Construction Of H.L. Bridge Across Seaback Water At 1/230 Km On The R/F Burjapadu To Pl Puram Via Donkuru In Ichapuram Mandal Of Srikakulam District Est. Cost Rs.630.00 Lakhs (Maintenance Cost Rs.17.33 Lakhs) Package,No. Ap18piiilsb 03, mandal-Andhra Pradesh

Panchayat Raj Department has published Construction Of H.L. Bridge Across Seaback Water At 1/230 Km On The R/F Burjapadu To Pl Puram Via Donkuru In Ichapuram Mandal Of Srikakulam District Est. Cost Rs.630.00 Lakhs (Maintenance Cost Rs.17.33 Lakhs) Package,No. Ap18piiilsb 03. Submission Date for this Tender is 20-02-2024. Bridge Work Tenders in mandal Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42055328
Construction Of H.L. Bridge Across Seaback Water At 1/230 Km On The R/F Burjapadu To Pl Puram Via Donkuru In Ichapuram Mandal Of Srikakulam District Est. Cost Rs.630.00 Lakhs (Maintenance Cost Rs.17.33 Lakhs) Package,No. Ap18piiilsb 03
Open Tender
Indian
Andhra Pradesh
mandal
20-02-2024

Tender Details

Construction Of H.L. Bridge Across Seaback Water At 1 / 230 Km On The R / F Burjapadu To Pl Puram Via Donkuru In Ichapuram Mandal Of Srikakulam District Est. Cost Rs.630.00 Lakhs ( Maintenance Cost Rs.17.33 Lakhs ) Package, No. Ap18piiilsb 03

Key Value

Document Fees
Refer document
EMD
INR 922000.0 /-
Tender Value
INR 4.46 Crore /-

BOQ Items

Name of Work: Construction of H.L.B across Seaback water at 1/230 Km on The R/f Burjapadu to PL Puram via Donkuru in Ichapuram mandal of Srikakulam District Est. Cost Rs.630.00 lakhs (Maintenance cost Rs.17.33 Lakhs) Package,No. AP18PIIILSB 03
Sl. No. Item Description
1BridgePortion
2Bored cast-in-situR.C.C pile1200 mm dia withM 35 gradedesign mix using 40mm, 20mm 10mm HBGmetal mechanically mixedexcluding Reinforcement etc complete as per Drawing and Technical Specifications in Section 1100 & 1700 MORTH and removal of excavated earth with all lifts and lead upto 1000 m, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
3Providing concrete for plain/reinforced concrete in open foundations using 40,20 & 10 mm nominal size Graded hard stone aggregate, mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH.including contractors profit & Over head charges but excluding GST , seignorage charges etc complete ,
4Reinforced Concrete concrete M35 gradeDesign Mixusing 20mm , 10mm HBG metal Machine mixing in Pile Cap complete as per Drawing and Technical Specifications in Section 1100, 1500 & 1700 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
5Reinforced cement concrete M35 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1206 MORD and 1500, 1700 & 2200 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete (upto 5m height)
6Reinforced cement concrete M35 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 MORD and 1500, 1700 & 2200 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete ( 5 to 10m height)
7Providing and laying reinforced cement concrete M35 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 MORD / Sections 1500, 1600 & 1700 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete 5 to 10m height. For Super strcuture
8Providing and laying cement concrete wearing course M 30 (Design Mix) grade using 20 & 10mm metal (HBG) mechanically mixed excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1404.2.2 MORD and 2702 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete-
9Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202MORD & 1100, 1600 MORTH for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including contractors profit & Over head charges, but excluding GST etc., complete - For Foundation
10Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1001 & 1206 MORD / Sections 1600 & 2200 MORTH for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including contractors profit & Over head charges, but excluding GST etc., complete- For Sub Structures - For Sub Structures
11Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1001 and 1401 MORD / 1600 MORTH, for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including contractors profit & Over head charges, but excluding GST etc., complete - For Super Structures
12Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 MORD / 710.14 of IRC, 78 & 2200 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
13Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 MORD / 2706 & 2200 MORTH including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
14Elastomeric bearing assembly consisting of 7 layers of elastomer bonded to 6 nos. internal reinforcing steel laminates by the process of vulcanisation, complete with all components as per drawing and Technical Specifications.
15providingand fixingGalvanized Drainage Spoutsalong with drinage pipes complete as per drawing and Technical specification as perClause 1209 MORD & 2705 MORTH including overhead charges and contractors profit but excluding GST.
16Providing and constructing one span service road to reach island location from one pier location to another pier location as per Tech. Specification 1203 MORTH.
17Providing and laying of compression seal joint consisting of steel armoured nosing at two edges of the joint gap suitably anchored to the deck concrete and a preformed chloroprene elastomer or closed cell foam joint sealer compressed and formed into the joint gap with special adhesive binder to cater for a horizental movement upto 40mm and vertical movement of 3 mm as per drawing and Technical Specification Clause 1207.2.4 / 2600 MORTH,including over heads and & contractors profit, all other taxes excluding GST and seinorage charges
18Providing MS Steel Liner of 6mm thick for Piles including fabricating and setting out as per detailed drawing and as per MORTH specifications 1200 & 1900 including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
19Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including dewatering, contractors profit & Over head charges, but excluding GST and seigniorage etc., complete- For Foundations
20Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head wall and parapets. Tech Specification Clause 1101.6 MORD ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete - For Pipe Culverts
21Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 MORD / 710.14 of IRC, 78 & 2200 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
22Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701MORD. including contractors profit & Over head charges, but excluding GST etc., complete
23Reinforced Cement Concrete M 35 grade approach slab using 20 & 10mm metal (HBG) mechanically mixed excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1211 MORD / 1500, 1600, 1700 & 2704 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
24Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-35 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified including cost of steel bu excluding GST and seignorage charges etc complete
25Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting with vibratory roller 80-100 KN to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 MORDincluding contractors profit & Over head charges, but excluding GST and Seigniorage chargesetc., complete.., complete.
26Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202 MORD / MORTH,including contractors profit & Over head charges, but excluding GST etc., complete.
27Construction of RCC guide posts of 250 mm dia M 20 grade cast-in-situ with 20 mm nominal size aggregate (HBG), true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
28Road Portion
29Construction of granular sub-baseby providing well graded material(Table 400.1-A) with Grading IIIMaterial(HBG M/C +Stone dust)CBR Value not less than20 andPI Value less than 6spreading in uniform layers with Tractor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting withVibratory Roller to achieve thedesired density, complete as per Technical Specification Clause 401 MORD including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete.
30Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with Vibratory Roller 80-100 kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406 MORD, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
31Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 MORD (for use on Wet mix macadam & WBM) ,including contractors profit & Over head charges, but excluding GST etc., completefor Prime Coat
32Providing and applying tack coat with Bitumen emulsion (RS-1)using emulsiondistributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 MORD, including contractors profit & Over head charges, but excluding GST etc., completefor Tack Coat
33Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates (Table 500.13) either using penetration grade bitumen VG30 grade at the rate of 14.6 kg/10 sqm to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a Hot Mix plant of 30-40TPH, laying and rolling with a three wheel 0-100 kN static roller capacity, paver finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C including cost and conveyance of all materials from approved sources, , labour charges and hire and operational charges of power road roller and all other machinery, tools and plants, providing barricading for diversion of traffic, erecting red flags other incidental and operational charges etc., complete for finished item of work as per clause 506 MORD"2014 including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete using HMP
34Providing and laying bituminous premixed seal coat (Type C) comprising of stone chipping of grading as defined in table 500.16 of MOST with Crushed stone chips of 6.7 mm size 100% passing through 9.5mm seive and retained on 2.36 mm sieve applied @ 0.09 cum per 10 sqm, chips to be premixed by mechanical means .with the bitumunous binder using 6.50 kgs of bitumen VG 30 grade for 10 sqm and rolling with power roller including of required line, level, grade to serve as wearing course on previously prepared surface and finishing to required level and grades including cost and conveyance of all materials from approved sources and stacking at site to departmental gauge forpremeasurements, labour charges and hire and operational charges of power road roller 8 to 10 tonnes capacity and all other machinery, tools and plants, providing barricading for diversion of traffic, erecting red flags other incidental and operational charges etc., complete for finished item of work as per technical specification clause 508 of MORD"2014 including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for seal coat.By Mechanical Means
35Construction of Shoulders by providing selected earth having minimum CBR of 10%, MDD not less than 1.85 g/cc with LL & PI not more than 40% and 20 respectivelyand spreading in uniform layers with tractor grader on prepared surface, and compacted at OMC withvibratory roller 80-100 kN to meet requirement of Table 300.2 with as per Technical Specification Clause 303 & 407 MORD, by using machinery including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete.
36Protection works and appron and pitching
37Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including dewatering, contractors profit & Over head charges, but excluding GST and seigniorage etc., complete- For Foundations
38Providing concrete for plain concrete M 10grade in open foundations using 40 mm nominal size hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete For levelling course
39Reinforced cement concrete M20 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in foundations complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 MORD and 1500, 1700 & 2200 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
40Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head wall and parapets. Tech Specification Clause 1101.6 MORD ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete - For Pipe Culverts
41Road Furniture
42Providing & fixing of typical PMGSY informatory sign board with LOGO as per MORD secifications and drawing.Three Alluminium Composite Material as per Drawings, top and middle plate duly welded with MS flat iron 25mmx5mm size on black on edges.The lower plate will be welded with MS angle iron frame of lower most plate and flate iron frame of middle plate will be welded to 2 nos 75mmx75mm of 12 SWG sheet tubes posts duly embedded in CC M15 grade blocks of 450mmx450mmx600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mmx47mm of 12 SWG sheet plate tube.All MS will be stove enmeled on both sides.Lettering and paining of superior quality in required shede and colour.All sections of framed posts and sheet tube will be painted with primer and two coats of epoxy paint as per drawing clause 1701 and annexure 1700.1 if MORD including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete
43Providing and erecting direction and place identification retro-refectorised sign as per IRC:67 made of encapsulated lens type refective type sheeting vide clause 1701.2.3 MORD fixed over aluiminium sheeting,2 mm thick with area not exceeding 0.90 sqm supported on mild steel iron posts 75x75x6 mm firmly fixed to ground by means of propoerly designed foundation with M15 grade cement concrete 450x450x600 mm with 2 nos of Hold fasts of size 50mmx6mm MS angles ,600 mm below groud level as per drawings and technical specification clause 1701 MORD including cost and conveyance of all materials, all labour charges, over head charges & Contractors Profit but excluding GST and seigniorage charges etc., complete for finished item of work.
44Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 MORD fixed over aluminium sheeting 1.50 mm thick supported on a mild steel iron post 75mmx75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M15 cement concrete 450mm x450mmx600 mm,with 2 nos of Hold fasts og size 50mmx6mm MS angles 600 mm below ground level as per drawings and technical specification clause 1701 MORD including cost and conveyance of all materials, all labour charges, over head charges & Contractors Profit but excluding GST and seigniorage charges etc., complete for finished item of work.
45Cost & supply of Guard Stones ( 1200 x 200 x 200 mm) including overheads & contractor"s profit and VAT
46Supply and Installation of Hazard Markers using M.S. Angle of size 55X55X6mm and 120 cm high above ground level painted with two coats of black & white stripes of 15cm wide with first quality synthetic enamel paint over one coat of appropriate primer of approved brand, colour, with 30cm X 90cm retro reflective sheeting type III/IV of yellow colour fixed at top over 1.5mm aluminium sheet with standard supports consisting of alternately black and yellow stripes, with black stripes in screen printing sloping downward at an angle of 45degree towards the side of the obstruction on which the traffic is pass and buried in to the ground in a trench of size 30cm X 30cm, and 50cm depth filled with CC 1:2:4 including cost and conveyance of all materials, equipment, machinery and labour with all lead and lifts, loading and unloading charges necessary for successful completion of works as directed by the Engineer-in-Charge and conforming to IRC 79-1981 & MoRTH specification no. 805 and approved drawings etc., complete for finished item of work including cost and conveyance of all materials, all labour charges, over head charges & Contractors Profit but excluding GST and seigniorage charges etc., complete for finished item of work.
47Pavement markings with hot line applied Thermo plastic compound 2.50 mm thick including reflecting glass beads at 250 gms/sqm, thickness of 2.5mm is exclusive of surface applied glass beads for providing centerline marking 300 cms length and 10cm width with a gap of 450 cms including cost and convenyace of all materialsequipment machinary and labour with all leads and lifts loading and unloading charges necessary for sucessful completion of work as directed by the Engineer-in-Charge and confirming to IS 164 - 1981 (1st revison reaffirmed in 1986) and clause 803 of MOST specification for roads and bridge works and also confirming to IRC 35 -1997 including cost and conveyance of all materials, all labour charges, over head charges & Contractors Profit but excluding GST and seigniorage charges etc., complete for finished item of work.
48Supplying & Fixing of Moulded Shanks Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No. RW/NH/33023/10-97 – DO III Dt 11.06.1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the twin shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the Engineer-in-Charge including cost and conveyance of all materials, all labour charges.
49Providing and fixing of Citizen informationboard as per MoRD specifications and drawings. as per IRC:67 made oftype Retro reflective sheeting vide Clause 1701.2.3 MORD / 801.3 MORTHfixed over Alluminium Composite Material of 4 mm thickness consisting of 2 boardsof size750 x 900 mmon a frames made up of 25X25X5mm thick MS angles and welded toMS flat Iron plates 75 x 5 mm size on back and welded to 75 mm x 75mm x6mm MS hallow squar tube frame of height 3.05m as per the drawing and painted with ready mixed syntheticenamel paint of superiorquality in required shade and colour, lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications. The 75mm x75mmx6mm hallow sqareMS tubes welded with 50 x 50x 6 mm angle iron hold fasts of 300 mm long at bottom ( 2no for each leg)and painted with primer and two coats of epoxypaint and embedded in to cement concrete M15 grade of size 600 x 600 x 750 mm, 600 mm below ground level as per MoRD specifications clause 1701 including over head charges & contractors profit but excluding GST & Seigniorage charges etc., complete.
50Providing and fixing of Maintenance information board as per IRC:67 made oftype Retro reflective sheeting vide Clause 1701.2.3 MORD / 801.3 MORTHfixed over Alluminium Composite Material of 4mm thicknessof size of 900 x 1500 mmon a frame made up of 25X25X6mm thick MS anglesand welded toMS flat Iron plates 75 x 5 mm size on back and welded to 75 mm x 75mm x 6mm MS hallow squar tube frame of height 3.00m as per the drawing and painted with ready mixed syntheticenamel paint of superiorquality in required shade and colour, lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications.The 75mm x75mmx6mm hallow sqareMS tubes welded with 50 x 50x 6 mm angle iron hold fasts of 300 mm long at bottom ( 2no for each leg)and painted with primer and two coats of epoxypaint and embedded in to cement concrete M15 grade of size 600 x 600 x 750 mm, 600 mm below ground level as per MoRD specifications clause 1701 including over head charges & contractors profit but excluding GST & Seigniorage charges etc., complete.
Disclaimer :