Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Section I |
| 2 | Building Work (Barrack 1&2) |
| 3 | DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 4 | DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 5 | 12.51.1Ridges plain (500 - 600mm) |
| 6 | 12.51.6Gutter (600 mm over all girth) |
| 7 | 5.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 9 | 5.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 10 | DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 11 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete. |
| 12 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 13 | 12.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing. |
| 14 | DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia |
| 15 | 12.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . |
| 16 | 12.42.5.2Bend 110mm |
| 17 | 12.42.6.2Shoe 110 mm |
| 18 | 12.42.1.2Coupler 110 mm |
| 19 | DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 20 | 12.43.2110 mm |
| 21 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 22 | (a) Bricks (1+25) = 26 |
| 23 | (b) Coarse Sand(1+9=10 Km ) |
| 24 | (c) Cement (40 Km ) |
| 25 | Building Work (Barrack 3) |
| 26 | DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 27 | DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 28 | 12.51.1Ridges plain (500 - 600mm) |
| 29 | 12.51.6Gutter (600 mm over all girth) |
| 30 | 5.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 31 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 32 | 5.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 33 | DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 34 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete. |
| 35 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 36 | 12.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing. |
| 37 | DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia |
| 38 | 12.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . |
| 39 | 12.42.5.2Bend 110mm |
| 40 | 12.42.6.2Shoe 110 mm |
| 41 | 12.42.1.2Coupler 110 mm |
| 42 | DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 43 | 12.43.2110 mm |
| 44 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 45 | (a) Bricks (1+25) = 26 |
| 46 | (b) Coarse Sand(1+9=10 Km ) |
| 47 | (c) Cement (40 Km ) |
| 48 | Building Work (Barrack 4,5,6 &7) |
| 49 | DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 50 | DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 51 | 12.51.1Ridges plain (500 - 600mm) |
| 52 | 12.51.6Gutter (600 mm over all girth) |
| 53 | 5.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 54 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 55 | 5.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 56 | DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 57 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete. |
| 58 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 59 | 12.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing. |
| 60 | DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia |
| 61 | 12.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . |
| 62 | 12.42.5.2Bend 110mm |
| 63 | 12.42.6.2Shoe 110 mm |
| 64 | 12.42.1.2Coupler 110 mm |
| 65 | DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 66 | 12.43.2110 mm |
| 67 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 68 | (a) Bricks (1+25) = 26 |
| 69 | (b) Coarse Sand(1+9=10 Km ) |
| 70 | (c) Cement (40 Km ) |
| 71 | Building Work (Kitchen) |
| 72 | DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 73 | DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 74 | 12.51.1Ridges plain (500 - 600mm) |
| 75 | 12.51.6Gutter (600 mm over all girth) |
| 76 | 5.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 77 | 5.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 78 | 5.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 79 | DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 80 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete. |
| 81 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 82 | 12.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing. |
| 83 | DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia |
| 84 | 12.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . |
| 85 | 12.42.5.2Bend 110mm |
| 86 | 12.42.6.2Shoe 110 mm |
| 87 | 12.42.1.2Coupler 110 mm |
| 88 | DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 89 | 12.43.2110 mm |
| 90 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 91 | (a) Bricks (1+25) = 26 |
| 92 | (b) Coarse Sand(1+9=10 Km ) |
| 93 | (c) Cement (40 Km ) |
| 94 | Electrical Barrack -1 |
| 95 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell\"s/Polycab/Finolex/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / C&S/ Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:Havell\"s/L&T/Legrand/Schneider/C&S (6)XLPE/PVC aramoured cable:-Havell\"s/Polycab/V-guard/Finolex (7) LED FTTING FIXTURE -: Havells/Bajaj/Crompton/C&S (Model/as per E/I ) (8) CEILING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha(Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Surya/Valmont/RR Ispat/Transrail(10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Mahindra |
| 96 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 97 | 1.3.2Group B |
| 98 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 99 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 100 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 101 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 102 | 1.7.42x6.0 sq mm+1x6.0 sq mm earth wire |
| 103 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 104 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 105 | 1.24.15/6 amps, one way switch |
| 106 | 1.24.315/16 amps, one way switch |
| 107 | 1.24.45/6amps, 3 pin socket outlet |
| 108 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 109 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 110 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 111 | 1.27.36 module(78mm x 205mm x 50mm) |
| 112 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 113 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 114 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 115 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 116 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 117 | 1.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 118 | 2.1S/F rewireble double pole/TP&N switch disconector:-Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required. |
| 119 | 2.1.563 amps, TP&N |
| 120 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 121 | 2.8.88 Way,Double door |
| 122 | 2.8.1016 Way,Double door |
| 123 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 124 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 125 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 126 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 127 | 2.12.640 amps ,DP |
| 128 | 2.12.750/63 amps, DP |
| 129 | 2.12.1050/63 amps, TPN |
| 130 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 131 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 132 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 133 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 134 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 135 | M-74016 sq.mm. 4 core |
| 136 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 137 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 138 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 139 | CODE No. M - 774Providing of 9\"\" (230 mm) Metal exhaust fan of make bajaj/havells/usha/crompton |
| 140 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 141 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 142 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 143 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 144 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 145 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 146 | 9.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S |
| 147 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 148 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 149 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 150 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 151 | Electrical Barrack -2 |
| 152 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 153 | 1.3.2Group B |
| 154 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 155 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 156 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 157 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 158 | 1.7.42x6.0 sq mm+1x6.0 sq mm earth wire |
| 159 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 160 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 161 | 1.24.15/6 amps, one way switch |
| 162 | 1.24.315/16 amps, one way switch |
| 163 | 1.24.45/6amps, 3 pin socket outlet |
| 164 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 165 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 166 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 167 | 1.27.36 module(78mm x 205mm x 50mm) |
| 168 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 169 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 170 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 171 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 172 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 173 | 1.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 174 | 2.1S/F rewireble double pole/TP&N switch disconector:-Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required. |
| 175 | 2.1.563 amps, TP&N |
| 176 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 177 | 2.8.88 Way,Double door |
| 178 | 2.8.1016 Way,Double door |
| 179 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 180 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 181 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 182 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 183 | 2.12.640 amps ,DP |
| 184 | 2.12.750/63 amps, DP |
| 185 | 2.12.1050/63 amps, TPN |
| 186 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 187 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 188 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 189 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 190 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 191 | M-74016 sq.mm. 4 core |
| 192 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 193 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 194 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 195 | CODE No. M - 774Providing of 9\"\" (230 mm) Metal exhaust fan of make bajaj/havells/usha/crompton |
| 196 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 197 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 198 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 199 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 200 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 201 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 202 | 9.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S |
| 203 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 204 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 205 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 206 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 207 | Electrical Barrack -3 (Store, Feeder, Panel & Street Lighting.) |
| 208 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 209 | 1.3.2Group B |
| 210 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 211 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 212 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 213 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 214 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 215 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 216 | 1.24.15/6 amps, one way switch |
| 217 | 1.24.315/16 amps, one way switch |
| 218 | 1.24.45/6amps, 3 pin socket outlet |
| 219 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 220 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 221 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 222 | 1.27.36 module(78mm x 205mm x 50mm) |
| 223 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 224 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 225 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 226 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 227 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 228 | 2.1S/F rewireble double pole/TP&N switch disconector:-Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required. |
| 229 | 2.1.432 amps, TP&N |
| 230 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 231 | 2.9.44 way (4+12),Double door, Horizontal type |
| 232 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 233 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 234 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 235 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 236 | 2.12.86/32 amps,TPN |
| 237 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 238 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 239 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 240 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 241 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 242 | M-73910 sq.mm. 4 core |
| 243 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 244 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 245 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 246 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 247 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 248 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 249 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 250 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 251 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 252 | 9.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S |
| 253 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 254 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 255 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 256 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 257 | FEEDER PILLER AND MAIN CABLE TO TRANSFORMER & STREET LIGHT |
| 258 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 259 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 260 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 261 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 262 | 2.19P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required. |
| 263 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 264 | 3.6Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke) |
| 265 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 266 | 3.8S/L 6 SWG G.I. wire ground :-Supplying and laying 6 SWG G.I. wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 267 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. For Barrack 8,9 &10 |
| 268 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. For strret light |
| 269 | 5.3Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 95 sq.mm. but not exceeding 185 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 270 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 271 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 272 | M-74016 sq.mm. 4 core for barrack 8,9 &10 |
| 273 | M-74016 sq.mm. 4 core for street light |
| 274 | M-332150 sq.mm. 3.5 core |
| 275 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 276 | 12.38 DSRSupplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 277 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 278 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 279 | 9.2S.I.T.C of following rating LED FLOOD lighting with pressure dia cast housing and toughened glass cover (IP 66 protection)in existing pole/pipe /platform/periferial wallfor supply voltage 100-270v AC,50Hz Luminire shall be confirmto IS-10322 part-5/ section-3 and shall be complete with all neccssary accessories as required.of make bajaj/havells/crompton/C&S |
| 280 | 9.2.5120 W LED FLOOD LIGHT of make bajaj/havells/crompton/C&S |
| 281 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 282 | 9.1.790 /100 W LED Street light of make bajaj/havells/crompton/C&S |
| 283 | Code no. M-742Supply of 7 Mtr height Octagonal Hot Dip Galvenized pole (BOP - 7030) with top dia 70 mm, bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12mm (L X B X T) including suitable sizes of foundetion bolt all complete as requried. (Without Arm) |
| 284 | Code no. M-7581.5 Mtr Single Arm suitable for 70 mm TOP |
| 285 | Code no. M-875Instalation Testing & Commisioning of 7 Mtr Octagonal Pole & light fitting with the help of tools & plants, wiring of luminaires with all materials and construction of shallow foundetion with M 25 grade concreat considering safe soil bearing capacity of 10T/Mtrs sq |
| 286 | LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMINGwith following: |
| 287 | INCOMING |
| 288 | (a) M - 322315 amps, 35 KA Adjestable thermal seting |
| 289 | (b) M -584160A changover FP Open excution type With rootary handle (ON-LOAD) |
| 290 | (C) M - 620400A TPN BUSBAR(COPPER) |
| 291 | OUTGOING |
| 292 | (d)M - 31825/100 amps, 16 KA fixed thermal seting |
| 293 | (g) 2.12.332 amps.SPN MCB |
| 294 | OTHER ACCESSOSRIES |
| 295 | (j) Code no. M- 873 ADIGITAL VOLT METER 500V(3phase class 0.5) |
| 296 | (k) Code no. M- 873 BDIGITAL A METER 500V(3phase class 0.5) |
| 297 | (l) Code no. M- 445COPPER WIRE 1.5MM |
| 298 | (m) Code no. M- 448COPPER WIRE 6MM |
| 299 | (n) Code no. M- 449COPPER WIRE 10MM |
| 300 | (o) Code no. M- 451COPPER WIRE 25MM |
| 301 | (p) Code no. M- 1455LED INDICATOR LAMP R/Y/B/G |
| 302 | (q) Code no. M- 1452C.T COIL OF CT ratio 500/5 IS2705 part -3 |
| 303 | Anaylised & ApprovedLT PANEL(Waterproof):-Supplying,Fixing, Designing, Cmmisioning, Manufactored Double Door LT Panel fabricated out of 1.626 mm thick(16SWG) CRCA sheet steel, dust and vermin proofwith reinforcement of suitable size iron channel, size 75mmx75mmx6mm with proper lifting arrangement effecting proper connection of all incomer and out going (IP-66) fully compartmentalized cubical type (folded joints construction), wall floor mounted, totally enclosed, extendable on both sides, switch board and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having 36 KA fault capacity, housed with incoming,Steel Stand, interconnection, interlocking between feeders etc. space for 3 phase Energy meter 1 nos,as required.The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized cubical panel, 2 Nos. earth studs. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.The pannel shall be interlocked with switchgear.The gap between live part of the Panel shall be minimum 35mm.All openings shall be covered by soft rubber gasket (metal based neoprene) having structural re-inforcement with suitable Angle/Channel/T/Flat sections, hinged and lockable doors enclosure shall be galvanized. (50 % OF Total Amount of Itom nos a to q) is Rs. 180940.42 = Rs.90470.21 |
| 304 | Electrical Barrack -4 |
| 305 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 306 | 1.3.2Group B |
| 307 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 308 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 309 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 310 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 311 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 312 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 313 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 314 | 1.24.15/6 amps, one way switch |
| 315 | 1.24.315/16 amps, one way switch |
| 316 | 1.24.45/6amps, 3 pin socket outlet |
| 317 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 318 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 319 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 320 | 1.27.36 module(78mm x 205mm x 50mm) |
| 321 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 322 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 323 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 324 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 325 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 326 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 327 | 2.4.125/100 amps, 10 KA fixed thermal seting |
| 328 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 329 | 2.8.88 Way,Double door |
| 330 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 331 | 2.9.44 way (4+12),Double door, Horizontal type |
| 332 | 2.9.56 way (4+18),Double door, Horizontal type |
| 333 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 334 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 335 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 336 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 337 | 2.12.640 amps ,DP |
| 338 | 2.12.940 amps,TPN |
| 339 | 2.12.1050/63 amps, TPN |
| 340 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 341 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 342 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 343 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 344 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 345 | M-74016 sq.mm. 4 core |
| 346 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 347 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 348 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 349 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 350 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 351 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 352 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 353 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 354 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 355 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S |
| 356 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 357 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 358 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 359 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 360 | Electrical Barrack -5 |
| 361 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 362 | 1.3.2Group B |
| 363 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 364 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 365 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 366 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 367 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 368 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 369 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 370 | 1.24.15/6 amps, one way switch |
| 371 | 1.24.315/16 amps, one way switch |
| 372 | 1.24.45/6amps, 3 pin socket outlet |
| 373 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 374 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 375 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 376 | 1.27.36 module(78mm x 205mm x 50mm) |
| 377 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 378 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 379 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 380 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 381 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 382 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 383 | 2.4.125/100 amps, 10 KA fixed thermal seting |
| 384 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 385 | 2.8.88 Way,Double door |
| 386 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 387 | 2.9.44 way (4+12),Double door, Horizontal type |
| 388 | 2.9.56 way (4+18),Double door, Horizontal type |
| 389 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 390 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 391 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 392 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 393 | 2.12.640 amps ,DP |
| 394 | 2.12.940 amps,TPN |
| 395 | 2.12.1050/63 amps, TPN |
| 396 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 397 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 398 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 399 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 400 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 401 | M-74016 sq.mm. 4 core |
| 402 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 403 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 404 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 405 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 406 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 407 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 408 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 409 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 410 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 411 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S |
| 412 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 413 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 414 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 415 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 416 | Electrical Barrack -6 |
| 417 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 418 | 1.3.2Group B |
| 419 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 420 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 421 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 422 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 423 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 424 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 425 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 426 | 1.24.15/6 amps, one way switch |
| 427 | 1.24.315/16 amps, one way switch |
| 428 | 1.24.45/6amps, 3 pin socket outlet |
| 429 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 430 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 431 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 432 | 1.27.36 module(78mm x 205mm x 50mm) |
| 433 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 434 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 435 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 436 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 437 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 438 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 439 | 2.4.125/100 amps, 10 KA fixed thermal seting |
| 440 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 441 | 2.8.88 Way,Double door |
| 442 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 443 | 2.9.44 way (4+12),Double door, Horizontal type |
| 444 | 2.9.56 way (4+18),Double door, Horizontal type |
| 445 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 446 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 447 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 448 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 449 | 2.12.640 amps ,DP |
| 450 | 2.12.940 amps,TPN |
| 451 | 2.12.1050/63 amps, TPN |
| 452 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 453 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 454 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 455 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 456 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 457 | M-74016 sq.mm. 4 core |
| 458 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 459 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 460 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 461 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 462 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 463 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 464 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 465 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 466 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 467 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S |
| 468 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 469 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 470 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 471 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 472 | Electrical Barrack -7 |
| 473 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 474 | 1.3.2Group B |
| 475 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 476 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 477 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 478 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 479 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 480 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 481 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 482 | 1.24.15/6 amps, one way switch |
| 483 | 1.24.315/16 amps, one way switch |
| 484 | 1.24.45/6amps, 3 pin socket outlet |
| 485 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 486 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 487 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 488 | 1.27.36 module(78mm x 205mm x 50mm) |
| 489 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 490 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 491 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 492 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 493 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 494 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 495 | 2.4.125/100 amps, 10 KA fixed thermal seting |
| 496 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 497 | 2.8.88 Way,Double door |
| 498 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 499 | 2.9.44 way (4+12),Double door, Horizontal type |
| 500 | 2.9.56 way (4+18),Double door, Horizontal type |
| 501 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 502 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 503 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 504 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 505 | 2.12.640 amps ,DP |
| 506 | 2.12.940 amps,TPN |
| 507 | 2.12.1050/63 amps, TPN |
| 508 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 509 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 510 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 511 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 512 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 513 | M-74016 sq.mm. 4 core |
| 514 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 515 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 516 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 517 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 518 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 519 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 520 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 521 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 522 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 523 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S |
| 524 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 525 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 526 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 527 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 528 | Electrical Kitchen |
| 529 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 530 | 1.3.2Group B |
| 531 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 532 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 533 | 1.7.12x1.5 sq mm+1x1.5 sq mm earth wire |
| 534 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 535 | 1.7.52x10.0 sq mm+1x6.0 sq mm earth wire |
| 536 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 537 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 538 | 1.24.15/6 amps, one way switch |
| 539 | 1.24.315/16 amps, one way switch |
| 540 | 1.24.45/6amps, 3 pin socket outlet |
| 541 | 1.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required. |
| 542 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 543 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 544 | 1.27.36 module(78mm x 205mm x 50mm) |
| 545 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required. |
| 546 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 547 | 1.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required. |
| 548 | 1.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1 |
| 549 | 1.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 550 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required. |
| 551 | 2.4.125/100 amps, 10 KA fixed thermal seting |
| 552 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 553 | 2.8.912 Way,Double door |
| 554 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 555 | 2.9.44 way (4+12),Double door, Horizontal type |
| 556 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 557 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 558 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 559 | 2.12.16/32 amps,single pole, \"C\" SERIES |
| 560 | 2.12.640 amps ,DP |
| 561 | 2.12.940 amps,TPN |
| 562 | 2.12.1050/63 amps, TPN |
| 563 | 3.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke. |
| 564 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 565 | 5.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 566 | 7.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 567 | Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 568 | M-74016 sq.mm. 4 core |
| 569 | 12.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 570 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 571 | 9.1.33DSR4 X 16 sq. mm (28mm) |
| 572 | CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 573 | CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 574 | Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel |
| 575 | 9.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. |
| 576 | 9.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar |
| 577 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 578 | 9.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S |
| 579 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 580 | 9.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S |
| 581 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 582 | 9.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S |
| 583 | Add 18% GST |
| 584 | Add 1% Lebour Cess |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy