}

Tender For Supply , Installation, Testing, Commissioning Of Medical Gas Pipe Line System At 50 Bedded Field Ward At District Hospital Pali, District Pali, pali-Rajasthan

Medical And Health Services -MAHS has published Tender For Supply , Installation, Testing, Commissioning Of Medical Gas Pipe Line System At 50 Bedded Field Ward At District Hospital Pali, District Pali. Submission Date for this Tender is 22-02-2024. Medical Gas System Tenders in pali Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42107667
Tender For Supply , Installation, Testing, Commissioning Of Medical Gas Pipe Line System At 50 Bedded Field Ward At District Hospital Pali, District Pali
Open Tender
Indian
Rajasthan
pali
22-02-2024

Tender Details

Tender For Supply , Installation, Testing, Commissioning Of Medical Gas Pipe Line System At 50 Bedded Field Ward At District Hospital Pali, District Pali

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work: SITC of Medical Gas Pipe Line System at 50 Beded Field Ward at District Hospital Pali, District Pali
Sl. No. Item Description
1SITC of MGPS of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased (ie free from oil, grease and partivulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipecutter and copper pipe fitting"s shal comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-1 2016.
2SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat havng quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20"C to 130"C. Valve should be CE approved / CE certified. For 12 MM OD pipe
3For 15 MM OD pipe
4For 22 MM OD pipe
5SITC of Gas outlet points (AR-4), (AR-7) and vacumm (8.7 psig) for dispensing medical gases (oxygen/air/vaccum) at point of use confirming to BSEN ISO 9170-1: 2008. The Gas outlet are quick connect for different gas source and should accept only respective adapters as required.
6SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body double jacketed with flow gradations marked on it. Desired flow will be setteled through roatary knob. Flow range should be between 0 to 15 Ipm & work should be executed as per direction of engineer n charge.
7SITC of suction unit (suction controller and collection jar) with posibility to configure required capacity capacity collection jar and should meets the requirements as per BSEN ISO 10079-3:2009 the unit must designed to operate with the vacucum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature - 18"C to 50"C with ON/OFF facility. The collection jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121"C for 20 minutes for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level, the complete unit supplied with filter to protect the source and pipe line from bacterial contamination. 600 ml Capacity collection Jar
8SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for sxygen and vaccum line and should comply with ENISO5211:2001 complete with ball type valves and gauses as required for oxygen compressed air and vaccum line (three gas) For Two Gas
9SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning it should monitors the current status of oxygen/ compressed air pressure in distrubuton pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-1:2007. For Two Gas Services
10SITC High Pressure Tube For Oxygen /Vacuum Work Should Be Execute As Per Direction
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail