Tender For Construction Of Park At Ward No.15 Survey No.971/6 Kavery Nagar In Perundurai Town Panchayat
Tender Value
35 Lakhs
Estimated cost
Bid Submission
15 Feb 2024
0 days left
EMD
35000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
perundurai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Park At Ward No.15 Survey No.971 / 6 Kavery Nagar In Perundurai Town Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Earth work exception for foundation in all solids and sub-solids to full depth as may be directed except in hard rock requiring blasting but inclusive shoring, structing and baling out water wherever necessary and filling the sides of foundation with excavated earth in layer of not more than 15cm thick well rammed and consolidated and depositing the surplus earth in all places shown by the department officers with initial lead and lifts etc. including leaving the sites complete complying with standard specifications etc complete. ( Column ) |
| 2 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc. complete. complying with std. specification (Foot Path) |
| 3 | Earth work excavation and depositing on bank with initial lead of 10m and lift of 2m in narrow trenches for laying of pipes for water supply hard stiff clay,stiff biack cotton, hard red earth, shales, murram gravel, stoney earth and erath mixed with small size boulders and hard gravelly soil the following type of soils as directed by departmental officers (Pipe Line) |
| 4 | Supplying and filling in foundation and basement with filling M sand in layers of not more than 15 cm thick well rammed consolidated etc. complete complying with standard specification and as directed. |
| 5 | Cement concrete 1:4:8 Mix(One Cement,four Sand,Eight jelly) using 40 mm ISS Gauge HBG Metal including cost and conveyance of all materialsto the work site including all labour charges for mixing, laying, ramming, consolidation and curing etc., complete as per standard specifications. |
| 6 | Supply and erection of Centring for sides and soffits of all concrete works using mild steel sheets supportted withcasurino props for vertical supports including cost and conveyance of all materials to work site including all labour charges etc., complete. a) Footing, Grade Beam & Kerb wall sides |
| 7 | b) Column |
| 8 | c) Roof Slab and Roof beam |
| 9 | Reinforced cement concrete1:1.5:3 Mix(One cement one point five sand and three hard broken stone)using 20 mm ISSHBG Metalincluding cost and conveyance of all materialsto the work site including all labour charges for mixing,laying,ramming,consolidation and curing etc., complete as per standard specifications. |
| 10 | Supplying, Fabricating and placing in position TMT bars for all reinforced cement concrete items of work including cost of steel transporting straightening cutting, bending, cranking binding welding etc.Including cost of binding wire MS.chairs laps to fix the reinforcement in all positions, all labour and materials complete complying with standard specifications and drawings and as directed by the departmental Engineers. |
| 11 | Brick work in cement mortor 1:5 (One cement five sand) usingwell burnt chamber bricks of size9 \"x4 3/8 \"x2 3/4 \" all cost and conveyence of material to the site and all labour chargesincluding curing etc complete complying with standard specification. |
| 12 | Plastering with cement mortar 1:5 (one cement and five sand) 12mm thick in all floors including curing etc., complete complying with standard specification and as directed. |
| 13 | Special Ceiling Plastering with cement mortar 1:3 (one cement and five sand) 10mm thick in all floors including curing etc., complete complying with standard specification and as directed. |
| 14 | Plastering with cement mortar 1:3 (one cement and five sand) 20mm thick in all floors including curing etc., complete complying with standard specification and as directed. |
| 15 | Supplying and fixing of M.S grill of approved design for doors, windows and ventilators using necessary mild steel flats for inner and outer memebers which should be fixed to window frames inclusive of priming coat of best approved quality red oxide primer etc., complete complying with standard specifications. |
| 16 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.(SOR Item no.264,P.No.65) |
| 17 | Supplying and fixing over the floors best quality of Scratch Ceramic Tiles of 30 c.m x 30c.m x 6mm sizeof approved colour laying with cement mortor 1:3 mix pointing the joints with colour pigments etc.Complete. |
| 18 | Dadooing the walls with glazed tiles of 30 c.m x 30 c.m 6mm size laid in cement mortor 1:2 mix 10mm thick and pointing with 0.40 kg white cement per m2 etc., |
| 19 | Supplying and fixing in Position of Indian Oriya pan type water closet with “P’’ or “S’’ trap to set inbrick jelly concrete 1:4:8 Mix concrete 10 cm thick using 20mm brick jelly and top finished with c.m. 1:3 mix 20mm thick without any leakage etc. complete. |
| 20 | Supplying and fixing in position best Indian make white glazed earthenware WASH HAND BASIN of 560x406mm with a a pair of C.I. Brackets, 15mm dia C.P. Pillar tap, 32mm G.I. Waster water pipe, 32mm dia C.P. Brass waster coupling, plug with chain, 15mm dia PVC connection, 15mm G.M. wheel valve with ISI mark and necessary G.I. union and G.I. Elbow, including fixing wash hand basin in position with white lead, clamps, teakwood plugs, screws, rubber washer etc., complete without any leakage complying with standard specifications. |
| 21 | Wiring with 2x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor cable of 1100V grade insuitable heavy gauge MSconduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 14SWG TC wire for light point / fan point (for electronic regulator) SD-26 |
| 22 | Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K. Lite) suitable for11W CFL lamp with CFL. SD-83 |
| 23 | Plain Cement Concrete 1:2:4 Mix (one part cement, two part sand and four part of aggrigate) using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc., complete as per TNDSS NO: 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge. |
| 24 | Supplying and laying Precast Designer Paver Block confirming to IS 1568-2006 specification manufacturing and laying standard of M40 grade 63mm thick (table clauses 5 and 9.14) suitable for bus terminals industrial complexes road on expensive soils etc., including the cost of paver block of size 225mm x 12.50 mm x 80mm and conveyance of materials to work site mentioned in the tender schedule cost of loading and unloading handling during over Stone dust of 150 mm thick (excluding the cost of sand) conveyance paver block cutter to site and hire charges of vibrators and block cutter operator and labour for leveling the sand to paver block etc., complete ISI 15658-2006. |
| 25 | Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specificationsfor 10 sqm |
| 26 | Painting Priming coat on new Iron works with ready mixed paint of approved quality -10m2 |
| 27 | Conducting Geophysical Survey Charges including all other charges. |
| 28 | Drilling of 150mm vertical bores in Hard rock areasto the required depth as directed by the TOWN PANCHAYAT Officers including labour charges for inserting casing pipes, assembling in the drilled holes, including welding the joint if necessary grouting the casing pipes etc., and including transportation charges for the rig and supporting vehicles from one place to another. a) Upto 150m depth below Ground Level |
| 29 | b) From 151m to 180m |
| 30 | c) From 181 m to 210 m |
| 31 | d) From 211 m to 240 m |
| 32 | Supply and Delivery Of unplasticised plain PVC 150mm dia casing pipes of the following diameter in 3 metres length with screwed and socket ends and centering guides for every 15 metre length of pipes as per IS 12818/2010 and as amended from time to time to suit deepbore well upto 80m depth (CS) for delivery at site of work with IS marking including loading, unloading freight, transit insurance etc., complete. |
| 33 | Supply and delivery of (50LPMX200 HEAD) 5.00 HP THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 15OMM DIA BOREWELL AS PER IS 8034/2002 WithOUT PANEL BOARDSupply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 with latest amendments and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainlesss steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/difuser With ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor asper IS9283 suitable for operation in AC 3 phase 415v+/- 10%,50 HZ +/- 5% |
| 34 | THREE PHASE PANEL BOARD STAR WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of Star-Delta starter confirming to IS 13947 and IEC 947 suitable KW raing For operation in AC3/Phase/5OHZ(+/-5%) and 415V (+/-10%) including 3 pole magnetic Contactor with under voltage release-3 nos. CT operated Ammeter(65 mm dia) with suppressed Scale, Voltmeter (65mm dia), Voltmeter selector Switch, Minature circuitr braeker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor. dry running preventor and on/off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, Including the capacitor (the cost of capacitor is to be taken separately) |
| 35 | Supply and Delivery of 4 sq.mm PVC Insulated and Sheathed 3 core flat type copper cable confirming to IS 694/1990including loading and unloading charges etc., complete. |
| 36 | Supply and delivery of40mm dia UPVC column pipeincluding all charges etc complete. a) 50mm GM Gate Valve |
| 37 | Supply and fixing ofthe following PVC,GI & GM Pipes & specials including all charges a) 50mm GM Gate Valve |
| 38 | 50mm GM NRV |
| 39 | Supply and Delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mm x 4mm alround covered with 16 gauge Ms Sheet and Kiosk door Made up of MS plates of Size 25mm x 3mm including cutting ,Welding,Grinding,locking arrangement and labour charges etc.., |
| 40 | Labour Charges for erection 5 HPSubmersible pumpset in borewell/open well including fixing and jointng submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth Values erection clamps pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter,Ammeter,three pilot (indicating ) lamps capcitor single phasing preventor, Water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days |
| 41 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\" x 1/8\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD127) |
| 42 | Supply and run of 4 of 4 sq.mm. (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade on 7 / 20 GI bearer wire for service connection mains.(SD 67) |
| 43 | Supply and run of 4 of 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class \"B\") bent at both ends with necessary angle iron up right and end supports for mains (SD 72) |
| 44 | Supply and delivery of 1000 liter H.D.P.E water tank with ISI mark(1270/1996) as per standard specification etc.,complete. complying with std. specifications. |
| 45 | Supply and delivery of 63 mm PVC Pipeouter diameter 6kg / cm2 I.S.I.makeincluding cost and conveyance Complete complying with standard specifications and as directed by the departmental Engineers. |
| 46 | Laying and joining of 63 mm outer diameter 6kg / cm2 I.S.I.make PVC and GI pipes with Proper gradient including cost and conveyance Complete complying with standard specifications and as directed by the departmental Engineers. |
| 47 | Refilling the Excavated earth including well Consolidation including cost and conveyance complete complying with standard specifications and as directed by the departmental Engineers. |
| 48 | Supply & Fixing of Double Swing Two FRP Seats with 8mm stainless steel chain, top bar 60mm, 10ft long pipe with sealed bearing & hooks. Support pipes 4 no’s 10ft long. Including painting & fixing. |
| 49 | Supply & Fixing of Seesaw Four FRP Seater 60mm pipes 7ft long with sealed bearing stands made of 60mm pipe 6ft long, 3ft height. Including painting & fixing. |
| 50 | Supply & Fixing of Seesaw 2 FRP Seater 60mm pipes 7ft long with sealed bearing stands made of 60mm pipe 3ft long, 3ft height.Including painting & fixing. |
| 51 | Supply & Fixing Merry Go Round (6 Metal Seats) 5 ½ Dia 60mm heavy center pipe, double bearing arrangements, 18g GI sheet 25 and 32mm pipe. Including painting & fixing. |
| 52 | Supply & Fixing Stainless Steel Slide Jindal 304 quality 18g 10ft long straight, with metal platform & ladder made of 50*25mm pipes 32mm support pipes.Including painting & fixing. |
| 53 | Supply and fixing of Park bench aristocratWith casting legs , 5 ft long 50*25 mm pipes , height 18 including painting and fixing etc complete |
| 54 | Providing various designs of Animal Dust bins made of 3 layer fiber structure with multi colour powder coating. The height of the dist bins 4 feet available models are penguin, Rabbit, Fish and monkey etc.,Complete |
| 55 | PVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 56 | supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . (SD 543) |
| 57 | Supply and laying of 2 core 6 sq.mm. PVC Armoured UG Cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD197) |
| 58 | Supply and Fixing of 100A Panel Board incoming 100A TPN Switch with variousrange of TP/DP/SP MCB with suitable angle iron frame work |
AI Tender Summary
Tender Timeline
Feb 06, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 15, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 15, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender