| 1 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc complete complying with SS20B. TNDSS No:23&24 |
| 2 | Cement concrete of mix 1:4:8 (one part of cement four part of sand and eight part of aggregates) using 40 mm gauge machine broken granite stone jelly for foundation including de watering if found necessary and laid in layers of not more than 15 cm thick well rammed and consolidated etc complying with standard specification. |
| 3 | Supplying and erecting centering to sides and soffits including supports and strutting with necessary centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86. |
| 4 | Supplying, fabricating and placing in position of Steel Reinforcement using Mild steel or ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel cutting, bending, placing in position and binding with binding wire and all labour charges for cutting, bending, tying and placing in position etc, complete. TNDSS No:97 |
| 5 | Reinforcement Cement concrete 1:1½:3 (one part of cement one and a half part of sand and three part of aggregates) using machine broken granite jelly of 20 mm size for all reinforced cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. TNDSS No:30 |
| 6 | Cement concrete 1:2:4 (one part of cement two part of sand and four part of aggregates) using machine broken granite jelly of 20 mm size for all cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. |
| 7 | Brick work in cement mortar 1:5 (one part of cement five part of sand) mix using best country bricks of size 8¾\"x4¼\"x2¾\" from approved quarry including curing, cost and conveyance of all materials to site and all labour charges etc complete as per standard specification. |
| 8 | Plastering walls with cement mortar 1:4 (one part of cement four part of sand) 12 mm thick including all cost and conveyance of all materials and all labour charges etc. complete as per standard specification. TNDSS No:61 |
| 9 | Supplying and fixing of steel door with suitable design including cost of materials, welding and conveyance of all materials to site locking arrangements and painting one coat of primer etc. complete as per standard specifications including fixing charges etc. complete for the work. |
| 10 | Painting two coats with ready mixed plastic emulsion paints of first class quality and of approved colour over a priming coat including through scraping clean removal of dirt etc, complete and including cost of necessary plaster of paris, putty, brushes, wherever required and all labour charges, scaffolding charges etc., complete as per standard specification. |
| 11 | Supply and delivery of 12.5 HP submersible pump set having a duty condition of 600 lpm discharge against head of 75 metre confirming to IS specification with ISS marking suitable for installation panel board including cost of all materials and all conveyance charges etc complete as per standard specification. |
| 12 | Supply and delivery of wall mounting type control panel board of Ammeter, Voltmeter single phase prevents insulator-indicating lambs, STAR DELTA / DOL starter. Suitable for 12.5 HP suitable certificate pump set including all charges. |
| 13 | Labour charges for the erection of submersible pump set in bore well / open well including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. |
| 14 | Supply and delivery of flat type 4 sq mm PVC sheathed 3 core conductor cables conforming to IS 694 / 1990 with ISI marking suitable for submersible pump sets etc complete. |
| 15 | Wiring with 2 x 1.5 sq.mm (22/0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box in flush with wall with 5A F.T. switch, covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point for electronic regulator. (Assume 4 points/ coil) (SD-19) |
| 16 | Wiring with 2 x 1.5 Sq.mm (22/0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box and 5A F.T. switch with painting of suitable colour for open PVC light point / fan point for electronic regulator. (Assume 6 points per coil) (SD-20) |
| 17 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan 5 star rated complete ( Lower end) with 2 module 100W fan step regulator (Lower end) with 1 metre down rod on the existing fan clampSD 572 |
| 18 | Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4P MCB Isolator as incoming and 12 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. Lower End SD657 |
| 19 | Supply and run of 4 of 4 Sq.mm (56/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour SD 61. |
| 20 | Supplying, delivery and fixing in position of following PVC / GI pipes and specials of approved quality and good variety excluding fixing charges etc complete. |
| 21 | 65 mm GI pipe |
| 22 | 65 mm GI flange set |
| 23 | 65 mm GI hex nipple |
| 24 | 65 mm GI coupling |
| 25 | 65 mm non return valve |
| 26 | 65 mm GM gate valve |
| 27 | Paving floor with vitrified tiles (marbonite) in all floors over the base layer of cement mortar 1:3 (one par of cement three part of sand) 20 mm thick pointed with white cement at 0/40 kg/m2 including finishing the joints etc complete, as directed by the departmental officers (The rate should be exclusive of cost of flooring concrete 1:5) special. |
| 28 | Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam of required thick specification including premixing the materials with water at OMC in mechanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base / Base course on well prepared surface and compacting with vibratory roller to achieve the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause. 406 of MORTH Rev-5. |
| 29 | Supply of interlocking paver block M40 grade bounding and laying of 80 mm thick high strength type confirming IS 15658-2006 of interlocking paver block in regained size of minimum compressing strength type confirming IS 15658-2006 of interlocking paver block in regaining size of minimum compressive strength of 40N/mm² in uniform shape of approved non sticking make to be end in flushing bone pattern with approved non sticking surface in the top and the rate including gravelling the based preparation of subbase with and cushion 100 mm thick laying out the pavement and the pieces in fit edge. |