Tender For Nursery Development Work Sutra Range Dabi, bundi-Rajasthan

Forest Department-FD has published Tender For Nursery Development Work Sutra Range Dabi. Submission Date for this Tender is 22-02-2024. Civil Work Tenders in bundi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42130419
Tender For Nursery Development Work Sutra Range Dabi
Open Tender
Indian
Rajasthan
bundi
22-02-2024

Tender Details

Tender For Nursery Development Work Sutra Range Dabi

Key Value

Document Fees
INR 200 /-
EMD
INR 10920.0 /-
Tender Value
INR 5.46 Lakhs /-

BOQ Items

Name of Work: Nursery devlopment work ,sutara Range Dabi , ,Bundi
Sl. No. Item Description
1WORK
2Excavation by meachanical means (Hydraulic Excavator ) manualmeansoverareas (exceeding 30 cm in depth 1.5m in widh as wellas 10sqm on plain) including disposal of excavated earth lead up to 50 m and lift up to 1.5 m disposed earth tobe levelled and neatly dressed ALL kinds of soil
3P/Lin position cements concrete including curing compaction etc complete in specified grade excluding the cost of centering & shuttering. All work up to plinth level ( I ) ()(II) Using1: 2 :4 stone agg 20mm nominal size(crusher broken )
4P/F steel gate grating and grill madeof angle tee square bar or other flat black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.70x70 mmx6 mm
5Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Itwo or more coats on new work
6Randam Rubble stone masonary with hard stone inFoundation and plinth in cement sand mortar above30 cm tick wall incement mortarl inc.m 1:6 ch 6 item no 6.1.6
7P& f .P.V.C storage Tank I,S,I marked (IS 12701) indicating the BIS license No) of approved make with cover, 25 mm dia 1m long Gi over flow pipe & 25 cmlong was out pipe with plug & socket, including making connection itc. Complete of approved design i-2000 litres,P.W.D itemno S-2.26.6 page no 236
8providing and fixing chlorinated polyviny chloride ( cpvc) pipe ( IS 15778:2007 code) having thermal stability for hot&cold water supply including all CPVC plain & brass threaded fitting, thise included jointing of pipes & fittings with one step CPVC solvent cement. trenching refilling& testing of joints complete as per direciion of Engineer in charge (External work) ch-S 2 item no2.39.4 page no240 P.WD B.S.R2022,(32 mm nominal dia )
9Plaster on new surface on wall in cement sand mortar1:4including racking of joints etc complete fine finish I ,25 mm thick
10Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked ( IS:9537 P - II ) rigid steel conduit & it"sISI marked (IS:14768 P-II 2003) accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal, 10A modularswitch, 3/5 pin 6 A modular socket, Modular faceplate with grid plate, pvc bushes, check nuts,screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR
11P & F 240/145 V Ac M.C,B with positive Isolation of breaking capacity not less than 10 K.A(B/C/D tripping charateristic) as per type of load and site required ) 4 kv impulse withstand volatage, ISI marked IS8828/ISI marked I.S 8828(1996) conforming to IEC 60898-1 2002, IEC 60947-2, low watt loosees, trip free mechanisum, energgy limitinh o class 3 asper IeC, minimum phase termination capacity of 35 sqmmm conductor line load reversibility,IP 20 contact protection and fitted in existing distribution board/sheets, mimnmum electrical operation 20000 upto 20A rating and 1,000 up to 63 A,5000 for 80A& above rating inluding making connections, testing etc as required oEM shall have submit NABL/CPRL/ERDA accrediated lab type test reports &ALL asper pre approved by Engineer in charge for addittional technical parametres of product/work refer Annexure " attached wiyh this B.S.R 1- Double pole M.C.B -6 A to 32A rating item no6.1.2.2 page17
12Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArmouredCoppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure "A" attached with this BSR 1-10mm dia meter submersible pump shall have following H.P Rateing,phase,head range,Discharge range respectively2.5 Sq. mm (3 core )
13SITC of raidal /mixed flow ISI marked water and anti corrosive liquid filled submersible motar pump set suitable for 100/150mm dia bore well,the size of adopter fixed on top of the motar should excerd thetop of coupler,for safe gaured thecoupler,the construction material of motar and pump should match IS.I marked ( I.S:8034-1:2018 andI.S9283 guideline the radial flow pump set should operate at 5 star energy efficiency level cEE and mixedflow pump set should operate at 3 star energy levelBee,accomped by valid BEE certifercticate motor should be IE2 class as per IEC 60034-2-1:2007,IEC60034-30:2008,& IS12615:2011 with required accessories including making connection of approved make with required accessories includingmaking connection suitablefor Bore wellthe job include labour part of lowering of riser pipe G.I/ ,GI/H.D.P.Epipe with ropeCables &pump, installation of complete fitting and accessories jointing of Electrical cables up to strater All labour ffor testingof submersible pump set and supply of installation of complete cables up to switch boardall Labour for testing of submersible pumps set and supply of water to watermains complete inAll respect,OEM shal have submit NABL/CPRI /ERDA accrediated lab testing certificate before exccution All asper pre approved by Engineer in charge for additional technical parametres of product/Work,refer Annexure " A" atteacth with this B.S.R i- 100mm dia meter submersible pump shall have following H.P Rating,phase, Head, minimum DDischarge respectively,3 H.P 1-Q(40-170) mtr,(60-20) LPScopper wound ch 21 item no21.6.1.4 page no 114