Rate Contract Of Electrical Equipment Associated With Street Lighting In Different Industrial Areas Of Jiada ( Ranchi Region, Adityapur Region, Bokaro Region And Santhal Pargana Region ) .- 1 Street Lighting 2 Supply Of 90W Led Street Light With Pressure Die Cast Aluminum Housing & Toughened Glass / Polycarbonate With Ip- 66 Degree Of Protection, With Luminaire Efficacy Of Greater Than 100 Lumen / Watt Luminous Flux- Minimum 9000 Lm, Life Span 50, 000 Operating Hours. Colour Rendering ( Cri ) Of >70 And Co-Related Colour Temperature ( Cct ) Of 5700K ( +500K ) , The Luminaire Should Have 5Kv Internal And 10Kv External Surge Protection, Pf > 0.9, And Total Harmonic Distortion Of Thd < 10%, Voltage Range Of 110-280V Should Be Provided. Luminaire Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85% . Manufacturers To Provide Lm80 From Source Manufacturer And Should Have Own Adequate Testing Facilities Approved By Ministry Of Science ( Govt. Of India ) To Provide Lm79 Report, Which Is To Be Provided. Type Test Certificate & Tds To Be Provided As Well. 3 Supply Of 120W Led Street Light With Pressure Die Cast Aluminum Housing & Toughened Glass / Polycarbonate With Ip- 66 Degree Of Protection, With Luminaire Efficacy Of Greater Than 100 Lumen / Watt Luminous Flux- Minimum 9000 Lm, Life Span 50, 000 Operating Hours. Colour Rendering ( Cri ) Of >70 And Co-Related Colour Temperature ( Cct ) Of 5700K ( +500K ) , The Luminaire Should Have 5Kv Internal And 10Kv External Surge Protection, Pf > 0.9, And Total Harmonic Distortion Of Thd < 10%, Voltage Range Of 110-280V Should Be Provided. Luminaire Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85% . Manufacturers To Provide Lm80 From Source Manufacturer And Should Have Own Adequate Testing Facilities Approved By Ministry Of Science ( Govt. Of India ) To Provide Lm79 Report, Which Is To Be Provided. Type Test Certificate & Tds To Be Provided As Well. 4 Supply Of 45W Led Street Light With Pressure Die Case Aluminium Housing & Toughened Glass / Polycarbonate With Ip- 66 Degree Of Protection, Individual Led’S Must Have Lenses For Better Throw Across & Along The Road With Luminaire Efficacy Of Greater Than 100Lumen / Watt, Luminous Flux Minimum 3500 Lm, Life Span 50, 000 Operating Hours. Colour Rendering ( Cri ) Of >70 And Co-Related Colour Temperature ( Cct ) Of 5700K ( +500K ) , The Luminaire Should Have 5Kv Internal And 10Kv Surge Protection, Pf > 0.9, And Total Harmonic Distortion Of Thd < 10%, Voltage Range Of 110-280V Should Be Provided. Luminaire Should Have Top Maintainable Driver Compartment For Easy Access To Dirver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. Manufacturers To Provide Lm80 From Source Manufacturer And Should Have Own Adequate Testing Facilities Approved By Ministry Of Science ( Govt. Of India ) To Provide Lm79 Report, Which Is To Be Provided. Type Test Certificate & Tds To Be Provided As Well. 5 Supply Of Hot Dip Galvanized Octagonal Pole Of Standard Specifications ( Pole Top Dimension 70Mm & Bottom Should Be 130Mm With Sheet Thickness Of 3Mm ) For Street Lighting, 7M High Spaced 20M Apart 1.0 Mtr Sword Type Single Arm Bracket Overhang Fixed Firmly In Concrete Foundation With M20x700 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. A ) M20x700 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. B ) Bakelite With 1 No. 10A Sp Mcb & Stud Type Terminal Block Suitable For 4C X 16 Sq.Mm Cable.C ) Sword Type Single Arm Decorative Bracket Of 1.0 Mtr In Length, Casting Of Foundation For 7M Poles Including Excavation Of Pole Pit. The Concrete Mix For Rcc Foundation Of Octagonal Pole Shall Be M20. The Scope Shall Also Include Grouting Of Foundation Bolts Including Curing & Provision For Passage Of Cable ( In The Foundation ) And Finishing The Surface. 6 Supply Of Hot Dip Galvanized Octagonal Pole Of Standard Specifications ( Pole Top Dimension 70Mm & Bottom Should Be 130Mm With Sheet Thickness Of 3Mm ) For Street Lighting, 7M High Spaced 20M Apart 1.0 Mtr Sword Type Double Arm Bracket Overhang Fixed Firmly In Concrete Foundation With M20x700 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. A ) M20x700 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. B ) Bakelite With 1 No. 10A Sp Mcb & Stud Type Terminal Block Suitable For 4C X 16 Sq.Mm Cable. C ) Sword Type Double Arm Decorative Bracket Of 1.0 Mtr In Length, Casting Of Foundation For 7M Poles Including Excavation Of Pole Pit. The Concrete Mix For Rcc Foundation Of Octagonal Pole Shall Be M20. The Scope Shall Also Include Grouting Of Foundation Bolts Including Curing & Provision For Passage Of Cable ( In The Foundation ) And Finishing The Surface. 7 Supply Of Hot Dip Galvanized Octagonal Pole Of Standard Specifications ( Pole Top Dimension 70Mm & Bottom Should Be 175Mm With Sheet Thickness Of 3Mm ) For Street Lighting, 11 M High Spaced 20M Apart 1.5 Mtr Sword Type Single Arm Bracket Overhang Fixed Firmly In Concrete Foundation With M24x750 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. A ) M24x750 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. B ) Bakelite With 1 No. 10A Sp Mcb & Stud Type Terminal Block Suitable For 4C X 16 Sq.Mm Cable. C ) Sword Type Single Arm Decorative Bracket Of 1.5 Mtr In Length, Casting Of Foundation For 11 M Poles Including Excavation Of Pole Pit. The Concrete Mix For Rcc Foundation Of Octagonal Pole Shall Be M20. The Scope Shall Also Include Grouting Of Foundation Bolts Including Curing & Provision For Passage Of Cable ( In The Foundation ) And Finishing The Surface. 8 Supply Of Street Light Mounted On A Hot Dip Galvanized Octagonal Pole Of Standard Specifications ( Pole Top Dimension 70Mm & Bottom Should Be 175Mm With Sheet Thickness Of 3Mm ) For Street Lighting, 11 M High Spaced 20M Apart 1.5 Mtr Sword Type Double Arm Bracket Overhang Fitted With Led Fixture And Fixed Firmly In Concrete Foundation With M24x750 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. A ) M24x750 Long ‘J’ Type En 8 Grade Foundation Bolts Along With Template. B ) Bakelite With 1 No. 10A Sp Mcb & Stud Type Terminal Block Suitable For 4C X 16 Sq.Mm Cable. C ) Sword Type Double Arm Decorative Bracket Of 1.5 Mtr In Length, Casting Of Foundation For 11 M Poles Including Excavation Of Pole Pit. The Concrete Mix For Rcc Foundation Of Octagonal Pole Shall Be M20. The Scope Shall Also Include Grouting Of Foundation Bolts Including Curing & Provision For Passage Of Cable ( In The Foundation ) And Finishing The Surface. 9 Supply & Erection Of 3Cx2.5 Sq.Cu. Flexible Wire For Connection Of Light Fitting. 10 Erection Of 90W / 120W / 45W Street Light Fitting. 11 Supplying Of 1.1Kv Grade Pvc / Xlpe Armored Electrical Cable Withaluminum Conductor. 12 Laying Of One Number Pvc / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25Sq.Mm Direct In Ground Including Excavation Sand Cushing Protective Covering And Refilling The Trench Etch. 13 Supply & Laying Of Hdpe Pipe Of 50Mm Dia Of 6 Ka / Cm.Sq. 14 Road Cutting With Gi Pipe Of 50Mm Nb Dia For Feeder Piller. 15 Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pve / Xlpe Alumunium Conductor Cable Of 1.1Kv Grade As Required. 16 Pole Earthing - Supply & Installation Of 20 Dia 1.5M. Long Ms Road For Poles. 17 Earthing- Supply & Earthing With Gi Earth Pipe 4.5 Mtr. Long 40Mm Dia Including With Accessories And Providing Masouary Enclose With Cover Plate Having Locking Arrangagement And Watering Pipe Etc. With Charcoal. Required Gi Wire To Join To Feeder Pillar. 18 Supply & Erection Of Outdoor Type Feeder Pillar For Sl. 19 Supply Of 250 Watt Led Flood Light For High Mast With Pressure Die Cast Aluminum Housing & Toughened Glass With Ip- 66 Degree Of Protection, Individual Led’S Must Have Lenses For Better Throw Across & Along The Road, With Luminaire Efficacy Of Greater Than 100 Lumen / Watt Luminous Flex- 7680-8640Lm, Life Span 50, 000 Operating Hours. Colour Rendering ( Cri ) Of >70 And Co-Related Colour Temperature ( Cct ) Of 5700K ( +500K ) , The Luminaire Should Have 5Kv Surge Protection, Pf > 0.9, And Total Harmonic Distortion Of Thd < 10%, Voltage Range Of 110-280V Should Be Provided. Luminaire Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85% . Manufacturers To Provide Lm80 From Source Manufacturer And Should Have Own Adequate Testing Facilities Approved By Ministry Of Science ( Govt. Of India ) To Provide Lm79 Report, Which Is To Be Provided. Type Test Certificate & Tds To Be Provided As Well. 20 Supply Of 500 Watt Led Flood Light For High Mast With Pressure Die Cast Aluminum Housing & Toughened Glass With Ip- 66 Degree Of Protection, Individual Led’S Must Have Lenses For Better Throw Across & Along The Road, With Luminaire Efficacy Of Greater Than 100 Lumen / Watt Luminous Flex- 7680-8640Lm, Life Span 50, 000 Operating Hours. Colour Rendering ( Cri ) Of >70 And Co-Related Colour Temperature ( Cct ) Of 5700K ( +500K ) , The Luminaire Should Have 5Kv Surge Protection, Pf > 0.9, And Total Harmonic Distortion Of Thd < 10%, Voltage Range Of 110-280V Should Be Provided. Luminaire Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85% . Manufacturers To Provide Lm80 From Source Manufacturer And Should Have Own Adequate Testing Facilities Approved By Ministry Of Science ( Govt. Of India ) To Provide Lm79 Report, Which Is To Be Provided. Type Test Certificate & Tds To Be Provided As Well. 21 Supply & Installation Of Twin Dome Led Aviation Obstruction Lamp ( Ip - 66 ) 22 Supply And Installation Of 6 Sq.Mm Ss Wire Rope For High Mast Along With Thimbles / D Clamps Etc. 23 Supply And Installation Of Winch For High Mast Tower Double Drum Sgdd With Required Sprocket. 24 Supply And Installation Of Internal Power Tool For High Mast. 1.5 Hp Motor, 1400 Rpm With Torque Limiter And Chain ( For Connecting The Torque Limiter And Winch Sprocket ) . 25 . Dismantling Of Existing High Masts From Foundation And Bringing Down To Horizontal Position Using Crane For Installing Ss Wire Ropes Or Trailing Cables ( S ) Or For Pulley ( S ) Maintenance. 26 Installation Of High Mast Including All Accessories By Placing On Existing Foundation And Tightening The Foundation Bolts. 27 Supply Of 16 Mtr High Mast Including Civil Foundation. Mast Shall Be Internally & Externally Hot Dip Galvanized High Mast Shaft In Two Sections, Top Shaft Made Up Of 3Mm Thick And Bottom Shaft In 4Mm Thick Ht Steel Sheet Conforming To Grade S355jo, E350. The Shaft Shall Be Continuously Tapered Made Of As Per Dimension: Top Dia . - 150 Mm, Bottom Dia . - 410 Mm. Base Plate - 540Mm Dia X 30 Mm Thick Shall Be Welded ( Inside & Outside ) With Shaft. High Mast Is Structurally Suitable To Accommodate 8 Nos Led Flood Light In Symmetrical Orientation At A Wind Speed Of 50 M / S As Per Is 875. Supply Of 8Nos M30 X 850 Mm Long Bolts With Template And Anchor Plate For Fixing Of Mast With Foundation. High Mast Shall Be Supplied Along With All Accessories Like 1.5 Hp Phase Motor, Double Drum Winch, 6Mm Dia Ss Rope, 5Cx4sqmm Trailing Cable, Lightning Finial, Manual Handle, Nuts And Bolts Etc. 28 Supply Of 20 Mtr High Mast Including Civil Foundation. Mast Shall Be Internally & Externally Hot Dip Galvanized High Mast Shaft In Two Sections, Top Shaft Made Up Of 3Mm Thick And Bottom Shaft In 4Mm Thick Ht Steel Sheet Conforming To Grade S355jo, E350. The Shaft Shall Be Continuously Tapered Made Of As Per Dimension: Top Dia . - 150 Mm, Bottom Dia . - 460 Mm. Base Plate - 670Mm Dia X 30 Mm Thick Shall Be Welded ( Inside & Outside ) With Shaft. High Mast Is Structurally Suitable To Accommodate 12Nos Led Flood Light In Symmetrical Orientation At A Wind Speed Of 50 M / S As Per Is 875. Supply Of 12Nos M30 X 850 Mm Long Bolts With Template And Anchor Plate For Fixing Of Mast With Foundation. High Mast Shall Be Supplied Along With All Accessories Like 1.5 Hp Phase Motor, Double Drum Winch, 6Mm Dia Ss Rope, 5Cx4sqmm Trailing Cable, Lightning Finial, Manual Handle, Nuts And Bolts Etc. 29 Supply Of 25 Mtr High Mast Including Civil Foundation. Mast Shall Be Internally & Externally Hot Dip Galvanized High Mast Shaft In Three Sections, Top Shaft Made Up Of 4Mm Thick, Middle Shaft Made Up Of 4 Mm Thick And Bottom Shaft In 5Mm Thick Ht Steel Sheet Conforming To Grade S355jo, E350. The Shaft Shall Be Continuously Tapered Made Of As Per Dimension: Top Dia . - 150 Mm, Bottom Dia . - 460 Mm. Base Plate – 670 Mm Dia X 30 Mm Thick Shall Be Welded ( Inside & Outside ) With Shaft. High Mast Is Structurally Suitable To Accommodate 12Nos Led Flood Light In Symmetrical Orientation At A Wind Speed Of 50 M / S. Supply Of 12Nos M30 X 850 Mm Long Bolts With Template And Anchor Plate For Fixing Of Mast With Foundation. High Mast Shall Be Supplied Along With All Accessories Like 1.5 Hp Phase Motor, Double Drum Winch, 6Mm Dia Ss Rope, 5Cx4sqmm Trailing Cable, Lightning Finial, Manual Handle, Nuts And Bolts Etc. 30 Supply Of 30 Mtr High Mast Including Civil Foundation. Mast Shall Be Internally & Externally Hot Dip Galvanized High Mast Shaft In Three Sections, Top Shaft Made Up Of 4Mm Thick, Middle Shaft Made Up Of 4 Mm Thick And Bottom Shaft In 5Mm Thick Ht Steel Sheet Conforming To Grade S355jo, E350. The Shaft Shall Be Continuously Tapered Made Of As Per Dimension: Top Dia . - 150 Mm, Bottom Dia . - 540 Mm. Base Plate - 740Mm Dia X 32 Mm Thick Shall Be Welded ( Inside & Outside ) With Shaft. High Mast Is Structurally Suitable To Accommodate 12Nos Led Flood Light In Symmetrical Orientation At A Wind Speed Of 50 M / S. Supply Of 12Nos M30 X 850 Mm Long Bolts With Template And Anchor Plate For Fixing Of Mast With Foundation. High Mast Shall Be Supplied Along With All Accessories Like 1.5 Hp Phase Motor, Double Drum Winch, 6Mm Dia Ss Rope, 5Cx4sqmm Trailing Cable, Lightning Finial, Manual Handle, Nuts And Bolts Etc. 31 Construction Of Rcc Foundation For Erection Of 16 Mtr High Mast ( Detailed Specification And Drawing Shall Be Given To Engineer In-Charge Before Start Of The Work ) . 32 Construction Of Rcc Foundation For Erection Of 20 Mtr High Mast ( Detailed Specification And Drawing Shall Be Given To Engineer In-Charge Before Start Of The Work ) . 33 Construction Of Rcc Foundation For Erection Of 25 Mtr High Mast ( Detailed Specification And Drawing Shall Be Given To Engineer In-Charge Before Start Of The Work ) . 34 Construction Of Rcc Foundation For Erection Of 30 Mtr High Mast ( Detailed Specification And Drawing Shall Be Given To Engineer In-Charge Before Start Of The Work ) . 35 Supply & Installation Of Outdoor Stand Mounted Feeder Panel With 32A Tpn Mcb Incomer, With Digital Timer Switch, Auto On / Off As Per Time Set By User With Manual Override Through A Three-Way Toggle Switch. Switching On And Off Shall Be Through 25 Amp Tp Contactor. For Operation Of Raising And Lowering Mechanism Of The Mast, Tp Contactor Of 9 Amp Rating Shall Be Used. There Should Be An Overload Relay And Mcb For Raising Lowering. It Shall Be Suitable For 3 - Ph 4Wire 415V Power Supply 36 Gst 37 Labour Cess