Tender For E Tender For Electrification Work Of Shelter And Entrance Arch At Gate No.7 In Chennai Port Authority Under Two Cover System, chennai-Tamil Nadu

Chennai Port Trust-CPT has published Tender For E Tender For Electrification Work Of Shelter And Entrance Arch At Gate No.7 In Chennai Port Authority Under Two Cover System. Submission Date for this Tender is 28-02-2024. Electrification Work Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42088274
Tender For E Tender For Electrification Work Of Shelter And Entrance Arch At Gate No.7 In Chennai Port Authority Under Two Cover System
Open Tender
Indian
Tamil Nadu
chennai
28-02-2024

Tender Details

Tender For E Tender For Electrification Work Of Shelter And Entrance Arch At Gate No.7 In Chennai Port Authority Under Two Cover System

Key Value

Document Fees
Refer document
EMD
INR 9160.0 /-
Tender Value
INR 4.58 Lakhs /-

BOQ Items

Name of Work : e TENDER FOR ELECTRIFICATION WORK OF SHELTER AND ENTRANCE ARCH AT GATE NO.7 INCHENNAI PORT AUTHORITYUNDER TWO COVER SYSTEM
Sl. No. Item Description
1Supply of Distribution board shall be comprising with suitable way of 1 No.100 A, 4P,25KA, MCCB as incomer and 3 Nos. 20A, DP, MCB, 5 Nos.16A, DP MCB and 10 Nos. 10 A, SP, MCB as outgoing circuits as detailed in Schedule ‘A’.
2Installation of above DB as per Schedule ‘A’.
3Supply of 4 core 25 Sq.mm L.T. underground cable of 1100 V galvanized steel strip armoured XLPE cable with stranded Aluminium conductorconforming to IS 7098 Part I 1985 with latest amendments with ISI mark as per Schedule ‘A’.
4Laying of above cable as per Schedule ‘A’.
5Supply of 4 core 16 Sq.mm L.T. underground cable of 1100 V galvanized steel strip armoured XLPE cable with stranded Aluminium conductorconforming to IS 7098 Part I 1985 with latest amendments with ISI mark as per Schedule ‘A’.
6Laying of above cable as per Schedule ‘A’.
7Supply of 3 core 2.5 sq.mm copper conductor armoured UG cable for each LED fittings as detailed in Schedule ‘A’.
8Laying of 3 core 2.5 sq.mm copper conductor armoured UG cable for each LED fittings with proper Aluminium clamping on wall equal intervals as detailed in Schedule ‘A’.
9Supply of all materials and accessories to carry out the surface/concealed conduit wiring by using suitable size of PVC with 2 runs 4 sq.mm and one run of 2.5 Sq.mm PVC insulated unsheathed copper conductor wires from DB to 15A Switch and socket, SSB and AC MCB box as detailed in Schedule ‘A’.
10Supply of all materials and accessories to carry out the surface/concealed conduit wiring by using suitable size of PVC/case and capping with 3 runs 1.5 Sq.mm PVC insulated unsheathed copper conductor wires for fans, light fittings etc, through connected junction/ inspection boxes along with flush type control switch along with base plates and ceiling rose including terminations wherever necessary from flush type sub switch board to individual points as detailed in Schedule ‘A’.
11Supply of all materials and accessories to carry out with 2 Nos.5A flush type switch and socket outlet along with base plates including its supply along with suitable box as detailed in Schedule ‘A’.
12Installation of above 2 Nos. 5 A switch and socket in the suitable box as detailed in Schedule ‘A’.
13Supply of all materials and accessories for 15A flush type switch and 15A/5A socket outlet along with base plates and indication including its supply along with suitable box for 15 A plug as detailed in Schedule ‘A’.
14Installation of above 15 A switch and 15A/5A socket with suitable box for 15 A plug as detailed in Schedule ‘A’.
15Supply of one number 20A, DP, MCB with suitable metal type enclosure (C series MCB) as at various locations as per Schedule ‘A’
16Installation of above AC enclosure as per Schedule ‘ A’.
17Supply of all materials and accessories of 5Amps switch and socket outlet to be mounted in the flush type sub switch board itself including the supply of 5Amps modular switch and socket outlet with control switch and base plates and wiring to the plug as detailed in Schedule ‘A’.
18Installation of above 5 A switch and socket sub switch board itself as detailed in Schedule ‘A’.
19Supply of recess type diffused LED 2’ x 2’ light fitting suitable for 220V, 50 HZ A.C. 36 Watts, full bright with life of the fitting is not less than 30000 burning hours. Lumen output is not less than 100 lm/watt with all other accessories as detailed in Schedule ‘A’.
20Installation of above light fittings with all other accessories as detailed in Schedule ‘A’.
21Supply of surface type tube light fitting suitable for 220V, 50 HZ A.C.4 feet, 2 x 20 Watts T8 LED batten type slim tube light fitting. Light output shall be white in colour The life of the fitting is not less than 30000 burning hours. Lumen output is not less than 110 lm/watt as detailed in Schedule ‘A’.
22Installation of above light fittings with all other accessories as detailed in Schedule ‘A’.
23Supply of 1x 150 W LED Flood light shall be made up of die cast aluminum housing with high power LEDs with IP 66, Integral type as detailed in Schedule ‘A’.
24Installation of above light fittings with all other accessories as detailed in Schedule ‘A’.
25Supply of suitable way FRP/ Thermoplastic / SMC junction box IP 66 with Bolt & Nut type of brass / SS connectors of each fittings and loop to next light fitting with all other accessories as detailed in Schedule ‘A’.
26Installation of suitable way FRP/ Thermoplastic / SMC junction box IP 66 with Bolt & Nut type of brass / SS connectors of each fittings and loop to next light fitting with all other accessories as detailed in Schedule ‘A’.
27Supply of brown colour 1200 mm sweep ceiling fan with wide blades with step type electronic regulator and all other accessories at 7th gate detailed in Schedule ‘A’.
28Installation of above 1200 mm sweep ceiling fan at 7th gate as detailed in Schedule ‘A’.
29Supply of 2 TRcapacityslim high wall mounting typesplit air conditioner along with all required materials and accessories, as per schedule ‘A’
30Installation of 2 TRcapacityslim high wall mounting typesplit air conditioner, as per schedule ‘A’
31Supply of all materials of Maintenance free earthing as per schedule ‘A’.
32Installation of above maintenance free earthing as per Schedule ‘A’.
33Testing and Commissioning of the entire work.
34b) Installation