Uttar Pradesh Expressways Industrial Development Authority has published Tender For Construction Of 3 No. Gate For Uttar Pradesh Defence Industrial Corridor (Updic) Lucknow Node, Village Bhatgaon, Tehasil- Sarojninagar, District Lucknow(Up). Submission Date for this Tender is 12-02-2024. Gates Supply Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
2 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also excluding cost of formwork in foundation |
3 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
4 | Foundations, footings, bases of columns, etc. for mass concrete under floor- |
5 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note Cement content considered in this item is @ 330 kg/cum excess/less cement used as per design mix id payable / recoverable separately). All work upto plinth level. |
6 | First class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work |
7 | Treatment of soil under existing floors using chemical emulsion @ one liter per hole, 300 mm part including drilling 12 mm diameter hole and plugging with cement mortar 1:2 (1cement : 2 coarse sand) to match the existing floor with chlorpyrlphos/lindane E.C. 20% with 1% concentration |
8 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
9 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
10 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
11 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
12 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note Cement content considered in this item is @ 330 kg/cum excess/less cement used as per design mix id payable / recoverable separately). All work above plinth level upto floor V level. |
13 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
14 | Suspended floors, roofs, landings, balconies and access platform |
15 | Lintels, beams, plinth beams, girders, bressumers and |
16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and abobe plinth lvl. Up to Plinth Lvl- |
18 | Above Plinth Lvl- |
19 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
20 | Steel work welded in built up section/frame work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. required. In grating, frame, guard bar, ladder, railings, brackets, gates and similar works |
21 | Providing & fixing fly proof wire gauze to windows, clearstory windows & doors with M.S. flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wide and 1.4 mm aperture on both sides. |
22 | 12 mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand) |
23 | 15mm cement plaster in single coat on fair side of single or half brick wall of mix: 1:4 (1 cement : 4 coarse sand) |
24 | Providing and laying Vitrified floor tiles Kajariya KERRO Brand or Equivailent brand of super quality in different size (thickness specified by manufacture) with water absorption less than 0.80% and confirming to IS 15622 of approved make in all colors & shade laid on 20mm thick cement mortar 1:4 (1cement 4 coarse sand) including grouting the joint with white cement and matching pigments etc complete (Size of tiles 600x600mm) [Flooring] |
25 | Providing and laying Vitrified floor tiles Kajariya KERRO Brand or Equivailent brand of super quality in different size (thickness specified by manufacture) with water absorption less than 0.80% and confirming to IS 15622 of approved make in all colors & shade laid on 20mm thick cement mortar 1:4 (1cement 4 coarse sand) including grouting the joint with white cement and matching pigments etc complete (Size of tiles 600x600mm) [Skirting] - |
26 | 25mm Thick Kota Stone Slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includig rubbing and polishing complete with base of cement morter 1:4. |
27 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) joining with grey cement slurry @3.3 kg/sqm, including pointing the joints with white cement and matching pigment etc, complete. |
28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting,risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed withpigment of matching shade complete. |
29 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick (for cupboard) including ISI marked stainless steel butt hinges with necessary |
30 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm. - |
31 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm - |
32 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm. |
33 | ONE primeing coat & one coat oil distemper on newb work including supply of all material, labour and t& p etc. requried for proper completion of work. As in item no.649 above but for every coat after the first coat. |
34 | Finishing wall with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat) |
35 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
36 | Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950 |
37 | Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950 |
38 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
39 | Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mm copper earth continuity wire& modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. |
40 | Wiring point for fan/fresh air fan (light duty exhaust/ Ceiling fan) with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable inthick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire & modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. |
41 | Wiring point for plug with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire& modular typeswitch & socket etc complete in all respects including matching color wash. |
42 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. |
43 | Supply and fixingof 6 Amp to 32 Amp. SPMCB (10 KA) C Curve (CAT-A) |
44 | Supply & wiringofsubmainwithFRLSH P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugethick PVC coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 2 x 1.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit. |
45 | 2 x 2.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit. |
46 | 2 x 4 sq. mm. with 2.5 sq. mmearth wire In 25mm dia conduit. |
47 | 2 x 10 sq. mm. with 6 sq. mmearth wire In 32mm dia conduit. |
48 | Supply fixing and concealing 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS no 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid, plastering with cement sand mortar finised to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of work. (for Telephone / Television / circuits) 20 mm dia. conduit (16 SWG) thick |
49 | 25 mm dia. conduit(16 SWG)thick |
50 | S/F of surface/flush mounting SPN distribution board with additional metal door without MCBcompletein all respect as directed at site by Engineer-in-charge. 8 WAYS ( CAT A ) |
51 | S/F of surface/flush mounting TPN distribution board with additional metal door without MCBcompletein all respect as directed at site by Engineer-in-charge. S/F of 40 Amp DP MCB (10 KA) ( CAT A ) |
52 | Eraction and testing of ceiling fan and regulator for room height upto 3.5 meters including including supply of 3mm thick GI pipe 19mm dia, Duly painted, completed in all respect. |
53 | Erection and testing of exhaust/ wall fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
54 | S/F of hexagonal fan box with hexagonal/ round GP Fan box of approved make made up of 1.0 mm thick ISI marled GP sheet spot welded four to eight holes of 25.4 mm for pip[e entry of the box. Holes should be semi shuttered tyupe with 0.5 mm GP sheet made upper & lower cover duly screwed fitted with 300mm round zink coated MS bar X 12mm & brand name should be embossed.Fixing withwiringconduit laid in the R.C.C.roofbeforeconcreting along with supply of all materials,labour, T&P etc. for proper completion of work. |
55 | Supply & fixing ofelectronic Fanregulator,dimmer, 120-280 VISI marked, ontheexisting switch board includingmaking connections, required material,labourT/Petc.for proper completion ofwork to the satisfaction of Engineer of work. |
56 | S/F of door chimeonPolishedM.D.F.E.G. board includingmakingconnectionsetc. complete in all respects. |
57 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length upto 2000mm, outer pipe 50mm, inner pipe 25, terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization upto 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducting the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I. strip with be extra) Make: As approved in U.P.P.W.D., & C.P.R.I Certified. |
58 | Supplying & Layingof 25mm x 3mm. G.I. strip for earthing purpose as required complete in all respects. |
59 | Supply and fixing of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duty concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
60 | Supply and fixing of recess/surface/ Pendent mounting round 10 Watt to 15 Watt LED Down Lighter having Powder coated die cast aluminiumhousing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. ( CAT - AAA ) |
61 | Supply and fixing of LED tube light with batten suitable for uo to 1 x 22 watt LED tube light fitting including tube on surface completein all respect. (CAT - AAA) |
62 | Supply and fixing of single LED light wall bracket 3 to 6 watt on matching M.D.F.E.G Board base etc. completed in all respects. ( CAT - AAA ) |
63 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 140 to 150 Watt. Confirming to IP 66 protection complete in all respect. |
64 | Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. |
65 | Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc. as required. 1 or 2 Module (75mmX75mm) |
66 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone Socket outlet |
67 | Supply and drawing followingpair, 0.5 sq.mm. FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required. 1 Pair |
68 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia |
69 | 5 pair Tag Block |
70 | Supplying, laying, testing and commissioning of following size anealed tinned copper conductor PVC insulated and sheathed armoured copper telephone cables 0.5mmwith suitable clamps, saddles and including making terminal joints complete as required 5 pair |
71 | Supply of AC230/250 volts, 50 HZceiling fanwith standarddownrod, blades, 2 nos. caps & regulator etc. ISI marked complete as required. 1200 mm sweep, 50W, 350 RPM |
72 | Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame and other accessories etc.complete 250 mm sweep 1250 rpm |
73 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size. 580x440 mm with integral type foot rests |
74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a 15 mm C.P. brass single hole basin mixer. |
75 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
76 | Providing and fixing toilet paper holder : C.P. brass |
77 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
78 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
79 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
80 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
81 | Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes. |
83 | 20 mm nominal outer dia .Pipes. |
84 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm dia nominal bore |
85 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
86 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
87 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation |
88 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
89 | Same as above but for under floor- |
90 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.(Note Cement content considered in this item is @ 330 kg/cum excess/less cement used as per design mix id payable / recoverable separately). All Work UP TO PLINTH LVL. |
91 | First class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work |
92 | Treatment of soil under existing floors using chemical emulsion @ one liter per hole, 300 mm part including drilling 12 mm diameter hole and plugging with cement mortar 1:2 (1cement : 2 coarse sand) to match the existing floor with chlorpyrlphos/lindane E.C. 20% with 1% concentration |
93 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
94 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
95 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
96 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
97 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note Cement content considered in this item is @ 330 kg/cum excess/less cement used as per design mix id payable / recoverable separately). All work above plinth level upto floor V level. |
98 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
99 | Suspended floors, roofs, landings, balconies and access platform |
100 | Lintels, beams, plinth beams, girders, bressumers and |
101 | Columns, Pillars, Piers, Abutments, Posts and Struts |
102 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and abobe plinth lvl. Up to Plinth Lvl- |
103 | Above Plinth Lvl- |
104 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
105 | Steel work welded in built up section/frame work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. required. In grating, frame, guard bar, ladder, railings, brackets, gates and similar works |
106 | Providing & fixing fly proof wire gauze to windows, clearstory windows & doors with M.S. flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wide and 1.4 mm aperture on both sides. |
107 | 15mm cement plaster in single coat on fair side of single or half brick wall of mix: 1:4 (1 cement : 4 coarse sand) |
108 | 12 mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand) |
109 | Providing and laying Vitrified floor tiles Kajariya KERRO Brand or Equivailent brand of super quality in different size (thickness specified by manufacture) with water absorption less than 0.80% and confirming to IS 15622 of approved make in all colors & shade laid on 20mm thick cement mortar 1:4 (1cement 4 coarse sand) including grouting the joint with white cement and matching pigments etc complete (Size of tiles 600x600mm) [Flooring] |
110 | Providing and laying Vitrified floor tiles Kajariya KERRO Brand or Equivailent brand of super quality in different size (thickness specified by manufacture) with water absorption less than 0.80% and confirming to IS 15622 of approved make in all colors & shade laid on 20mm thick cement mortar 1:4 (1cement 4 coarse sand) including grouting the joint with white cement and matching pigments etc complete (Size of tiles 600x600mm) [Skirting] |
111 | 25mm Thick Kota Stone Slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includig rubbing and polishing complete with base of cement morter. |
112 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) joining with grey cement slurry @3.3 kg/sqm, including pointing the joints with white cement and matching pigment etc, complete. |
113 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
114 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick (for cupboard) including ISI marked stainless steel butt hinges with necessary screws, |
115 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm. |
116 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm |
117 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm. |
118 | ONE primeing coat & one coat oil distemper on newb work including supply of all material, labour and t& p etc. requried for proper completion of work. As in item no.649 above but for every coat after the first coat. |
119 | Finishing wall with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat) |
120 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
121 | Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950 |
122 | Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950 |
123 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
124 | Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mm copper earth continuity wire& modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. |
125 | Wiring point for fan/fresh air fan (light duty exhaust/ Ceiling fan) with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable inthick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire & modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. |
126 | Wiring point for plug with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire& modular typeswitch & socket etc complete in all respects including matching color wash. |
127 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. |
128 | Supply and fixingof 6 Amp to 32 Amp. SPMCB (10 KA) C Curve (CAT-A) |
129 | Supply & wiringofsubmainwithFRLSH P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugethick PVC coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 2 x 1.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit. |
