Directorate Of Technical Education-DTE has published Tender For Supply Of Eee Lab Items. Submission Date for this Tender is 13-02-2024. Counters Tenders in Thiruvallur Tamil Nadu. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply of EEE Deparment Equipment NOC Items |
2 | Two speed Pole changing circuit with motor - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover |
3 | AC Contactor230V/440V, 16A |
4 | Push Button with NO/NC Elements |
5 | Proximity switch |
6 | Programmable Logic Controller Kit With digital inputs and outputs Model and software - PLC Systems with and software:Micro810 Controller with 8 digital inputs and 4 digital outputs - 8 Digital input switches and 4 Digital outputs with LED indication. - 24V operated, built-in power supply, additional 5V, 1A Power Supply - 4 NO contacts of the relays connected at outputs of the PLC and a buzzer - Computer connectivity to download the program using USB Port with cable - Professional Programming Component Connect Workbench - Windows 7 Environment - To write Simple Ladder logic and test using digital inputs and outputs - To write Simple Ladder logic and test using timer, counter, branching and subroutines I3 processor based system with Windows 8 OS is to be provided by the institute for using this PLC |
7 | Thermal overload relay timing characteristics - one no. 3 phase, 16A Main Contactor - one no. 2-4.5A Overload relay - Provision to connect 3 phase load externally - (The Institute should provide the Load) - 3 phase input, Fuses Wooden casing |
8 | Thermal overload relay timing characteristics - one no. 3 phase, 16A Main Contactor - one no. 2-4.5A Overload relay - Provision to connect 3 phase load externally - (The Institute should provide the Load) - 3 phase input, Fuses Wooden casing |
9 | Control circuit for Semi automatic Star Delta Starter suitable for 5 HP - 3 nos. of 440V, 16 A Contactors Main / Star / Delta - Start / Stop / Push Button Switches - Switch for manual delay operation (semi automatic) Control wiring termination,Powder Coated MS Stands, Acrylic back cover |
10 | Control circuit for automatic Star Delta Starter suitable for 5 HP - 3 nos. of 440V, 16 A Contactors Main / Star / Delta - 1 no. AC Timer (for automatic operation) - Start / Stop / Push Button Switches - Switch for manual delay operation (semi automatic) Control wiring termination,Powder Coated MS Stands, Acrylic back cover |
11 | Dynamic braking control of AC Motor - One 3 phase, 440V, 16 Amps Main Contactor - One 230V DC, 12A Contactor for connecting DC Supply - AC Timer, Rectifier for DC Power Supply, Variac to be connected externally On/Off Push Switches |
12 | Two speed Pole changing circuit - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, Acrylic back cover |
13 | Wire and test the control circuit for forward and reverse operation - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Speed 1, Speed 2 and Stop Push Switches - Provision to connect two different pole 3 phase windings Screen Printed Board, MS tube stands, A |
14 | Automatic Rotor Resistance Starter using PLC Automatic Rotor Resistance Starter using PLC - To be used with PLC and 5HP 3 phase Rotor Resistance Induction Motor - Start and Stop Switches - 4 nos. of 3 phase 16A Contactors - Inputs to PLC and outputs from PLC - Provision to wire external resistances in the rotor circuit - Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring - Screen Printed Board, MS tube stands, Acrylic back cover b.Starting resistance 25 Ohms, 9 nos. ( in 3 Rheostat form) - To be connected to the rotor winding of the slip ring motor - To be shorted in 3 stages at the time of starting |
15 | Single Phase Preventer using PLC - 1 no. 3 phase 16A Main Contactor - 3 transformers and associated circuits as input to the PLC - PLC output as control output - 3 switches to test the phase failure - Proper termination for 3 HP cage motor Wooden casing |
16 | PLC based Star Delta Starter suitable for 5 HP Motor - 3 nos. of 16A, 3 phase Contactors, - Start and Stop Push Buttons, Fuses and Power wiring termination Control wiring termination, Powder Coated MS Stands, Acrylic back cover |
17 | Automatic Rotor Resistance Starter - 5HP 3 phase Rotor Resistance Induction Motor - Start and Stop Switches - 4 nos. of 3 phase 16A Contactors - Inputs to PLC and outputs from PLC - Provision to wire external resistances in the rotor circuit - Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring Screen Printed Board, MS tube stands, Acrylic back cover |
18 | Lift working model - 3 floors (Ground plus two floors) sheet metal model - Floor request switches and Floor sensing switches – 6 inputs to PLC - Cabin – stepper motor with controller/geared DC motorwith forward and reverse control Proper termination to wire inputs and outputs to PLC |
19 | Water Level controller working model - Level sensors as input to the PLC - Water tap as output from the PLC - Water Pump motor control using outputs of the PLC - Water Tank with sump and Overhead tank model - 2 Levels sensor switches and 12 V Pump - 24 V Solenoid valve to drain water, 12 V and 24V Power Supply Foot valve arrangement to take the water from the sump |
20 | Conveyor working model - Sloped conveyor with shawl sheet metal model - Proximity sensor to sense the shawl - input to PLC - Start, Stop Push switches and FWD / REV toggle switch, Buzzer output to give alarm Conveyor belt with geared DC Motor drive |
21 | PLC control circuit for jogging and forward – reverse operation - 2 nos. of 3 phase 16A Main Contactors - 3 phase input, Fuses - Stop, Start Fwd, Jog Fwd, Start Rev, Jog Rev Push Switches - Inputs for PLC, Control from outputs of PLC - Proper termination for 3 HP cage motor Screen Printed Board, MS tube stands, Acrylic back cover |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail