Tender For Supply Of Eee Lab Items, Thiruvallur-Tamil Nadu

Directorate Of Technical Education-DTE has published Tender For Supply Of Eee Lab Items. Submission Date for this Tender is 13-02-2024. Counters Tenders in Thiruvallur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42060832
Tender For Supply Of Eee Lab Items
Limitted
Indian
Tamil Nadu
Thiruvallur
13-02-2024

Tender Details

Supply Of Eee Lab Items , Supply Of Eee Deparment Equipment Noc Items , Two Speed Pole Changing Circuit With Motor - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Speed 1, Speed 2 And Stop Push Switches - Provision To Connect Two Different Pole 3 Phase Windings Screen Printed Board, Ms Tube Stands, Acrylic Back Cover , Ac Contactor230v/440V, 16A , Push Button With No/Nc Elements , Proximity Switch , Programmable Logic Controller Kit With Digital Inputs And Outputs Model And Software - Plc Systems With And Software:Micro810 Controller With 8 Digital Inputs And 4 Digital Outputs - 8 Digital Input Switches And 4 Digital Outputs With Led Indication. - 24V Operated, Built-In Power Supply, Additional 5V, 1A Power Supply - 4 No Contacts Of The Relays Connected At Outputs Of The Plc And A Buzzer - Computer Connectivity To Download The Program Using Usb Port With Cable - Professional Programming Component Connect Workbench - Windows 7 Environment - To Write Simple Ladder Logic And Test Using Digital Inputs And Outputs - To Write Simple Ladder Logic And Test Using Timer, Counter, Branching And Subroutines I3 Processor Based System With Windows 8 Os Is To Be Provided By The Institute For Using This Plc , Thermal Overload Relay Timing Characteristics - One No. 3 Phase, 16A Main Contactor - One No. 2-4.5A Overload Relay - Provision To Connect 3 Phase Load Externally - (The Institute Should Provide The Load) - 3 Phase Input, Fuses Wooden Casing , Thermal Overload Relay Timing Characteristics - One No. 3 Phase, 16A Main Contactor - One No. 2-4.5A Overload Relay - Provision To Connect 3 Phase Load Externally - (The Institute Should Provide The Load) - 3 Phase Input, Fuses Wooden Casing , Control Circuit For Semi Automatic Star Delta Starter Suitable For 5 Hp - 3 Nos. Of 440V, 16 A Contactors Main / Star / Delta - Start / Stop / Push Button Switches - Switch For Manual Delay Operation (Semi Automatic) Control Wiring Termination,Powder Coated Ms Stands, Acrylic Back Cover , Control Circuit For Automatic Star Delta Starter Suitable For 5 Hp - 3 Nos. Of 440V, 16 A Contactors Main / Star / Delta - 1 No. Ac Timer (For Automatic Operation) - Start / Stop / Push Button Switches - Switch For Manual Delay Operation (Semi Automatic) Control Wiring Termination,Powder Coated Ms Stands, Acrylic Back Cover , Dynamic Braking Control Of Ac Motor - One 3 Phase, 440V, 16 Amps Main Contactor - One 230V Dc, 12A Contactor For Connecting Dc Supply - Ac Timer, Rectifier For Dc Power Supply, Variac To Be Connected Externally On/Off Push Switches , Two Speed Pole Changing Circuit - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Speed 1, Speed 2 And Stop Push Switches - Provision To Connect Two Different Pole 3 Phase Windings Screen Printed Board, Ms Tube Stands, Acrylic Back Cover , Wire And Test The Control Circuit For Forward And Reverse Operation - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Speed 1, Speed 2 And Stop Push Switches - Provision To Connect Two Different Pole 3 Phase Windings Screen Printed Board, Ms Tube Stands, A , Automatic Rotor Resistance Starter Using Plc Automatic Rotor Resistance Starter Using Plc - To Be Used With Plc And 5Hp 3 Phase Rotor Resistance Induction Motor - Start And Stop Switches - 4 Nos. Of 3 Phase 16A Contactors - Inputs To Plc And Outputs From Plc - Provision To Wire External Resistances In The Rotor Circuit - Institute Has To Provide 9 External Resistances To Be Connected In The Rotor Circuit Provision To Wire Control And Power Wiring - Screen Printed Board, Ms Tube Stands, Acrylic Back Cover B.Starting Resistance 25 Ohms, 9 Nos. ( In 3 Rheostat Form) - To Be Connected To The Rotor Winding Of The Slip Ring Motor - To Be Shorted In 3 Stages At The Time Of Starting , Single Phase Preventer Using Plc - 1 No. 3 Phase 16A Main Contactor - 3 Transformers And Associated Circuits As Input To The Plc - Plc Output As Control Output - 3 Switches To Test The Phase Failure - Proper Termination For 3 Hp Cage Motor Wooden Casing , Plc Based Star Delta Starter Suitable For 5 Hp Motor - 3 Nos. Of 16A, 3 Phase Contactors, - Start And Stop Push Buttons, Fuses And Power Wiring Termination Control Wiring Termination, Powder Coated Ms Stands, Acrylic Back Cover , Automatic Rotor Resistance Starter - 5Hp 3 Phase Rotor Resistance Induction Motor - Start And Stop Switches - 4 Nos. Of 3 Phase 16A Contactors - Inputs To Plc And Outputs From Plc - Provision To Wire External Resistances In The Rotor Circuit - Institute Has To Provide 9 External Resistances To Be Connected In The Rotor Circuit Provision To Wire Control And Power Wiring Screen Printed Board, Ms Tube Stands, Acrylic Back Cover , Lift Working Model - 3 Floors (Ground Plus Two Floors) Sheet Metal Model - Floor Request Switches And Floor Sensing Switches – 6 Inputs To Plc - Cabin – Stepper Motor With Controller/Geared Dc Motorwith Forward And Reverse Control Proper Termination To Wire Inputs And Outputs To Plc , Water Level Controller Working Model - Level Sensors As Input To The Plc - Water Tap As Output From The Plc - Water Pump Motor Control Using Outputs Of The Plc - Water Tank With Sump And Overhead Tank Model - 2 Levels Sensor Switches And 12 V Pump - 24 V Solenoid Valve To Drain Water, 12 V And 24V Power Supply Foot Valve Arrangement To Take The Water From The Sump , Conveyor Working Model - Sloped Conveyor With Shawl Sheet Metal Model - Proximity Sensor To Sense The Shawl - Input To Plc - Start, Stop Push Switches And Fwd / Rev Toggle Switch, Buzzer Output To Give Alarm Conveyor Belt With Geared Dc Motor Drive , Plc Control Circuit For Jogging And Forward – Reverse Operation - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Stop, Start Fwd, Jog Fwd, Start Rev, Jog Rev Push Switches - Inputs For Plc, Control From Outputs Of Plc - Proper Termination For 3 Hp Cage Motor Screen Printed Board, Ms Tube Stands, Acrylic Back Cover => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Supply of EEE Deparment EquipmentItems
Sl. No. Item Description
1Supply of EEE Deparment Equipment NOC Items
2Two speed Pole changing circuit with motor - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover
3AC Contactor230V/440V, 16A
4Push Button with NO/NC Elements
5Proximity switch
6Programmable Logic Controller Kit With digital inputs and outputs Model and software - PLC Systems with and software:Micro810 Controller with 8 digital inputs and 4 digital outputs - 8 Digital input switches and 4 Digital outputs with LED indication. - 24V operated, built-in power supply, additional 5V, 1A Power Supply - 4 NO contacts of the relays connected at outputs of the PLC and a buzzer - Computer connectivity to download the program using USB Port with cable - Professional Programming Component Connect Workbench - Windows 7 Environment - To write Simple Ladder logic and test using digital inputs and outputs - To write Simple Ladder logic and test using timer, counter, branching and subroutines I3 processor based system with Windows 8 OS is to be provided by the institute for using this PLC
7Thermal overload relay timing characteristics - one no. 3 phase, 16A Main Contactor - one no. 2-4.5A Overload relay - Provision to connect 3 phase load externally - (The Institute should provide the Load) - 3 phase input, Fuses Wooden casing
8Thermal overload relay timing characteristics - one no. 3 phase, 16A Main Contactor - one no. 2-4.5A Overload relay - Provision to connect 3 phase load externally - (The Institute should provide the Load) - 3 phase input, Fuses Wooden casing
9Control circuit for Semi automatic Star Delta Starter suitable for 5 HP - 3 nos. of 440V, 16 A Contactors Main / Star / Delta - Start / Stop / Push Button Switches - Switch for manual delay operation (semi automatic) Control wiring termination,Powder Coated MS Stands, Acrylic back cover
10Control circuit for automatic Star Delta Starter suitable for 5 HP - 3 nos. of 440V, 16 A Contactors Main / Star / Delta - 1 no. AC Timer (for automatic operation) - Start / Stop / Push Button Switches - Switch for manual delay operation (semi automatic) Control wiring termination,Powder Coated MS Stands, Acrylic back cover
11Dynamic braking control of AC Motor - One 3 phase, 440V, 16 Amps Main Contactor - One 230V DC, 12A Contactor for connecting DC Supply - AC Timer, Rectifier for DC Power Supply, Variac to be connected externally On/Off Push Switches
12Two speed Pole changing circuit - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover
13Wire and test the control circuit for forward and reverse operation - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, A
14Automatic Rotor Resistance Starter using PLC Automatic Rotor Resistance Starter using PLC - To be used with PLC and 5HP 3 phase Rotor Resistance Induction Motor - Start and Stop Switches - 4 nos. of 3 phase 16A Contactors - Inputs to PLC and outputs from PLC - Provision to wire external resistances in the rotor circuit - Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring - Screen Printed Board, MS tube stands, Acrylic back cover b.Starting resistance 25 Ohms, 9 nos. ( in 3 Rheostat form) - To be connected to the rotor winding of the slip ring motor - To be shorted in 3 stages at the time of starting
15Single Phase Preventer using PLC - 1 no. 3 phase 16A Main Contactor - 3 transformers and associated circuits as input to the PLC - PLC output as control output - 3 switches to test the phase failure - Proper termination for 3 HP cage motor Wooden casing
16PLC based Star Delta Starter suitable for 5 HP Motor - 3 nos. of 16A, 3 phase Contactors, - Start and Stop Push Buttons, Fuses and Power wiring termination Control wiring termination, Powder Coated MS Stands, Acrylic back cover
17Automatic Rotor Resistance Starter - 5HP 3 phase Rotor Resistance Induction Motor - Start and Stop Switches - 4 nos. of 3 phase 16A Contactors - Inputs to PLC and outputs from PLC - Provision to wire external resistances in the rotor circuit - Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring Screen Printed Board, MS tube stands, Acrylic back cover
18Lift working model - 3 floors (Ground plus two floors) sheet metal model - Floor request switches and Floor sensing switches – 6 inputs to PLC - Cabin – stepper motor with controller/geared DC motorwith forward and reverse control Proper termination to wire inputs and outputs to PLC
19Water Level controller working model - Level sensors as input to the PLC - Water tap as output from the PLC - Water Pump motor control using outputs of the PLC - Water Tank with sump and Overhead tank model - 2 Levels sensor switches and 12 V Pump - 24 V Solenoid valve to drain water, 12 V and 24V Power Supply Foot valve arrangement to take the water from the sump
20Conveyor working model - Sloped conveyor with shawl sheet metal model - Proximity sensor to sense the shawl - input to PLC - Start, Stop Push switches and FWD / REV toggle switch, Buzzer output to give alarm Conveyor belt with geared DC Motor drive
21PLC control circuit for jogging and forward – reverse operation - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Stop, Start Fwd, Jog Fwd, Start Rev, Jog Rev Push Switches - Inputs for PLC, Control from outputs of PLC - Proper termination for 3 HP cage motor Screen Printed Board, MS tube stands, Acrylic back cover