Supply Of Eee Lab Items , Supply Of Eee Deparment Equipment Noc Items , Two Speed Pole Changing Circuit With Motor - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Speed 1, Speed 2 And Stop Push Switches - Provision To Connect Two Different Pole 3 Phase Windings Screen Printed Board, Ms Tube Stands, Acrylic Back Cover , Ac Contactor230v/440V, 16A , Push Button With No/Nc Elements , Proximity Switch , Programmable Logic Controller Kit With Digital Inputs And Outputs Model And Software - Plc Systems With And Software:Micro810 Controller With 8 Digital Inputs And 4 Digital Outputs - 8 Digital Input Switches And 4 Digital Outputs With Led Indication. - 24V Operated, Built-In Power Supply, Additional 5V, 1A Power Supply - 4 No Contacts Of The Relays Connected At Outputs Of The Plc And A Buzzer - Computer Connectivity To Download The Program Using Usb Port With Cable - Professional Programming Component Connect Workbench - Windows 7 Environment - To Write Simple Ladder Logic And Test Using Digital Inputs And Outputs - To Write Simple Ladder Logic And Test Using Timer, Counter, Branching And Subroutines I3 Processor Based System With Windows 8 Os Is To Be Provided By The Institute For Using This Plc , Thermal Overload Relay Timing Characteristics - One No. 3 Phase, 16A Main Contactor - One No. 2-4.5A Overload Relay - Provision To Connect 3 Phase Load Externally - (The Institute Should Provide The Load) - 3 Phase Input, Fuses Wooden Casing , Thermal Overload Relay Timing Characteristics - One No. 3 Phase, 16A Main Contactor - One No. 2-4.5A Overload Relay - Provision To Connect 3 Phase Load Externally - (The Institute Should Provide The Load) - 3 Phase Input, Fuses Wooden Casing , Control Circuit For Semi Automatic Star Delta Starter Suitable For 5 Hp - 3 Nos. Of 440V, 16 A Contactors Main / Star / Delta - Start / Stop / Push Button Switches - Switch For Manual Delay Operation (Semi Automatic) Control Wiring Termination,Powder Coated Ms Stands, Acrylic Back Cover , Control Circuit For Automatic Star Delta Starter Suitable For 5 Hp - 3 Nos. Of 440V, 16 A Contactors Main / Star / Delta - 1 No. Ac Timer (For Automatic Operation) - Start / Stop / Push Button Switches - Switch For Manual Delay Operation (Semi Automatic) Control Wiring Termination,Powder Coated Ms Stands, Acrylic Back Cover , Dynamic Braking Control Of Ac Motor - One 3 Phase, 440V, 16 Amps Main Contactor - One 230V Dc, 12A Contactor For Connecting Dc Supply - Ac Timer, Rectifier For Dc Power Supply, Variac To Be Connected Externally On/Off Push Switches , Two Speed Pole Changing Circuit - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Speed 1, Speed 2 And Stop Push Switches - Provision To Connect Two Different Pole 3 Phase Windings Screen Printed Board, Ms Tube Stands, Acrylic Back Cover , Wire And Test The Control Circuit For Forward And Reverse Operation - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Speed 1, Speed 2 And Stop Push Switches - Provision To Connect Two Different Pole 3 Phase Windings Screen Printed Board, Ms Tube Stands, A , Automatic Rotor Resistance Starter Using Plc Automatic Rotor Resistance Starter Using Plc - To Be Used With Plc And 5Hp 3 Phase Rotor Resistance Induction Motor - Start And Stop Switches - 4 Nos. Of 3 Phase 16A Contactors - Inputs To Plc And Outputs From Plc - Provision To Wire External Resistances In The Rotor Circuit - Institute Has To Provide 9 External Resistances To Be Connected In The Rotor Circuit Provision To Wire Control And Power Wiring - Screen Printed Board, Ms Tube Stands, Acrylic Back Cover B.Starting Resistance 25 Ohms, 9 Nos. ( In 3 Rheostat Form) - To Be Connected To The Rotor Winding Of The Slip Ring Motor - To Be Shorted In 3 Stages At The Time Of Starting , Single Phase Preventer Using Plc - 1 No. 3 Phase 16A Main Contactor - 3 Transformers And Associated Circuits As Input To The Plc - Plc Output As Control Output - 3 Switches To Test The Phase Failure - Proper Termination For 3 Hp Cage Motor Wooden Casing , Plc Based Star Delta Starter Suitable For 5 Hp Motor - 3 Nos. Of 16A, 3 Phase Contactors, - Start And Stop Push Buttons, Fuses And Power Wiring Termination Control Wiring Termination, Powder Coated Ms Stands, Acrylic Back Cover , Automatic Rotor Resistance Starter - 5Hp 3 Phase Rotor Resistance Induction Motor - Start And Stop Switches - 4 Nos. Of 3 Phase 16A Contactors - Inputs To Plc And Outputs From Plc - Provision To Wire External Resistances In The Rotor Circuit - Institute Has To Provide 9 External Resistances To Be Connected In The Rotor Circuit Provision To Wire Control And Power Wiring Screen Printed Board, Ms Tube Stands, Acrylic Back Cover , Lift Working Model - 3 Floors (Ground Plus Two Floors) Sheet Metal Model - Floor Request Switches And Floor Sensing Switches – 6 Inputs To Plc - Cabin – Stepper Motor With Controller/Geared Dc Motorwith Forward And Reverse Control Proper Termination To Wire Inputs And Outputs To Plc , Water Level Controller Working Model - Level Sensors As Input To The Plc - Water Tap As Output From The Plc - Water Pump Motor Control Using Outputs Of The Plc - Water Tank With Sump And Overhead Tank Model - 2 Levels Sensor Switches And 12 V Pump - 24 V Solenoid Valve To Drain Water, 12 V And 24V Power Supply Foot Valve Arrangement To Take The Water From The Sump , Conveyor Working Model - Sloped Conveyor With Shawl Sheet Metal Model - Proximity Sensor To Sense The Shawl - Input To Plc - Start, Stop Push Switches And Fwd / Rev Toggle Switch, Buzzer Output To Give Alarm Conveyor Belt With Geared Dc Motor Drive , Plc Control Circuit For Jogging And Forward – Reverse Operation - 2 Nos. Of 3 Phase 16A Main Contactors - 3 Phase Input, Fuses - Stop, Start Fwd, Jog Fwd, Start Rev, Jog Rev Push Switches - Inputs For Plc, Control From Outputs Of Plc - Proper Termination For 3 Hp Cage Motor Screen Printed Board, Ms Tube Stands, Acrylic Back Cover => Limited