| 1 | Attending day to day complaints of no electric supply in light circuit or power circuit or any other circuit due to burning/loose/disconnecting of any wire i.e. neutral/ phase/ half, loose connection at switch, socket, MCB and tripping of MCB complete including diagnosing, rectification of fault, any petty repair required to restore the electric supply for checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires upto 1 Mtr length etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws in switches, sockets, switch board, ceiling fans/ exhaust fans etc., required to make the circuit functional during 0900 Hrs to 1700 Hrs by deploying electrician alongwith helper including necessary tools complete all as specified and directed.Notes:-(a) Repairs/ faults in any one quarter upto 8 points/ one occupancy shall be considered as one complaint (one measuring unit) even if repair is involved in more than one light point or fitting.(b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed electrician & helper will carry all T&P, functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor. (e) Contractor shall be responsible for collection of all ON LINE, off line/ telephonic complaints and handing over the same to JE E/M after rectification duly signed by user with details of stores fixed to put the status ON LINE after attending/ complete of the job on the same day.(f) Fixing & Replacement of electric fittings/ fixtures MBsreplaced shall be measured separately under relevant items of Sch. |
| 2 | Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, one way including taking down old unserviceable complete all as specified |
| 3 | Supply and fixing in repairs bell push switch flush type 5 Amps, SP, 240 volts including taking down existing bell complete all as specified |
| 4 | Supply and fixing in repairs socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, flush type including taking down existing socket complete all as specified |
| 5 | Supply and fixing in repairs socket out let 5 Amp, 3 pin flush type including taking down existing socket complete all as specified. |
| 6 | Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified. |
| 7 | Supply and fixing in repairs switch piano flush type, 15 Amps, 240 Volt AC single pole, one way including taking down existing complete all as specified. |
| 8 | Supply and fixing in repairs bell electric AC (Ding Dong) 240 volt SP including taking down existing bell complete all as specified |
| 9 | Supply and fixing in repairs lamp holder insulated body with back plate (white colour) suitable for batten fittings including taking down existing lamp holder complete all as specified. |
| 10 | Supply and fixing in repairs fan step regulator, electronic type, single phase, (socket type) including connection complete after dismantling/ removing unserviceable regulator all as specified. |
| 11 | Supply and fixing in replacement ceiling rose surface type bakelite 65 x 50mm three terminal including taking down complete all as specified and directed. |
| 12 | Supply and fixing in replacement FRLS PVCinsulated unsheathedmulti stranded copper conductor of size 1.5 Sqmm single core (colour as reqd at site) complete drawing through existing conduit to use for tapping circuit/ replacement of half/ neutral/ earth including taking down existing wire any type all as specified. |
| 13 | Supply and fixing in replacement FRLS PVCinsulated unsheathedmulti stranded copper conductor of size 2.5 Sqmm single core (colour as reqd at site) complete drawing through existing conduit to use for tapping circuit/ replacement of half/ neutral/ earth including taking down existing wire any type all as specified. |
| 14 | Supply and fixing in replacement FRLS PVCinsulated unsheathedmulti stranded copper conductor of size 4 Sqmm single core (colour as reqd at site) complete drawing through existing conduit to use for tapping circuit/sub main/ replacement of half/ neutral/ earth including taking down existing wire any type all as specified. |
| 15 | Supply and fixing in repair energy saving bulk head luminaries with opal diffuse LED 9 watt 6000 K power factor more than 0.90 with high efficiency LED electronic driver, surge protection upto 2 KV, 240V 50 Hz complete prewired connection and testing complete all as specified |
| 16 | Material and labour for replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6 Sqmm drawn through in and including PVC rigid non metallic concealed conduit(medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm PVC insulated with green insulation with any type of civil work involved complete all as specified. Note : Two run of 6 sqmm wire and one run of 6 sqmm wireas earth wire includingPVC conduit shall be measured as one unit. |
| 17 | Material and labour for replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of4 Sqmm drawn throughnew PVC rigid non metallic conduit(medium grade ISI marked) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm PVC insulated with green insulation complete all as specified.Note : Two run of 4 sqmm wire and one run of 4 sqmm wireas earth wire includingPVC conduit shall be measured as one unit |
| 18 | Supply and fixing in replacement for sheet metal DB for MCBs, SPN, 8 ways, double door, single phase, with bus bar, neutral bar/ connectors suitable copper thimbles, lugs etc complete all as specified.Make: EKINOX3 series of Legrand/Acti 9 metalic series of Schneider/ Optipro of Indoasian/ Osafe of HPL/ Metallica of Havells/ Hager/ L&T/ Siemens/SSK |
| 19 | Supply and fixing in repair TPN double doorDB 4 way with earth Bus Bars, Neutral Links, blanking plates confirming to Osafe series of HPL/ Acti 9 series of Schneider/ Optipro of Indoasian or equivalent in Havells/ Hager/ L&T/ Siemens/SSK complete all as specified and directed by Engineer-in-Charge |
| 20 | Supply and fixingin repairTPNMCB 40 Amps, 10 KAas per Osafe series of HPL/ Acti 9 series of Schneider/ SIEMENS/ABB/Havells/SSK complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply and fixing in repair MCB SP 6 to 32 Amps, 10 KA, B curve as per Osafe series of HPL/Acti 9 series of Schneider/Dx3 range of Legrand/ Betagard 5 SL range of Siemens/STADx range of Havells/ Optipro of Indoasian complete all as specified and directed |
| 22 | Supply and fixing in replacement MCB SPN 25 to 40 Amps, 10 KA, B curve240V,as per Osafe series of HPL/Acti 9 series of Schneider/Dx3 range of Legrand/ Betagard 5 SL range of Siemens/STADx range of Havells/ Optipro of Indoasian/ SSK complete all as specified and directed |
| 23 | Supply and fixingin replacement Deco ultra slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 20 WLED batten, minimum lumen efficacy 100 lumen/watt,cool white, 240V 50 Hz complete all as specified and directed by Engineer-in-Charge |
| 24 | Supply and fixing in repair box type frame suitable for fixing of T8 LED tube light 18 watt min or next higher wattage single side/ double side connection as required at site (suitable of item ser No 25.00) all as specified and directed by Engineer-in-Charge |
| 25 | Supply and fixing in repair LED tube rod 18W or next higher wattage polycarbonate T8 within built driver, retrofitting type single side/ double side connection as required at site with heat sink having high efficacy more than 120 lumen/ watt min complete all as specified and directed by Engineer-in-Charge. Note : Make of item Sr No 24.00& 25.00 shall be same. |
| 26 | Supply and fixingin replacement Deco ultra slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 18 WLED batten, minimum lumen efficacy 100 lumen/watt,cool white, 240V 50 Hz complete all as specified and directed by Engineer-in-Charge |
| 27 | Supply and fixingin replacement Deco ultra slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack9W LED complete all as specified and directed by Engineer-in-Charge |
| 28 | Material and labour for VTPN/ Loadline DB 6 way, 415 volts double door complete with bus bar, neutral link, earth link complete with MCCB 4 way, 125 Amp complete all as specified and directed |
| 29 | Supply and fixing LED building security light 25 watt or next high wattage having energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass/ polycarbonate cover and suitable optics for uniform distribution of light 25 watt LED for building security lights with high efficiency electronic driver BIS approved, having IP-66 protection,surge protection operative on AC supply 140 volts to 270 volts pre-wired complete with GI pipe of 20/ 25mm bore bracket and MS clamp duly painted with two coat paint all as specified and directed |
| 30 | Supply and fixing in repair city 1 new decorative wall light fixture made up of polycarbonate, suitable for lamp type 1 x 9 watt retrofit LED lamp including 9 watt LED lamp as fitting complete all as specified. |
| 31 | Supply and fixing in replacement plastic laminated bakelite sheet top cover 3mm thick make hylum of size 9 x 11 inches or equivalent fixed with nickel polished screws with washers including making hole as per site requirement including taking out complete all as specified and directed |
| 32 | All as per srl item No. 31.00 here-in-before but 5 x 5 inches |
| 33 | All as per srl item No. 31.00 here-in-before but 8 x 5 inches |
| 34 | Supply and fixing in replacement MCCB FP 63 Amp, 415V with fixedthermalmagnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed |
| 35 | Supply and fixing in replacement MCCB FP 125 Amp, 415V with fixed thermal magnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed |
| 36 | Supply and fixing in repair Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one SP MCB 25 Amps all as specified & directed by Engineer-in-Charge |
| 37 | Supply and fixing in replacement white modular switch 1 way 6 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed. |
| 38 | Supply and fixing in replacement white modular switch 1 way 16 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed. |
| 39 | Supply and fixing in replacement fan step regulator, 120W, 2 module including taking down complete all as specified and directed. |
| 40 | Supply and fixing in replacement modular socket, 6A, 2/3 pin combined 2 module including taking down complete all as specified and directed. |
| 41 | Supply and fixing in replacement modular socket, 6A/16A, 2/3 pin combined 2 module including taking down complete all as specified and directed. |
| 42 | Supply & fixingin replacement Mini modular MCB SP 32 Amps B- curve all as specified and directed. |
| 43 | Supply and fixing blanking strips (dummy) 1/2 module for modular switch board complete all as specified |
| 44 | Supply and fixing in repair PVC casing capping 20 mm width min or next higher size (ISI marked) all as specified and directed by Engineer-in-Charge |
| 45 | Attending complaints of not working/ abnormal noise of fans/ exhaust fan due to loose connection of any wire i.e. neutral/ phase not working of circuits or un-serviceability of any item such as capacitor, rubber real, wire etc rectification of fault including any sort of petty repair required to make the fans functional during 0900 Hrs to 1800 Hrs by deploying electrician with helpers including necessary tools complete all as specified. |
| 46 | Supply and fixing in repairs condenser 2.50 MFD including taking down existing complete all as specified. |
| 47 | Supply and fixing in repairs condenser 3.15 MFD including taking down existing complete all as specified. |
| 48 | Supply and fixing in repairs rubber reel for ceiling fan including nut & bolt including taking down existing rubber real complete all as specified. |
| 49 | Supply and fixing in repairsflexible wire twisted twin core of size 0.75 Sqmm copper conductor cable connected from fan block to 0.60 M long (Provn for ceiling fan & exhaust fan ceiling rose) complete all as specified and as directed |
| 50 | Material and labour for replacement of sheet steel made sunken box concealed type od size 8 x 10 inch including opening bakelite sheet, removing old sunken box and fixing new complete with necessary civil work including repair to match existing surface complete including refixing bakelite sheet complete all as specified and directed |
| 51 | All as per srl item No. 50.00 here-in-before but 4 x 7 inches |
| 52 | All as per srl item No. 50.00 here-in-before but 4 x 4 inches |
| 53 | Material and labour for replacement of LED lamp 12 watt, B-22 base in sketch fittings/ holder complete all as specified and directedNote for Srl item No 2.00 to 53.00 : Contractor will get make and sample approval of items required to be replaced mentioned at Srl No 2.00 to 53.00 and will hand over after placing work order to JE-in-charge with all PV & TC to ensure availability when required during currency of contract and these items/ material will be issued by JE E/M daily in complaint cell on actual assessment of complaints to replace the defective part and for accounting of items. The contractor will maintain register regarding details of daily complaints received, pending, rectified, items replaced on daily basis duly signed by contractor, JE etc. (ii) The item Sr No shall be executed on daily basis for attending complaints. Hence, contractor shall quote his rate accordingly.(ii) Old retrieved material shall be deposited to JE E/M in AGE E/M yard/ E/M wksp on same day and will be given to contractor only at the time of RAR after necessary recovery under Sch of credit. |
| 54 | Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc includingremoving switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable lightand for taking credit of unserviceable light as per Sch of creditand making good disturbed surface of walls, roof, floors etc. with any type of civil work involved complete all as specified and directed |
| 55 | Material and labour for point wiring for light/ fan point with 1.5 Sqmm (nominal area) FRLS PVCinsulated unsheathedmulti stranded copper conductor of size 1.5 Sqmm cabledrawn in and including concealed rigid PVC conduit medium grade (ISI marked) not less than 20mm dia with accessories and terminated in and including sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cupwashers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimbleincluding cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification complete all as specified and as directed by Engineer-in-Charge |
| 56 | All as per srl item No. 55.00 here-in-before but for one bell point controlled by one bell push complete all as specified. |
| 57 | All as per srl item No. 55.00 here-in-before but for one socket outlet 5 Amps on independent board complete all as specified. |
| 58 | All as per srl item No. 55.00 here-in-before but for one socket outlet 5 Amps on the sameboard complete all as specified. |
| 59 | All as per srl item No. 55 here-in-before but with 2.5 Sqmm(nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathedFRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 60 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground levelconnected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and including GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wire mesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, saltall as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthingpoint with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner. |
| 61 | Material and labour for louvers suitable for exhaust fan 230mm sweep complete made of suitable powder coated frame square type of 16 gauge thickness min with flappers of aluminium complete all as specified and directed |
| 62 | Material and labour for louvers suitable for exhaust fan 300mm sweep complete made of suitable powder coated frame square type of 16 gauge thickness min with flappers of aluminium complete all as specified and directed. |
| 63 | Material and labour for inner tank suitable for storage type water heater tank 25 Ltrs complete including opening, dismantling water heater and replacement of inner water tank, fixing of insulation and assembling complete all as specified and directed |
| 64 | Material and labour for outer tank suitable for storage type water heater tank 25 Ltrs complete including opening, dismantling water heater and replacement of outer water tank, fixing of insulation and assembling complete all as specified and directed |
| 65 | Refixing of existing serviceable tube lights including necessary connections complete all as specified and directed |
| 66 | Supply and fixing in repair exhaust fan, steel body AC single Phase 230V of size 300m sweep with, blades, and frame and louvers completeincluding cutting of hole in wall and making good to disturbed surface all as specified and directed |