad Plug 2 pin and earth 20 Amps single phase complete all as specified and directed by Engr-In-Charge.
60As per ser item No 59.00 here-in-above forcapacity 32 Amps complete all as specified and directed by Engr-In-Charge.
61Supply and fixing in replacement Metal clad Socket for 2 pin and earth 20 Amps single phase complete all as specified and directed by Engr-In-Charge.
62As per ser item No 61.00 here-in-above for capacity 32 Amps complete all as specified and directed by Engr-In-Charge.
63Material and labour for providing locking arrangement in water cooler tank for provisioning of padlock including hinges, fixing clamp, welding/nut bolts/rivetting as required complete all as specified and directed by Engr-In-Charge.
64Supply and fixingin replacement water collector rack in water cooler for safe flow of unused water as per existing sample complete all as specified and directed by Engr-In-Charge.
65Material and labour for repair to broken gates of deep freezer/water cooler/Refrigerators by providing proper hinges at ends and to ensure complete compactness of the equipment to arrest cooling inside complete all as specified and directed by Engr-In-Charge.
66Material and labour for removing the old unserviceable hermatically sealed compressor unitfrom Water cooler of 40/80 &160/120 ltrs capacity and fixing new sealed unit reciprocating type hermatically sealed compressor unit as per sample including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.
67As per ser item No 66.00 here-in-above for1.5 TR split/window type AC complete all as specified and directed by Engr-In-Charge
68As per ser item No 66.00 here-in-above forr 2.0 TR split type AC complete all as specified and directed by Engr-In-Charge
69As per ser item No 66.00 here-in-above for upto 185 ltrs refrigerator complete all as specified and directed by Engr-In-Charge
70As per ser item No 66.00 here-in-above for refrigerator above 185 ltrs but upto 320 ltrs refrigerator complete all as specified and directed by Engr-In-Charge
71As per ser item No 66.00 here-in-above for Deep freezer of capacity above 185 ltrs upto 320 Ltrs complete all as specified and directed by Engr-In-Charge.
72Supply and fixing in replacement Plug Top 5 Amps, 230 volts AC complete all as specified and directed by Engr-In-Charge.
73As per ser item No 72.00 here-in-above for 15 Amps complete all as specified and directed by Engr-In-Charge.
74Supply & fixing in replacement of potential correction unit, with digital display and designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V within tolerance limit and suitable for AC of capacity 2.0 Ton not less than 5 KVA complete all as specified and directed by Engr-In-Charge.
75Supply and fixing Gate valve of size 15mm dia with ISI marked complete all as specified and directed by Engr-In-Charge.
76Repair to voltage stablizer by rewinding of transformer with suitable copper wire enamelled as existing gauge for stablizer 1.0 to 5 KVA including replacement of Voltmeter, selector switch, termination box etc as required complete all as specified and directed by Engr-In-Charge.
77Material and labour for servicing of central AC plant unit of any type and capacity upto 39 ton at site including, cleaning/descaling of cooling coil, insulation of suction and discharge line, oiling, greasing of blower motor, checking of electrical circuit supply and and replacement of defective filter, relay, capacitor over load protector etc as required, rewiring if necessary complete all as specified and directed by Engr-in-Charge. Note: Acid/Scale removal compound and required T&P should be provided by contractor without any extra cost. Note: Items to be replaced needs to be checked only for serviceability and will be measured and paid seperately under respective item of schedule
78Material and labourfor taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including reassembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed.
79Supply and fixing Filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr-In-Charge.
80Supply and fixing in replacement strip heaters 3.0 kilowatt suitable for mounting in AC Plant ducts or as required complete all as specified and directed
81Material and labour for replacement of PVC honey comb fins suitable for cooling Tower of capacity upto 3x39 TR complete as per sample all as specified and directed by Engr-in-Charge.
82Material and labourfor replacement of water distribution flaps of cooling tower of AC Plant capacity upto 3x39 TR as per sample complete all as specified and directed by Engr-In-Charge.
83Material and labourin replacement of air filter of AHU as per sample made of suiable filter with efficiency not less then 90% class 1 to 10 micron, matching with existing sample complete all as specified and directed by Engr-in-Charge.
84Material and labourfor cleaning of Cooling tower of any capacity by draining out water from inside, and including descaling of base tank and sprinkler including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
85Material and labourfor cleaning of base tank of Air cooling plant having blower motor of 15 HP capacity by draining out water from inside and including descaling of tank and water sprinklers including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
86Supply and changing/top up of compressor oil N-68 to AC Plant compressor upto adequate level complete all as specified and directed by Engr-in-Charge.
87Repair/servicing of air handling unit, cleaning of all duct from A.H.U.to supply air grill and cleaning/descaling of cooling coil, water pressure meter, greasing to bearings and taking out the dust and mud complete all as specified and directed by Engr-In-Charge
88Material and labourfor preparation of old surfaces for painting of existing Desert cooler/Water cooler/MS Pipes and applying two coats of synthetic enamelled paint of color matching with existing over one coat of primer red oxide complete all as specifed and directed by Engr-in-Charge.
89Supply and fixing in replacement water spray nozzles 32mm dia of Air cooling plant as per sample complete all as specified and directed by Engr-In-Charge
90Supply and fixing in replacement air grills/diffusers fabricated out of powder coated extruded aluminum sections including bird screen/VCD etc as per sample complete all as specified and directed by Engr-In-Charge.
91Supply and fixing in replacement of by pass safety valve for AC plant of capacity upto 39 TR as per sample complete all as specified and directed by Engr-In-Charge.
92Supply and fixing in replacement electrostatic scale preventor as per sample suitable for upto 390TR AC plant complete all as specified and directed.
93Supply and fixing in replacement water pressure gauge assembly complete with connection pipe to the existing pipe line complete withmatching with existing sample complete all as specified and directed by Engr-In-Charge.
94Supply and fixing in replacement temperature gauge assembly able to display temperature in degree and farheniet complete including connection to the existing pipe line matching with existing sample complete all as specified and directed by Engr-In-Charge.
95Supply and fixing in replacement HP/LP cutout complete all as specified and directed by Engr-In-Charge.
96Supply and fixing of thermostatic expansion valvesuitable for central AC plant of capacity 5.5 to 39 TR, complete and all as specified and directed by Engr-in-Charge.
97Material and labour for Replacement pilot control solenoid coil suitable for AC plant matching with existing sample complete all as specified and directed by Engr-in-Charge.
98Supply and fixing in replacement oil failure switch matching with existing sample complete and all as specified and directed by Engr-in-Charge.
99Supply and fix in replacement MCCB 63 Amps, 3/4 Pole, complete all as specified and directed by Engr-In-Charge.
100As per ser item No 99.00 here-in-above for capacity 100 Amps complete all as specified and directed by Engr-In-Charge.
101Supply and fixing in replacement MCB TPN, 63 Amps 415 volts complete all as specifeid and directed by Engr-In-Charge.
102Supply and fixing in replacement of Power contactor 63 Amps rating three pole, 415 volts complete all as specfied and directed by Engr-In-Charge.
103As per ser item No 102.00 here-in-above for40 Amps complete all as specified and directed.
104Supply and fixing in replacement V belt of any size matching with existing sample complete all as specified and directed by Engr-In-Charge
105Supply and fixing in replacement Controller circuit board for AC chiller of capacity 39 TR as per sample complete all as specified and directed by Engr-In-Charge
106Supply and fixing in replacement Controller circuit board for Package type AC plant of capacity upto 16.5 TR as per existing sample complete all as specified and directed by Engr-In-Charge.
107Supply and fixing in replacement of LCD display cum operating unit for package type AC plant of capacity upto 16.5 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed.
108Supply and fixing in replacement of LCD display cum operating unit for AC plant of capacity upto 39 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed.
109Supply and fixing in replacement hermatically sealed reciprocating type compressor unit of ac plant with capacity upto 16.5 TR of make and model as per sample complete all as specified and directed by Engr-In-Charge.
110Supply and fixing in replacement hermatically sealed reciprocating type compressor unit of ac plant with capacity upto 39 TR of make and model as per sample complete all as specified and directed by Engr-In-Charge.
111Supply and fixing in replacement thermal overload relay suitable for upto 7.5 HP three phase induction motor as per existing sample complete all as specified and directed by Engr-In-Charge.
112Supply and fixing in replacement ball bearing for blower motor for upto 40 HP motor capacityas per existing sample complete all as specified and directed by Engr-In-Charge.
113Supply and fixing in replacement heating element for hot water generator any capacity as per existing sample complete all as specified and directed by Engr-In-Charge.
114Replacement of unserviceable wiringfrom LT panel to motor of size 10 sqmm 3 core FRPVC insulated flexible copper conductor in PVC conduit and flexible conduit at termination end complete with fixing arrangements such as clamps and screws etc asspecified and directed by engr in-charge.
115Replacement of unserviceable wiringfrom LT panel to motor of size 6 sqmm FRPVC insulated flexible copper conductor in PVC conduit and flexible conduit at termination end complete with fixing arrangements such as clamps and screws etc asspecified and directed by engr in-charge.
116Material and labour for replacement of MS pipes 80 mm dia including all accessories or welding at site complete all as specified and directed by Engr-In-Charge
117Material and labour for replacement of GI pipes 15 mm dia including all accessories or welding at site complete all as specified and directed by Engr-In-Charge
118Supply and fixingGate valve of size 25mm dia with ISI marked complete all as specified and directed by Engr-In-Charge
119Supply and fixingGate valve of size 15mm dia with ISI marked complete all as specified and directed by Engr-In-Charge
120Supply and fixing in replacement gate valve suitable for 80mm dia MS Pipe complete all as specified and directed by Engr-In-Charge.
121Supply and fixing in replacement ofsingle phase preventer complete in all aspects matching with existing sample complete all as specified and directed by Engr-in-Charge.
122Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100mm bore all as specified and directed by engr in charge.
123Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 150mm bore all as specified and directed by engr in charge.
124Material and labour for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 100 MM bore all as specfied and as directed by engr in charge
125Material and labour for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 150 MM bore all as specfied and as directed by engr in charge
126Supply and fix butterfly valve of size 100 mm all as specified and as directed by engr in charge
127Supply and fix in replacement sheetmetal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps complete all as specified and directed by Engr-In-Charge.
128Supply, assembly and erection of GI sheet with C&SS rectangular/square duct made out of "L" shaped hollow profile, duly factory boxed incl all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 20 Gauge complete all as specified and directed by Engr-In-Charge.
129Servicing of dehumidifier by disconnecting the electrical connection, opening , cleaning the filters and duct checking electrical heaters, cleaning the fan/motor , servicing all other works required at site by authorised person of OEM complete all as specified and directed by Engr-In-Charge.
130Servicing of humidifier by replacement of transformer, rectifier and servicing as required andopening , cleaning the filters and duct, cleaning the fan/motor , servicing all other works required at site by authorised person of OEM complete all as specified and directed by Engr-In-Charge.
131Supply and fixing in replacement heater for dehumidifier as per sample required at site all as specified and directed by engr in charge.