Tender For Achankovil Devaswom -Punalur Group: Installation Of 30 Kva Dg Set, Ssb Paneland Modernisation Of Meter Panel And At Achankovil Devaswom(Retender), Kollam-Kerala

Travancore Devaswom Board-TDB has published Tender For Achankovil Devaswom -Punalur Group: Installation Of 30 Kva Dg Set, Ssb Paneland Modernisation Of Meter Panel And At Achankovil Devaswom(Retender). Submission Date for this Tender is 16-02-2024. Diesel Generators Tenders in Kollam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

42145192
Tender For Achankovil Devaswom -Punalur Group: Installation Of 30 Kva Dg Set, Ssb Paneland Modernisation Of Meter Panel And At Achankovil Devaswom(Retender)
Open Tender
Indian
Kerala
Kollam
16-02-2024

Tender Details

Tender For Achankovil Devaswom -Punalur Group: Installation Of 30 Kva Dg Set, Ssb Paneland Modernisation Of Meter Panel And At Achankovil Devaswom ( Retender )

Key Value

Document Fees
INR 1900 /-
EMD
INR 23350.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Achankovil Devaswom -Punalur Group: Installation of 30 kVA DG set, SSB paneland modernisation of meter panel and at Achankovil Devaswom(RETENDER)
Sl. No. Item Description
1All materials having IS specification or approved quality should be used along the work.The work should be done as per the direction of the deapartment officials in site.
2Supply of 30 KVA ,24 KW A.C. Three Phase 415 V, 1500 RPM 0.8 power factor, 50 Hz, Silent Diesel Captive Generation Unit comprising of KIRLOSKAR iGREEN Engine Model 3R1040TG1 coupled directly to Alternator mounted on a rigid bed plate with suitable Acoustic Enclosure and complete with standard control panel, battery leads and fuel tank of suitable capacity etc
3Installation, testing , commissioning of the DG sets as per manufacturers recommendation and testing as per protocol. Rate to include all first fill HSD fuel. The rate to also includes unloading, handling at site, storing, and installation in correct assigned positions at Floor, effecting proper connections, testing & commissioning of DG SETS
4Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4 core 6 sq mm
54 core 10 sq mm
6Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp
74 core 6 sq mm with factory made clamp
84 core 10 sq mm with factory made clamp
9Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
10Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
11Supply and providing heavy duty "A" section neoprene gasket in the panel board U" section rubber beeding suitable for 1.60/ 2.00 mm sheet
12Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
13Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
14Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.75 mm copper conductor (6 SWG)
15Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip
16Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 4.00 mm (8 SWG)
17Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 35 sq. mm (32mm)
18Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
19Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP & N
2063 Amp TP & N
21100 Amp TP & N
22Providing and fixing following capacity On-Load Change Over Switches inside the existing panel board with lSI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100A 4 pole
23Supplying and fixing following Multifunction meter to read: V, A, F, 3 phase accuracy class 1 including drilling holes in cubicle panel, making connections, etc. as required.
24Supplying and fixing following Poilet lamp (Red,Yellow,Blue, Green & Orange colours LED indicator), AC/DC, 22.5 mm cut out dia mounted on CRCA sheet, Suitable rating SP MCB, “C” curve, 10 kA breaking capacity and single core copper conductor cable including drilling holes in cubicle panel, making connections, etc. as required.
25Supplying and fixing following rating, 100A, 2 Way neutral links mounted on DMC/SMC base including drilling holes in cubicle panel, making connections, etc. as required.
26Supplying and fixing following rating, 160A HRC Fuse Base with HRC Fuse link Unit including drilling holes in cubicle panel, making connections, etc. as required.
27Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required.2.5 cm, 4 cm, 5 cm height
28Supply and providing ISI marked 5 Kg dry chemical powder (ABC) fire extinguisher conforming to IS: 15683 along with hose and clamps including fixing it to wall as required.
29Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
30Fabrication supply and installation of dust vermin proof floor mounting thermoplastic meter box of following sizes suitable for fixing KSEB meter , fuse units ,CT etc hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment knock out for cable entry exit 600*300*214mm
31Civil Work- Construction of DG Shelter and foundation Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed: All Kinds of soil
32Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
33Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
34Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
35Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
36Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
37Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
38Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)
3912 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 ( 1 cement : 3 fine sand)
40Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
41Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
42Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail