Tender For Rate Contract For Providing Call Basis Maintenance Of Diesel Engine Alternator Sets In Various Te / Btssitesunder Bajaipur, jaipur-Rajasthan

Bharat Sanchar Nigam Limited-BSNL has published Tender For Rate Contract For Providing Call Basis Maintenance Of Diesel Engine Alternator Sets In Various Te / Btssitesunder Bajaipur. Submission Date for this Tender is 20-02-2024. Diesel Engines Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42064980
Tender For Rate Contract For Providing Call Basis Maintenance Of Diesel Engine Alternator Sets In Various Te / Btssitesunder Bajaipur
Open Tender
Indian
Rajasthan
jaipur
20-02-2024

Tender Details

Rate Contract For Providing Call Basis Maintenance Of Diesel Engine Alternator Sets In Various Te / Btssitesunder Bajaipur

Key Value

Document Fees
INR 590 /-
EMD
INR 11600.0 /-
Tender Value
INR 5.80 Lakhs /-

BOQ Items

Name of Work : -Rate Contract for Providing Call Basis Maintenance of Diesel Engine Alternator Sets in Various TE / BTSSitesunder BAJaipur
Sl. No. Item Description
1Visit charges to attend fault of DEA Set on call basis / complaint basison behalf of written Job order from SDE(E) concerned for different TE / BTS sites under jurisidication including attending the minor faults involving nomaterial and submit detailed report for major faultto the Engineering -In-charge i/c fare charges to visit the site from HQ etc complete as reqd.
2Note:- (1). Visit Charges are not payabie, if cost of work executed at particular site is beyond Rs 5000/-. (2). The Charges shall be paid onlysubject to submission of detailed site visit report in Job Order along with billfor sites where servicing / major repairing work not carried out by agency. (3). Charges shall be paid proportinately to attend the complaints e.g. 3 Sites for visit up to 30 KM"s on a route, 2 Sites for visit more than 30 KM & Up to 60 KMon a route and 1 Site for visit beyond 60 KM from HQ .
3Pdg & Makingof General Servicing of the following capacity E/A sets of different make and model installed at TE/BTS Sites comprising of following jobs i/c Fare and labour chargei/c complete checking of E/A Set after servicingand replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd.
4i). Cleaning the bowl inside as well as out side of fuel filter and oil filter , replacementof sealing ring.
5ii). Cleaning the fuel strainer with clean diesel i/c pressure testing of fuel injector and it should be as per manufacturer recommendation.
6iii). Cleaning the cooling system (Raditor)
7iv). Replacement of Air cleaner element if reqd.
8v). Checking all belt Drives and retensioning the same etc as reqd.
9vi). Remove the tapet cover and checking the valve clearance gap between rocker arm toe and valve stem end in cold conditionas per manufacturer recommendationi/c replacement of tappet cover gasket if reqd. etc. as reqd..
10vii). Cleaning the entire E/A Set (inclusive of fins, blower and block). i.e. oil & grease etc.
11viii). Cleaning of diesel tank if reqd.
12ix).Checking of charging alternaror, starter self and engine control panel connection, gauges and indicators and its fuction.
13x). Checking and setting of fuel supply and time as per manufacturer recommendations.
14NOTE:1. After servicing the set, a trial test also be carried outby the firm for 30 minutes and check its performance & submitt the readings of out put voltage, current(for each phase) and frequency, LOP, RPM, Hr Meter Reading with working condition status report etc. in Service Report. 2. This item shall be paid only after submission of desired report along with Job Order duly verified by concerned telecom authorities &SDE(E) Concerned.
15Up to 20 KVA DEA sets
16More Than 20 KVA & Upto 32.5 KVA DEA Sets
17More Than 32.5 KVA & up to 55 KVA DEA Sets
18Replacement of the following Parts / Itemsin existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.( Note- Make and Model as per manufacturer recommendation )
19(a) Diesel Filter Element Set ( 1 Ltr )
20(b) Oil Filter Element ( 1/2 Ltr )
21(c) Oil Filter Element ( 1 Ltr )
22(d) Diesel Filter Element Set ( 1/2 Ltr )
23(e) Oil Filter Set suitable for E/A Set of 50/55 KVA
24(f) Lubricating Oil Multi Grade ( 20W40)
25(g) Steel Wire Braided Fuel Pipe Line
26(h) Stop Solenoid12 Volt
27(i) Starting Key with Switch
28(j) Mechanical Type RPM Cum Hr Meter
29(k) Mechanical Type RPM Cum HR Meter Chain
30(l) Battery Leads Red & Black Standard Length & Size i/c terminals
31(m) Coolant for Radiator of superior quality or as recommended by manufacturer
32(n) V-belt
33(o) Hose pipe set
34(p) Techo Drive Unit
35(q) Fuel Feed Pump assembly.
36Replacement of the following Parts / Itemsin existing Different capacity and make E/A Set AMF / Manual ControlPanelsI/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.( Note- Make and Model as per manufacturer recommendation)
37(a) Solid state SMPS or SCRbased battery chargerssuitable up to 12v, 180 AH Battery ( Make - VNT or Similar Superior make)
38(b) Push Button Switch for Start/ Stop/Reset
39(c) 12 V DC / 220 V ACHR Meter Counter Type
40Supplying & fixing of 12 Volt Battery Operated Self Starter suitable for Starting of Enginei/c fixing the same on the DG set making connections testing etc. complete as reqd. ( Make- Autolek or Similar Superior Make)
41Supplying & fixing of 12 Volt Battery Charging Alternator on the existing DG set i/c making connections testing etc. complete as reqd. ( Make -Autolek or Similar Superior Make)
42Replacement of following faulty items in the existing Alteranator up to 55 KVA Capacity at TE / BTS Sitesi/c dismentling the faulty, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd.
43(a) AVR( M/s National or Similar Superior Make)
44(b) Power Diode for Rotating Rectifier Assembly
45Pdg General Servicing and Repairing of Battery Charging Alternator/ Dynamo that’s I/c dismentalling of equipment , greasing and oiling of bearings and other parts ,repairing of rectifier assembly , replacement of carbon brush etc. and complete checking of battery operated alternator and fixing with proper alignment etc complete as reqd.
46Repairing & General Servicing of the existing faulty radiator up to 100 KVA Diesel Engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiatorassemblyincluding transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd.
47Pdg General servicing and Repairing of 12 Volts Engine Starting Self that I/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of Carbon Brush ,Housing etc.complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd.
48Providing of following Core and Size PVC insulated and PVC sheathed grade Aluminium conductor armoured cable of 1.1 KV grade confirming to relevent IS-Specification complete as reqd. ( Note - Cable shall be provided at Site / Handed over to SSA Authority as per direction of Engg. in Charge )
49(a) 2 Core 10 Sqmm
50(b) 4 Core 16 Sqmm
51LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
52Upto 35 sq. mm (clamped with 1mm thick saddle)
53Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
54Upto 35 sq. mm
55Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
56Upto 35 sq. mm
57Supplying and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required.
582 X 10 sq. mm (19 mm)
594 X 16 sq. mm (28mm)
60Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
61S/I/T/C of32 amps four poleONLoad Side Handle operated change over switchinsteel enclosure capable ofworking 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
62S/I/T/C of63 amps 2 Pole ON Load Side Handle operated change over switchinsteel enclosure capable ofworking 240 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
63S/I/T/C of63 amps four pole ONLoad Side Handle operated change over switchinsteel enclosure capable ofworking 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
64Providing and fixing 63 A TPN disconnector fuse switch unit in sheetsteel enclosurea/wHRC fuses capable ofworking 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail