Tender For Restoration Of Electrical Connections To All Roadside Lights Approaching Towards Bolpur Sub C. Home., bolpur-West Bengal

Public Works Department-PWD has published Tender For Restoration Of Electrical Connections To All Roadside Lights Approaching Towards Bolpur Sub C. Home.. Submission Date for this Tender is 21-02-2024. Cutting Crimping and Punching Tools Tenders in bolpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42117074
Tender For Restoration Of Electrical Connections To All Roadside Lights Approaching Towards Bolpur Sub C. Home.
Open Tender
Indian
West Bengal
bolpur
21-02-2024

Tender Details

Tender For Restoration Of Electrical Connections To All Roadside Lights Approaching Towards Bolpur Sub C. Home.- 1 Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(a) 125 Amp on angle iron frame. (Make-L&T/Havells/ABB) 2 (b) 200 Amp on angle Iron frame.(Make-L&T/Siemens/ABB) 3 Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. 200/250 A. 4 Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wallas per GS ( Make - Legrand/L&T/Havells)8 Way ( Up to 160 A ) 5 Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs including necessary connection as per GS [ Make - Legrand/L&T/Havells) ].125 A FP 6 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/L&T/Siemens) ]i) 32A TP 7 ii) 63A TP 8 iii) 6-32 A SP 9 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way 10 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [D-5/6]100 Amp FP 11 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required.i) 2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug) 12 ii) 3 X 1.5 Sqmm 13 Supply of4 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / havells / Fort Gloster/KEI]i) 4 Core 70 Sq. mm 14 ii) 4 Core 16 Sq. mm 15 iii) 2 Core 10 Sq mm 16 Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. 17 Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. 18 Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.(i) 4 core 70 Sq mm . 19 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.(TATA-M/Bansal/Jindal)40 mm dia 20 Supplying and fixing compression type gland and finishing thoseforfollowing XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. i) 2 core 10 sq mm 21 ii) 4 Core 16 sq. mm 22 iii) 4 Core 70 Sq. mm 23 Dismantling of existing 8.5 Mt long pole from the from ground by demolishing the cement concrete. 24 Supply and delivery of9Mtr long swagged type steel tubular poles made of M.S. E.R.W pipes and manufactured as per IS 2713 (Part II) 1980 and IS : 1239 with the latest amendments. The designedspecificationof the pole will be as per 410 - SP -26 (92Kg) 25 Supply and delivery of8.5Mtr long swagged type steel tubular poles and its cross armbracket made of M.S. E.R.W pipes and manufactured as per IS 2713 (Part II) 1980 and IS : 1239 with the latest amendments. The designedspecificationof the pole will be as per 410 - SP -16 (75Kg) 26 Erection of Single Steel tubular pole of length as given below with sole plate & Cap etc. in CC foundation(Proportionand dimension indicated below), having 600x600x150 mm thickCC (4:2:1) base block below sole plate/pole with hard jhamametal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properl Upto 9.0 mtr. Size 0.6x0.6x1.70 mts 27 Supply of round bracket 1 Mtr. X 48 mm. dia of made of stainless steel designed for fixing at least 4 nos. of flood light fittings with required arrangement of sliding the fittings as per the requirement and need to be fixed on the top of the erected poles alongwith s&f of necessary materials. [NS] 28 S&F of 240 volt, 100 W LED street light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make NEXUS cat no LSTP-100-CDLM/Havells/Philips] 29 S&F of 240 volt, 135 W LED flood light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make PLUTO NEO cat no LFLN-135-CDL/60 M/Havells/Philips] 30 S&F of 240 volt, 70 W LED flood light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make PROFILE+ NEO cat no LFL-70-CDL/60 HP M/Havells/Philips] 31 S&F of 240 volt, 36 W LED street light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make ASTRA NEO cat no LSTS-36-CDL M/Havells/Philips] 32 Supplying & fixing 40 mm dia x 1.2 metre long (incl. L type bends) GI pipe vertical type service bracket on wall for carrying 3 wires and an earth wire complete with Galv. MS clamps forfixing on wall with necessary screw incl. painting, as per direction of EIC 33 Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixedpaint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long polei) One coat of red lead/Zinc chromate priming. 34 ii) 1st coat of synthetic enamel paint over the primer. 35 iii) 2nd coat of synthetic enamel paint over the 1st coat. 36 Painting Block Letters or Digits within a circle/square as required, with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below Size 40mm and upto 50 mm 37 Supply and fixing of (250 X 200X 105)mm polycarbonet loop box(Make- Sintex) fixed on existing pole by 2 nos GI Band and Screw,nut and bolts, which contais 16 Amp porceline fuse,1 nos 4 way terminal making all connection complete with proper locking arrangemant and mending good the damages. 38 S & F of suitablesize three phase timer box on wall with locking arrangement & DIN Rail consisting of following items incl. necy. inter connection by suitable size of stranded PVC insulated 1.1 kV Gr.Cu wire after crimping as per direction of EIC (A) Double door (2+10) way SPNDB with IP 42/43 protection (Make:Crabtree/Siemens/ABB/Hager) - 1 No.(B) Digital timer having provision of adjustment 24 hour (Make:L&T/GIC/GE/Legrand/ABB/Hagger) - 1 No.(C) 240 V,50 HZ magnetic coilwith TP 45A power contactor having 2 NO & 2 NC Contact (Make : L&T (MNX-45) /Siemens/Havells/Legrand/ABB/Hager)- 1 No(D)415 V 40A 10kA,DIN mounted FP MCB C curve (Make : Legrand/Siemens/ L&T/ Schneider/ABB /Hager) -1 No (E) One no.red,yellow,Blue and one no.green 240V LED indicator for indicating Auto & bypass indication(Make : L&T/Kaycee/ABB) - 1 Set(F) Toggle Switch - 1 Set (G) Locking arrangement and two way malamine terminal - 1 No. 39 Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil 40 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS 41 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection toequipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No 6 SWG. 42 SITC of LED Type Arc shaped Glow sign board fabricated by 16x5x10 depth ACP box supported with suitable size MS angle iron of 18 swg. All around. The 3 mm Aludecor (exterior) finished ACO facial should be provided 3d with Laser cutting 6 mm laser cut Acrylic letters/ steel letter (as per direction of EIC) out of which 5 mm rising and border line of the front side shold with cover 1 Alluminium channel as per the direction of EIC.incl. S & F 3 in size LED-3525 (Samsung Korean Module make, cat no.-LED-3525) as required on LED panels, IP-67,Type: Double line fixed, Intesity: Same & Smooth through out, no bright or light or dark patches, [16x5=80 sqft]80 Sq ft X 2 Nos=160 Sq ftVisibility:easy to seen in day-light also 10 Mtr at least for normal eye, Ambient Air: 0-50 degree centigrade, 100% relative humidity, Power consumption--1.2 watt/Module, minimum 60,000 burning Hrs, water proofing and fixing the LED boards with black backelite light bar with super bright, easy to seen in day-light, incl S&F of required power supply unit having Input:90~240 VAC 50 Hz Output : 12 VDC forced cooling system ( Make: MeanWell) complete with all accessories with providing necessary interconnection with 2x2.5 sqmm for Ph & N and 1x1.5 sqmm as ECC PVC insulated FRLS copper wireand S & F 25 mm x 25 mm Aluminium angle of 4 mm thick fixed with machine screw of all sides of facia and fixing the Glow Sign Board. Back side of the board should be covered with 26 swg GI sheet to protect from ingress of rain water.The sign board should be fixed at the 3nons 600 mm long 10 x 10 PCC Piller by using 1mtr long 50mm x 50mm x 6mm angle iron with nut, bolt, washers and 3nons triangle back side support by 3mtr long 50mm x 50mm x 6mm angle iron with 3nos 600 mm long 10 x 10 PCC Piller with nut, bolt, washers etc.including sufficient iron structure for gate side Glowsign board with 50mm x 50mm x 6 mm iron angle and painting also as directed by EIC and drawing approved by EIC and mending good the damages as per direction of EIC. Inscription of the sign board should be as per direction of authority and as per direction of EIC.The Lettering are of white color/ steel colour and logo as per directed by Authority. Letteringand Style as directed by Authority/As per choice of EIC.

Key Value

Document Fees
Refer document
EMD
INR 20528.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Restoration of Electrical Connections to all roadside lights approaching towards Bolpur Sub C. Home.
Sl. No. Item Description
1Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (a) 125 Amp on angle iron frame. (Make-L&T/Havells/ABB)
2(b) 200 Amp on angle Iron frame.(Make-L&T/Siemens/ABB)
3Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. 200/250 A.
4Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wallas per GS ( Make - Legrand/L&T/Havells) 8 Way ( Up to 160 A )
5Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs including necessary connection as per GS [ Make - Legrand/L&T/Havells) ]. 125 A FP
6Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/L&T/Siemens) ] i) 32A TP
7ii) 63A TP
8iii) 6-32 A SP
9Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way
10Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [D-5/6] 100 Amp FP
11Distribution wiring in 1.1 KV single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required. i) 2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug)
12ii) 3 X 1.5 Sqmm
13Supply of4 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / havells / Fort Gloster/KEI] i) 4 Core 70 Sq. mm
14ii) 4 Core 16 Sq. mm
15iii) 2 Core 10 Sq mm
16Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
17Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
18Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. (i) 4 core 70 Sq mm .
19Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.(TATA-M/Bansal/Jindal) 40 mm dia
20Supplying and fixing compression type gland and finishing thoseforfollowing XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. i) 2 core 10 sq mm
21ii) 4 Core 16 sq. mm
22iii) 4 Core 70 Sq. mm
23Dismantling of existing 8.5 Mt long pole from the from ground by demolishing the cement concrete.
24Supply and delivery of9Mtr long swagged type steel tubular poles made of M.S. E.R.W pipes and manufactured as per IS 2713 (Part II) 1980 and IS : 1239 with the latest amendments. The designedspecificationof the pole will be as per 410 - SP -26 (92Kg)
25Supply and delivery of8.5Mtr long swagged type steel tubular poles and its cross armbracket made of M.S. E.R.W pipes and manufactured as per IS 2713 (Part II) 1980 and IS : 1239 with the latest amendments. The designedspecificationof the pole will be as per 410 - SP -16 (75Kg)
26Erection of Single Steel tubular pole of length as given below with sole plate & Cap etc. in CC foundation(Proportionand dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhamametal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properl Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
27Supply of round bracket 1 Mtr. X 48 mm. dia of made of stainless steel designed for fixing at least 4 nos. of flood light fittings with required arrangement of sliding the fittings as per the requirement and need to be fixed on the top of the erected poles alongwith s&f of necessary materials. [NS]
28S&F of 240 volt, 100 W LED street light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make NEXUS cat no LSTP-100-CDLM/Havells/Philips]
29S&F of 240 volt, 135 W LED flood light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make PLUTO NEO cat no LFLN-135-CDL/60 M/Havells/Philips]
30S&F of 240 volt, 70 W LED flood light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make PROFILE+ NEO cat no LFL-70-CDL/60 HP M/Havells/Philips]
31S&F of 240 volt, 36 W LED street light luminaire (System Efficacy-110 lumen per watt) IP 66 on existng arm bracket with necessary connection. [ CROMPTON GREAVES make ASTRA NEO cat no LSTS-36-CDL M/Havells/Philips]
32Supplying & fixing 40 mm dia x 1.2 metre long (incl. L type bends) GI pipe vertical type service bracket on wall for carrying 3 wires and an earth wire complete with Galv. MS clamps forfixing on wall with necessary screw incl. painting, as per direction of EIC
33Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixedpaint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole i) One coat of red lead/Zinc chromate priming.
34ii) 1st coat of synthetic enamel paint over the primer.
35iii) 2nd coat of synthetic enamel paint over the 1st coat.
36Painting Block Letters or Digits within a circle/square as required, with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below Size 40mm and upto 50 mm
37Supply and fixing of (250 X 200X 105)mm polycarbonet loop box(Make- Sintex) fixed on existing pole by 2 nos GI Band and Screw,nut and bolts, which contais 16 Amp porceline fuse,1 nos 4 way terminal making all connection complete with proper locking arrangemant and mending good the damages.
38S & F of suitablesize three phase timer box on wall with locking arrangement & DIN Rail consisting of following items incl. necy. inter connection by suitable size of stranded PVC insulated 1.1 kV Gr.Cu wire after crimping as per direction of EIC (A) Double door (2+10) way SPNDB with IP 42/43 protection (Make:Crabtree/Siemens/ABB/Hager) - 1 No. (B) Digital timer having provision of adjustment 24 hour (Make:L&T/GIC/GE/Legrand/ABB/Hagger) - 1 No. (C) 240 V,50 HZ magnetic coilwith TP 45A power contactor having 2 NO & 2 NC Contact (Make : L&T (MNX-45) /Siemens/Havells/Legrand/ABB/Hager)- 1 No (D)415 V 40A 10kA,DIN mounted FP MCB "C" curve (Make : Legrand/Siemens/ L&T/ Schneider/ABB /Hager) -1 No (E) One no.red,yellow,Blue and one no.green 240V LED indicator for indicating Auto & bypass indication(Make : L&T/Kaycee/ABB) - 1 Set (F) Toggle Switch - 1 Set (G) Locking arrangement and two way malamine terminal - 1 No.
39Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil
40Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS
41Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No 6 SWG.
42SITC of LED Type Arc shaped Glow sign board fabricated by 16"x5"x10" depth ACP box supported with suitable size MS angle iron of 18 swg. All around. The 3 mm Aludecor (exterior) finished ACO facial should be provided 3d with Laser cutting 6 mm laser cut Acrylic letters/ steel letter (as per direction of EIC) out of which 5 mm rising and border line of the front side shold with cover 1" Alluminium channel as per the direction of EIC.incl. S & F 3 in size LED-3525 (Samsung Korean Module make, cat no.-LED-3525) as required on LED panels, IP-67,Type: Double line fixed, Intesity: Same & Smooth through out, no bright or light or dark patches, [16"x5"=80 sqft]80 Sq ft X 2 Nos=160 Sq ft Visibility:easy to seen in day-light also 10 Mtr at least for normal eye, Ambient Air: 0-50 degree centigrade, 100% relative humidity, Power consumption--1.2 watt/Module, minimum 60,000 burning Hrs, water proofing and fixing the LED boards with black backelite light bar with super bright, easy to seen in day-light, incl S&F of required power supply unit having Input:90~240 VAC 50 Hz Output : 12 VDC forced cooling system ( Make: MeanWell) complete with all accessories with providing necessary interconnection with 2x2.5 sqmm for Ph & N and 1x1.5 sqmm as ECC PVC insulated FRLS copper wireand S & F 25 mm x 25 mm Aluminium angle of 4 mm thick fixed with machine screw of all sides of facia and fixing the Glow Sign Board. Back side of the board should be covered with 26 swg GI sheet to protect from ingress of rain water. The sign board should be fixed at the 3nons 600 mm long 10"" x 10"" PCC Piller by using 1mtr long 50mm x 50mm x 6mm angle iron with nut, bolt, washers and 3nons triangle back side support by 3mtr long 50mm x 50mm x 6mm angle iron with 3nos 600 mm long 10"" x 10"" PCC Piller with nut, bolt, washers etc.including sufficient iron structure for gate side Glowsign board with 50mm x 50mm x 6 mm iron angle and painting also as directed by EIC and drawing approved by EIC and mending good the damages as per direction of EIC. Inscription of the sign board should be as per direction of authority and as per direction of EIC.The Lettering are of white color/ steel colour and logo as per directed by Authority. Letteringand Style as directed by Authority/As per choice of EIC.