Maintenance Of Electronic Installation And Fans Ic Compound Lighting For Kalyanwas Delh Replacement, Design, Programing And Fabrication Of Centralized Water Pumping System, delhi-Delhi

Public Works Department-PWD has published Maintenance Of Electronic Installation And Fans Ic Compound Lighting For Kalyanwas Delh Replacement, Design, Programing And Fabrication Of Centralized Water Pumping System. Submission Date for this Tender is 16-02-2024. Water Pump Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42148730
Maintenance Of Electronic Installation And Fans Ic Compound Lighting For Kalyanwas Delh Replacement, Design, Programing And Fabrication Of Centralized Water Pumping System
Open Tender
Indian
Delhi
delhi
16-02-2024

Tender Details

Maintenance Of Electronic Installation And Fans Ic Compound Lighting For Kalyanwas Delh Replacement, Design, Programing And Fabrication Of Centralized Water Pumping System

Key Value

Document Fees
Refer document
EMD
INR 36798.0 /-
Tender Value
INR 18.39 Lakhs /-

BOQ Items

Name of Work:- MOEI & fans i/c compound lighting for Kalyanwas Delhi(SH:- Replacement, Design, Programing and fabrication of Centralized Water Pumping System)
Sl. No. Item Description
1Replacement of Cubical Panel accessories i/c connection, inter connection with aluminium thimbles, earthing with two nos. earth studs duly powder coated with approved colour complete etc. as reqd. Panel Accessories i) Energy Metre (Volt & Amp) - 8 Nos ii) Indicators- a) Red- 8 Nos, Green- 7 Nos, Blue- 1 No and Yellow-1 No iii) Push Buttons a) Red-7 Nos, Green-7 Nos iv) Isolators Switches 250 Amp 1 Pole-6 Nos Incoming i) 250 Amp. 36 KA MCCB 4 pole- 1 No. Outgoing-1 i) 100 Amp. 30 KA MCCB 4 pole - 3 No. ii) Contactors MNX-70 with Suitable rating 2 NO + 2 NC- 9 Nos iii) ML 12 overload relay (90 to 140 Amp) - 3 No iv) Current Transformers - 9 Nos v) Single Phase Preventor (VSP-2) – 3 No vi) Star Delta Timer – 3 No Outgoing-2 i) 63 Amp TPN - 3 No. ii) Contactors MNX-12 with Suitable rating 2 NO + 2 NC- 9 Nos iii) ML5 overload relay (24 to 40 Amp)- 3 No iv) Current Transformers - 9 Nos v) Single Phase Preventor (VSP-2) – 3 No vi) Star Delta Timer – 3 No
2Supplying Installation, Testing and Commissioning of suitable size Pressure/Flow Switch sensor with following specification ·Integrated temperature sensor ·IP65 compliant, Non-grease type ·Fluid temperature: 0 to 90°C ·GI/MS/PVC piping type: Applicable to deionized water, chemical liquids, etc. ·IO-Link compatible Same as per dia of inlet pipe connected to the main inlet water line for generating input command to automatic water pumping system by sensing strategic pressure and water flow etc. complete as required
3Supplying, Programing, Installation,Testing and Commissioning of 7 Inch IPS LCD Capacitive Touch Display for UI development Software from the OEM support for design UI Such as a button, slider, Graph, Text Display, RGB colour and 16.7M colours having 300 nit brightness for makes it visible in daylight etc complete as required Features 1. Built-in DGUS II intelligent software 2. Integrated smart screen 3. Powerful data management 4. Active Area (AA):154.1mm (W) ×85.9mm (H) 5. Operating Voltages:5V typical.(MIN:4.5V,MAX:5.5V) 6. Dimensions:190.5(W) × 105.4(H) × 13.4(T) capacitance touch screen, Buzzer 7. Capacitive touch panel, Built-in Buzzer, WIFI_10 module Display: 1. Size -7? 2. Display Format -1024*600 3. Brightness -3000nit 4. Active Area – 154.1mm (W) ×85.9mm (H) 5. Colour – 24-bit colour 8R8G8B 6. Backlight – LED Interface: • UART4:Mode is determined by Jumper:(be used after OS configuration) ON=N81/E81/O81/N82, 3.3V&5V TTL/COMS; OFF=N81/E81/O81/N82, RS232.
4Supplying Installation, Testing and Commissioning of water level sensor/Transmitter for measuring the water level of water collection tank and able to communicate and display the input on HMI interface having following technical parameters etc complete as required. Technical parameters a) Signal Line Specification: 2wire/3wire b) Zero Drift: ±0.02%FS/°C c) Thermal Sensitivity Shift: ±0.02%FS/°C d) Longterm Stability (1 Year): ±0.1%FS e) Frequency Response (-3dB): 3.2kHz f) Compensated Temperature: -20~+85°C g) Medium Temperature: -10~+85°C h) Overload Pressure: 200% FS i) Testing Range(m): 0.5-50
5Design, Programming, Fabrication,Installation, testing and commissioning of centralized water pumping controlling and monitoring system capable for controlling motors functionality automatic/manual mode and able to display motors functionality related measurement on HMI interface along with inbuilt printing option with thermal printers for managing the records. Centralized water pumping controlling and monitoring system panel specification a) Electrical Panel b) 36 DI , 24 DO Controller PLC c) 4 AI, 2 AO Analog Input Card d) Dual Port RS -485 Card Communication Card e) Multi-Function Energy Meter f) Current Transformer g) Real board for DI, DO isolation h) 10 Amp Power Supply for PLC and Control CKT i) Duct, Din rail, Wire, TB, Contactor , Fan, Filter ETC j) Indicator Lamp for Pump & Status Indicator Programing the automated panel for run the commands as per the actual parameters required to perform the automation and communicate with pressure/flow switch with along with level indictor sensor and different capacity motors to display the input parameters on HMI Interface. Similarly programing of HMI interface to communicate with sensor and PLC inputs and taken commands form touch enable feature for operating pump house on automatic/manual mode etc. complete as required