Department of Local Administration has published General-Kurumathur Gp- Pro No 156/24- Repairs For Minimast Highmast Solar Street Lights-Electrification-General Electrical Work. Submission Date for this Tender is 14-02-2024. Electrical Maintenance Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 13-Feb-2024 | REPAIRS FOR HIGHMAST MINIMAST SOLAR STREET LIGHT | Date | 14-02-2024 |
Sl. No. | Item Description |
1 | General Electrical Work |
2 | OD341376/2023-2024:Dismantiling existing defective 40 WLED Flood light fitting from lowmast/minimast and supply and replacing of approved make LED flood light fitting 50/60 with IP67 grade. Diecast Aluminiumbody , bracket, LED chip of approvede make including testing & giving connection Light fitting shall have replacement guarentee for 3 years. |
3 | OD341377/2023-2024:Suppling and providing or replacing analog type timers for LED street lights. Including setting timer6:30 P.M to 6 A.M Havels, LHT etc. |
4 | OD341378/2023-2024:Supply and providing or repalcing defective 2 pole contactor for street lights. |
5 | OD341379/2023-2024: Supply and providing or repalcing SPD 10KA grade including providing earth connection as required. |
6 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
7 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
8 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
9 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
10 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
11 | OD341380/2023-2024:Cleaning, scraping, painting existing metering cubicle/control gear box. Including making good working condition. |
12 | OD341381/2023-2024:Providing of railway pattern locking arrangement and to ensure locking provision for control gear box/meterimg cubicle |
13 | OD341382/2023-2024:Checking contactor, cleaning and makng good working condition of all light fittings ivluding attending annual maintenance and periodical inspection ensuring good working of all minimast for 3 year .Including attending petty repairs, replacement etc. as required once in every 3 months the AMC amount to be released after one year, for two years. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail