Replacement Of Unserviceable Light Fittings, Led Flood Lights And Underground Cable With Lt Feeder Pillar To Community Centre-I At Newtown, Kolkata., newtown-West Bengal

New Town Kolkata Development Authority-NKDA has published Replacement Of Unserviceable Light Fittings, Led Flood Lights And Underground Cable With Lt Feeder Pillar To Community Centre-I At Newtown, Kolkata.. Submission Date for this Tender is 13-02-2024. Electrification Work Tenders in newtown West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42060414
Replacement Of Unserviceable Light Fittings, Led Flood Lights And Underground Cable With Lt Feeder Pillar To Community Centre-I At Newtown, Kolkata.
Open Tender
Indian
West Bengal
newtown
13-02-2024

Tender Details

Replacement Of Unserviceable Light Fittings, Led Flood Lights And Underground Cable With Lt Feeder Pillar To Community Centre-I At Newtown, Kolkata.- 1 Supply And Fixing Hi-Effucency Round Led High Bay Luminarie With Aluminium Die-Cast Housing ( Round Shape ) With High Level Protection Against Corrosion, Lens Technology Ensures High Performance Photometry, Soft Light No Glareof 90 Watt Capacity , Ip-66 Protection , Cct 5700Ac 120-300 Volt, 50 Hz, Including Taking Down Unserviceable Fittng And Making Necessary Connection With Suitable Size Copper Wire All As Directed By Eic. ( Make : Magik / Havells / Orient ) 2 Supply & Fixing High Efficiency Led Flood Light Of Capacity 60 Watt , Ip-66 Protection, Ac 120-300 Volt, 50 Hz With Pressure Die-Cast Aluminium Housing In Rectangle Shape And Toughened Glass In The Front , Including Taking Down Unserviceable Fittng And Making Necessary Connection With Suitable Size Copper Wire All As Directed By Eic. ( Make : Orient / Havells / Magik ) 3 Laying Of One No. Cable Above 35 Sqmm And Upto 185 Sqmm In Underground Trench 460Mm Wide X 760Mm Average Depth, With Brick Protection On The Top Of The Cable With 8 ( Eight ) Nos. Bricks Per Mtr. Including Filling The Space Between The Bricks And Cable And Also The Trenchwith Shifted Soil, Leveling Up And Restoring Surface Duly Rammed 4 Laying Of Cable As Below, After Cutting Floor / Pavement / Wall / And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish Upto 95 Sqmm At An Average Depth Of 100Mm In Floor / Pavement / Wall Etc. 5 Laying Of Cable From 3 / 3½ Core 35 Sqmm To 50 Sqmm On Wall / Surface Incl. S & F Ms Saddles With Earthing Attachment In 2 X 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy., Mending Good Damages And Painting 6 Supplying Xlpe Insulated Unarmoured Aluminium Cable 1.1 Kv Gradeof Size 50 Sqmm 3.5 Core. Make : Polycab / Havells / Kei. 7 Supplying & Fixing Medium Gauge Gi Pipe 50Mm Dia ( Isi-Medium ) Protection With Necessary Fittings And Jointing Metarials As Required. Make : Jindal / Tata 8 Supply And Fixing Commissioning And Testing Of Feeder Pillar Box Out Door Type, Of Size 1500 ( L ) X 1200 ( H ) X 500 Mm, Made Out Of 3.15Mm Thick Ms Sheet On Equal Angle Of Size 25 X 25 X 5 Mm Thick, Powder Coating Paint ( 5 Stage Tank Process ) , To Be Fixed On Pcc Platform ( 50 Cm Clearance To Be Provided Between Lt Panel And Pcc Platform ) , Following To Be Fixed In Feeder Pillar :- ( A ) Mccb, 415 V, 100 Amp , Four Poleof Breaking Capacity 25Ka / 35Ka With Fixed Thermal And Fixed Magnetic / Adjustable Thermal And Fixed Magnetic Setting. - 01 Nos ( As Incommer ) . Make Of Mccb / Mcbs : Legrand / Schneider / Havells. ( B ) Mcb 63 Amp, Tpn 415 Vol, Breaking Capacity 10 Ka - 01 No ( Out Going ) ( C ) Mcb 40 Amp, Tpn 415 Vol, Breaking Capacity 10 Ka - 02 No ( Out Going ) ( D ) Ammeter 0-100A With Selecctor Switch - 01 Nos ( Make : Ae / L&T ) ( E ) Voltmeter With Selector Switch - 01 Nos ( Make : Ae / L&T ) . ( F ) Indicator Switch R Y B - 01 Set ( G ) Aluminium Bus Bar Of Size 25 X 6 Mm, 50 Cm Long = 4 Nos , Duly Connected With Suitable Size Of Copper Wire Single Core With Copper Thimble. Bus Bar Is Required To Be Fitten On Pvc Insulators All As Required And Directed By Eic. 9 Earthing With 50 Mm Dia Tata Gi Pipe Medium Grade 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi ( Hot Dip ) Wire ( 4 Mts. Long ) , 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection ( 1 Mts. Long ) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level. 10 Supplying And Fixing 240 / 415 V Mcb Sp 6-32 A Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. Make : Legrand / Schneider / Havells. 11 Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe / Pvc Armoured Cable Of Size 50 Sqmm 3.5 Core.

Key Value

Document Fees
Refer document
EMD
INR 4000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: “Replacement of unserviceable light fittings, LED Flood lights and underground cable with LT feeder pillar to Community Centre-I at Newtown, Kolkata.”
Sl. No. Item Description
1Supply and fixing Hi-effucency round LED high bay luminarie with aluminium die-cast housing (Round shape) with high level protection against corrosion, lens technology ensures high performance photometry, soft light no glareof 90 watt capacity , IP-66 protection ,CCT 5700AC 120-300 volt, 50 Hz,including taking down unserviceable fittng and making necessary connection with suitable size copper wire all as directed by EIC. (Make : Magik/Havells/Orient)
2Supply & Fixing High efficiency LED flood light of capacity 60 Watt , IP-66 protection, AC 120-300 Volt, 50 Hz with pressure die-cast aluminium housing in rectangle shape and toughened glass in the front , including taking down unserviceable fittng and making necessary connection with suitable size copper wire all as directed by EIC.(Make : Orient/Havells/Magik)
3Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
4Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish upto 95 sqmm at an average depth of 100mm in floor/pavement/wall etc.
5Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
6Supplying XLPE insulated unarmoured aluminium cable 1.1 kv gradeof size 50 sqmm 3.5 core. Make : Polycab/Havells/KEI.
7Supplying & fixing medium gauge GI Pipe 50mm dia( ISI-Medium) Protection with necessary fittings and jointing metarials as required. Make : JINDAL/TATA
8Supply and fixing commissioning and testing of feeder pillar box out door type, of size 1500 (L) x 1200 (H) x 500 mm, made out of 3.15mm thick MS Sheet on equal angle of size 25 x 25 x 5 mm thick, powder coating paint ( 5 stage tank process), to be fixed on PCC platform (50 Cm clearance to be provided between LT Panel and PCC Platform), following to be fixed in feeder pillar :-(a) MCCB,415 V, 100 Amp , Four Poleof Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting. - 01 Nos (As incommer). Make of MCCB/MCBs : Legrand/Schneider/ Havells.(b)MCB 63 Amp, TPN 415 Vol, Breaking capacity 10 KA - 01 No (Out going)(c)MCB 40 Amp, TPN 415 Vol, Breaking capacity 10 KA - 02 No (Out going)(d)Ammeter 0-100A with selecctor switch - 01 Nos (Make : AE/L&T)(e)Voltmeter with selector switch - 01 Nos (Make : AE/L&T).(f)Indicator switch R Y B - 01 Set (g) Aluminium bus bar of size 25 x 6 mm, 50 cm long = 4 Nos ,duly connected with suitable size of copper wire single core with copper thimble. Bus bar is required to be fitten on PVC insulators all as required and directed by EIC.
9Earthing with 50 mm dia TATA GI pipe medium grade 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
10Supplying and fixing 240/415 V MCB SP 6-32 A of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Make : Legrand/Schneider/Havells.
11Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cable of size 50 sqmm 3.5 core.
Disclaimer :