Rural Development Local Bodies Closing in 0 days TDR #42071520

Tender For Annual Plan-199/23 -Mcf -Electrification-Construction Ofmcf Building -Sm11l Pbig 19L-Electrification-Thanniyam Grama Panchayth-General Electrical Work

Issued by Local Bodies · thanniyam, Kerala
Tender Value
1.20 Lakhs
Estimated cost
Bid Submission
13 Feb 2024
0 days left
EMD
3000
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
thanniyam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Annual Plan-199 / 23 -Mcf -Electrification-Construction Ofmcf Building -Sm11l Pbig 19L-Electrification-Thanniyam Grama Panchayth-General Electrical Work

BOQ

Work Name:Annual Plan-199/23 -MCF -Electrification-Construction ofMCF building -SM11L PBIG 19L-Electrification-Thanniyam Grama Panchayth-General Electrical Work
Sl. No. Item Description
1Electrification
290.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
390.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
490.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
590.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
61.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
7OD297969/2022-2023:Supply and providing 5/7 Watts LED lamp on existing batten/ pendent/ bracket holder as required
8OD297970/2022-2023:Supply and fixing shades of the following types on existing batten/ pendent/ bracket fittings as required
91.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
10OD298305/2022-2023:Supply and providing 12W Outdoor bulk head fitting on wall/ ceiling and giving connections with required length 16/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire etc. as required (Luker eco LBKOVSL12 or equivalent make)
1190.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
1290.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
1390.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1490.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1590.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
1690.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
17OD298311/2022-2023:Supply, Conveyance installation, testing and commissioning of exhaust fan 200 mm light dutyin metal frame in the existing opening, fixing necessary anchor bolts, nuts etc as required including giving connection with the supplied wire along with the fan
181.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
191.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
201.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
211.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
221.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2390.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
2490.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
251.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
261.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
271.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
282.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
292.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
302.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
312.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
325.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
33OD225648/2022-2023: Supply and provding test joint for earthing system using 2 nos of the following strips including cutting and bending to shape ,drilling necessary holes and fixing to the watering pipe etc as required .2x25x6 mm GI strip
34OD225649/2022-2023:  Supply and providing earth lead from test joint to earth electrode using the following strips including cutting and bending to shape ,drilling necessary holes and fixing to the earth plate to test joint etc as required 25x6mm GI strip
3590.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
3690.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3790.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
3890.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
39OD225650/2022-2023:Supply and providing thefollowingsizesof bolt and nut with washers onthe existingM.S box/ earth bus etc. as requiredincluding drillingnecessary holes as required. 25x6mm brass nut and bolt .
40OD225651/2022-2023:Supply and providing thefollowingsizesof bolt and nut with washers onthe existingM.S box/ earth bus etc. as requiredincluding drillingnecessary holes as required. 12x3mm brass nut and bolt .
41OD225661/2022-2023:Supply and fixing the following accessories in the existing board and giving connections etc.32A 2 way Neutral link mounted on DMC/ SMC base
42OD225662/2022-2023:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and padlocking arrangement on existing angle ion frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc as required. Switch disconnector unit 32 A SPN AC 23A.
43OD225663/2022-2023:Supply and fixing the following accessories in the existing board and giving connections etc.32A HRC Fuse Base with HRC Fuse link
44OD225664/2022-2023:Supply and installation ofdust and vermin proofwall mounting SMC Meter boxsuitable for fixing KSEB Meter, cut out Neutral link etc, hinged door construction for the front side , providing vision panel, for the meter compartment, knock out for cable entry and exit. GS-MB 4030 (inside 400x300x190 mm) Sintex or its equivalent.
45OD225665/2022-2023:Supply and providing MS eye bolt hook in wall/parapet for binding support for KSEBservice wire connection
46OD225666/2022-2023:Preparing completion and test certificates for KSEB connection
47OD298312/2022-2023:Charges for installationof 0.5/1 H.P.submersible motor pumpset into wellafter connectingthedelivery pipes, and lead cable to motor and hanging the unit on ropeand setting into trouble free operationandconducting trail run satisfactorily.
48OD298313/2022-2023: Supply and providing25/32 mm dia reflex/nonreturn valve
49OD298314/2022-2023: Supply and providing 25/ 32 mm dia ball valve
50OD298315/2022-2023: Supply and providingspecial make SS connector with steel clampsuitable for25/32mm PVC fexiblepipe.
51OD298316/2022-2023: Supply and providing25/32 mm heavy duty duro flex/canoflex PVC flexible pipeas delivery pipe
52OD298317/2022-2023: Supply and providing submersible motor controller suitable for 0.5 H.P.Submersible motor pumpincluding Ammeter,Volt meter etc L&Tmake MR-G2/equivlent make .
53OD298318/2022-2023:  Supply of0.5 H.P,Singlephase open well submersible motor pumpset suitable for operation of 230V,50Hz a.c. supply having 8 mtrs to 20 mtrs head range ,capable ofdischarge 6180ltrs/Hr of clear waterat 12 Mtrs head(Kilosker KOSi.0520/equivlant make Akash/Texmo/Deccan) etc as requird . 
54OD298319/2022-2023:Supply and providing good quality nylon rope 20 mm and tying with require object outside the well
5590.3.17.2:Supply, conveyance and erection ofthe following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe
56OD298321/2022-2023:Supply and providing 9 litre capaacity GI fire Bucket painted in Post Office red with primer coat of red oxide and written with white paint "FIRE" mounted ob MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc as required
57OD298322/2022-2023: supply and installation of ABC Powder type (stored Pressure) Fire Extinguisher 4 Kg Capacity, ISI mark IS 15683 consisting of MS cylindrical body, squeeze lever, discharge valve fitted with pressure indicatinggauge, 30 cm long, high pressure discharge hose, nozzle etc with MAP Powder for fixing on wall with wall hook etc as required.

AI Tender Summary

OUR REF NO 42071520
AUTHORITY Local Bodies
TENDER VALUE 1.20 Lakhs
LAST DATE 13-02-2024
Authority
Authority Name Grama Panchayat
Work Description Annual Plan-199 / 23 -Mcf -Electrification-Construction Ofmcf Building -Sm11l Pbig 19L-Electrification-Thanniyam Grama Panchayth-General Electrical Work
Basic Detail
Tender No RE-ET-1/2023
Bidding Type Tender
Location
City thanniyam
State Kerala
Key Dates
Publish Date 05 Feb 2024
Submission Date 13 Feb 2024
Open Date 14 Feb 2024
Finance
Tender Value 1.20 Lakhs
Tender Fee 555
EMD 3000
Exemption Not Available
Document List
b99238ec-a2f9-4016-b96f-877d8471f1fb.html
BOQ_1009896.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 05, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 13, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 14, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b99238ec-a2f9-4016-b96f-877d8471f1fb.html

xls

BOQ_1009896.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders