Rajya Krishi Utpadan Mandi Parishad has published Tender For Disintegration Of Existing Hybrid Solar Power Plant And Conversion Including Supply, Installation, Testing, Commissioning Of The Same Into Ongrid Solar Power Plant At Different Mandi Yards Location.. Submission Date for this Tender is 08-02-2024. Solar Power Plants Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Solar Power Plant |
2 | S/I/T/C of On-grid smart inverter per KW with standard warranty (mention standard warranty period) along with one optimizer for every two PV module to track & monitor each PV moduleincluding MPPT Feature |
3 | Standard Warranty for On-grid inverter-12 years for Inverter, Extended warranty for On-grid invereter upto 20 years. Standard warranty for Optimizer- 25 years. |
4 | Labour charges for dismantalling of existing off grid solar plant (as per column no-3) per KW |
5 | Labour charges for Re-installation of solar plant per KW (without any accessories) |
6 | S/I/T/C of Balance of system-DCDB, ACDB, DC Cable, AC Cable per KW |
7 | S/I/T/C Net meter (with Requisite arrangements) |
8 | Transportation charges for relocation of solar panel from one location to another location per Kilometer. (Size up to 50 Kilowatt) |
9 | Avarage Salvage value of inverter per Kilowatt as per Sr. No.3 |
10 | Avarage Salvage value of Battery per Kilogram as per Sr. No.3 |
11 | Annual Operation & maintenance cost of ongrid solar plant per Kilowatt |
12 | S/I/T/C Solar Panel Polycrysteline (inlcuding structure) per KW |
13 | S/I/T/C Solar Panel Polycrysteline (exlcuding structure) per KW |
14 | Optional- Testing & submitting performance report of each solar panel (Poly crystalline solar module) at existing solar. Test report should inlcude below parameter after conducting test on each module: 1) I-V Curve Test for Solar System 2) Max. Voltage (Vpm) at Pmax, Max. Current (Ipm) at Pmax 3) Voltage at Open Circuit (Voc), Current at Short Circuit (Isc) 4) Efficiency (%) Calculation of Solar System 5) Temperature Measurement of Solar Panels 6) Irradiance Measurement of Sun Light 7) Series Resistance (Rs) Calculation of Solar Panels 8) Conversion of I-V Curve under OPC to data under Standard Test Condition (STC) based upon IEC Standard 9) Provide Operating Condition (OPC) and Standard Test Condition (STC) test reports for Verification of Solar Panel Performance (OK, or NO OK) |