Tender For Provision Of Connection Of Solar Power Generation System And Reduction Of Cmd From 1500 Kva To 1250 Kva Main Grid For Consumer No. 41001900218 At Vsn Nagpur, nagpur-Maharashtra

Military Engineer Services-MES has published Tender For Provision Of Connection Of Solar Power Generation System And Reduction Of Cmd From 1500 Kva To 1250 Kva Main Grid For Consumer No. 41001900218 At Vsn Nagpur. Submission Date for this Tender is 07-03-2024. Solar Generators Tenders in nagpur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42068949
Corrigendum : Tender For Provision Of Connection Of Solar Power Generation System And Reduction Of Cmd From 1500 Kva To 1250 Kva Main Grid For Consumer No. 41001900218 At Vsn Nagpur
Open Tender
Indian
Maharashtra
nagpur
07-03-2024

Tender Details

Provision Of Connection Of Solar Power Generation System And Reduction Of Cmd From 1500 Kva To 1250 Kva Main Grid For Consumer No. 41001900218 At Vsn Nagpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-02-2024
2 28-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-03-2024
3 04-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
INR 24 Lakhs /-

BOQ Items

Name of Work:PROVISION OF CONNECTION OF SOLAR POWER GENERATION SYSTEM AND REDUCTION OF CMD FROM 1500 KVA TO 1250 KVA MAIN GRID FOR CONSUMER NO. 41001900218 AT VSN NAGPUR.
Sl. No. Item Description
1B/R PORTION
2Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
3Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soilcomplete.all as specified and directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
5Removing excavated material in soils exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
6Material and labour for cement concrete type D2 1:4:8using 40mm graded stone agreggate in foundations, filling and mass concrete. all as specified and directed.
7Use and removal offormwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batterfor rough finished flat surfaces. all as specified and directed.
8Use and removal of roughformwork tosquare sides of pillars, posts, struts, piers, columns and stanchions for finished flat surfacescomplete all as specified and directed.
9Use and removal of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished flat surface complete all as specified and directed.
10Use and removal of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping).For rough finished flat surface complete all as specified and directed.
11Use and removal ofFormwork to chullah hoods, chajjas, troughs and similar items in cluding edges forrough finished flat surface complete all as specified and directed.
12Material and labour for RCC M-25 design mix (using 20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. all as specified and directed.
13Material and labour for RCC M-25 design mix (using 20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
14Material and labour for RCC M-25 design mix (using 20mm graded stone aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
15Material and labour for RCC M-25 design mix(using 20mm graded stone aggregates)Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
16Material and labour for RCC M-25 design mix (using 20mm graded stone aggregates) as in Chajja complete all as specified and directed.Note:- Srl Item No 11 to 15 : Reinforcement bars and formwork will be measured andn pauid seprately under relevant items.
17Material and labour for Mild steel TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
18Material and labour for Mild steel TMTbars 5mm dia over upto and including 10mm dia in stirrups, spacres and binders, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
19Material and labour for brick work with old size fly ash brick straight or curved on plan exc. 6 mtr mean radius built in CM(1:6)complete all as specified and directed.
20Material and labour for Rendering 5 mm thick on Ceilingin CM (1:3) finished the surface even and smooth without using extra cement. complete all as specified and directed.
21Material and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash all as specified and directed.
22Material and labour for Rendering 15mm thick on other than fair finish of bricks/concrete/stonesurface of wall in CM (1:4) mixed with WPC and finished the surface even and smooth without using extra cement complete all as specified and directed. Note : WPC will be measured and paid under supply only items.
23Supply onlyIntegral waterproofing compound
24Material and labour for preparation of newly plastered or un-plastered surfaces of walls, and applying two coats ofcement based paint over a coat of primercomplete all as specified and directed.
25Material and labour for Rendering 10mm thickin CM (1:6) on fair faces of brick surfacesand finished the surface even and smooth without using extra cement complete all as specified and directed.
26Material and labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified anddirected.
27Demolition of Brickwork or stone /boulder masonry built in cement mortar complete all as specified and directed.
28supply and fix pressed steel door frames for chowkat of size105x60mm withhinges ,100mm size (3 Nos each choukhat) with one or more rebates including necessary fixing lugs, lock strike plate, etc all as specified and as directed.
29Supply and fixing Flush shutters, 30 mm thicksolid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
30Supply and fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
31Material and labour for Sheet glass 5 mm thick selected quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane for window glazing complete all as specified and directed.
32Material and labour for Aluminum alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminum alloy and fixed complete all as specified and directed
33Supply and fix Floor door stopper 140mm long of aluminum alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor complete all as specified and directed.
34supply and fix Stainless steel butt hinges medium weight size 100mm long complete all as specified and directed.
35supply and fix aluminum handles cast type anodisedsize 150 mm long.complete all as specified and directed.
36supply and fix aluminum anodised barrel tower bolt of extruded section size 200 mm complete all as specified and directed.
37Material and labour for PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) for filling of pressed steel door frames complete all as specified and as directed.
38supply and fix Stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.40mm and fixed inwindows, or Stainless steel wire staples all as specified and as directed.
39Material and labour for preparing new Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide Primer complete all as specified and directed.
40Material and labour for preparing new wooden Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of pink Primer complete all as specified and directed.
41Material and labour for Hardcore of gauge n.exc 63mm deposited ,spread and levelled in layersn.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
42Material and labour for 75mmthick plain cement concreteusing (40mm graded aggregate) type D-2 (1:4:8) as in sub-basecomplete all as specified and directed.
43Material and labour forPCC, (1:2:4) TypeB-1 using (20mm graded stone aggregate) as in floor all as specified and directed.
44Material and labour for Kota stone flooring 20-25mm thick laid over and including 20mm screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishingall as specified and directed.
45Material and labour for Kota stone in skirting on certicle surfaces of wall 20-25mm thick laid over and including 10mm screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishingall as specified and directed.
46E/M PORTION
47Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, earthed electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade, of size 3 core 300 sq mm complete all as special and directed.
48Supply and fix cable jointing kit for 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured , Aluminium conductor cable of size 300 Sqmm earthed type complete all as special and directed.
49Supply and fix cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured ,Aluminiumconductor cable of size 300 Sqmm earthed type complete all as special and directed.
50Supply and fix cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminiumconductor cable of size 300 Sqmm, earthed Outdoor type complete all as special and directed.
51Material and labour for Indoor 33 KV Metering Cubicle with CT ratio 25/5 Amps, Class 0.2s Burden 10 VA and PTR 33/110, Class 0.2 burden 50VAas per MSEDCL specifications complete all as special and directed.
52Material and labour for Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp Suitable for 33000 volts 3 phase complete all as specified and directed.
53Supply and fix ABT Meter (-/5A, 11KV/v3/110V/v3, class 0.2S, ABT (15 min integration with 5 minutes sliding window) with recording of import/export KVAH compliant meter (Net meter) with recording of HT TOD import, export and net energies as per TOD Zone specified by MSEDCL with KVAH recording considering RKVAH (Lag + Lead, DLMS protocol, Auto reset programmed, AMR & MRI compatible optical port RS 232 and RS 485 communication port) complete all as specified and as directed. Note:- The rate quoted against this item is inclusive of expenditure incurred for application and agreement on stamp paper with MSEDCL. Nothing extra will be paid on this account.
54Earthing complete with copper earth plate electrode 60 cm x 60cmx3.15mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Cooper earth strip 20x3mm size by means of bolls, nuts, check nuts and washers of galvanized iron and earth strip protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering , perforated at bottom. 1.75 meter long placed on top edge of earth plate. charcoal and common salt fillingwith fixing arrangement, funnel wire mesh and including excavation and earth work in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. Note:(i) Copper earth strip beyond 1.75 metre will be measured and paid seprately. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost nothing extra will be paid on this account..
55Supply and fixcopper strip 20 x 3 mm as earth continuity conductor fixed in wall/floor/poles etc completeall as specified and directed.
56Supply, laying and testing XLPE insulated galvanized steel strip armoured electric cable multistranded (heavy duty) aluminum conductor 1100 volts grade of size 2 core 6 sqmmlaid in trenches/ducts/wall or through pipe and providing suitable type of cable lugs and making cable connection complete all as specified and directed.
57Supply and spread dry river sand in trenches for cable cushioning complete all as specified and directed. Note : Punned thickness shall be measured for payment purpose.
58Supply and laying unreinforced Pre cast Concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed
59Supply and laying Reinforced Pre cast Concrete cable cover class EHV, class HV, Type 1, flat, size 450mmx 230mm x 50mm complete all as specified and directed
60Supply and fix GI tubing light grade of 40 mm dia for protection of LT cable complete all as specified and directed.
61Material and labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, single core conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade, ISI marked, 20 mm dia including all accessories, concealed in wallsby cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes ,switch plates of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly complete all as specified anddirected for the following.
62One light point controlled by one way switch
63One exhaust fan point controlled by one way switch.
64Onesocket outlet 3 pin 6AMP on same board.
65All as per item No 59 above but 2.5 sq mm cable sizewith 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board.complete all as specified and directed.
66Supply and fixT-8 led tube 4ft20 W LED Tube Polycarbonate type having nominal system lumen output of 2100 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70.The luminaire should have a colour temperature of 6500K and CRI>83. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The total power consumption should not exceed 18W (including driver).complete all as specified and directed. Make :Phillips/CG/WIPRO/Bajaj.
67Supply and fixdecorative box typefittingwith blue coloured end caps pre wired for LED tube energy saving of 20 Watt complete all as specified and directed. Make : Phillips/CG/WIPRO/Bajaj
68Supply and fixSwitch modular type, single pole one way 6 Amps, 250 volts Ac suitable for modular switch boxes without indicator, all as specified and directed. Make : Legrand Cat PartNo. 675501 Or equivalent model in Havells,Anchor.
69Supply and fixsocket modular type6 Amps 3 pin 2 module250 volts all as specified and directed. Make : Legrand Cat Part No. 675551 Or equivalent model in Havells/Anchor.
70Supply and fix for ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals all as specified anddirected. Make : Leader/ Anchor/ Havells.
71Supply and fixsocket outlet modular type 6/16 Amps, 3 pin combine, 2 module,240 volts all as specified and directed. Make : Legrand Cat Part No. 675555 Or equivalent model in Havells/Anchor.
72Supply and fixswitch modular type 16 Amps,one way with indicator, 1 module,240 volts all as specified and directed. Make : Legrand Cat Part No. 675513 Or equivalent model in Havells/Anchor.
73Supply and fixsheet metal enclosures for SPN DB"s with metal double door for incorporating MCBs,IP-43 , 8 way, 240 volts, as per IS-8623 all as specified anddirected.
74Supply and fix MCB SPN, 32 Amps, breaking capacity 10 KA "C" curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc complete all as specified and directed. Make : Legrand Cat Part No. 408617 or equivalent model inABB/Seimens
75Supply and fixMCB SP 06-32Amps, breaking capacity 10 KA "C" curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. all as specified anddirected.Make : Legrand/ABB/Seimens.
76Supply & Fixing Exhaust fan heavy duty Metal body 18" 450 mm sweep anti dust, sweep 230 V, 50 Hz, complete with all accessories & connector etc internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including making suitable hole for fixiing of exhaust fan and making good the distrubed surfacecompleteall as specified anddirected. Make : Bajaj, CG, Orient, Usha
77Material and labourL for MCB blanking plate all as specified anddirected.
78Note : The amount against Schedule of Credit on Page No. 36 shall be deducted from the total amountquoted against Sch "A"while deriving contract Sum for Acceptance.