130 | 2 x 2.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit. |
131 | 2 x 4 sq. mm. with 2.5 sq. mmearth wire In 25mm dia conduit. |
132 | 2 x 10 sq. mm. with 6 sq. mmearth wire In 32mm dia conduit. |
133 | Supply fixing and concealing 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS no 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid, plastering with cement sand mortar finised to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of work. (for Telephone / Television / circuits) 20 mm dia. conduit (16 SWG) thick |
134 | 25 mm dia. conduit(16 SWG)thick |
135 | S/F of surface/flush mounting SPN distribution board with additional metal door without MCBcompletein all respect as directed at site by Engineer-in-charge.. 8 WAYS ( CAT A ) |
136 | S/F of 40 Amp DP MCB (10 KA) ( CAT A ) |
137 | Eraction and testing of ceiling fan and regulator for room height upto 3.5 meters including including supply of 3mm thick GI pipe 19mm dia, Duly painted, completed in all respect. |
138 | Erection and testing of exhaust/ wall fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
139 | S/F of hexagonal fan box with hexagonal/ round GP Fan box of approved make made up of 1.0 mm thick ISI marled GP sheet spot welded four to eight holes of 25.4 mm for pip[e entry of the box. Holes should be semi shuttered tyupe with 0.5 mm GP sheet made upper & lower cover duly screwed fitted with 300mm round zink coated MS bar X 12mm & brand name should be embossed.Fixing withwiringconduit laid in the R.C.C.roofbeforeconcreting along with supply of all materials,labour, T&P etc. for proper completion of work. |
140 | Supply & fixing ofelectronic Fanregulator,dimmer, 120-280 VISI marked, ontheexisting switch board includingmaking connections, required material,labourT/Petc.for proper completion ofwork to the satisfaction of Engineer of work. |
141 | S/F of door chimeonPolishedM.D.F.E.G. board includingmakingconnectionsetc. complete in all respects. |
142 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length upto 2000mm, outer pipe 50mm, inner pipe 25, terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization upto 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducting the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I. strip with be extra) Make: As approved in U.P.P.W.D., & C.P.R.I Certified. |
143 | Supplying & Layingof 25mm x 3mm. G.I. strip for earthing purpose as required complete in all respects. |
144 | Supply and fixing of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duty concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
145 | Supply and fixing of recess/surface/ Pendent mounting round 10 Watt to 15 Watt LED Down Lighter having Powder coated die cast aluminiumhousing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. ( CAT - AAA ) |
146 | Supply and fixing of LED tube light with batten suitable for uo to 1 x 22 watt LED tube light fitting including tube on surface completein all respect. (CAT - AAA) |
147 | Supply and fixing of single LED light wall bracket 3 to 6 watt on matching M.D.F.E.G Board base etc. completed in all respects. ( CAT - AAA ) |
148 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 140 to 150 Watt. Confirming to IP 66 protection complete in all respect. |
149 | Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. |
150 | Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc. as required. 1 or 2 Module (75mmX75mm) |
151 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone Socket outlet |
152 | Supply and drawing followingpair, 0.5 sq.mm. FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required 1 Pair |
153 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.. 150 mm dia |
154 | Providing, fixing, connecting & testingof Telephone Tag Block krone type in asuitable size 1.6 mm thick dust and vermin proof Sheet steel enclosure duly painted by synthetic enamel over anti corrosive primer, lockable and hinged cover with provision for cable through glands complete in all respects. 5 pair Tag Block |
155 | Supplying, laying, testing and commissioning of following size anealed tinned copper conductor PVC insulated and sheathed armoured copper telephone cables 0.5mmwith suitable clamps, saddles and including making terminal joints complete as required. 5 pair |
156 | Supply of AC230/250 volts, 50 HZceiling fanwith standarddownrod, blades, 2 nos. caps & regulator etc. ISI marked complete as required. 1200 mm sweep, 50W, 350 RPM |
157 | Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame and other accessories etc.Complete. 250 mm sweep 1250 rpm |
158 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
159 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a 15 mm C.P. brass single hole basin mixer. |
160 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
161 | Providing and fixing toilet paper holder : C.P. brass |
162 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
163 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
164 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
165 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
166 | Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
167 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes. |
168 | 20 mm nominal outer dia .Pipes. |
169 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm dia nominal bore |
170 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
171 | All Item Rate are Excluding GST |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy