Tender For Repair/Routine Maintenance Of Dg Sets, Amf Panels And Other Misc E/M Installation At Af Stn Faridabad In Aor Of Ge (Af) Faridabad, faridabad-Haryana

Military Engineer Services-MES has published Tender For Repair/Routine Maintenance Of Dg Sets, Amf Panels And Other Misc E/M Installation At Af Stn Faridabad In Aor Of Ge (Af) Faridabad. Submission Date for this Tender is 09-03-2024. Diesel Generators Tenders in faridabad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42040816
Corrigendum : Tender For Repair/Routine Maintenance Of Dg Sets, Amf Panels And Other Misc E/M Installation At Af Stn Faridabad In Aor Of Ge (Af) Faridabad
Open Tender
Indian
Haryana
faridabad
09-03-2024

Tender Details

Repair/Routine Maintenance Of Dg Sets, Amf Panels And Other Misc E/M Installation At Af Stn Faridabad In Aor Of Ge (Af) Faridabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Feb-2024 Date Date 01-03-2024
2 21-Feb-2024 Sch of credit Terms and Conditions 02-03-2024
3 21-Feb-2024 BOQ BOQ 02-03-2024
4 21-Feb-2024 Date2 Date 02-03-2024
5 02-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work :REPAIR/ROUTINE MAINTENANCE OF DG SETS, AMF PANELS AND OTHER MISC E/M INSTALLATION AT DIFFERENT LOCATIONS IN AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1M&L for General Servicing ofDG sets upto 160 KVA , at run of 500 hours or 5 months which ever comes first(twice in Contract period based on condition ) comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine, Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing etc. as reqdcomplete all as specified and directed by Engineer-in-Charge. Note - Servicing through OEM authorised rep or service engineer from the manufacturer only and Cost of unserviceable items will be measured and paid seperately under relevant items. (a) S&Flubrication of oil filter (b) S&Fby pass filter (c) Cleaning of hydraulic governer (d) S&F Checking and toping up of coolant (e) S&F fuel filter (f) S&F air cleaner element (g)S&F in Air filter (h) Cleaning of radiator complete set (j) Engine oil as per manufacturer specification and any other checking as per manufacturer instruction
2All as per item No1 above but capacity ofDG set 100 KVA
3All as per item No1 above but capacity ofDG set 82.5 KVA
4All as per item No1 above but capacity ofDG set 62.5 KVA
5All as per item No1 above but capacity ofDG set 25 to 40 KVA
6Supply only the following items of DG Set of various capacity complete all as specified and directed by Engineer-in-Charge.
7All as per item No 06 above but Battery terminal, lug, bolts type suitable for heavy duty battery 12/24 V.
8All as per item No 06 above but Battery leads copper conductor multi wired 35 Sqmm.
9All as per item No 06 above but Hinges for DG set door of any size, any type as required on site.
10All as per item No 06 above butServo cool plus Radiator coolent
11All as per item No 06 above but Low viscosity synthetic Engine oil 15W40
12M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins bydescaling solution andusing air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer, leak check andpressure testing including transporting to repair workshop and bringing back for upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
13All as per item No 12 above but capacity from 82.5 KVA upto 200 KVA
14Supply, replacment and testing of radiator assembly of DG Set 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
15Supply, replacment and testing of radiator assembly of DG Set 82.5 KVA complete all as specified and directed by Engineer-in-Charge.
16Supply and replacement of low lube oil pressure sensor upto 160 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
17Supply and fixing in repair of Water Pumpof Radiatorsuitable for DG set Radiator up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
18All as per item No 17 above but capacity from 82.5 KVA upto 200 KVA
19M&L for Removal & replacement offly wheel gear ring suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
20All as per item No 19 above but capacity from 82.5 KVA upto 200 KVA
21M&L for Removal & replacement of thermostat suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
22All as per item No 21 above but capacity from 82.5 KVA upto 200 KVA
23Supply and fixing in repair of AVR for DG set having capacity 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
24All as per item No 23 above but capacity from 82.5 KVA upto 200 KVA
25Supply and fixing in all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittingssuitable for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
26All as per item No 25 above but capacity from 82.5 KVA upto 200 KVA
27S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 100 KVA complete all as specified and directed by Engineer-in-Charge.
28Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etcsuitablefor smoothing functioning of DG set asrequired on site complete all as specified and directed by Engineer-in-Charge.
29All as per item No 28 above but capacity Battary Charger 24V DC, 10 Amp complete all as specified and directed by Engineer-in-Charge.
30Supply only distilled water for top up inBatteries complete all as specified and directed by Engineer-in-Charge.
31Supply only electrolyte battery solution (Dilute sulphuric acid have specific gravity 1210 degree) in 10 litrs sealed gallon packing complete all as specified and directed by Engineer-in-Charge.
32Supply & Fixing in DC 12V Stop Solenoid Coil suitable for DG Setcomplete all as specified and directed by Engineer-in-Charge.
33Supply & Fixing in DC 24V Self Solenoid Coil suitable for DG Setcomplete all as specified and directed by Engineer-in-Charge.
34Supply and replacement of Bty 12 Volt 100 AHsuitableDG set complete all as specified and directed by Engineer-in-Charge.
35Supply and replacement of Bty 12 Volt 180 AHsuitableDG set complete all as specified and directed by Engineer-in-Charge.
36M&L for repairing of self starter of DG setcapacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed by Engineer-in-Charge.
37All as per item No 36 above but capacity 24 Volts complete all as specified and directed by Engineer-in-Charge.
38S & FCopper Battery leds suitable for Bty 12V complete all as specified and directed by Engineer-in-Charge.
39Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
40All as per item No 39 above but capacity from 82.5 KVA upto 200 KVA complete all as specified and directed by Engineer-in-Charge.
41M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation complete all as specified and directed by Engineer-in-Charge.
42Supply and fixing in repair IOPS Module digital display controller unit suitable for exisitng DG Set complete all as specified and directed by Engineer-in-Charge.
43S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
44S&FMCCB 3 pole 415 volts in repairs,fixed type 63 Amps to100 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
45S&F in repairs MCCB 3 pole 415 volts fixed type 200Ampswith braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
46S&F in repairs MCCB 3 pole 415 volts fixed type 250Ampswith braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
47S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
48S&F for fuel pipe from fuel tank to fuel filter for DG Set 82.5 KVA to 200 KVA complete all as specified and directed by Engineer-in-Charge.
49Supply, fixing andtesting of charging alternator 12 V/24V complete all as specified and directed by Engineer-in-Charge.
50Supply and fixing mounting rubber bushing set of 6 for existing generator complete all as specified and directed by Engineer-in-Charge.
51S&F MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
52S&F Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed by Engineer-in-Charge.
53S&F Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed by Engineer-in-Charge.
54M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF pael etc complete all as specified and directed by Engineer-in-Charge.Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penaltyof Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock.
55Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of 62.5 KVA capacity three phase 415 Volts, 50 HZ AC including internal wiring with suitable copper conductor with thimbles, timer, relay, MCB 6 Nos- 10 Amps, VMR 3 pole - 02 Nos, battery charger 12 V - 01 No, Motorised changeover switch CX3 160 Amps, Volt meter/Ammeter, RYB phase indicators(DG and Mains), selector switchs etc including fixing with PCC work in floor alongwith suitable angle iron frame for AMF panel complete with all standard features, safeties etc complete all as specified and directed by Engineer-in-Charge.
56M&L spray gun painting of generator upto 62.5 KVA in existing colour with smooth finishing complete all as specified and directed by Engineer-in-Charge.
57M&L spray gun painting of generator 82.5 KVA upto 160 KVA in existing colour with smooth finishing complete all as specified and directed by Engineer-in-Charge.
58M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 25×4mm as earthing lead by means ofbolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire meshand 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and directed by Engineer-in-Charge.
59Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
60Material and Labour for fixing white boards 5" x 4" as per site details ofLine digram / Machine History /Distribution boards complete all as specified and directed by Engineer-in-Charge.
61M&L for repair maintenance of Steel rolling shutters greasing and sythetic enemal paint blue / black colour, includingball bearing,anchoring rod, hasp and staple push pull or manual type as per site requirement complete all as specified and directed by Engineer-in-Charge.
62Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting outcomplete all as specified and directed by Engineer-in-Charge.
63Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cmapart complete all as specified and directed by Engineer-in-Charge.
64Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
65Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed by Engineer-in-Charge.
66Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mmcomplete all as specified and directed by Engineer-in-Charge.
67Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 240 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
68Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 185 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
69All as per item No 68 above but Size 95 sqmm 3.5 core
70All as per item No 68 above but Size 70 sqmm 3.5 core
71All as per item No 68 above but Size 50 sqmm 3.5 core
72All as per item No 68 above but Size 35 sqmm 3.5 core
73All as per item No 68 above but Size 25 sqmm 4 core
74All as per item No 68above but Size 16 sqmm 4 core
75All as per item No 68 above but Size 10 sqmm 4 core
76Supply and Fix cable jointing kit,heat shrink type for 1100 volts grade,XLPE insulated armoured heavy duty electric cable with aluminium conductor,cross sectional area 6-16 Sqmm 4 core complete with jointing material and accessories including testing complete all as specified and directed by Engineer-in-Charge.
77All as per item No 76 above but Size 25-35 sqmm 4 core.
78All as per item No 76 abvoe but Size 50-95 sqmm 3.5 core.
79All as per item No 76 above but Size 120 - 185 qmm 3.5 core.
80S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers complete all as specified and directed by Engineer-in-Charge.
81S&F MNX 18, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
82S&F MNX 70, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
83S&F Panel LED indication lamps (R/Y/B) complete all as specified and directed by Engineer-in-Charge.
84S&F Rotary switch of existing make L&T complete all as specified and directed by Engineer-in-Charge.
85S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
86S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
87S& F in capacitor 3 phase, 5 KVAR complete all as specified and directed by Engineer-in-Charge.
88S& F in capacitor 3 phase, 10 KVAR complete all as specified and directed by Engineer-in-Charge.
89S& F in capacitor 3 phase, 25 KVAR complete all as specified and directed by Engineer-in-Charge.
90S& F in capacitor 3 phase, 2 KVAR complete all as specified and directed by Engineer-in-Charge.
91S& F in capacitor 3 phase, 3 KVAR complete all as specified and directed by Engineer-in-Charge.
92Supply and install reactive power manager in existing APFC panelcomplete all as specified and directed by Engineer-in-Charge.
93M&L for servicing/testing of APFC(Automatic Power Factor Control) panel including checking of all internal connetions and replacement of spares if required complete all as specified and directed by Engineer-in-Charge. Note - Spares to be measured and paid separately
94M & L for High quality powder coating on electric panels (Cubicle) installed at different places with synthetic enamel paint of suitable colour including and after scrubbing all body surface to get all foreign particles removed off,applying one coat of metal primer by disconnecting,removal of all accessories like bas bar, CTs,MCCBs and all wirings,equipments and refix with new Gun metal nut,bolt and washer complete with new copper lead wiring complete all as specified and directed by Engineer-in-Charge.
95Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine withHDPE Pipe, PN 10,100 mm dia complete all as specified and directed by Engineer-in-Charge.
96Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenchesduly painted with two coat of black metallic paint after aprimer coat of red oxide complete all as specified and directed by Engineer-in-Charge.
97All as per item No 96 above but 50 mm dia
98All as per item No 96 above but 40 mm dia
99Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed by Engineer-in-Charge.
100Material and Labour for servicing of split type AC"s of capacity 1.5/2 TR comprising of the following tasks installed at different locations includingtesting complete all as specified and directed by Engineer-in-Charge. (a) Inspecting and checking the Indoor/outdoor units for noise free operation. (b)Checking the electrical connection for tightness (c)Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower with water pressure gun. (d)Greasing/Oiling of condenser fan motor and blower motor. (e)Checking for any refrigerant leakage by pressure testing and repair it. (f) Checking for serviceability of remote control unit and replace with new battery.
101Supply and fixing in replacement of starting relay 25 Amps for split type AC units of capacity 2 /1.5TR as required at site complete all as specified and directed by Engineer-in-Charge.
102Supply and fixing in replacement of start run capacitor 45/60 MFD for split type A/C"s of capacity1.5/2 TR complete all as specified and directed by Engineer-in-Charge.
103Taking out and replacement ofcondenser fan motor DC of split type AC 1.5/2 ton units of capacity 1.5/ 2 TR complete all as specified and directed by Engineer-in-Charge.
104Taking out and replacement ofcondenser fan motor AC of split type AC units of capacity 1.5/ 2 TR complete all as specified and directed by Engineer-in-Charge.
105S & F PCB card with display unit suitable of 1.5/2 ton split ACindoor unitas required on sitecomplete all as specified anddirected by Engr-in-Charge including replacement of defectiveelectronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge.
106S & F PCB card suitable of 1.5/2 ton inverter split AC outdoor unitas required on site including sensor complete all as specified and directed by Engineer-in-Charge.
107Supply and fix out door fan blade in existing model complete all as specified and directed by Engineer-in-Charge.
108Supply and fix indoor blower set complete all as specified and directed by Engineer-in-Charge.
109Disconnecting and taking down burnt condenser coil of capacity 1.5TR from split type AC unit and Supply and Fix new copper condesor coil as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
110Supply and replacecooling coil assembly complete suitable for1.5 / 2 tonindoor unit Split type ACincl testing for satisfactory working condition complete all as specified and directed by Engineer-in-Charge.
111Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
112Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
113Material and Labour for repair to leaking area of split type AC unit of capacity 1.5/2 TR capacity including nitrozen pressure testing, dehydration and any type ofgas charging complete all as specified and directed by Engineer-in-Charge.
114Supply & Fixing the new remote with battery as per existing model for 1.5/2 TR split type A/C unit complete all as specified and directed by Engineer-in-Charge.
115Supply & Fixing the new blower motor DC for split type A/C unit as per existing model complete all as specified and directed by Engineer-in-Charge.
116Supply and install split AC 1.5 ton indoor unit complete all as specified and directed by Engineer-in-Charge.
117Supply & Fixing the new blower motor AC for split type A/C unit as per existing model complete all as specified and directed by Engineer-in-Charge.
118S&F in replacement 3 core copper PVC insulated of size 4 Sqmm complete all as specified and directed by Engineer-in-Charge.
119S&F in replacement the new swing motor as per existing model/make for split type AC 1.5/2TR unit complete all as specified and directed by Engineer-in-Charge.
120M&L in repairs copper tubing 3/8” outer dia suitable for AC 2TR capacity complete all as specified and directed by Engineer-in-Charge.
121All as per item No 120 above but 5/8” outer dia.
122S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp complete all as specified and directed by Engineer-in-Charge.
123Supply & fixing in replacement of 3 pin socket metalic plug top industrial type complete all as specified and directed by Engineer-in-Charge.
124S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
125Supply and install Split AC 1.5 ton outdoor unit complete all as specified and directed by Engineer-in-Charge.
126Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-Charge.
127S&F in replacement ofwall mounted Voltage stabilizers 4/5 KVA single phase,230 Volts AC,voltage variation between 140- 300,intelligent time delay system,digital display,low and high voltage cut-off system, complete all as specified and directed by Engineer-in-Charge.
128Supply and fixing in replacement of wood pads(set of three)as per sample complete all as specified and directed by Engineer-in-Charge.
129Supply and fixing in replacement the new desert cooler pump.including testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
130Supply and fixing in replacement the new exhaust fan kit with leg assembly 450mm sweep complete all as specified and directed by Engineer-in-Charge.
131Supply and fixing in replacement the new exhaust fan motor with leg assembly 450mm sweep complete all as specified and directed by Engineer-in-Charge.
132Supply and fixing in replacement the new exhaust fan blade 450mm sweep, complete all as specified and directed by Engineer-in-Charge.
133Supply and fixing in replacement new body of desert cooler of 600 x 600 x 900 mm size or in next higher size in volume duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle,selector switches,swinging motor,distributor and nut bolts washers for fixing fanclamps, complete all as specified and directed by Engineer-in-Charge.
134Supply and fixing front grill of desert cooler as per sample complete all as specified and directed by Engineer-in-Charge.
135Supply and fixing PVC flexible distributor heavy duty as per sample complete all as specified and directed by Engineer-in-Charge.
136All as per item No 135 above but nozzle complete all as specified and directed by Engineer-in-Charge.
137Supply and fixing in replacement plug top 15 Amps complete all as specified and directed by Engineer-in-Charge.
138Material and Labour for servicing of window type AC"s of capacity 1.5 TR comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and directed by Engineer-in-Charge. (a) Inspecting, taking down, brushing cleaning with water pressure gun including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system by pressure test and repair it. (d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. (f) Inspection of all electrical parts. (g) Testing the machine for satisfactory operation.
139Supply & fixing in replacement of running capacitor for 36/60 mfd for AC window type 1.5 TR as required at site complete all as specified and directed by Engineer-in-Charge.
140Supply & fixing in replacement of running capacitor 6 mfd for blower motor as required at site complete all as specified and directed by Engineer-in-Charge.
141Supply and fixing in replacement of new blower motor 1 HP as required at site single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes including testing & commissioning complete all as specified and directed by Engineer-in-Charge.
142Material and Labour for repair to leaking area of window type AC unit of capacity 1.5 capacity including pressure testing, dehydration and any type ofgas charging complete all as specified and directed by Engineer-in-Charge.
143S&F "R" typecompressor for Window type AC,1.5 TR as per existing makeincluding taking out old unserviceable one,flushing, dehydrationand gas changing complete all as specified and directed by Engineer-in-Charge.
144S&F cooling coil of window type AC 1.5 TR including after taking out old unserviceable one,soldering/welding dehydrationcomplete achieve complete all as specified and directed by Engineer-in-Charge.
145Disconnecting & taking down of window type AC of any make for replacement of condenser coil of existing size including soldering/weldingand resting commissioning complete all as specified and directed by Engineer-in-Charge.
146Repair & maintenance of Refrigerator any capacitycomprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a)Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system. (d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. (f)Inspection of all electrical parts. (g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigeratorafter repair.
147M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of existingmake including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
148M & L for replacement of unserviceable compressor with new compressor of existingmake including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
149M&L Unplasticised PVC pipes 25 mm diaof pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge.
150M&LSub main wiring with two run of 4.0 sqmm single core, FRLS PVC insulated but unsheathed multistranded copper cable1100 volts conductor drawn through in and including consealed PVC conduit of25 mm dia with all accessories and 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor cable as earth continuity wire complete all as specified and directed by Engineer-in-Charge. Note: Two run of PVC cable with one run of PVC conduit and one run of PVC earth wire shall be measured and paid as one length only.
151Labour for dismantling of Split AC 1.5/2 ton complete unit from the existing place complete all as specified and directed by Engineer-in-Charge.
152Labour for fixing of Split AC 1.5/2 ton including masonary work complete unit complete all as specified and directed by Engineer-in-Charge.
153Labour for dismantling of window AC 1.5 ton from the existing place complete all as specified and directed by Engineer-in-Charge.
154Labour for fixing of window AC 1.5 ton complete all as specified and directed by Engineer-in-Charge.
155Supply and fix Ventilation fan (250 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
156Supply and fix Ventilation fan (200 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
157Taking down ceiling fan complete any type size from existing location andcleaning body blades etc including greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and directed by Engineer-in-Charge.
158All as per item No 157 above but for Exhaust fan 300 mm sweep.
159All as per item No 157 above but for Exhaust fan 450 mm sweep.
160All as per item No 157 above but for wall/floor mounted fan 450 mm sweep.
161Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from siteby strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and directed by Engineer-in-Charge.
162All as per item No 161 above butfor Exhaust fan 300 mm sweep.
163All as per item No 161 above butfor Exhaust fan 450 mm sweep.
164All as per item No 161above butfor wall/floor mounted fan 450 mm sweep.
165S&F in repairs Capacitor 2.5 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
166Supply only FR PVC electrical insulation tape,1.8 cm x 25 mtr x0.125 mm thick complete all as specified and directed by Engineer-in-Charge.
167S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail