Tender For Repair / Replacement Of Summer Appliances At Af Stn Adampur, adampur-Punjab

Military Engineer Services-MES has published Tender For Repair / Replacement Of Summer Appliances At Af Stn Adampur. Submission Date for this Tender is 28-02-2024. Air Conditioner Tenders in adampur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42092428
Corrigendum : Tender For Repair / Replacement Of Summer Appliances At Af Stn Adampur
Open Tender
Indian
Punjab
adampur
28-02-2024

Tender Details

Repair / Replacement Of Summer Appliances At Af Stn Adampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 59800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair / Replacement of summer appliances at AF Stn Adampur
Sl. No. Item Description
1Window type air 1.5 Ton capacity conditioner including soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner IN REPLACEMENT etc with testing etc complete.
2Split type air capacity conditioner including soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner IN REPLACEMENT etc with testing etc complete of following capacity:-
31.5 Ton
42 Ton
5NOTE FOR SERIAL ITEM NO 1 TO 2.02 (i)Unserviceable sealed compressor may be given with more than one cut (ii)Unit rate include transportation to site of work & back as applicable (iii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor. (iv)Make of new items to be replaced shall be approved by GE
6Re-winding of blower motor of window type AC 1.5 Ton capacity any make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including REPLACEMENT GM bushes / bearing, fixing and testing on load with testing etc complete.
7Re-winding of blower motor of Split type ACany make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including REPLACEMENT GM bushes/bearing, fixing and testing on load etc complete of following capacity:-
81.5 Ton
92 Ton
10Running capacitor 50+6 mfdIN REPLACEMENT complete.
11Starting relay for air conditioner IN REPLACEMENT,complete for following:-
121.5 Ton window type
131.5 Ton Split Type
14Thermostatic switches for any capacity for window/split type AC, IN REPLACEMENT etc complete.
15Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for window type room air conditioner 1.5 Ton capacity of existing make and size, IN REPLACEMENT complete.
16Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for split type room air conditioner 1.5 Ton capacity of existing make and size, IN REPLACEMENT complete for following:-
17Out door unit split type AC
18Indoor unit split type AC
19Maintenance, servicing cleaning ofat site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condenser motor, blower/condensor fan rectification of fault, connecting and testing on load completefor following:-
20Window type room air conditioner 1.5 / 2 Ton capacity
21Split type room air conditioner 1.5 / 2 Ton capacity
22NOTE:- Replacement of spares or gas shall be measured and paid separately under respective item of BoQ
23Grill of window type room air conditioner 1.5 ton capacity suitable for any make & model as existing at site, IN REPLACEMENT complete.
24Supply only Methyle-acetylene and propadience gas (flame gas) cylinder of weight 400 gm complete.
25Cutting, disconnecting & taking out the condensing unit of window type room air conditioner 1.5 Ton capacity and replacement with new condensing unit of appropriate size and model including welding brazing etc and testing on load complete.
26Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5 Ton capacity and providing the new evaporator of existing size model in place including welding, brazing etc and testing on load complete.
27Spray painting of window type AC 1.5 Ton capacity including preparation of old surfaces and applying one coat of synthetic enamel paint (colour as per original shade ) including writing of SM No over the body with white/black paint complete.
28Air filter, IN REPLACEMENT complete for following capacity :-
29Window type AC 1.5 Ton
30Split type AC 1.5 Ton
31Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Metallic) complete with one single pole MCB for 240 volt 20 Amp rating rupturing capacity 10 kA complete fixed IN REPAIRS complete.
32Shifting of existing Air Conditionersfrom one palce to another place, any height/any floor as per requirnment of users any make and new re-installation and commissioning the unit including testing ofter gas charging complete for following:-
33Window AC of 1.5 ton capacity
34Split AC of 1.5 ton capacity
35Copper Pipe including welding brazing of copper pipe, IN REPLACEMENT,complete. For following size:-
365/8"( with sleeves)
371/4"( with sleeves)
381/2"( with sleeves)
393/8"( with sleeves)
40Blower assembly for window type AC any capacity, IN REPLACEMENT,complete
41Condenser fan suitable capacity, IN REPLACEMENT,complete for following:-
42Window type AC
43Split type AC
44Top Plug3 pin 220 Volt 15 Amp, IN REPLACEMENTcomplete.
45Blowerfor indoor unit, IN REPLACEMENTfor following capacity:-
46Split type AC 1.5 Ton
47Split type AC 2 Ton
48Remote kit (PCP plate), IN REPLACEMENT for following capacity:-
49Split type AC 1.5/2 Ton
50Window type AC 1.5/2 Ton
51Repair of remote kit (PCP plate) for window type/split type Acof any capacitycomplete.
52WATER COOLER :- Water cooler storage type U/S Sealed unit compressor ofanymake & model and supply and fixing compressor of same make for water coolercapacitysoldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load etc complete of following size:-
53Capacity 40/80 litre
54Capacity 120/150 litre
55NOTE FOR SERIAL ITEM NO 26.01 TO 26.02:- (i)Unserviceable sealed compressor may be given with more than one cut (ii)Unit rate include transportation to site of work & back as applicable (iii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor. (iv)Make of new items to be replaced shall be approved by GE
56Re-winding of blower motor of water cooler any capacity any make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including REPLACEMENT GM bushes/ bearing, fixing and testing on load complete.
57Running capacitor 10 mfd for water cooler IN REPLACEMENT complete.
58Thermostatic switches for any capacity for Water cooler IN REPLACEMENT complete.
59Starting relay for Water Cooler IN REPLACEMENT complete.
60Hose pipe 20 mm dia synthetic PVC rubber corrugated of standard length for water cooler complete with two clamps (worm gear type) one on each side IN REPLACEMENT, complete.
6120 mm dia PVC pipe cotton braded for water cooler connection, IN REPLACEMENT complete
6220 mm dia MS clamp (worm gear type) for PVC pipe IN REPLACEMENT complete
63Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for Water Cooler of existing make and size IN REPLACEMENT, complete
64Self closing taps of cast iron galvanised, chromium plated screwed for iron pipe suitable for water coolers IN REPLACEMENT complete
65Maintenance & servicing of water cooler 40/80 ltrs & 100/150 Ltrs at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condenser motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis, connecting & testing on load for performance complete. Note:Spare and gas shall be measured and paid separately.
66Spray painting to water cooler 40/80 Litre & 120/150 Litre with one coat of synthetic enamel paint (colour as per original shade) including writing of SM No over the body with white/black paint Complete.
67Cutting, disconnecting & taking out the condensing unit of Water Cooler capacity and providing the new evaporator of existing size model in place including welding, brazing etc and testing on load complete.
68Floatvalves high pressure of PTMT with epoxy coated aluminum rod and high- density plastic ball screwed for iron pipe dixed 15mm dia minimum weight 210 gms etc IN REPLACEMENT complete all as specified
69Gun metal globe/gate valve, 15mm with iron wheel head, ISI marked (IS:9890), screwed both ends for GI tubes, IN REPLACEMENT, complete all as specified
70PVC connections 15 mm size of length 600 mm with PTMT nutsIN REPLACEMENT,complete all as specified.
71GI nipple 15 mm dia 150 mm long fixedIN REPAIR complete.
72REFRIGERATOR :- Unserviceable sealed unit compressor of Refrigerator anymake & model and supply and fixing company New compressor of same make for Refrigerator soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load etc complete entire satisfation of Engineer-in-charge for following size:-
73Upto 175 litrecapacity
74Above 175 litre capacity
75NOTE FOR SERIAL ITEM NO 43.01 TO 43.02:- (i)Unserviceable sealed compressor may be given with more than one cut. (ii)Unit rate include transportation to site of work & back as applicable. (iii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor. (iv)Make of new items to be replaced shall be approved by GE.
76Thermostatic switches for any capacity for Refrigerator IN REPLACEMENT, complete
77Starting relay for Refrigerator IN REPLACEMENT, complete
78Maintenance, servicing & repair of refrigerator 165/175 litres capacity any make model cleaning the various components and replacementi. e Chill tray, Shelves, Freezer door, Door Gasket,Door Lock,Blub Holder & bulb and Food tray complete for following size :-
79165/175 litres capacity
80230/310 ltrs capacity
81Spare part of domestic refrigerator IN REPLACEMENT all as sample complete for following :-
82Defrost timer
83Bimetal relay
84Defrost heater
85Fan motor assy along with fan blade
86over load protection for refrigerator
87PTC relay
88Condenser line filter for Refrigerator, IN REPLACEMENT,complete
89Refrigeration gas(Mefron/Refron) in returnable cylinder for following :-
90F-22/R-22
91R-134
92DESERT COOLER :- Re-winding of blower motor of desert cooler any capacity any make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, fixing and testing on load etc complete.
93Running capacitor 4 mfdIN REPLACEMENT complete.
9415 mm dia PVC (heavy duty) pipe for desert cooler, IN REPLACEMENT complete.
95Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for Desert Cooler of existing make and size, IN REPLACEMENT complete.
96Blower fan blade complete for desert cooler, IN REPLACEMENT complete.
97PVC insulated & sheathed stranded FRLS copper conductor three core cable 1100 Volts of size 1 sq. mm ( nominal area), IN REPLACEMENT complete all as specified.
98Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparations surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling the pump & motor (a)Wiper (b)Plastic impeller of tullu pump with enclosure (c)Distributor complete.
99Pump motor 1/26 HP (Tullu pump) 230 volts, single phase, 1440 RPM for desert cooler IN REPLACEMENT, complete.
100Wood wool pad set suitable for desert cooler heavy duty IN REPLACEMENT, complete.
101GI Socket 15 mm dia fixed IN REPAIR, complete.
102Starting capacitor 4 mfd forDesert Cooler IN REPLACEMENT, complete.
103Selector switch combination of 4 switches(for low,med,high & pump on/off) for desert Cooler as per sample, IN REPAIR complete.
104Top Plug3 pin 220 Volt 5 Amp, IN REPLACEMENTcomplete.
105VOLTAGE STABLIZER :- Automatic voltage stabilizer single phase 50 Hz complete with time delay relay and auto cut off in the event of low/high voltage and all as per the following parameters fixed IN REPLACEMENT:- (i)Incoming voltage 140 V to 200 V (ii)Stabilized voltage 230 +- 5% complete for following size:-
1063 KVA capacity
1075 KVA capacity
108Re-winding of main transformer of voltage stabilizer with super enamelled copper winding wire of suitable gauge including making connection by soldering and testing etc complete of following size:-
1093 KVA capacity
1105 KVA capacity
111Relay for voltage stabilizer 240 volts all as per sample and required at site IN REPLACEMENT, complete.
112Volt meter 0-300 volts, fixedIN REPAIR, complete.
113Amps meter 0-30 Amp, fixed IN REPAIR, complete.
114Timer circuit for voltage stabilizer IN REPLACEMENT all as per sample and required at site complete.
115Connector porcelain type for voltage stabilizer IN REPLACEMENT, complete.
116Drain hose pipe of length 05 metre for Air Conditioners/Water Coolers, IN REPLACEMENT complete.
117Metal clad socket with two Pin and earth & plug top with one MCB SP 240 volt 20 Amp, IN REPLACEMENT complete.
118Providing services for attending all types of day to day complaints in respect of all make, work & type of cooling appliances i.e., Air Conditioners (window type, split type, cassette type and ductable type) , water coolers , desert coolers and voltage stabilizers installed at various locations by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp meter, brazing rod, butane gas cylinder, tape roll, vacuum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, &other instruments which are required for maintenance, repair and to make the equipment functionalThe complaints record to be maintained on the complaint register & complaint slips all as directed.
119NOTE FOR SERIAL ITEM No.-72:- (i) Cost of spares including refrigerent for charging and rewinding /replacement of condensor fan motors, compressor, blower fan etc if required shall be measured and paid seperately under respective item (ii) In case of multiple complaints to be attended on daily basis, the contractor will be liable to deploy adequate resources and manpower to address the complaints in specified time frame failing which a recovery of Rs 200/- per complaint per day will be affected from the due payments of the contractor. Quoted rate shall be deemed to include this aspect.
120NOTE:- Not withstanding with the provision of "Compensation for Delay" envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation@ Rs. 500/- day will be charged from contractor in case he fails to make the functional to the entire satisfaction of Engineer-in-Charge within 48 hour of receiving of complaint from the MES regarding non working above items.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail