Tender For Construction Of G Plus 2 Guest House Block 1 At Deoghar Police Line In The District Of Deoghar
Tender Value
6.06 Crore
Estimated cost
Bid Submission
16 Feb 2024
0 days left
EMD
6.07 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Deoghar → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of G Plus 2 Guest House Block 1 At Deoghar Police Line In The District Of Deoghar
BOQ
| Sl. No. | Item Description |
| 1 | Section I Building Work |
| 2 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 3 | Extra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B) |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Hard rock (blasting prohibited) |
| 5 | Filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 6 | Filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered rammed fully compacted and fine dressed with earthobtainedafter Cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 7 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 8 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 10 | Providing designation 75A brick work inC.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)IN FOUNDATION |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form forCentering and shuttering including strutting, propping etc. and removal of form for |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)Plinth Band |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 21 | Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 23 | Reinforcedcementconcreteworkin beams,Slab,Lintel Band,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform in Lintel Band |
| 25 | Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form forStairs, (excluding landings) except spiral-staircases |
| 27 | Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form forWeather shade, Chajjas, corbels etc., including edges |
| 29 | Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form forShelves (Cast in situ) |
| 31 | Exra for adddition Height in centering, shuttering where ever required with adequate bracing, propping etc. , including cost of deshuttering and at all levels, over a height of 3.5 m, for every additional height of 1metre or part there of (plan area to be measured)Suspended floors, roofs, landing, beams and balconies (plan area to be measured) |
| 32 | Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 33 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in CM (1:6) in super structure with approved quality of Clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials raking our joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I |
| 34 | Providing designation 112 mm thick reinforced designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990(9\"x4.5\"x3\") in C.M (1:4) in Superstructure with approval quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening, carriage of materials, sacfolding, raking out joints to 15 mm depth , curing , taxes and royality ( but excluding the cost of reinforcement) all complete as per building specification |
| 35 | Providing 12mm thickcement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 36 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 37 | Extra for brick work for each consecutive floor above first floorincluding watering and scaffolding, all complete as per direction of E/I. |
| 38 | ( a) For S.F. |
| 39 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. |
| 40 | ( a) For S.F. Total RCC in 2nd Floor |
| 41 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 42 | Providing reinforecment ( Round bars conforming to I.S 432 dia in mm ( I.S 2062 Gr.A ) to 6 &8 mm dia rods as per approved design and drawing excluding carriage of bars to work sitecutting bending and binding with annealed wire with cost of wire, removal or rust placing the rods in position all complete as per building specification and direction of E/I.(i) 6mm dia Gr. A ( Only Valid for SAIL & TATA Steel ) |
| 43 | Providing TMT steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of Rods (straight orin coils) to work site, cutting,bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position complete as per building specification and direction of E/I. |
| 44 | Providing TMT Steelreinforcementof 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage ofM.S. Rods (straight or in coils) to work site, cutting bending and bindingwith annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specificationand direction of E/I |
| 45 | 10 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel ) |
| 46 | 12 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel ) 16 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel )Providing TMT steel reinforcement of20 mm & 25mm dia, bars as per approved design and drawing excluding carriage ofM.S. Rods (straight or in coils) to work site, cutting bendingand binding with annealed wire with costof wire, removal of rust placing the rods in positionall complete as per building specification and direction of E/I.(TMT Fe 500 (Only valid for SAIL & TATA Steel ) |
| 47 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 48 | Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately). |
| 49 | Sal wood |
| 50 | Supplying, fitting & fixing 30mm thick solid core type decorative Single leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes allcomplete as per building specification and direction of E/I. |
| 51 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.). |
| 52 | Supplying , fitting and fixing collepsible gate of approved size & make properly febricated with vertical double channels 20 x 10 x 2 mm at 100 mm center & braced with M.S.flat diagonals 20 x 3 mm, with top & bottom rails of T - iron 40 x 40 x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting & taxes all complete as per building specification and direction of E/I. |
| 53 | Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage ofwater etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 54 | Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 55 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness |
| 56 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawingsfor the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design windpressure without any failure), including functional design of the aluminum sections for fixing glazing panels of variousthicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals,microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: |
| 57 | (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel frameworkof building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nutsand washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 58 | (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holdingglass. |
| 59 | (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 60 | (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, byincorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directedby the Engineer- in-Charge. |
| 61 | Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (includingwidth of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazingexceeds 2500 Sqm from the certified laboratories accreditated by NABL (National Accreditation Board forTesting and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payableseparately. |
| 62 | The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 170251. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. |
| 63 | 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 64 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified,comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear floatglass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architecturaldrawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included incost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. |
| 65 | (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm HeatStrengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Lightreflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 66 | Supplying, fitting & fixing 35mm thick solid core type decorative Double leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes allcomplete as per building specification and direction of E/I. |
| 67 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-ChargeGranite work |
| 68 | Providing and fixing wooden moulded beading to doorframes with iron screws, plugs and priming coat on unexposed surface etc. complete. 50X20 MM |
| 69 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 70 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily. DSR11.41A.1 Double charge vitrified tile polished finish of size11.41A.1.3 Size of Tile 600 x 1200 mm |
| 71 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 72 | Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm sqm |
| 73 | Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust)with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Raj Nagar Plain white marble/ Udaipur green marble/ Zebrablack marble.Area of slab upto 0.50 sqm |
| 74 | Extra for plaster work over exterior surface for each consecutivefloor above first floor including cost ofscaffolding etc. all complete as per direction of E/I. |
| 75 | Making 6x6mm grooves in plaster surface over walls truly horizontal vertical as specifiedat regular intervals at all heights including cleaning finishing scaffoding and curing with all leads and lifts of water all complete as per building specification and direction of E/I. |
| 76 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 77 | Providing& supplyingCico liquid / impermo water proofing compound in cement concrete or cement mortar @2% of cement quqntity by weight ( as specified)for water proofing, including all carraige and taxes . |
| 78 | Chequered terrazo tiles 22 mm thick with graded marble chips of sizeup to 6 mm in floors, jointed with neat cement slurry mixed with pigmentto match the shade of the tiles, including rubbing and polishing complete,on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement |
| 79 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 80 | Provideing 19 mm thick water proof plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other apporoved water proffing compound including screening , curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specefication and direction of E/I |
| 81 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth. |
| 82 | Providing 250 mm wide brick drain in cement mortar (1: 6) with av. 150 mm. clean depth and 150 mm apron including cost of earthwork involved with 75 mm, cement concrete (1: 4: 3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain duly plastered in C.M (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 83 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 84 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied@ 2.20kg/10 sqm |
| 85 | Providing two coat of Oil bond distemperof approved shade and make over a cement primerover new surfaceincluding preparing the plastered surface by rubbing smooth with pumic stone or fine sand papper ,applying putty where requiredscaffolding, washing the floor and taxes all complete as per building specification and direction of E/I. |
| 86 | Finishing Wall with acrylic smooth exterior paint of required shade : New work ( Two or more coat applied @1.67 lit./ 10 sq.m over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm) |
| 87 | Supplying fitting & fixing Kitchen Cabinet - 22\"deep & 2\"-6\" height Base unit & 2\"-0\"X12\" deep upper unit with specific stainless steel Baskets, Telescopic channel, marineply shutters & Aluminium & Wooden structure as per design and follwing detail specifications -(For 1 Kitchen) |
| 88 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at Code Description Unit Rate No SUB HEAD : 12.0 ROOFING 215 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: |
| 89 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 90 | Supplying fitting & fixing 22\"/ 24\" deep ROOM CUPBOARD made with 19mm th. Waterproof 3 ply commercial board (GREEN) shutters & shelves supported on 2\"X2\" aluminum angle screwed to the wall/ supports (board), front of shutters to be laminated with 1.5mm th. decorative matt finish with high density protective layer surface sheet (GREEN) including cost of adhesive, one drawer of 1\"x5\" size with heavy duty drawer channel 20\" (ebbco), stainless steel hinges, 6\" handle -2 no.,4\" handle - 2 nos.,Tower bolt - 2 no., magnet - 3 nos. ,cupboard lock (GODREJ)-1no., Drawer lock - 1 no. (GODREJ), drawer knob, 3/4\" dia. stainless steel pipe with socket for hanger, etc. all exposed edges covered with teak wood lipping bead and all inner sides of cupboard to be painted with 2 coats of enamel painting over a coat of primer. All Board, Laminate Sheet,Hardwares & Paints to be approved by the Architects. |
| 91 | French spirit polishing :Two or more coats on new works including a coat of wood filler |
| 92 | Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly includingcost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 93 | Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 94 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 95 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 96 | Coupler 110 MM |
| 97 | Single pushfit Coupler |
| 98 | 110 MMSingle pushfit coupler |
| 99 | Single tee with door |
| 100 | 110X110X110 MM |
| 101 | Single tee without door |
| 102 | 110X110X110 MM |
| 103 | Bend 87.5° |
| 104 | 110 MM Bend |
| 105 | 110 MM Shoe |
| 106 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 107 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 108 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 109 | (a) Fly Ash Bricks |
| 110 | (b) Bricks |
| 111 | (c) Coarse Sand |
| 112 | (d) Stone Chips |
| 113 | (e) Cement |
| 114 | (f) Steel |
| 115 | (g) Earth |
| 116 | SectionIIWater Supply |
| 117 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain &brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls |
| 118 | (a) 15mm dia |
| 119 | (b) 20mm dia |
| 120 | (c) 25mm dia |
| 121 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 122 | Supplying materials labour tools for fixings of gun matel full way valve of approved quality with all complete job. |
| 123 | (a) 25 mm dia |
| 124 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Jaquar/Hindware Make |
| 125 | 15 mm nominal bore |
| 126 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 127 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing : Circular shape 450 mm dia |
| 128 | SANITARY WORK |
| 129 | Supplying , fitting and fixingvitreous whiteglazed earthenware I.W.C. of Party Hindustan orany other I.S.S approved make with 100mm H.C.I. \"P\" trap 15 litres C.I. pull and let go flushingcisternof nmaesor other I.S.S equipalent make complete withallfittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass couplingandclamps G.I. chain andpull includingsupplyingandfixingapairofvitreour white glazed eaarthenwarefoot rest to be fixed infloor 15mm C.I. bodybrass spindlestop cockofweight notlessthan 50grms, 15mm P.V.C. connection pipe 450 mm longand the exposedpiep andcistern withtwo coatsof approved paint over a coat ofred oxideprimer etc.allcomplete as per building specification and direction of E/I. Jaquar/Hindware Make |
| 130 | © 580mm long I.W.C. pan with 10 litres low leve P.V.C. Cistern. Hindware/Jaquar Make |
| 131 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required Jaquar,Hindware Make E.W.C. pan with ISI marked white solid plastic seat and lid |
| 132 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps |
| 133 | Providing and Fixing Hand Shower ( Health Faucet) ( ABS Body) ALD-CHR-585 Jaquar made.Hand Shower with 1 meter Long Easy Flex Tube in Chrome Finish & Wall Hook. |
| 134 | CP Brass Single lever telephonic wall mixer of approved make |
| 135 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms |
| 136 | Supplying Fitting FixingDivertor Internal Part all accessories (Make jaguar model no. ALD-079 or Equivalent like Mark, Grohe. ) |
| 137 | Supplying Fitting Fixing Divertor External Part with all accessories (Make jaguar model no. FLR-5079K or Equivalent like Mark, Grohe. ) |
| 138 | Supplying Fitting Fixing Spout with all accessories (Make jaguar model no. SPJ - 5429 or Equivalent like Mark, Grohe. ) |
| 139 | Supplying Fitting Fixing Shower Arm with all accessories (Make jaguar model no.SHA-477 or Equivalent like Mark, Grohe. ) |
| 140 | Supplying Fitting Fixing Shower with all accessories (Make jaguar model no.OHS - 1759 or Equivalent like Mark, Grohe. ) |
| 141 | Providing and fixing oval shaped counter top Wash basin with cutting and making good the wtherever require all complete. |
| 142 | (a)BASIN - CAT. NO. - JAQUAR, FLS-WHT-5931 (WITH RIM TOP) 520x360x125 +10% C.P |
| 143 | (b)PILLAR TAP - KUP- 35001PM,JAQUAR+10% CP |
| 144 | Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms |
| 145 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm,78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 146 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketedpipes. |
| 147 | (a) 110 mm dia |
| 148 | (b) 75 mm dia |
| 149 | Making holes in walls for laying H.C.I Pipes and restoring the same after pipe laying as per specification and direction of E/I. |
| 150 | (a) 250 mm thick wall |
| 151 | (b) RCC chajja |
| 152 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms |
| 153 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. |
| 154 | Supplying materials and labours for constructing inspection chamber of designation class 100B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x450mm C.I . Cover with frame (weight not less than 39 Kg ) alongwith earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I |
| 155 | Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe . |
| 156 | 250 mm dia. R.C.C. pipe |
| 157 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length |
| 158 | Providing and Fixing Hand Shower ( Health Faucet) ( ABS Body) ALD-CHR-585 Jaquar made.Hand Shower with 1 meter Long Easy Flex Tube in Chrome Finish & Wall Hook. |
| 159 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 160 | Coupler 75 MM |
| 161 | Coupler 110 MM |
| 162 | Single pushfit Coupler |
| 163 | 75 MM |
| 164 | 110 MMSingle pushfit coupler |
| 165 | Single tee with door |
| 166 | 75X75X75 MM |
| 167 | 110X110X110 MM |
| 168 | Single tee without door |
| 169 | 75X75X75 MM |
| 170 | 110X110X110 MM |
| 171 | Bend 87.5° |
| 172 | 75 MM Bend |
| 173 | 110 MM Bend |
| 174 | 75 MM |
| 175 | 110 MM Shoe |
| 176 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board |
| 177 | 510x1040 mm bowl depth 225 mm |
| 178 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 179 | 150 mm diameter |
| 180 | Section - IIISeptic tank & Soak pit |
| 181 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro |
| 182 | Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B) |
| 183 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe |
| 184 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 185 | Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 186 | Providing designation 75A brick work inC.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri |
| 187 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out |
| 188 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 189 | Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 190 | R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 191 | Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 192 | Providing 12mm thickcement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 193 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 194 | Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 195 | Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet |
| 196 | Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio |
| 197 | (a) 10 mmTMT bar FE 500 ( Only Valid for SAIL & TATA Steel ) |
| 198 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter |
| 199 | Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg). |
| 200 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 201 | (b) Bricks |
| 202 | (c) Coarse Sand |
| 203 | (d) Stone Chips |
| 204 | (e) Cement |
| 205 | (f) Steel |
| 206 | Section-IV Electrical Installation Work |
| 207 | Note- (i)PVC insuleted copper conductor cable of make:-Havell\"s/HPL/KEI/Polycab(ii)PVC conduit of thikness 1.5mm/2mm for wiring:-Polycab/Klinga/Saini star(iii)Switches/soket outlet for piano type:-Anchor/ Cona/Keny(iv)Switches/soket outlet for modular type:-Roma(Anchor/wood)/Havell\"s(carbtree)/ Hpl/Philips(v)MCB-DB, Mccb,Mcb,SFU,Changeover,Rccb:-Havell\"s/Hpl/L&T/Legrand(vi)XLPE/PVC aramoured cable:-Havell\"s/polycab/capital/V-guard(vii)Electrical fitting/fixtures:-Bajaj/Philips/Crompton/wipro/Hpl(viii)All internal wiring work should be recessed(conseeld) |
| 208 | Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 209 | Group- A |
| 210 | Group- B |
| 211 | Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVCInsuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required. |
| 212 | Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 213 | S/F light plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.(For 5A separate & Wall fans) |
| 214 | S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. (For power & AC) |
| 215 | P/F MV Danger Notice Plate:- Providing and fixing M.V. danger notice plate of 200mmX150mm, made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in the single red colour on front side as required. |
| 216 | Circuit/Sub-main wiring in PVC Conduit:-Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 217 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire(6A Separate sockets from nearest switch board) |
| 218 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit.and for all 6A separate sockets for LAN Out lets- 3/4 sets of out lets shall be in one circuit) |
| 219 | 2x6 Sq.mm + 1x6 Sq.mm earth wire (for Geyser points) |
| 220 | 4x6 Sqmm + 2x6 sqmm earth wire (for LDB & PDB DB) |
| 221 | 4x10 Sqmm +2x10 sqmm earth wire (for PDB) |
| 222 | S/F of MCCB in cubical panel board:- |
| 223 | Providing and fixing following rating and capcity four pole MCCB in existing cubicle panel board, including drilling holes in cubicle panel, making connections, etc. as required. |
| 224 | 125A 16kA F/P Fixed thermal setting MCCB (Incomer for VTPN DB for Power) |
| 225 | 25/100A 16kA F/P Fixed thermal setting MCCB (Incomer for VTPN DB for Light) |
| 226 | S/F TP MCB DB: Supplying and fixing following way, three pole and neutral sheetMCB distribution board, 415 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder paintedincluding earthing etc. as required ( But without MCB/RCCB/ ISOLATOR). |
| 227 | 4 Way (4+12), Double Door (Horizontal Type). |
| 228 | S/F Vertical Type T.P. MCB DB:- Supplying and fixing following way, three pole and neutral, sheet, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). Note:- Vertical type MCB TPDB is normally used where three phase outlets are required. Make- L&T/Legrand/Schneider. |
| 229 | 4 way (8+12) Double Door, Vertical type |
| 230 | MCB & MCB DB\"SS/F \"B\" series, S.P. MCB:Supplying and fixing 6 amps to 32 amps, rating, 240 volts, \"B\" series, maniature circuit breaker of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required . |
| 231 | 6/32 amps, Single pole, \"B\" series |
| 232 | S/F \"C\" series MCB:-Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 233 | 6/32A Single Pole |
| 234 | 6/32 amps. DP. (to use as incomer in SP MCB DB) |
| 235 | 40 amps,TPN |
| 236 | 50/63A TPN |
| 237 | S/F Ceiling Rose:- Supplying andfixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. (to be provided for all Tube lights , mirrior lights and fans) |
| 238 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 239 | S/F Electonic Musical Call Bell:-Supplying and fixing electronic musicalcall bell suitable for D.C./A.C. single phase, 230Volts, complete etc as required. |
| 240 | Erection on incandececent light fitting :-Erection of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS amps per fitting, complete with all accessories including connectionetc as required. (For mirror lights & round circular surface mounted light fittings) |
| 241 | ITC fluorescent fitting directly on surface:-Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 242 | ITC Ceiling Fan :-Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required. |
| 243 | S/F Modular type electronic fan regulator: Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 244 | ITC Exhaust Fan upto 450 mm sweep:-Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage,including connection, testing, commissioningetc as required. |
| 245 | P/ F G.I. Lightning conductor tape in horizontal run :- Providing and Fixing G.I. Lightning Conductor Tape In Horizontal run: Providing and fixingof coppertape20mm x 3mm thick on parapet or surface of wall for lightning conductor completeetc. as required (horizontal run). |
| 246 | P/ F G.ILightning conductor tape in vertical run :- Providing and Fixing G.I. Lightning Conductor Tape In vertical run: Providing and fixingof copper tape20mm x 3mm thick on parapet or surface of wall for lightning conductor completeetc. as required (vertical run). |
| 247 | S/F PVC conduit :-supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 248 | 20mm |
| 249 | 25 mm |
| 250 | Telephone Wiring in Existing Conduit:- Supplying and drawing, following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required. |
| 251 | 2 pair |
| 252 | S/F Modular type Switch / Socket:-Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections butexcluding modular plate etc as required. |
| 253 | Telephone socket outlet(1 modules) |
| 254 | TV antenna socket outlet(1 modules) |
| 255 | 5/6 amps one way switch (1 Modules) |
| 256 | 15/16 amps, one way switch |
| 257 | 5/6 amps 3 pin socket out let (2 modules) |
| 258 | 15/16 amps 6 Pin Shocket out let(2Modules) |
| 259 | S/F Modular boxes, base and cover plate:- |
| 260 | Supplying and fixing following size /modules G.I. box along with modular base and cover plate for modular switches in recess etc. as required |
| 261 | 1 or 2 modules (78mmx78mmx45mm) (to be used for Tel, Data out lets) |
| 262 | 4/5 modules (78mmx140mmx50mm) (to be used for 2 Nos. 5/6A Sockets & with 1 No. 16 A Switch for LAN OUT LET POWER SUPPLY) |
| 263 | 6 module(78mm x 205mm x 50mm) |
| 264 | 8/9 module(78mm x 230mm x 60mm) |
| 265 | TV cable in Existing Conduit:-Supplying and drawing, co-axial TV cable RG-6 grade copper conductor, PE insulated with PVC sheath in the existing surface/ recessed steel / PVC conduit as required. |
| 266 | MV cable laying upto 95 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 267 | MV cable laying upto 185 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 95 sq.mm.but not exceeding185 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 268 | S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1) |
| 269 | 16 sq mm , 2core |
| 270 | 70 sq mm , 3.5 core |
| 271 | 95 sq mm , 3.5 core |
| 272 | 120 sq mm , 3.5 core |
| 273 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 274 | 4 X 16 sq. mm (28mm) |
| 275 | 3½ X 70 sq. mm (38mm) |
| 276 | 3½ X 95 sq. mm (45mm) |
| 277 | 3½ X 120 sq. mm (45mm) |
| 278 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 279 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (23AWG Cable) Make- Legrand-,Schneider- Actasis, Optronix |
| 280 | 9U Rack |
| 281 | Patch Panel |
| 282 | I/O Box |
| 283 | 1 or 2 Module Gang box |
| 284 | Krone Box :- |
| 285 | Providing, fixing, connecting & testingof Krone box (Telephone Tag Block) in athermoplastic, IP 65 (weather proof) enclosure, internally embedded gasket, anti corrosive, insulated and shock proof with provision for cable through IP 65 glands complete in all respects. (Make : Seimens/Metrix/Avaya/BPL. |
| 286 | 20 pair Tag (Krone)Box (136 mm x 253 mm x 115 mm) |
| 287 | 9/10 watt LED Bulb |
| 288 | LED Battern (10/12w)conforming to IEC62722 |
| 289 | LED Battern (20/22w)conforming to IEC62722 |
| 290 | Recess mounting led round down light (15/16 w) IEC627722 or IS 10322 part 5/section 2 |
| 291 | Supply of fancy wall light fixture with 12W LED Bulb. (Make:- Philips-915004110601 / Equivalent in Bajaj / Havells) |
| 292 | Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/jaquar/crompton |
| 293 | S.I.T.C of floowing rating LED street lighting luminarie with pressure die cast housing and toughened glass cover ,IP 66 protection ,LUMINIOUS EFFICARY >110 LM/W,with lens in existing pole/pipefor supply voltage 100-270V AC,50Hz Luminate shall be confirm to IS 10322 part 5/section 3 and shall be complete with all necessary accessories as required |
| 294 | 90/100W LED street light |
| 295 | Supply Installation , testing and communiting of following size celling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm FR PVC imsulated , copper wire suitable for 230V 50 HZ, single phase supply etc. complete as required |
| 296 | 1200mm (48\")Celling fan |
| 297 | 16\" 400mm wall mounted fan |
| 298 | Providing of 12\"\" (300 mm)exhaust fan of make bajaj/havells/usha/crompton |
| 299 | Main Panel : Supplying fixing testing commissioning of 16 swg crca sheey steel panel box including painting, copper wiring, CT,PT,digital ampmeter,volt meter,copper basbar(40mmx6mm) 3 set, MCCB 4 pole 35 KA 1No,MCB 4 POLE 63 AMP 4 Nos,MCCB 4POLE 40 AMP 5 Nos,DP 40 AMP3 NOs,SP 16 AMP 2 NOs,contactor 4 pole 80 amp 1no, contractorh4 pole 63 amp 1no,slector switch 2nos,surge protectin device 1 nos, push botton 2 nos, RYB INDICATOR 3 NOs, etc as required |
| 300 | 16A 2 ModuleAC Starter Switch :-Supplying and fixing 16 A 240 volts 2 moduleAC Starter switch (with Red & Green push bottom) in existing G.I.Box with front plate in recess, to be installed in different switch boardas shown in drawing and complete with connections, testing and commissioning etc. as required. Make:-Legrand (Arteor) / Schneider (Zencelo) / MK (Blenz) (to be installed near switch board. |
| 301 | Section-VDEEP BORE WELL |
| 302 | Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site. |
| 303 | From 0.0M to 50.0 M belew G.L |
| 304 | From 51.0 M to200.00 M belew G.L |
| 305 | supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job. |
| 306 | Cleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc. |
| 307 | Supplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I . |
| 308 | Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. |
| 309 | Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages2.0 HP |
| 310 | Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914.F.A.S.D. Starter |
| 311 | FR PVC insulated 3 core 4 sq.mm. copper wire. |
| 312 | 2no heavy duty clamp 40mm dia duitable for pipe with all complet job. |
| 313 | Supplying & lowering 40mm da column G. I. pipe with all complete job. |
| 314 | Section VI Rain Water Harvesting |
| 315 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 316 | Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B) |
| 317 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 318 | Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I |
| 319 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 320 | Providing designation 75A brick work inC.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 321 | Stone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I.90 mm Gravel filling |
| 322 | 0.90 M stone Boulder filling |
| 323 | Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 324 | Providing 12mm thick cement plaster (1:3) with clean coarse sand ofF.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as perbuilding specification and direction of E/I. |
| 325 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 326 | Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel ) |
| 327 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 328 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 329 | 110 mm bend |
| 330 | Shoe 110 mm |
| 331 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand)and making good the wall etc. complete(110 mm ) |
| 332 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 333 | (b) Bricks |
| 334 | (c) Coarse Sand |
| 335 | (d) Stone Chips |
| 336 | (e) Cement |
| 337 | (f) Steel |
| 338 | Basic rate for 125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making125/115 mm dia boring etc and cost of transporting rigmachine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate) |
| 339 | Drilling upto 30 M depth below G.L in Rulararea |
| 340 | Drillingbeyond 31 mtr upto 55 mtr below GL in Ruralarea |
| 341 | Supplying all materials labours equipments for lowering 125 mm dia blue UPVC Casing Pipe as casing for protecting the sides from falling during the process of drilling all complete including carrriage of materials to work site (Basic Rate) |
| 342 | S/M/L forF/f wire mesh pipe |
| 343 | Section VII APPROACH ROAD (50 Metre)leangth |
| 344 | Excavation in Soil by Manual means. (Excavation for foadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.)(ii) Including Royalty @ Rs. 27.48 per cumthe cost of watering, rolling & compaction |
| 345 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 346 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 347 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 348 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 349 | (b) Bricks |
| 350 | (c) Coarse Sand |
| 351 | (d) Stone Chips |
| 352 | (e) Cement |
| 353 | Add 18% GST |
| 354 | Add 1% Lebour Cess |
AI Tender Summary
Tender Timeline
Feb 06, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 16, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 17, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender