Tender For Finishing And Associated Works In Plant Water Pump House At Frfcf Project Site, Kalpakkam, kalpakkam-Tamil Nadu

Bhabha Atomic Research Centre-BARC has published Tender For Finishing And Associated Works In Plant Water Pump House At Frfcf Project Site, Kalpakkam. Submission Date for this Tender is 22-02-2024. Water Pump Tenders in kalpakkam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42088806
Tender For Finishing And Associated Works In Plant Water Pump House At Frfcf Project Site, Kalpakkam
Open Tender
Indian
Tamil Nadu
kalpakkam
22-02-2024

Tender Details

Finishing And Associated Works In Plant Water Pump House At Frfcf Project Site, Kalpakkam

Key Value

Document Fees
Refer document
EMD
INR 509726.0 /-
Tender Value
INR 2.54 Crore /-

BOQ Items

Name of Work : Finishing and Associated works in Plant water pump house at FRFCF project site, Kalpakkam
Sl. No. Item Description
1Earthwork excavation by mechanical means (Hydraulic excavator) or manual means for foundation, substructures, plinth beam, cess pits & trenches, all kinds of foundation etc.,in all types of soil like hard gravelly soil, sandy soil for the followingdepth from average ground level upto the required founding level, line and grades in both dry and wet conditions including shoring, strutting, bailing out of water if necessary, levelling, ramming and achieving 95% modified proctor density at the bottom of trenches, dressing of sides, stacking the excavated materials away from the edge of trenches, refilling the sides of foundation as required with selected excavated earth and depositing / disposing the surplus excavated earth (Disposed soil to be leveled by breaking clods, if any and neatly dressed and leveled) within the lead specified below all complete as per specifications and as directed by the Engineer-in-charge.(if water encountered during excavation , it shall be drained out by proper dewatering arrangements and power supply required for dewatering shall borne by the contractor.) Note: 1. Proper compaction shall be carried out at the founding level with a suitable roller of adequate capacity. 2. Refilling shall be done in layers of not more than 300mm (loose).
2All kinds of soil with depth up to 1.5m below average Ground level and disposing surplus excavated earth up to a lead of 1Km
3All kinds of soil with depth exceeding 1.5m but not exceeding 3m below average Ground level and disposing surplus excavated earth up to a lead of 1Km
4Engineered back fillingwith selected earth including excavation from borrow pits with a lead upto 60 km filling in layer of not more than 300 mm, each layer well rammed and consolidated including water consolidation etc complying with standard specification. Note : 1) Necessary permission from state authorities for bringing the required earth will be the responsibility of the contractor. 2) The quality of earth required for the work shall be got approved for borrow pits outside the property within a lead upto 60 km from EIC before supply. 3) Necessary Testing to be carried out for compaction and as directed by the Engineer all as per specification, including excavation, loading transporting, depositing in loose layers of each 300 mm thickness, after removing / breaking clods etc. watering to optimum moisture content and compacting each layer to 95 % of maximum dry density etc., all as specified and as directed by the EIC.
5Supply, fixing and laying bi-axial geo-grids of tensile stength minimum 20kN/m, stiching as per specification at junction, Leveling and laying at site as per drawing and direction by Engineer-in-charge. The required testing for qualification will be carried out by the contractor at his cost. (Payment will be made as per actual measurement at site, laps will also be measured for payment)
6Dewatering from trenches, sump, foundation structure using electrical submersible or suitable pump of required capasity with necessary arrangements to the nearest storm water drain or at places shown as directed by EIC including HDPE pipe, maintenance of the system, cost of spares, idling, labour for operation etc. Mode of measeurement will be power consumption in KWh. Note: This item will be operated during abnormal bad weather, surface run off from outside scope of work only.
7Supplying & placing Filcrete using cement crushed stone sand in proportion of 1:15 at temperature not exceeding 38 deg C for filling at all elevation inclusive of all labour, batching, mixing, transportation, material, compaction, pumping, curing etc all complete as per specification, drawing and as directed by the Engineer In-charge.
8Supplying and injecting with approved quality chemical emulsion at the rates and concentrations as per IS 6313-2001 Part II for preconstructional anti termite treatment and creating a chemical barir under and alrond the masonry pits, masonry foundations, wall trenches, plinth filling, junctions of wall and floor, expansion joints, surfaces of RCC works for a depth of min. 500mm from the finished ground level, surrounding of pipes, conduits etc., walls retaining soil above floor level, apron and drain along the perimetr of the building including all byeworks complete as per specification/IS 6313:2001 and direction of Engineer-in-charge. Only ground floor plinth area of the building will be measured for the payment in the following three stages. i) 20% after completeion of the foundations i) 50% after completion of the ground floor flooring iii) 30% after completion of all treatment works including ground floor doors & windows. Work ot be executed by M/s Pest Control (India) or any other approved agency and specified guarantee for 6 (six) years shall be furnished b the tenderer. Payment will be cleared only after submission of Guarantee.
9Construction of granular sub-base by providing coarse graded Material, spreading in uniform layers with motor grader on prepared surface, mixing in a mix place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete in all respects as per clause 401 of MoRT&H specifications for road and bridge works (4th Revision) and as directed by the Engineer-in-charge.
10for Grading-I material
11Providing and laying plain cement concrete M20 grade using 300 kg/cum of PPC, 20mm maximum size graded aggregates and washed crushed stone sand including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification for levelling courses in foundation for walls, footings, floor drains etc., encasing pipes and other required works directed by Engineer-in-Charge complete all as per specifications. Dosage of PCE based admixture as per workability requirment at site conditions. Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Polycarboxylate ether (PCE) based chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility. 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/ downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F.
12Providing and laying plain cement concrete M20 grade using 300 kg/cum of PPC, 20mm maximum size graded aggregates and washed washed crushed stone sand including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification up to a height of0 to 15m for levelling courses inscreed concrete at terrace level, encasing pipes and other required works directed by Engineer-in-Charge complete all as per specifications. Dosage of PCE based admixture as per workability requirment at site conditions. Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Polycarboxylate ether (PCE) based chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/ downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F.
13Providing and laying cast insitu controlled reinforced cement concrete of specified grade at all levels and lifts mentioned below using20mm maximum size hard granite machine washed crushed graded stone aggregates and washed crushed stone sand including testings as per QAP, weigh batching, charges for mixing & cost of admixture, mechanical mixing, transporting and placing at all lifts, vibrating, consolidating, 14 days curing and finishing smooth of all exposed faces complete for column footing, columns, lintels, sunshades, gutter slabs, beams, slabs, water tank, machine foundation and all other structural elements including dewatering wherever necessary (Formwork and reinforcement will be paid for separately) all as per specification and all as shown in drawings and as directed by the Engineer-in-charge for all insitu item. Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Polycarboxylate ether (PCE) based chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility. 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/ downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F.
14M30 grade with 380 kg of PPC per cu.m. of concrete upto plinth level
15M30 grade with 380 kg of PPC per cu.m. of concrete for all floors
16Manufacturing, supplying, hoisting and fixing in position at all lifts, precast units of various patterns and sizes for precast plain solid units, slabs, etc, in controlled reinforced cement concrete of M30 grade using 20mm andbelowmachine crushed graded stone aggregate including making perforations in precast slab as per drawing weigh batching, mechanical mixing, casting, vibrating, finishing of exposed faces, curing, necessary formwork, moulds, transporting and placing at all lifts,preparation of connections, grouting with cement mortar/cement grout wherever neededexcluding steel reinforcement complete all as per drawing,specification and as directed by Engineer. Note:1. The rate shall be quoted on the basis of using 380 Kg. of PPC Cement per cu.m. of concrete.Any upward/downward variation required to obtain the specified strength will be paid for or deducted at the rate specified in schedule F. 2. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture.Chemical admixture confirming to IS:9103 shall be mixed in fresh concrete and prior permission from Engineer-in-charge shall be obtained for dosage and compatibility. 3. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor.
17Providing straightening, decoiling wherever necessary bending, cutting, binding and fixing in position steel reinforcement TMT bars of Fe500D grade steel conforming to IS:1786 and tying with approved annealed binding wire of 1.6mm dia in all reinforced cement concrete work at all lifts, including cost of supplying and fixing the spacer/cover blocks and binding wire complete all as per specification and as directed by Engineer-in-Charge at all lifts. Note: The rate shall be including the cost and testing of reinforcement steel at thrid party NABL lab. The reinforcement steel will be procured from dealers with a test certificate as approved by the department. For further details please see Clause 11 of Section VIII, General Information for Guidance of Tenderers.
18Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering to correct line and levels for transom & mullions including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. The measurement for the formwork will be the actual area of forms in contact with concrete surfaces. Shuttering with plywood panels alone will be permitted.
19Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like MS structural embedment"s/pipe and sleeves/penetration etc.Using MS angles, channels, I-sections, plates, tees, flats, rounds, MS/CS pipes,square sections etc. including chamfering and rounding off the edges, applying a coat of Red lead paint primer / Zinc chromate primer of approved make and 2 coats of flat oil paint / sythetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge. Note: Lifting device arrangements if any required also arranged by the contractor at his own cost.
20Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like chequered plates including chamfering and rounding off the edges, applying a coat of Red lead paint primer / Zinc chromate primer of approved make and 2 coats of flat oil paint / sythetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge. Note: Lifting device arrangements if any required also arranged by the contractor at his own cost.
21Supplying, fabricating, installing, placing and securing in position steel grills for windows comprising of square bars / MS flats as per detailed drawing including cutting, bending to shape, welding painting with two coats of synthetic enamel paint of approved colour over one coat of primer complete all as per specification and drawings.
22Providing, fabricating and fixing hand rail using SS304 grade Stainless Steel pipes, Square sections, plates etc. of approved size and make and quality by cutting to required size, welding, mirror / mat polishing, fixing at site etc. for balcony railing & staircases railing including special sections as per drawings, speciifications complete. A sample to be fabricated and to be got approved by the Engineer-in-charge before starting of work at site.This work to be exceuted through approved specialized agency.
23Supplying, providing and laying 200mm thick Cement Concrete block masonry using solid concrete blocks of size 400 x 200 x 100mm manufactured as per IS : 2185 (Part-1) density not less than 1800 kg/cu.m of grade C 4.0 using 20mm down graded aggregates in basement & superstructure at all elevations in cement mortar 1:5including mixing mortar, hacking closely concrete surface, laying blocks, raking joints, curing etc.,with all materials, scaffolding, labour, tools etc., all complete as per drawings, specifications and as directed by the Engineer-in-charge. Reinforcement if provided will be measured and paid under relevant item.
24Providing and constructing 100mm thick precast concrete solid blocks masonry wall in cement mortar 1:4 with solid concrete blocks of size 400x200x100mm Grade C (4.0), manufactured as per IS : 2185 (Part-1): 2005 density not less than 1800Kg/cum. at all Elevation including cost of materials, labour charges, scaffolding, curing complete all as per specifications and as directed by the Engineer-in-charge.
25Providing and laying Integral cement based treatment using rough Kota stone for water proofing on horizontal surfaces at all depth below ground level for under ground structures including testing for leak-proof ness with guarantee bond for a period 10 years etc. complete as directed by Engineer-in-charge and consisting of 1) 1st layer of 20 mm thick approved rough kota stone slab of size 600 x 600 mm over a 25 mm thick base of CM 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately).Joints sealed and grouted with cement slurry mixed with water proofing compound. 2) 2nd layer of 25 mm thick CM 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. 3) Finishing top with stone aggregate of 6 to 10 mm nominal size spreading at closer spacing embedded in the 2nd layer.
26Providing and laying Integral cement based treatment for water proofing on vertical surfaces by fixing specified stone slab 20 mm thick rough Kota stone with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with CM 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofingcompound in recommended proportion complete at all levels including testing for leak-proof ness with guarantee bond for a period 10 years etc. complete and as directed by Engineer-in-charge. Supplying, Installing and securing in position during the concreting, fusing butt joint welding and testing the joints and fixing in position PVC water stops in all insitu-concrete works including cost of material, labour and all operations at all levels etc.,as per specifications and as directed by Engineer In-charge.
27Surface Ribbed type 230 mm wide 5 mm thick
28Providing plastering to the internal surfaces of brickwork / concrete at all elevations in cement mortar 1:5, 12mm thick including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications.
29Providing and applying minimum 20 mm thick external Sand faced cement sand plaster in two coats, first coat to be 12 mm thick cement sand mortar 1:4 (1 cement : 4 fine sand) including mixing approved pure acrylic based polymer modified cementations water proofing compound in the proportion recommended by the manufacturer in both the layers, keeping the surface of the base coat rough to receive sand faced treatment. Second coat to be 8 mm thick in cement sand mortar 1:3 (1 cement : 3 fine sand), finishingthe surface, bytaking out grains or keeping the surface rough to receive finishing work or as required to receive specified architectural external finish, to correct line, plumb and level to external faces of walls, soffits/ceiling if any, independent double legged scaffolding, plastering precast concrete, window sills, RCC cornices, makingwattas, drip moulds, pattas etc, curing, cleaning, at all levels, complete all as directed by EIC.
30Providing Rough cast plastering 20mm thick at all elevations and levels consisting of 8mm thick rough cast in cement mortar 1:3 using 6mm to 10mm size hard granite stone, over a bed of 12mm thick cement mortar 1:5 for external faces, including scaffolding, curing, providing grooves wherever required complete all as per specification & drawings and as directed by Engineer-in-charge.
31Providing plastering in cement mortar 1:4, 20mm, thick at all elevations with 2% of water proofing compound or as per manufactures specification, "lmpermo" or approved equivalent make including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, all as per specifications.
32Providing F3 finish over concrete surface in cement mortar 1:1.5 (1 part cement : 1.5 part fine sand) including wetting the surface, labours, curing, all materials, scaffolding, at all elevations complete all as per specification and as directed by the Engineer-in-charge.
33Providing and fixing chicken-mesh reinforcement of 1.5mm dia steel wire with hexagonal or rectangular openings of 10 to 13mm, fixing using nails, including cutting of required sizes complete all as per specification and as directed by the Engineer-in-charge.
34Providing and fixing in position 25mm thick High Density Thermocole having minimum density of 20 kg/cum in expansion joint gap filling, machine foundation,including cutting to required sizes, wrapping with 500 micron thick polyethylene sheet, etc complete all as per specifications and as directed by EIC.
35Supplying, mixing and caulking areas at and around penetrations, Embedded Parts, construction joints, expansion joints and at all locationsas specified in the drawings, using approved Bitumastic compound joint sealant including preparation of surfaces and edges, applying appropriate primer, backstop, Tape, masking tapes, supply of necessary tools, equipment, scaffolding, manpower etc. all complete as per specifications drawings and as directed by the EIC.
36Providing and laying 50 mm thick cement concrete flooring with Metallic concrete hardener topping consisting of under layer 38 mm thick using N30 grade concrete with graded stone aggregate 20 mm size and top layer 12 mm thick cement hardener consisting of mix 1:2(1 cement + ironite hardener mix : 2 graded stone aggregate6 mm nominal size) by volume,in which 1 part ironite hardening compound is mixed to 4 part cement by weight or as per manufacturers specifications, including providing & fixing glass dividing strip of 40x3 mm wherever required, necessary compaction, filling joints, neat cement finish, curing, cleaning the base etc. complete all as directed by the EIC
37Supplying and laying approved quality Polished Vitrified floor tiles of size(600mmx600mm or 300x300 size) 9 to 10mm thick Kajaria/ Asian/ Nitco or approved equivalent conforming to IS 15622 first quality in pattern / combination as shown in drawing,over 40mm thick bed of cement mortar 1:4, to achieve total final floor finish of 50mm thickness, jointed with neat cement slurry mixd with pigment to match the shade of tiles including all materials, labour, tool etc., complete all as per schedule drawings / specification and as directed by EIC. Note: Sample shall be submitted and got approved by EIC before procurement.
38Supplying and laying approved quality Anti-Skid Vitrified floor tiles of size(600mmx600mm or 300x300 size) 9 to 10mm thick Kajaria/ Asian/ Nitco or approved equivalent conforming to IS 15622 first quality in pattern / combination as shown in drawing,over 40mm thick bed of cement mortar 1:4, to achieve total final floor finish of 50mm thickness, jointed with neat cement slurry mixd with pigment to match the shade of tiles including all materials, labour, tool etc., complete all as per schedule drawings / specification and as directed by EIC. Note: Sample shall be submitted and got approved by EIC before procurement.
39Providing and laying 50mm thick Indian patent stone flooring and skirting with cement concrete 1:2:4, using 10mm and below size hard broken granite stone jelly including dividing strips, laying in panels, consolidating, curing, rubbing the surface smooth, cleaning the surface neatly at the time of handing over the area complete all as per specifications and as directed by the Engineer.
40Providing and applying painting Two coats at all levels with Interior grade Acrylic emulsion paint (approved brand, colour and manufacturer) confirming to IS 5411 Part I & II at all elevation to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces, grinding, removing laitance, cement slurry, formoil, foreign matter etc., scaffolding, tools, tackles, equipment, materials, labour, etc.., all complete as per manufacturer specifications and as directed by the Engineer-in-charge. Note: Rate includes filling all voids/pinholes in concrete by cement mortar touch up work / minor plastering.
41Providing and applying painting Two coats at all levels with Exterior grade Acrylic emulsion paint (approved brand, colour and manufacturer) confirming IS : 5411 Part I & II at all elevation to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces grinding, removing laitance, cement slurry, formoil, foreign matter etc., scaffolding, tools, tackles, equipment, materials, labour etc.., all complete as per manufacturer specifications and as directed by the Engineer-in-charge. Note: Rate includes filling all voids/pinholes in concrete by cement mortar touch up work / minor plastering.
42Providing and applying painting Two coats on wood work and other required internal surface at all levels with Synthetic enamel paint (Asian or approved brand, colour and manufacturer) to given an even shade including one under coat of suitable primer, preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-charge.
43Providing and fixing 1st quality ceramic glazed wall tiles confirming to IS 15622 of approved make in approved size, shade and colour (as approved by Engineer-in-charge), free from cracks, fissures & flake with straight edges & perfect corners fixed at right angies as per design and pattern required over 12mm thick bed of cement mortar 1:3, including machine / hand cutting to required size and shape, pointed neatly with white cement mixed with coloring pigment to match colour of tile, properly finished in al respects, curing, cleaning the surface neatly at the time of handing over the area, all materials and labour complete. Note: The sample tile shall be got approved by the Architect/Engineer before procurement.
44In Dadoslaid over 12mm thick backing in cement mortar 1:3
45Providing cement plaster skirting in cement mortar 1:3, 18mm thick finished with a floating coat of neat cement including curing, making uniform height, cleaning the surface neatly at the time of handing over the area all as per specifications and as directed y the Engineer.
46Providing and fixing VITRIFIED tiles in skirtingin different sizes with water absorption less that 0.08% and confirming to IS 15622 of Marbonite or approved make in all colours and shades in Glossy or Matt or satin finish (as required by Engineer-in-charge) laidin skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3including machine/hand cutting to required size & SHape, grouting the joints with white cement mixed with coloring pigment to match colour of tile patterns, curing, cleaning the surface neatly at the time of handing over the area complete all as per drawings and specifications. Note: The sample tile shall be got approved by the Architect/Engineer before procurement.
47150mm high skirting laid over 12mm thick backing in cement mortar 1:3
48Providing and fixing anodized aluminium (Anodised transparent or dyed to required shade according to IS: 1868 Minimum Anodic coating of grade AC 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z Sections and other sections of approved make confirming to IS: 733 and IS: 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required. (fittings, Glazing and panelling shall be paid for under relevant item) NOTE: 1) The rates for aluminium is inclusive of all fasteners required for fabrication and fixing in the walls. 2) All joints shall be of mittered joints. 3) A long M.S rod threaded at both ends to be provided in all aluminium door shutters in Top & bottom Horizontal members internally connecting Vertical members and fixed with M.S washers & nuts. 4) Only Aluminium members alone shall be measured and paid for.
49Supplying and fixing Rolling shutters with grill arrangements of approved make as per ISI standards made out of required size of MS Laths interlocked together throughout entire length and jointed together at the end by end locks mounted on specially designed pipes shaft with brackets, side guides and arrangements for inside &outside locking with Push and Pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs grade No. 2, and M.S Top cover of required thickness for Rolling Shutters.
50Rolling shutters PULL and PUSH type including top hood 1.25mm thick
51Extra over the cost of rolling shutters for providing and fixing Motorized arrangements including designing, providing spring less motor, control panels, limit switches, etc of "Swastik" or "Windoors" make or equivalent approved make all as per specification and as directed by the Engineer-in-charge.
52Exceeding 10.00 sqm and up to 16.80 sqm in the area
53Supplying, fabrication and fixing Steel doors with metal frame of size 125 x 65 mm made out of minimum 1.2 mm thick Galvanised steel, frame shall be received in knock down or welded condition with bottom tie rods and corner right angle plates for frame rigidity, minimum 3 nos. anchor bolts on each side, fixed in PCC 1:2:4, Steel flush shutter of 40 mm thick made out of prime quality galvanized steel sheet of minimum 0.8 mm thickness mounted on frame work of ‘C’ channel,filling with insulated spun mineral wool / Honey comb core, providing insulated glass vision panel of size 200 x 300 mm of 6 mm thick toughened glass with sealant in each shutter, with ironmongery as given below / approved. Further include painting using epoxy powder coating technology as per RAL shade complete as per drawing. Payment will be made based on clear structuralopenings. Door frame shall also be filled with light weight material / cement grout. Note: The cost includes breaking, chipping of side walls / transom mullions shall be done if the door opening size is not matching(if required).
54Steel Door Single shutter having accessories for single shutter a) 4 Nos of 125 mm long SS ball bearing heavy duty butt hinges with SS screws, b) 1 No vision panel with 6 mm thick toughened glass c) 2 Nos 300 mm long SS pull handle d) 1 No Mortice lock Godrej or equivalent 7 levers with handle on both sides e) Heavy duty hydraulic door closer f)12 mm dia 300 mm long SS tower bolt with SS screws
55Steel Door double shutter having accessories as Emergency door (below items are required in each doors) a) 125 mm long SS ball bearing heavy duty butt hinges with SS screws, b) Vision panel with 200 x 300 mmx 6 mm thick toughened glass c) 25mm dia, 300 mm long SS304, D -type pull handle d) 3 point locking panic bar system with external trim PHA 2000 or equivalen e) Mortice lock Godrej or equivalent 7 levers with handle on both sides f) Heavy duty hydraulic door closer g)12 mm dia 300 mm long SS tower bolt with SS screws
56Providing and fixing 30mm thick factory made PVC door shutters with door frames of approved colour/shade "Sintex / Akrosha" or approved equivalent make and wall thickness 2mm + 0.2mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners, including all accessories & fittings like 3 nos. 100mm SS hinges, 2 Nos 125mm Grip aluminium Bow handles, 2 Nos of Aluminium 75m Baby latch for each door complete all as directed at by Engineer-in-charge.
57Providing and fixing glazing with 6mm thick clear Float glass pane in aluminium doors, windows, ventilator shutters and partitions etc. with Neoprene gasket including cost of neoprene gasket complete as per the drawings and directions of the Engineer-in-charge.
58Supplyingand laying Roof insulation for buildings as specified inclusive of surface preparation,labour, tools, equipment, material etc., all complete as per specifications, drawings and as directed by the EIC, consisting ofsurface preparation a) Laying 50 mm thick Precast light weight foam concrete jointing with CM 1:3. b) Applying 75 mm thick in situ spraying of Polyurethane foam concrete. c) Applying one bituminous layer at the rate of 0.25 kg/sq.m. d) Providing average 50 mm thick screed concrete in N25 to required slope and grading in suitable panels after surface preparation. e) Applying one bituminous layer at the rate of 0.25 kg/sq.m. f) Laying 1st layer of minimum 4 mm thick APP membrane by LPG torch flame. g) Laying 2nd layer of minimum 4 mm thickmembrane over first layer. h) Painting one coat of reflective paint over the APP. i) Cutting the wall and tuck in the APP and seal with cement mortar 1.1 added water proofing compound Note: Suitable guarantee for 10 years is to be provided for this work.
59Providing and fixing Anodised Aluminium handles 75mm with 125 x 32mm including fitting with plate 175 x 32mm including fitting with necessary screws complete all as per specification and as directed by the Engineer-in-charge. Sample to be approved by the Engineer-in-charge.
60Providing and fixing anodised aluminium Baby Latch of size 100 x 10mm ISI marked (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete all as per specifications and as directed by the Engineer-in-charge.
61Providing and fixing coloured vitreous china European type water closet with "P" or "S" Trap with ISI marked colour solid seat and lid of Hindware or Equivalent approved make, 10 litre low level colour PVC flushing cistern with manually controlled device (handle level) conforming to IS: 7231, Flush bend fixing EWC with C.P. Brass screws, 15mm PVC heavy quality inlet connection of 600mm long, stop cock, including testing, commissioning & cleaning etc. complete all as per drawings and specification and as directed at site.
62Providing and fixing Viterious china white wash basin size 560x410mm/560x450mm, oval/round model (HINDWARE / PARRYWARE) with C.I. brackets, 15mm C.P. brass pillar taps of Jaquar / Parryware or approved equivalent make, 15mm x 600mm long PVC inlet connections, 15mm stop cock, 32mm Heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge.
63Supplying and fixing32mm heavy quality C.P.Brass Bottle trap / P-trap of make "Jaguar" / "Parryware" or other approved equivalent make with self cleaning design for wash basin all as directed by the EIC.
64Providing and laying approved quality mirror polished Granite slabs for flooring of required size & specified colour, pattern and free from cracks, fissures & flakes with straight edges & perfect corners laid at right angles as per pattern over a bedding of cement mortar 1:4, 20mm thickpointed neatly with white cement mixed with coloring pigment to match colour of slab and finished in all respects, including machine / hand cutting to required size and shape, moulding and polishing of exposed edges, fixingstone to level and plumb, anti-skid grooves for steps, curing, cleaning the surface neatly at the time of handing over the area, all materials and labour complete. Note: The sample Granite slab shall be got approved by the Architect/Engineer before procurement.
65In flooring 18mm thick Granite slab fixing with 20mm thick bedding in cement mortar 1:4
66Providing and fixing C.P. Brass towel rall 600mm long of "Jaquar" make complete fixed to walls with 30mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-in-charge.
67Providing and fixing 6mm thick Mirrors of size 600 x 460 x 6mm "Modi Guard" or approved equivalent make with bevelled edges complete with 6mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers complete all as per specifications and as directed by the Engineer-in-charge
68Providing and fixing Heavy Quality C.P. Brass Health Faucet with 1.50 metres flexible hose (Hand Showner) of "Jaquar continental model" or approved equivalent make and type as per specifications and as directed by the Engineer-in-charge. (Samples to be got approved by the Engineer-in-charge)
69Providing and fixing Heavy Quality C.P. brass 15mm dia Bib cock "ESSCO / PLATO" or approved equivalent as per specifications and as directed by the Engineer-in-charge. (Sample to be got approved by the Engineer-in-charge)
70Providing and fixing Heavy Quality 15mm nominal bore C.P. Brass Angle cock "ESSCO / PLATO" or approved equivalent make and type as per specifications and as directed by the Engineer-in-charge. (Samples to be got approved by the Engineer-in-charge)
71Supplying and fixing of CP Double coat hook of make aguar or other approved equivalent make including fixing, etc., all complete as per specification and as directed.
72Providing and fixing PVC inlet connection pipes heavy quality suitable for hot and cold including CP brass unions and nuts 15mm dia 600mm long as per specifications and as directed by the Engineer-in-charge.
73Providing, Laying, Jointing, fixing and testing for following diameter of Exposed on wall plumping lines Heavy quality (C-Class) Galvanized Iron pipes of TATA or approved equivalent make and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for 10.00 kg / sq.cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting, threading, jointing with hemp yarn, white lead, jointing Teflon tape, fixing in walls / trenches using clamps etc. including 2 coats of Synthetic enamel paint over a coat of primer, complete all as per specification and drawings, all as directed at site. Pipes with exclusive use of ISI marked approved make C-Class pipes
7440mm n/b G.I. pipe
75Providing and fixing the following sizes of gun metal full way gate valves female ends screwed bonnet integral seat non raising spindle class I, ISI marked to IS: 778 tested to 20 kg/sq.cm hydraulic pressure etc. complete all as per specification and as directed by the Engineer-in-charge.
7625mm nominal bore
7740mm nominal bore
78Providing and constructing Gully Chamber of internal size 300x300mmincluding providing, supplying and fixing 150 x 150mm stoneware gully trap with CI grating including excavation in all types of soils, backfilling, embedding inplain cement concrete 1:4.5:8 using 40mm size granite aggregates and constructing the above chamber with 115mm thick brick work in plastering over both internal and external faces of brick work with cement mortar 1:3, 12mm thick finished smooth with a floating coat of neat cement on both faces, providing and fixing CI cover with frame of 300 x 300mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design complete all as per specification and as directed by the Engineer-in-charge.
79Construction of Inspection chamber of following size internally up to 1.00 metre depth with brick masonry walls of 230/345mm thick using stock bricks in cement mortar 1:5 with necessary brick carbelling as required, plastering with cement mortar 1:3, 12mm thick for external sides of the chamber including excavation in all types of soils, back filling, providing and laying 150mm thick PCC 1:4.5:8 for foundation concrete forming bencing in PCC 1:2:4 using 20mm maximum size graded aggregate etc. complete all as per specification, drawing and as directed by the Engineer-in-charge.
80Inspection chamber of internal size 900x600mm
81Providing and fixing liquid soap dispenser in PVC container "VEGA" or approved equivalent make with all accessories and CP brackets including necessary screws for fixing complete all as directed by the Engineer-in-charge.
82Providing and fixing PVC Nahani trap of Prince / finolex or approved equivalent make conforming to the relevent IS code, heavy quality of self cleaning design with 75mm internaldia and outlet with 125mm dia, PVC gratingwith perforated holeson top including embedding incement concrete 1:2:4,forming circular holesby providing and fixing 110mm OD PVC pipes of required height upto floor level, levelling and rendering smooth,making good the floor, and wall etc. all completeas perspecifications. (Rate shall include cost of PVC pipe and it shall not be paid extra) .
83Providing and fixing Chlorinated PVC (CPVC) pipes for concealed pipeline work having thermal stability for hot & cold water supply (as ATM Standard 2846 & SDR - 11 Grade) including all CPVC Plain & Brass threaded fittings, fixing the pipe with clamps including chasing the walls, concealing the pipes and making good the same etc. This included jointing of pipes & fittings with CPVC Solvent cement & testing the joints complete all as per specifications, drawings and as directed by the Engineer-in-charge.
8420mm outer dia CPVC pipe
8525mm outer dia CPVC pipe
86Providing laying and fixing with uPVC pipelaid /embedded under floor slab and fixed to walls wherever required FINOLEX/PRINCE or other approved equivalent make of UPVC stabilized - SWR PVC pipes - Type B (Suitable for soil and waste discharge system having wall thickness of minimum 3.2 to maximum 3.8mm) conforming to IS - 13592 - Latest edition and PVC pasting type specials such as door bends, door tees and cowls etc. heavy quality for soil waste or vent or anti-syphonage PVC pipe with necessary PVC clips and joints.
8750mm OD UPVC pipes and specials.
8876mm OD UPVC pipes and specials.
89110mm OD UPVC pipes and specials.
90Providing and fixing 160mmdia, Cast Iron slotted gratings over the rain water down take pipes at roof including chipping and grouting, painting two coats of anticorrosive paint complete all as directed by the Engineer-in-charge.
91Providing, fixing & jointing the followingouter Dia of best quality UPVC rainwaterdown take pipes as per IS:4985 (with IS mark) with pressure rating of 6 kg/cm2(Class 3- Green mark) conforming to IS-13392, with ISI mark and heavy duty specials such as bends, junction, tail peace, collars swan necks,shoes etc. including fixing to the wall with adequate no. ofstandard MS fixing clamps at all elevations all complete as directed by EIC. Note: Masonry support near the shoe to be provided and the same will be measured under relevant items.
92200 mm OD
93Providing and laying non pressure NP2 class RCC Hume pipes conforming to IS: 458, with collars jointed with stiff mixture of cement mortar in the proportion of 1:2, laying to the levels, slopes including testing of joints etc. complete all as per the drawings and specifications and as directed by the Engineer-in-charge.
94300mm dia NP2 class RCC Hume pipe
95Supplying and fixing in position of heavy quality Cast Iron manhole frame and cover, steps etc of specified weight for the inspection chamber, valve chamber etc. all as per specifications and as directed by the Engineer-in-Charge.
96Dismantling of RCC works at all levels by manually / by mechanical including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge.
97Dismantling brick works at all levels by manually / by mechanical including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge.
98Chemical anchoring of TMT bars Fe500D grade steel reinforcement of dia upto 20mm embedding in RC structures including power drilling holes of appropriate diameter in reinforced or plain cement concrete upto depth minimum 10 times dia of the rebar or as per manufacturer specification, cleaning and filling the hole, fixing the reinforcement in position with RE 500 chemical of HILTI make or equivalent anchoring adhesives and finishing, scaffolding etc all complete as per specification and as directed by Engineer-in-Charge. Note: 1. Reinforcement will be measured and paid under relevant item. 2. Holes fouling with embedded steel shall be grouted by the contractor at his own cost
99Core cuttingin RCC structures at given location of specified diameter and different lengths, with rotary drilling, either by pneumatic machines or by electrical machines, at all elevations / positions without disturbing adjacent structures etc., for horizontal and vertical surface allcomplete as per drawings, specifications and as directed by Engineer-in-charge. Rates to include all labour, tools, tackles, consumables, scaffolding & staging etc.
100Upto 200mm diameter
101Above 200 mm & upto 300 mm diameter.
102Grouting at and around penetrations, construction joints and at all locations as specified in the drawingincluding necessary scaffolding, drilling holes of specified diameter, supply of grout material, PVC pipe nozzle, fixing, providing all necessary equipment like mixer and pump, manpower etc., allcomplete required to grout at specified pressure, cutting the pipes after setting of grout, sealing, finishing the surface to achieve required leak-tightness to the satisfaction ofthe EIC. Only quantity of grout injected shall be measured and paid for. This item is not intended for repair works falling under the scope of contractor for concreting works.
103Using Cement based grouting suitable for pumping with addition of approved anti shrinkage compound @ 2% weight of cementwithwater reducing admixture as required and as directed by the EIC.
104Supplying, providing and fixing approved Anchor fasteners /Cinch anchors of Carbon steel galvanised dash fastner (min 5 micron) of 10mm dia double threaded 6.8 grade counter sunk head screw comprising of polyamidePA 6 grade sleave size 10mm x 150mmat all placesincluding drilling, scaffolding, materials, laboursetc.,for wall / floor all complete as per drawings, specifications and as directed by the EIC.
10510 mm dia
106Phase Segregated DBs: Embedment, testing and commissioning of the following flush mounting POWDER COATED enclosure with double door,three phase (440 V, 50 Hz), Pre-wired 7 (seven) segment/ compartment, for the purpose of phase segregation and separation between incoming and outgoing, MCB DB with metal door enclosure, suitable for embeded mounting with the provision for FP/TPN MCB as incomer, DP RCCB (3 Nos) as sub incomer and SP MCB as outgoing, complete with all accessories including adopter box, dummy plates, suitable sizes of anchor fasteners, bolts and nuts along with washers etc., at suitable depth in brick work/RCC structure as per the detailed specification and as directed by the Engineer-in-charge.
107TPN, 4 Way Distribution Board Powder coated Per Phase Isolation DBs Per phase Isolation kit with all accessories
108TPN, 6 Way Distribution Board Powder coated Per Phase Isolation DBs Per phase Isolation kit with all accessories
109Supply and installation of 25 mm dia. sizes of heavy duty, circular, solid drawn, rigidsteel, hot dip galvanized on both sides (i.e.., inside and out side) ERW conduits for Electrical (Lighting and Power wiring) complete with all accessories like solid long bends, elbows, couplers, reducers, spacers, saddles, clamps, check nuts, nipples, 1 way / 2 way / 3 way / 4 way of 25 mm / 32 mm dia. 75 mm deep circular way / junction boxes, dummy boxes, copper conductor, copper clips etc., embedded on RCC roof slabs, columns, beams, floors, walls, brick masonry including chasing and replastering etc., and other accessories required to complete the works satisfactorily as per detailed specifications and directed by the Engineer-In-Charge. The scope of work includes supply and running of bareannealed 14 SWG Copper conductor over the conduit, junction and other accessories with copper clips and 14 SWG GI fish / pull wire inside the conduits which are embedded in the RCC roof slab, columns, beams, walls, floors and brick masonry.
11025 mm Dia 1.8mm, wall thickness GI Heavy Duty ERW Conduits with 75mm deep junction boxes
11140 mm Dia 2mm, wall thickness Heavy Duty ERW Conduits with 75mm deep junction boxes from DB to Pull box
112Supply and Installation of the following flush mounted, zinc passivated, modular metal boxes made out of 1.6 mm/1.8 mm MS sheet with neat finish and with standard dimensions suitable for fixing the standard sizes of front modular plates, complete with all accessories and accessories required for erecting the switch boxes in the RCC structure/Brick masonry walls/embedded parts with required number and suitable sizes of bolts and nuts along with the washers etc., as per the detailed specifications and as directed by the Engineer-In-Charge.
113150(W)X150(H)X80(D)mm, 1.6mm thick sheet Hot dip galvanised MS box
114400(W)X300(H)X200(D)mm, 1.8mm thick sheet Hot dip galvanised MS box
115Supply and installation of the following flush mounted, zinc passivated/cadmium coated, modular metal boxes made out of 14 SWG MS sheet with neat finish and with standard dimensions suitable for fixing the standard sizes of front modular plates, complete with all accessories and accessories required for erecting the switch boxes in the RCC structure/Brick masonry walls/embedded parts with required number and suitable sizes of bolts and nuts along with the washers etc., as per the detailed specifications and as directed by the Engineer-In-Charge.
1161/2 Module SB
1173 Module SB
11812 Module SB
119Supply and installation of the following size of tinned copper grounding pads embedded in the Cement floors, RCC / Brick Masonry walls/floors/columns/beams/ceiling etc., as per the scope of work, drawings and as directed by the Engineer-In-Charge:65 x 65 x 4 mm tinned copper grounding pads
120Jointing of 185 Sq.mm tinned stranded copper conductor with 65 x 65 x 4 mm tinned solid copper floor/wall/column/ceiling grounding pads
1218SWG copper wire : Supply and installation of the following sizes copper wires in built in trench as per the detailed specification. Size:-8SWG copper wire
122High bay luminaries:Supply, installation, testing, and commissioning of energy-efficient high bay industrial type LED luminaries of suspended type with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 20000, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to be installed at a height of 23 meter high bay with provision and connection for 4 Sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
123Wall mounted luminaries:Supply, installation, testing, and commissioning of energy-efficient wall mounted LED industrial type luminarieswith CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 2000, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall with provision and connection for 2.5 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
124Wall mounted/Suspended type luminaries:Supply, installation, testing, and commissioning of energy-efficient Wall mounted/Suspended type industrial LED luminaries with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 4000, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall /suspended from 5 meter ceiling with provision and connection for 2.5 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
125Supply And Installation, Testing, And Commissioning of 1x7W(Min.) 230V AC fed clustered led fitting on the wall suitable for washrooms as per specification and as per the instruction of EIC.(wall mounted)
126Fixing of the following front modular plates of various modules made out of engineering plastic of adequate thickness and with standard dimensions suitable for fixing in flush with the standard sizes of modular metal switch boxes for installing the standard modules of light/fan switches and power sockets, complete with all accessories as per the technical specifications.
1271M Front Plate
1282M Front Plate
1293M Front Plate
13012M Front Plate
131Fixing, testing and commissioning of the following modular type switches, sockets, plug tops, fan regulators in the standard front modular plates as per the technical specifications.
1321 No. 10 Amps 1 way SP switch
1331 No. 16 Amps 1 way SP switch
1341 No.6 Amps 3 pin shuttered socket with plug
1351 No. 6/16 Amps combined 3 pin shuttered socket with plug
136Supply, fixing, testing and commissioning Wiring points for lighting as per the technical specifications and the scope of work.
137Wiring point for lighting with 2 nos of 2.5sq.mm copper wires for Phase & neutraland 1 no of 2.5sqmm copper wire for earthing from DB to Control switch box (Avg. length - 52 Meters) as per the specification.
138Primary light point with 2 nos of 2.5sq.mm copper wires for Phase & neutral and 1 no of 2.5sqmm copper wire for earthing from control switch box to first Light point (Avg. length - 48 Meters) as per the specification.
139Secondary light point with 2 nos of 2.5sq.mm copper wires phase & neutral and 1 no of 2.5sqmm copper wire for earthing looped from Light point to Light point (Avg. length - 16 Meters) as per the specification.
140Wiring point for lighting with 2 nos of 1.5sq.mm copper wires for Phase & neutraland 1 no of 2.5sqmm copper wire for earthing from DB to Control switch box (Avg. length - 36 Meters) as per the specification.
141Wiring point for lighting with 2 nos of 1.5 sq.mm copper wires for Phase & neutral and 1 no of 2.5sqmm copper wire for earthing looped from Control switch box to control switch box (Avg. length - 18 Meters) as per the specification.
142Primary light point with 2 nos of 1.5sq.mm copper wires for Phase & neutral and 1 no of 2.5sqmm copper wire for earthing from control switch box to first Light point (Avg. length - 32 Meters) as per the specification.
143Secondary light point with 2 nos of 1.5sq.mm copper wires phase & neutral and 1 no of 2.5sqmm copper wire for earthing looped from Light point to Light point (Avg. length - 12 Meters) as per the specification.
144Supply, fixing, testing and commissioning Wiring points for power points as per the technical specifications and the scope of work.
145Primary power points: 2 nos of 2.5 sq.mm copper wire for phase and neutral and 1 no of 2.5sqmm copper for earthing wire from MCB at DB to Control switch and Socket (Avg.length -38Meters) as per the specification.
146Secondary power points: 2 nos of 2.5 sq.mm copper wire for phase and neutraland 1 no of 2.5sqmm copper wire for earthingfrom control switch and socket to control switch and socket(Avg. length - 26 Meters) as per the specification.
147Supply and Installation of 25mm GI Flexible Hose as per the scope of work and specification.
148Supply and providing 20mm dia GI conduit downrod for installation of luminaries, fans etc as per the detailed specification
149Supply, installation, testing and commissioning of the 32A 3P+N+E-FP Tempra plug and socket DBs with FP 20A-32A MCBMetal Clad Socket in sheet steel enclosure with Plugs and Socket as per the detailed specification.
150Supply Installation testing and commissioning of the following MCB / RCCB on Distribution Boards as per the detailed specification.
15180Amps,Four pole MCB
152125Amps Four Pole MCB
1536-32 Amps Single PoleMCB
154RCCB Double Pole 40A 30mA, TYPE AC
155Supply and Installation of laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification.
156Fabrication, assemling and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Ladder type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension:150mm width x 100 mm depth x 2.0 mm thickness
157Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Ladder type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension: 300mm width x 100 mm depth x 2.0 mm thickness
158Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Ladder type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension: 600mm width x 100 mm depth x 2.0 mm thickness
159Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Soild type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension: 150mm width x 100 mm depth x 2.0 mm thickness
160Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Soild type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension:300mm width x 100 mm depth x 2.0 mm thickness
161Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Soild type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension:450mm width x 100 mm depth x 2.0 mm thickness
162Fabrication, assemling and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Soild type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension:600mm width x 100 mm depth x 2.0 mm thickness
163Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Perforated type cable trays" with GI coupler plates, GI L-clips, GI bolts, nuts & washers with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension: 150mm width x 100 mm depth x 2.0 mm thickness
164Fabrication, assemling and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Solid type cable tray Cover"  with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension: 150mm type cable tray Cover with 2.0 mm thickness
165Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Solid type cable tray Cover"  with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension: 300mm cable tray Cover with 2.0 mm thickness
166Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Solid type cable tray Cover"  with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension:600mm cable tray Cover with 2.0 mm thickness
167Fabrication, assemling, supply and installation of hot dipped galvanized (average weight of zinc coating per unit area - 610 gm/Sq.m and coating thickness minimum of 75 microns) steel (IS:2062 Grade-BR), "Solid type cable tray Cover"  with thickness of 2.0 mm as per drawings, specifications and scope of work. Dimension:600mm cable tray Cover with 2.0 mm thickness
168Fabrication, supply and Installation of GI: MS fabrication With hot dipped galvanising Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.
169Supply installation and testing of Maintenance free earthing system (1x10feet x 5/8inch copper bonded steel rod, 22 kg Ground Enhancing Material (GEM) ) as per IS: 3043 including RCC Chamber and RCC cover slab as per Drawing
170Fabrication,supply, installationof the copper bonded steel round conductor of 10mm size in built-in trenches/ walls/column/floor/ slab including clamp and other fixing assessories as per tender specification
171Fabrication, supply, installationof the copper bonded steel round conductor of 16mm size in built-in trenches/ walls/column/floor/ slab including clamp and other fixing assessories as per tender specification
172Fabrication, supply, installation of the copper bonded steel round conductor of 16mm size including excavation and refillingas per tender specification
173Jointing of 10mm size copper bonded steel round conductorsby exothermic welding (CAD welding) of the Straight type Joint complete with all components and accessories as per the scope of work and drawings.
174Jointing of 16mm size copper bonded steel round conductorsby exothermic welding (CAD welding) of the Straight type Joint complete with all components and accessories as per the scope of work and drawings.
175Jointing of CBSC16 to 185Sqmm Copper conductor by exothermic welding (CAD welding) of the Straight type Joint complete with all components and accessories as per the scope of work and drawings.
176Jointing of 10 mm size copper bonded steel round conductorsby exothermic welding (CAD welding) of the Cross type Joint complete with all components and accessories as per the scope of work and drawings.
177Jointing of 10 mm size copper bonded steel round conductorsby exothermic welding (CAD welding) of the T- type Joint complete with all components and accessories as per the scope of work and drawings.
178Jointing of 16 mm size copper bonded steel round conductorsby exothermic welding (CAD welding) of the T- type Joint complete with all components and accessories as per the scope of work and drawings.
179Supply and erection of copper test link for termination of 10mm size and 16mm size copper bonded steel conductors at 1500mm above finished ground level
180Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. No cutting or drilling permitted after galvanisation. Size:25 X 6 mm GI flat
18114SWG copper wire : Supply and installation of the following sizes copper wires in built in trench as per the detailed specification. Size:-14SWG copper wire