Housing Urban and Rular Development Government Departments Closing in 0 days TDR #42054195

Tender For Repair Work At C.I.A.T. School, Musabani In The District Of East Singhbhum

Issued by Government Departments · musabani, Jharkhand
Tender Value
1.43 Crore
Estimated cost
Bid Submission
16 Feb 2024
0 days left
EMD
2.87 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
musabani → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair Work At C.I.A.T. School, Musabani In The District Of East Singhbhum

BOQ

Name of Work: Repair work at C.I.A.T. School, Musabani in the district of East Singhbhum
Sl. No. Item Description
1Section I
2Building Work (Barrack 1&2)
3DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
4DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
512.51.1Ridges plain (500 - 600mm)
612.51.6Gutter (600 mm over all girth)
75.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
85.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
95.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
10DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
1113.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
125.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
1312.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing.
14DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia
1512.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
1612.42.5.2Bend 110mm
1712.42.6.2Shoe 110 mm
1812.42.1.2Coupler 110 mm
19DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
2012.43.2110 mm
21Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
22(a) Bricks (1+25) = 26
23(b) Coarse Sand(1+9=10 Km )
24(c) Cement (40 Km )
25Building Work (Barrack 3)
26DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
27DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
2812.51.1Ridges plain (500 - 600mm)
2912.51.6Gutter (600 mm over all girth)
305.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
315.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
325.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
33DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
3413.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
355.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
3612.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing.
37DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia
3812.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
3912.42.5.2Bend 110mm
4012.42.6.2Shoe 110 mm
4112.42.1.2Coupler 110 mm
42DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
4312.43.2110 mm
44Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
45(a) Bricks (1+25) = 26
46(b) Coarse Sand(1+9=10 Km )
47(c) Cement (40 Km )
48Building Work (Barrack 4,5,6 &7)
49DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
50DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
5112.51.1Ridges plain (500 - 600mm)
5212.51.6Gutter (600 mm over all girth)
535.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
545.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
555.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
56DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
5713.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
585.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
5912.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing.
60DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia
6112.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
6212.42.5.2Bend 110mm
6312.42.6.2Shoe 110 mm
6412.42.1.2Coupler 110 mm
65DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
6612.43.2110 mm
67Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
68(a) Bricks (1+25) = 26
69(b) Coarse Sand(1+9=10 Km )
70(c) Cement (40 Km )
71Building Work (Kitchen)
72DSR 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
73DSR 12.51Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
7412.51.1Ridges plain (500 - 600mm)
7512.51.6Gutter (600 mm over all girth)
765.2.11Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
775.7.3Providing 12mm thick cement plaster (1:6)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
785.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
79DSR 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
8013.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
815.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
8212.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bondedglass wool backing.
83DSR 12.41.2Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia
8412.42Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
8512.42.5.2Bend 110mm
8612.42.6.2Shoe 110 mm
8712.42.1.2Coupler 110 mm
88DSR 12.43Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
8912.43.2110 mm
90Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
91(a) Bricks (1+25) = 26
92(b) Coarse Sand(1+9=10 Km )
93(c) Cement (40 Km )
94Electrical Barrack -1
95Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell\"s/Polycab/Finolex/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / C&S/ Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:Havell\"s/L&T/Legrand/Schneider/C&S (6)XLPE/PVC aramoured cable:-Havell\"s/Polycab/V-guard/Finolex (7) LED FTTING FIXTURE -: Havells/Bajaj/Crompton/C&S (Model/as per E/I ) (8) CEILING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha(Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Surya/Valmont/RR Ispat/Transrail(10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Mahindra
961.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
971.3.2Group B
981.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
991.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1001.7.12x1.5 sq mm+1x1.5 sq mm earth wire
1011.7.22x2.5 sq mm+1x2.5 sq mm earth wire
1021.7.42x6.0 sq mm+1x6.0 sq mm earth wire
1031.7.52x10.0 sq mm+1x6.0 sq mm earth wire
1041.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
1051.24.15/6 amps, one way switch
1061.24.315/16 amps, one way switch
1071.24.45/6amps, 3 pin socket outlet
1081.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
1091.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
1101.27.11 or 2 module(78mm x 78mm x 45mm)
1111.27.36 module(78mm x 205mm x 50mm)
1121.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
1131.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
1141.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
1151.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
1161.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
1171.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
1182.1S/F rewireble double pole/TP&N switch disconector:-Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required.
1192.1.563 amps, TP&N
1202.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
1212.8.88 Way,Double door
1222.8.1016 Way,Double door
1232.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
1242.11.16/32 amps,single pole, \"B\" SERIES
1252.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
1262.12.16/32 amps,single pole, \"C\" SERIES
1272.12.640 amps ,DP
1282.12.750/63 amps, DP
1292.12.1050/63 amps, TPN
1303.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
1313.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
1325.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
1337.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
134Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
135M-74016 sq.mm. 4 core
13612.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
1379.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
1389.1.33DSR4 X 16 sq. mm (28mm)
139CODE No. M - 774Providing of 9\"\" (230 mm) Metal exhaust fan of make bajaj/havells/usha/crompton
140CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
141CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
142Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
1439.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
1449.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
1459.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
1469.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S
1479.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
1489.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
1499.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
1509.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
151Electrical Barrack -2
1521.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
1531.3.2Group B
1541.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
1551.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1561.7.12x1.5 sq mm+1x1.5 sq mm earth wire
1571.7.22x2.5 sq mm+1x2.5 sq mm earth wire
1581.7.42x6.0 sq mm+1x6.0 sq mm earth wire
1591.7.52x10.0 sq mm+1x6.0 sq mm earth wire
1601.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
1611.24.15/6 amps, one way switch
1621.24.315/16 amps, one way switch
1631.24.45/6amps, 3 pin socket outlet
1641.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
1651.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
1661.27.11 or 2 module(78mm x 78mm x 45mm)
1671.27.36 module(78mm x 205mm x 50mm)
1681.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
1691.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
1701.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
1711.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
1721.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
1731.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
1742.1S/F rewireble double pole/TP&N switch disconector:-Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required.
1752.1.563 amps, TP&N
1762.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
1772.8.88 Way,Double door
1782.8.1016 Way,Double door
1792.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
1802.11.16/32 amps,single pole, \"B\" SERIES
1812.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
1822.12.16/32 amps,single pole, \"C\" SERIES
1832.12.640 amps ,DP
1842.12.750/63 amps, DP
1852.12.1050/63 amps, TPN
1863.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
1873.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
1885.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
1897.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
190Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
191M-74016 sq.mm. 4 core
19212.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
1939.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
1949.1.33DSR4 X 16 sq. mm (28mm)
195CODE No. M - 774Providing of 9\"\" (230 mm) Metal exhaust fan of make bajaj/havells/usha/crompton
196CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
197CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
198Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
1999.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
2009.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
2019.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
2029.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S
2039.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
2049.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
2059.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
2069.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
207Electrical Barrack -3 (Store, Feeder, Panel & Street Lighting.)
2081.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
2091.3.2Group B
2101.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
2111.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
2121.7.12x1.5 sq mm+1x1.5 sq mm earth wire
2131.7.22x2.5 sq mm+1x2.5 sq mm earth wire
2141.7.52x10.0 sq mm+1x6.0 sq mm earth wire
2151.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
2161.24.15/6 amps, one way switch
2171.24.315/16 amps, one way switch
2181.24.45/6amps, 3 pin socket outlet
2191.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
2201.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
2211.27.11 or 2 module(78mm x 78mm x 45mm)
2221.27.36 module(78mm x 205mm x 50mm)
2231.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
2241.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
2251.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
2261.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
2271.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
2282.1S/F rewireble double pole/TP&N switch disconector:-Providing and fixing following capecity double pole/ TP&N sheet metal switch disconnector fuse unit in exiting metal board with rewireble type fuse including drilling holes in metal board making connection etc as required.
2292.1.432 amps, TP&N
2302.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
2312.9.44 way (4+12),Double door, Horizontal type
2322.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2332.11.16/32 amps,single pole, \"B\" SERIES
2342.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2352.12.16/32 amps,single pole, \"C\" SERIES
2362.12.86/32 amps,TPN
2373.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
2383.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
2395.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
2407.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
241Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
242M-73910 sq.mm. 4 core
24312.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
2449.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2459.1.33DSR4 X 16 sq. mm (28mm)
246CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
247CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
248Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
2499.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
2509.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
2519.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
2529.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S
2539.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
2549.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
2559.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
2569.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
257FEEDER PILLER AND MAIN CABLE TO TRANSFORMER & STREET LIGHT
2581.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
2591.7.22x2.5 sq mm+1x2.5 sq mm earth wire
2602.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2612.11.16/32 amps,single pole, \"B\" SERIES
2622.19P/F M.V. danger notice plate:-Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
2633.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
2643.6Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke)
2653.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
2663.8S/L 6 SWG G.I. wire ground :-Supplying and laying 6 SWG G.I. wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
2675.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. For Barrack 8,9 &10
2685.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. For strret light
2695.3Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 95 sq.mm. but not exceeding 185 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
2707.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
271Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
272M-74016 sq.mm. 4 core for barrack 8,9 &10
273M-74016 sq.mm. 4 core for street light
274M-332150 sq.mm. 3.5 core
27512.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
27612.38 DSRSupplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
2779.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2789.1.33DSR4 X 16 sq. mm (28mm)
2799.2S.I.T.C of following rating LED FLOOD lighting with pressure dia cast housing and toughened glass cover (IP 66 protection)in existing pole/pipe /platform/periferial wallfor supply voltage 100-270v AC,50Hz Luminire shall be confirmto IS-10322 part-5/ section-3 and shall be complete with all neccssary accessories as required.of make bajaj/havells/crompton/C&S
2809.2.5120 W LED FLOOD LIGHT of make bajaj/havells/crompton/C&S
2819.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
2829.1.790 /100 W LED Street light of make bajaj/havells/crompton/C&S
283Code no. M-742Supply of 7 Mtr height Octagonal Hot Dip Galvenized pole (BOP - 7030) with top dia 70 mm, bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12mm (L X B X T) including suitable sizes of foundetion bolt all complete as requried. (Without Arm)
284Code no. M-7581.5 Mtr Single Arm suitable for 70 mm TOP
285Code no. M-875Instalation Testing & Commisioning of 7 Mtr Octagonal Pole & light fitting with the help of tools & plants, wiring of luminaires with all materials and construction of shallow foundetion with M 25 grade concreat considering safe soil bearing capacity of 10T/Mtrs sq
286LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMINGwith following:
287INCOMING
288(a) M - 322315 amps, 35 KA Adjestable thermal seting
289(b) M -584160A changover FP Open excution type With rootary handle (ON-LOAD)
290(C) M - 620400A TPN BUSBAR(COPPER)
291OUTGOING
292(d)M - 31825/100 amps, 16 KA fixed thermal seting
293(g) 2.12.332 amps.SPN MCB
294OTHER ACCESSOSRIES
295(j) Code no. M- 873 ADIGITAL VOLT METER 500V(3phase class 0.5)
296(k) Code no. M- 873 BDIGITAL A METER 500V(3phase class 0.5)
297(l) Code no. M- 445COPPER WIRE 1.5MM
298(m) Code no. M- 448COPPER WIRE 6MM
299(n) Code no. M- 449COPPER WIRE 10MM
300(o) Code no. M- 451COPPER WIRE 25MM
301(p) Code no. M- 1455LED INDICATOR LAMP R/Y/B/G
302(q) Code no. M- 1452C.T COIL OF CT ratio 500/5 IS2705 part -3
303Anaylised & ApprovedLT PANEL(Waterproof):-Supplying,Fixing, Designing, Cmmisioning, Manufactored Double Door LT Panel fabricated out of 1.626 mm thick(16SWG) CRCA sheet steel, dust and vermin proofwith reinforcement of suitable size iron channel, size 75mmx75mmx6mm with proper lifting arrangement effecting proper connection of all incomer and out going (IP-66) fully compartmentalized cubical type (folded joints construction), wall floor mounted, totally enclosed, extendable on both sides, switch board and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having 36 KA fault capacity, housed with incoming,Steel Stand, interconnection, interlocking between feeders etc. space for 3 phase Energy meter 1 nos,as required.The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized cubical panel, 2 Nos. earth studs. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.The pannel shall be interlocked with switchgear.The gap between live part of the Panel shall be minimum 35mm.All openings shall be covered by soft rubber gasket (metal based neoprene) having structural re-inforcement with suitable Angle/Channel/T/Flat sections, hinged and lockable doors enclosure shall be galvanized. (50 % OF Total Amount of Itom nos a to q) is Rs. 180940.42 = Rs.90470.21
304Electrical Barrack -4
3051.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
3061.3.2Group B
3071.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
3081.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
3091.7.12x1.5 sq mm+1x1.5 sq mm earth wire
3101.7.22x2.5 sq mm+1x2.5 sq mm earth wire
3111.7.52x10.0 sq mm+1x6.0 sq mm earth wire
3121.7.104x6 sq mm+2x6 sq mm earth wire
3131.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
3141.24.15/6 amps, one way switch
3151.24.315/16 amps, one way switch
3161.24.45/6amps, 3 pin socket outlet
3171.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
3181.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
3191.27.11 or 2 module(78mm x 78mm x 45mm)
3201.27.36 module(78mm x 205mm x 50mm)
3211.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
3221.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
3231.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
3241.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
3251.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
3262.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required.
3272.4.125/100 amps, 10 KA fixed thermal seting
3282.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
3292.8.88 Way,Double door
3302.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
3312.9.44 way (4+12),Double door, Horizontal type
3322.9.56 way (4+18),Double door, Horizontal type
3332.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
3342.11.16/32 amps,single pole, \"B\" SERIES
3352.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
3362.12.16/32 amps,single pole, \"C\" SERIES
3372.12.640 amps ,DP
3382.12.940 amps,TPN
3392.12.1050/63 amps, TPN
3403.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
3413.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
3425.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
3437.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
344Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
345M-74016 sq.mm. 4 core
34612.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
3479.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
3489.1.33DSR4 X 16 sq. mm (28mm)
349CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
350CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
351Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
3529.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
3539.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
3549.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
3559.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S
3569.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
3579.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
3589.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
3599.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
360Electrical Barrack -5
3611.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
3621.3.2Group B
3631.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
3641.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
3651.7.12x1.5 sq mm+1x1.5 sq mm earth wire
3661.7.22x2.5 sq mm+1x2.5 sq mm earth wire
3671.7.52x10.0 sq mm+1x6.0 sq mm earth wire
3681.7.104x6 sq mm+2x6 sq mm earth wire
3691.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
3701.24.15/6 amps, one way switch
3711.24.315/16 amps, one way switch
3721.24.45/6amps, 3 pin socket outlet
3731.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
3741.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
3751.27.11 or 2 module(78mm x 78mm x 45mm)
3761.27.36 module(78mm x 205mm x 50mm)
3771.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
3781.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
3791.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
3801.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
3811.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
3822.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required.
3832.4.125/100 amps, 10 KA fixed thermal seting
3842.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
3852.8.88 Way,Double door
3862.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
3872.9.44 way (4+12),Double door, Horizontal type
3882.9.56 way (4+18),Double door, Horizontal type
3892.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
3902.11.16/32 amps,single pole, \"B\" SERIES
3912.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
3922.12.16/32 amps,single pole, \"C\" SERIES
3932.12.640 amps ,DP
3942.12.940 amps,TPN
3952.12.1050/63 amps, TPN
3963.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
3973.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
3985.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
3997.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
400Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
401M-74016 sq.mm. 4 core
40212.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
4039.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
4049.1.33DSR4 X 16 sq. mm (28mm)
405CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
406CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
407Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
4089.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
4099.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
4109.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
4119.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S
4129.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
4139.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
4149.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
4159.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
416Electrical Barrack -6
4171.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
4181.3.2Group B
4191.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
4201.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
4211.7.12x1.5 sq mm+1x1.5 sq mm earth wire
4221.7.22x2.5 sq mm+1x2.5 sq mm earth wire
4231.7.52x10.0 sq mm+1x6.0 sq mm earth wire
4241.7.104x6 sq mm+2x6 sq mm earth wire
4251.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
4261.24.15/6 amps, one way switch
4271.24.315/16 amps, one way switch
4281.24.45/6amps, 3 pin socket outlet
4291.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
4301.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
4311.27.11 or 2 module(78mm x 78mm x 45mm)
4321.27.36 module(78mm x 205mm x 50mm)
4331.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
4341.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
4351.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
4361.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
4371.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
4382.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required.
4392.4.125/100 amps, 10 KA fixed thermal seting
4402.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
4412.8.88 Way,Double door
4422.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
4432.9.44 way (4+12),Double door, Horizontal type
4442.9.56 way (4+18),Double door, Horizontal type
4452.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
4462.11.16/32 amps,single pole, \"B\" SERIES
4472.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
4482.12.16/32 amps,single pole, \"C\" SERIES
4492.12.640 amps ,DP
4502.12.940 amps,TPN
4512.12.1050/63 amps, TPN
4523.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
4533.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
4545.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
4557.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
456Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
457M-74016 sq.mm. 4 core
45812.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
4599.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
4609.1.33DSR4 X 16 sq. mm (28mm)
461CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
462CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
463Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
4649.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
4659.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
4669.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
4679.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S
4689.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
4699.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
4709.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
4719.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
472Electrical Barrack -7
4731.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
4741.3.2Group B
4751.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
4761.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
4771.7.12x1.5 sq mm+1x1.5 sq mm earth wire
4781.7.22x2.5 sq mm+1x2.5 sq mm earth wire
4791.7.52x10.0 sq mm+1x6.0 sq mm earth wire
4801.7.104x6 sq mm+2x6 sq mm earth wire
4811.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
4821.24.15/6 amps, one way switch
4831.24.315/16 amps, one way switch
4841.24.45/6amps, 3 pin socket outlet
4851.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
4861.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
4871.27.11 or 2 module(78mm x 78mm x 45mm)
4881.27.36 module(78mm x 205mm x 50mm)
4891.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
4901.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
4911.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
4921.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
4931.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
4942.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required.
4952.4.125/100 amps, 10 KA fixed thermal seting
4962.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
4972.8.88 Way,Double door
4982.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
4992.9.44 way (4+12),Double door, Horizontal type
5002.9.56 way (4+18),Double door, Horizontal type
5012.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
5022.11.16/32 amps,single pole, \"B\" SERIES
5032.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
5042.12.16/32 amps,single pole, \"C\" SERIES
5052.12.640 amps ,DP
5062.12.940 amps,TPN
5072.12.1050/63 amps, TPN
5083.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
5093.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
5105.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
5117.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
512Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
513M-74016 sq.mm. 4 core
51412.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
5159.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
5169.1.33DSR4 X 16 sq. mm (28mm)
517CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
518CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
519Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
5209.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
5219.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
5229.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
5239.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S
5249.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
5259.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
5269.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
5279.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
528Electrical Kitchen
5291.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
5301.3.2Group B
5311.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
5321.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
5331.7.12x1.5 sq mm+1x1.5 sq mm earth wire
5341.7.22x2.5 sq mm+1x2.5 sq mm earth wire
5351.7.52x10.0 sq mm+1x6.0 sq mm earth wire
5361.7.104x6 sq mm+2x6 sq mm earth wire
5371.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
5381.24.15/6 amps, one way switch
5391.24.315/16 amps, one way switch
5401.24.45/6amps, 3 pin socket outlet
5411.25S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
5421.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
5431.27.11 or 2 module(78mm x 78mm x 45mm)
5441.27.36 module(78mm x 205mm x 50mm)
5451.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
5461.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
5471.35Errection on incandescent light fitting:-Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
5481.43S/F Extra down rods:-.Providing and fixing extra conduit down rod of 20 mm dia., 2x10 cm. length wiring with 2x1.5 sq mm FR PVC insuleted copper conductor, single core cable including painting etc as required(Note more than 5 cm length shall be rounded to the nearest 1
5491.44ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
5502.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panelmaking connections etc as required.
5512.4.125/100 amps, 10 KA fixed thermal seting
5522.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
5532.8.912 Way,Double door
5542.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
5552.9.44 way (4+12),Double door, Horizontal type
5562.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
5572.11.16/32 amps,single pole, \"B\" SERIES
5582.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
5592.12.16/32 amps,single pole, \"C\" SERIES
5602.12.640 amps ,DP
5612.12.940 amps,TPN
5622.12.1050/63 amps, TPN
5633.2G.I Earth pipe electrode with salt charcoal :-Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
5643.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
5655.1Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
5667.1 JSRSupplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
567Code no.Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
568M-74016 sq.mm. 4 core
56912.37 DSRSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
5709.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
5719.1.33DSR4 X 16 sq. mm (28mm)
572CODE No.M - 777Providing of 16\"\" (400 mm) Wall fan of make bajaj/havells/usha/crompton
573CODE No.M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
574Code no. M 874Supplying and fixing of cable junction box of make sintex /Hensel
5759.4S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
5769.4.11200 mm (48\") Ceiling Fan of make bajaj/havells/usha/crompton/polar
5779.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
5789.5.220/22 W LED Battenof make bajaj/havells/crompton/C&S
5799.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
5809.1.445/48 W LED Street light of make bajaj/havells/crompton/C&S
5819.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
5829.3.315/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
583Add 18% GST
584Add 1% Lebour Cess

AI Tender Summary

OUR REF NO 42054195
AUTHORITY Government Departments
TENDER VALUE 1.43 Crore
LAST DATE 16-02-2024
Authority
Authority Name Jharkhand Police Housing Corporation Limited
Work Description Repair Work At C.I.A.T. School, Musabani In The District Of East Singhbhum
Basic Detail
Tender No JPHCL/GR 01/NIT 23/2023-24
Bidding Type Tender
Location
City musabani
State Jharkhand
Key Dates
Publish Date 06 Feb 2024
Submission Date 16 Feb 2024
Open Date 17 Feb 2024
Finance
Tender Value 1.43 Crore
Tender Fee 10000
EMD 2.87 Lakhs
Exemption Not Available
Document List
dab58efe-0bb4-46e2-84f6-8a270b9936ad.html
BOQ_109768.xls
Techbid1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 06, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 16, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 17, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

dab58efe-0bb4-46e2-84f6-8a270b9936ad.html

xls

BOQ_109768.xls

pdf

Techbid1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders