Tender For Provision Of Solar Power Projects At Various Locations At Jaipur Mil Station Under Ge (S) Jaipur, jaipur-Rajasthan

Military Engineer Services-MES has published Tender For Provision Of Solar Power Projects At Various Locations At Jaipur Mil Station Under Ge (S) Jaipur. Submission Date for this Tender is 30-03-2024. Solar Power Plants Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42020366
Corrigendum : Tender For Provision Of Solar Power Projects At Various Locations At Jaipur Mil Station Under Ge (S) Jaipur
Open Tender
Indian
Rajasthan
jaipur
30-03-2024

Tender Details

Tender For Provision Of Solar Power Projects At Various Locations At Jaipur Mil Station Under Ge (S) Jaipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Feb-2024 Revised Pages of Integrity Pact and other revised pages Other 07-03-2024
2 02-Mar-2024 Date Corrigendum Date 14-03-2024
3 09-Mar-2024 corrigendum No. 03 Date 20-03-2024
4 14-Mar-2024 Amendments to tender Documents alongwith Revised Pages, Additional Pages, Additional Drawings and Revised BoQ BOQ 20-03-2024
5 15-Mar-2024 Date corrigendum Date 23-03-2024
6 15-Mar-2024 Amendment in Drawing alongwith Revised Pages, Revised Drawings and Additional Drawing Other 23-03-2024
7 19-Mar-2024 Amendments in tender Documents alongwith revised Other 23-03-2024
8 20-Mar-2024 Amendments to tender documents Other 23-03-2024
9 23-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-03-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 785000.0 /-
Tender Value
INR 9.20 Crore /-

BOQ Items

Name of Work: PROVISION OF SOLAR POWER PROJECTS AT VARIOUS LOCATIONS AT JAIPUR MIL STATION UNDER GE (S) JAIPUR
Sl. No. Item Description
1Lump sum price worked out by the Contractor for"Building works” as listed in Schedule ‘A’ Part I **Above / Below the lump sum priceinserted by the MES in Schedule ‘A’ Part-I
2Lump sum price worked out by contractor for "Internal water supply" as listed in Schedule `A" Part-II Above/below the lump sum price inserted by the MES in Schedule `A" Part-II
3Lump sum price worked out by contractor for "Internal Electrification" as listed in Schedule `A" Part-III*Above/below the lump sum price inserted by the MES in Schedule `A" Part-III
4Lump sum price worked out by contractor for "External water supply" as listed in Schedule `A" Part-IV Above/below the lump sum price inserted by the MES in Schedule `A" Part-IV
5Lump sum price worked out by contractor for "External Electric Supply" as listed in Schedule `A" Part-V Above/below the lump sum price inserted by the MES in Schedule `A" Part-V
6Lump sum price worked out by contractor for "Sewage Disposal" as listed in Schedule `A" Part-VI Above/below the lump sum price inserted by the MES in Schedule `A" Part-VI
7Lump sum price worked out by contractor for "Area Drainage" as listed in Schedule `A" Part-VII Above/below the lump sum price inserted by the MES in Schedule `A" Part-VII
8Lump sum price worked out by contractor for "Roads" as listed in Schedule `A" Part-VIII Above/below the lump sum price inserted by the MES in Schedule `A" Part-VIII
9Lump sum price worked out by contractor for "Fencing And Gate" as listed in Schedule `A" Part-IX Above/below the lump sum price inserted by the MES in Schedule `A" Part-IX
10Lump sum price worked out by contractor for "ROOF TREATMENT TO EXISTING BUILDINGS" as listed in Schedule `A" Part-XAbove/below the lump sum price inserted by the MES in Schedule `A" Part-X
11Lump sum price worked out by contractor for "AIR CONDITIONING" as listed in Schedule `A" Part-XIAbove/below the lump sum price inserted by the MES in Schedule `A" Part-X
12Lump sum price worked out by contractor for " Excavation and Earth Work WORK" as listed in Schedule `A" Part-XIIAbove/below the lump sum price inserted by the MES in Schedule `A" Part-XI
13Lump sum price worked out by contractor for "Solar Power Plant" as listed in Schedule `A" Part-XIII Above/below the lump sum price inserted by the MES in Schedule `A" Part-XIII
14Lump sum price worked out by the Contractor for Schedule `A" Part- XIV (Miscellaneous items) (rate against Srl No.15.00 to 74.00shall be quoted by the Contractor)
15External Water Supply:- S & F C-Curve MCB single pole (SP) 240 volt 06-32 amp,10 KA rupturing capacity, ISI marked, for inductive loadconnected through cable lugs of suitable size complete all as specified and directed.
16S & F MCB Tripple pole neutral (TPN) 63 Amps,10 KA, ISI marked, for inductive load connected through cable lugs of suitable size complete all as specified and directed .
17S & F sheet metal enclosure MCB DB TPN 4 way metal double door with IP-43 degree ofprotection suitable for 415 V (with out MCB) with and including copper bus bar, fixed flush on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed.
18Supply and fix 1 HP single Phase capacity centrigugal pump 2900 RPM motor speed , discharge flow of 5.2 m3/h suitable for underground/ water tank mounted and catering water supply to wash solar plates enclosed in the canopy for the protection from any hazard complete all as specified and directed.
19Supply and fix 2 HP 3 Phase capacity centrigugal pump suitable for underground water tank mounted and catering water supply to wash solar plates enclosed in the canopy for the protection from any hazardcomplete all as specified and directed.
20Supply and fix 3 HP 3 phase capacity centrigugal pump suitable for underground water tank mounted and catering water supply to wash solar plates enclosed in the canopy for the protection from any hazard complete all as specified and directed.
21M&L for construction of brick masonry valve pit chamber built in CM (1:4) of size 450x450x300mm(internal dimensions) including necessary excavation and earth work in soft/loose soilandMS sheet coverwithhinges welded to and including angle iron framewith lifting hook including locking arrangement and painting steel surfaces with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer and as shown in drg No. TD/2004/26 Sheet 1/3 to 3/3 complete all as specified and directed.
22Cutting of main water supply line of 80 mmfor joining of 25/50mm GI pipe duly fixed in valve chamber complete all as specified and directed.
23Supply , installation testing and commissioning outdoor type cubical panel board suitable for 3 phase 4 wire 415 V 50Hz and type tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabricated and testing process which includes seven tank pretreatment process coprising of degreasing, rinsing, derusting, rinsing, phosphatising, rinsing and passivating followed by power coated painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8623/93 comprising of the following
24OUTER SHELL:-The shell shallbe made out of 3.15 mm thick CRCA sheet, degree ofprotection for outershell will be IP-54 & MS angles section 50x50x6 mm frame factoryfabricated with front and back openable double door system lockable/openable from keys both sides having chromium plated19mm dia fancy locks, louvers air vents gaskets for natural air flow U type gasket will be used to make the outer shell completely vermin proof. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The Outer shell shall be powder coated with purepolystersiemensgrey structure RAL7032 shade. The outer shell dimensions shall be adequate to comprise inner shell complete with 75mm space all around and can be taken out when required without disturbing outer shell with a zinc metal coated stand having zinc coated not less than 100 microns.
25INNER SHELL- Inner shell shall be IP-42 Protection & made out of 2 mm thick CRCA sheet duly compartmentalized for each control gear front and back openable single door system lockable with keys from bottom side having chromium plated 19mm dia fancy lock 02 Nos. in each compartment having louvers and air vent gasket for natural airflow U type gasket shall be used to makeinner shall completely vermin proof, TPN bus bar with colour coated on F class insulators made of non hygroscopic non combustile track resistance high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of TPN bus bar.The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coated having thickness not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at bottom. The inner shell shall be powder coated siemens grey structral RAL7032 shade.
26Incoming:- (a) MCCB 63 Amps, 4 Pole, 25 KA,415 volts, 50 Hz Thermally adjustable between 70-100. - 01 No. Outgoing:- (a) MCB 32 Amps, TPN, 10 KA,415 volts, 50 Hz Thermally adjustable between 70-100.-02 Nos. (b) MCB DP 32 Amps, 10 KA, 230 Volts, Double Pole, 50 Hz, C Characteristics-01 No (c) TPN Bus bar of 100 Amps ratings with colour coded heat shrinkable sleeve (d) Digital Panel multi functional meter to measure current, voltage, frequency & power factor having programmable CT ratio. (e) Supply and fix DOL starter suitable for 3 HP capacity centrifugal pump complete all as specified and directed - 2 Nos Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
27Supply , installation testing and commissioning outdoor type cubical panel board suitable for 3 phase 4 wire 415 V 50Hz and type tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabricated and testing process which includes seven tank pretreatment process coprising of degreasing, rinsing, derusting, rinsing, phosphatising, rinsing and passivating followed by power coated painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8623/93 comprising of the followingOUTER SHELL The shell shallbe made out of 3.15 mm thick CRCA sheet, degree ofprotection for outershell will be IP-54 & MS angles section 50x50x6 mm frame factoryfabricated with front and back openable double door system lockable/openable from keys both sides having chromium plated19mm dia fancy locks, louvers air vents gaskets for natural air flow U type gasket will be used to make the outer shell completely vermin proof
28The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The Outer shell shall be powder coated with purepolystersiemensgrey structure RAL7032 shade. The outer shell dimensions shall be adequate to comprise inner shell complete with 75mm space all around and can be taken out when required without disturbing outer shell with a zinc metal coated stand having zinc coated not less than 100 microns. INNER SHELL- Inner shell shall be IP-42 Protection & made out of 2 mm thick CRCA sheet duly compartmentalized for each control gear front and back openable single door system lockable with keys from bottom side having chromium plated 19mm dia fancy lock 02 Nos. in each compartment having louvers and air vent gasket for natural airflow U type gasket shall be used to makeinner shall completely vermin proof, TPN bus bar with colour coated on F class insulators made of non hygroscopic non combustile track resistance high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of TPN bus bar.The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coated having thickness not less than 100 microns
29A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at bottom. The inner shell shall be powder coated siemens grey structral RAL7032 shade. Incoming:-(a) MCCB 63 Amps, 4 Pole, 25 KA,415 volts, 50 Hz Thermally adjustable between 70-100. - 01 No. Outgoing:- (a)MCB 25 Amps, TPN, 10 KA,415 volts, 50 Hz Thermally adjustable between 70-100.-02 Nos. (b)MCB DP 20 Amps, 10 KA, 230 Volts, Double Pole, 50 Hz, C Characteristics-01 No (c)TPN Bus bar of 100 Amps ratings with colour coded heat shrinkable sleeve (d)Digital Panel multi functional meter to measure current, voltage, frequency & power factor having programmable CT ratio. (e) Supply and fix DOL starter suitable for 2 HPcapacity centrifugal pump complete all as specified and directed.- 2 nos Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
30M&L Rotational moulded polyethylene water storage tanks 5000 ltrs water capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed and as per SSR Part I
31EXTERNAL ELECTRIFICATION:-:- Supply , installation testing and commissioning outdoor type cubical panel board suitable for 3 phase 4 wire 415 V 50Hz and type tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabricated and testing process which includes seven tank pretreatment process comprising of degreasing,rinsing, derusting, rinsing, phosphatising, rinsing and passivating followed by power coated painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8623/93 comprising of the following-
32OUTER SHELL The shell shall be made out of 3.15 mm thick CRCA sheet, degree of protection for outer shell will be IP-54 & MS angles section 50x50x6 mm frame factory fabricated with front and back openable double door system lockable/openable from keys both sides having chromium plated19mm dia fancy locks, louvers air vents gaskets for natural air flow U type gasket will be used to make the outer shell completely vermin proof. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The Outer shell shall be powder coated with purepolystersiemensgrey structure RAL7032 shade. The outer shell dimensions shall be adequate to comprise inner shell complete with 75mm space all around and can be taken out when required without disturbing outer shell with a zinc metal coated stand having zinc coated not less than 100 microns.
33INNER SHELL- Inner shell shall be IP-42 Protection & made out of 2 mm thick CRCA sheet duly compartmentalized for each control gear front and back openable single door system lockable with keys from bottom side having chromium plated 19mm dia fancy lock 02 Nos. in each compartment having louvers and air vent gasket for natural airflow U type gasket shall be used to makeinner shall completely vermin proof, TPN bus bar with colour coated on F class insulators made of non hygroscopic non combustile track resistance high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of TPN bus bar.The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coated having thickness not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at bottom. The inner shell shall be powder coated siemens grey structral RAL7032 shade.
34Incoming:- FP-3 MCCB 200 Amps, 4 Pole, 35 KA,415 volts, 50 Hz Thermally adjustable between 70-100. - 01 No. Outgoing:- (a) MCCB 100 Amps, 4 Pole, 25KA,415 volts, 50 Hz Thermally adjustable between 70-100.-02 Nos. (b) MCB DP 40 Amps, 10 KA, 230 Volts, Double Pole, 50 Hz, C Characteristics-01 No (c) TPN Bus bar of 300 Amps ratings with colour coded heat shrinkable sleeve Digital Panel multi functional meter to measure current, voltage, frequency & power factor having programmable CT ratio. Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
35Supply, install, testing and commissioning (including CPRI type test certified) factory madeLT feeder pillar boxout door type, floor mounted,compartmantalised and IP-65 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron , powder coated, having front and rear openiable hinged double door shuters with aprons for cable entryand locking arrangement complete :-
36Outgoing FP-1(a)MCCB 400 amps, 4 pole, 50 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 02 Nos. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, not less than 60 cm long mounted on insulators. (c)Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy,max demand (KW, KVA, Kvar & Amp), CT operated 415 volts, 50 Hz AC supply including CTs.-01 set. (d) On load changeover switch of 400 Amps 4 pole. (e)LED indicating lamps (R, Y & B) -01 Set.
37Incoming (a)MCCB 200 amps, 4 pole, 30 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 03 Nos. (b)MCCB100 amps, 4 pole, 30 KA , with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 No. (c) AC SPD:( TypeII,1000V 40 kA) Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
38Supply, install, testing and commissioning and testing factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK) out door type IP 65, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet 75mm x 30 mm thickMS Channelframe work, duly powder coated finish. having front and rear openiable hinged double door shuters with aprons andcable allay for cable entryand locking arrangement completeincluding provision of 65mm Godrej (freedom) lock with 2 keys. Outgoing-FP-2 (a)MCCB 200 amps, 4 pole, 35 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 Nos. "(b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400Amp, 4 pole, not less than 30cm long mounted on insulators for incomming supply 01 No. (c)LED indicating lamps (R, Y & B) -01` Set. (d)Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy,max demand (KW, KVA, Kvar & Amp), CT operated 415 volts, 50 Hz AC supply including CTs.-01 set.
39Incoming :- (a)MCCB 63 amps, 4 pole, 25 KA, with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 3No, (b)MCCB 32 amps, 4 pole, 18 KA, with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 1 No, (c) AC SPD:( TypeII,1000V 40 kA) Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
40S&F new out door (Kiosk type) type LT panel, weather & vermin proof MS sheet housing 3.15 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 200 Amp, 35/36 KA, 415 volts, thermal release, adjustable type (Ics=100%Icu) as incomer and Aluminium bus bar 400 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and directed.(Command MT)
41S&F LED solar street light 40 watt IP 65 Protection including steel tubular seweged (MS) pole with CI Base plate and finial taper plug, bolts, nuts & screws including foundation/coping complete all as directed. Product Description:- product codeNEBSSL20DC(Twin light) Lamp wattage 20W+20W Luminous flux 1900-2000 lm Dispersion angle 120 Degree Colour White power factor >0.9 Panel120 watts solar panel
42pole height 12 feet from ground level pole materialMS 2.5" diameter battery make Amaron quanta/Exide or equavalent battery type SMF (Sealed maintenance) Battery power100 AH Battery backup12Hours Solar system D2D(Dusk to Dawn) LED ComplianceRoHS,CE COLOR Temperature6500-7000K Color rendering index(CRI)>75 Lumens per watt 95-100 lm/W Driver ProtectionsShort Circuit & over voltage LED TypeCoB (Chip on board) IP Rating IP 65 Operating Temperature-20 to 60 degree Celcius
43Supply, installation testing and commissioning outdoor type cubical panel board suitable for 3 phase 4 wire 415 V 50Hz and type tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabricated and testing process which includes seven tank pre treatment process coprising of degreasing, rinsing, derusting, rinsing, phosphatising, rinsingand passivating followed by powder coated painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8623/93 comprising of the following-
44OUTER SHELL The shell shallbe made out of 3.15 mm thick CRCA sheet, degree ofprotection for outershell will be IP-54 & MS angles section 50x50x6 mm frame factoryfabricated with front and back openable double door system lockable/openable from keys both sides having chromium plated19mm dia fancy locks, louvers air vents gaskets for natural air flow U type gasket will be used to make the outer shell completely vermin proof. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The Outer shell shall be powder coated with purepolystersiemensgrey structure RAL7032 shade. The outer shell dimensions shall be adequate to comprise inner shell complete with 75mm space all around and can be taken out when required without disturbing outer shell with a zinc metal coated stand having zinc coated not less than 100 microns.
45INNER SHELL- Inner shell shall be IP-42 Protection & made out of 2 mm thick CRCA sheet duly compartmentalized for each control gear front and back openable single door system lockable with keys from bottom side having chromium plated 19mm dia fancy lock 02 Nos. in each compartment having louvers and air vent gasket for natural airflow U type gasket shall be used to makeinner shall completely vermin proof, TPN bus bar with colour coated on F class insulators made of non hygroscopic non combustile track resistance high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of TPN bus bar.The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coated having thickness not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at bottom. The inner shell shall be powder coated siemens grey structral RAL7032 shade.
46Outgoing- FP-4 MCCB 125 Amps, 4 Pole, 35 KA,415 volts, 50 Hz Thermally adjustable between 70-100. - 01 No. Incoming (a) MCCB 63 Amps, 4 Pole, 25KA,415 volts, 50 Hz Thermally adjustable between 70-100.-02 Nos. (b) MCB DP 40 Amps, 10 KA, 230 Volts, Double Pole, 50 Hz, C Characteristics-01 No (c) TPN Bus bar of 200 Amps ratings with colour coded heat shrinkable sleeve (d) Digital Panel multi functional meter to measure current, voltage, frequency & power factor having programmable CT ratio. (e) AC SPD:( TypeII,1000V 40 kA) Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
47Supply, install, testing and commissioning and testing factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK) out door type IP 65, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet 75mm x 30 mm thickMS Channelframe work, duly powder coated finish. having front and rear openiable hinged double door shuters with aprons andcable allay for cable entryand locking arrangement completeincluding provision of 65mm Godrej (freedom) lock with 2 keys.
48Outgoing-FP-5 (a)MCCB 300 amps, 4 pole, 35 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 Nos. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400Amp, 4 pole, not less than 30cm long mounted on insulators for incomming supply 01 No. (c)LED indicating lamps (R, Y & B) -01` Set. (d)Digital Load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy,max demand (KW, KVA, Kvar & Amp), CT operated 415 volts, 50 Hz AC supply including CTs.-01 set.
49Incoming :- (a)MCCB 160 amps, 4 pole, 25 KA, with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 2 No, (b)MCCB 40 amps, 4 pole, 18 KA, with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 1 No, (e) AC SPD:( TypeII,1000V 40 kA) Note:- The quoted rate includes the foundation/PCC work of the panel including coping and pedestal as per standard practise.
50SEWAGE DISPOSAL:- M&L on site LLDPE septic tank for 10 Users designed to carry sewage and sullage water , excavation in any type of soil, PCC1:4:8 below foundation, vent shaft,connection etc, complete for conventional type complete all as specified and directed Note :- excavation, earthwork, PCC shall be included in the rate quoted by the contractor. No misunderstanding shall be entertained in later stage.
51M&L Soakage wells of 1.80M dia and 3.00M depth all as pe Drawing No. CEJZ/2004/TD/S-35 Sheet No. 1/1 Complete all as specified and directed. Note :- (a) excavation, earthwork, PCC shall be included in the rate quoted by the contractor. No misunderstanding shall be entertained in later stage. (b) stone masonary shall be used in lieu of Brick masonary
52AREA DRAINAGE:- M&L for static water tank of capacity 20000 ltrsize of static water tank 3.3M dia and 2.35M depth all as per Drg No. CEJZ/2004/TD/S-22 Sheet No 1/2 to 2/2 complete as specified and directed
53ROADS:- M & L for cleaning and preparing the road surfaces for road marking with reflective thermoplastic white road marking paint conforming to BIS 3262 laid through road maarking machine in a layer painting lines,dashes , arrows, letters etc on road, pavements and the like with road marking paint, white and golden yellow of CRYSTALEX, using 5 kg material per square meter by incorporating the white glass beads for reflectivity in 100 mm width etc complete all as specified and directed.
54ROOF TREATMENT TO EXISTING BUILDINGS:- Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied water proofing & Heat reflective coating with acrylic Polymers and polyester fibres. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.Primer as recommended by manufacturers of water proofing coating is to be applied. The firm will give six year warranty of their products and same shall be applied using their authorized applicant.
55AIR CONDITIONING:- "Supply and fix voltage stablizer for automatic operations, single phase naturally aircooled indoor type & designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of +/- 2.5% and of capacity 5.0 KVA complete all as specified and directed.
56Supply, install and testing of CCTV Camera around fencing and solar power generation building. Make:- CP Plus/Sony/Panasonic Description of item as under:- 8ch dvr cp plus- 01 nos 2.4mp cp plus camera- 08 nos Hdd 4td- 01 nos Smps 12/volt - 01 nos 3+1 wire- 01 nos including other accessories and installation all as specified &directed.
57EXCAVATION AND EARTH WORK :- "supply only for clean earth for filling at site free from any types of impurities like shrubs, roots or any humus material etc from defence land of distance n. exc. 3 Km .complete all as specified and directed. Note:- BOO shall mark the excavation site within Niwaru mil station.
58SOLAR POWER PLANT :-S&F PV Modules:-Each Module consist of 535-545 wp, Mono Perc, Half Cut PV Modules, Design, Supply, Installation, Testing and Commissioning of Solar PV Module. The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards. PV modules must be tested and approved by one of the IEC authorized test centers. Module Warrantee The manufacturer should warrant the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than twenty five (25) years from the date of commisioning.All photovoltaic modules should carry a linear performance warranty from second year.The solar PV modules offered should not degrade more than 2.5% for first year onwards and not more than 0.7% from second year of its rated power. During the first 10 years and entire life span of 25 years the solar modules should not degrade more than 10% and 20% of its rated power respectively. The PV Modules should comply following IEC:- IEC 61215/BIS 14286, IEC 61646 / Equivalent BIS , IEC 62108 / Equivalent BIS , IEC 61730(Part I & II) / Equivalent BIS , IEC 61701 / BIS 61701, IEC 600068-2-68.
59NOTE: The design of Solar power plant to be vetted by Accepting Officer (Niwaru-935, Pioneer -243, Bhakrota-374, Station Furniture-374, Command MT-560) (a) To obtain 1000 KWp minimum required Numbers ofmonocrystalline silicon solar PV modules of geater than 240 Wpeachhaving efficiency more than 16% at standard test condition, fill factor more than 0.74 plant performance ratio more than or equivalent to 75%& made of high transmittivity glass and glassfront surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 240 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum & temperature 250 C will be as under- Max Peak power Pmax:>380 Wp Current at Pmax Ipm: 12.85A Voltage at Pmax Vpm: 41.64 Volt Short circuit current Isc: 13.74A Open circuit voltage Voc: 48.72 Volts
60(i) Rated output of modules shall have positive tolerance of 3-5% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 85 ± 5% with temperature -10 °C to +85°C (Cell) and should withstand wind 150 Km/Hr on the surface of the panel. (iii)PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) Each module shall have RFID tag encapsulated with Solar Cells bearing the following details. RFID reader will be provided by contractor.
61? Name of manufacturer of PV module ? Name of manufacturer of solar Cell ? Month and year of manufacture (Separated for cell & module) ? Country of origin (separately for solar cell & module) ? Peak wattage, Im, Vm and fill factor of the module. ?Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. ? Unique Serial No and model No of Module. ? I-V curve of Module
62(v)The temperature co-efficient for the module shall not be more than 0.50%/°C. (vi) Every module must have by pass diode of suitable capacity. (vii)PV module must conform to latest edition of IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-I & II for construction and testing & safety qualification & conforming to IEC 62804 PID. (viii)It shall also in conformity of latst minimum technical specifications issued by MNRE from time to time. Modules should of 72 cells configuration and should be of MNRE approved Companies/agencies in catagory/rating ""SA-1A"" "(ix) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account. (x)RFID reader to be provided by contractor.
63String inverters 255 kW. GTi 255-KT-NG-255.Three phase On Grid inverters of 255 kw. The inverters/ PCUs shall be warranted for 10 years from date of commissioning, with DC and AC side protection with built-in fuses, surge protection and filters, Heavy-duty surge protection, Operating ambient temperature range -30 to 60 ? ("-22 to 140 ?), Grid Support Reactive power at night function, LVRT, HVRT, active & reactive power control and power ramp rate control, Volt/Watt, Frequency/Watt, DC reverse connection protection, AC short circuit protection, Leakage current protection, Grid monitoring, Ground fault monitoring, Arc fault circuit interrupter (AFCI),PV String current monitoring, Reactive power at night function, Overvoltage protection DC Type II and AC Type II. Power reduction, LVRT, HVRT, Anti-islanding type. The Inverter should comply the IEC 62116. Technical Specification"s are following:- (1) Input (DC) -- Max. Input voltage - 1500 V , Rated Input Voltage - 1080 V, Start-up Voltage - 550 V , MPPT Operating Voltage Range - 500 V - 1500 V, Full Power MPPT Voltage range - 800 V - 1300 V, Number of MPPT Trackers - 12, Number of DC inputs - 24, Max. Input Current per MPPT - 30A*12, Max. Input Short Circuit Current per MPPT - 50A*12, (Niwaru-2)
64(2) Output (AC) -- Rated Output Power - 255 KW, Max. Apparent Power - 255 KVA @ 30"C / 235 KVA @ 40"C / 220 KVA @ 50"C , Max. Output Current - 184 A , Nominal Grid Voltage - 3/PE, 800 vac , Grid Voltage Range - 640 Vac - 920 Vac , Nominal Frequency - 50Hz/60Hz , Grid Frequency range - 45-55 HZ / 55-65 HZ(According to local Standard) , Active power adjustable range - 0-100% , THDI - < 3%, Power Factor - 1 default (-0.8 .....+0.8 adjustable) , Power Factor - 1 default (-0.8 .....+0.8 adjustable). (3) Performance -- Max Efficiency - 99.02% , European Weighted efficiency - 98.5% , MPPT efficiency - >99.9% , Self consumption at night - <2 W. (4) Standard -- EMC - EN 61000-6-2, EN 61000-6-4, (Under Certification), Safety Standard - IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068, (1,2,14,30)( Under Certification) ,(5) Protection -- DC Reverse polarity protection - Yes , Anti-Islanding Protection - Yes , Leakage Current Protection - Yes , Ground Fault Monitoring- Yes , PV-Array string Fault Monitoring- Yes , Zero Voltage Ride Through - Yes , DC Switch - Yes , Anti-PID Function - Optional , AFCI Protection - Optional , Protection Class/Overvoltage category - I/III , Input/Output SPD - PV: Type II Standard , AC : Type II Standard.
656) Protection -- Topology - Transformer Less , Ambient Temperature range - -30 - +60 , Relative Humidity - 0% 100% , Cooling - Smart forced air cooling , Max altitude 4000 m , Noice - <60 dB , Mounting - Wall Mount , Communication - WiFi/GPRS/RS485/PLC/Bluetooth optional , Operation data storage - 25 years , Display - LDC&Bluetooth , Self Consumption at night - <2 W , Degree of Protection - IP66 , Dimension - 1100.5 mm * 713.5 mm * 368 mm , Weight - 100 kg.
66Module Mounting Structure :- Hot dip galvanized MS mounting structures with necessary protection coatings may be used for mounting the modules/ panels/arrays. In case offeredsupport structure is of MS type then, the frames and the complete leg assemblies of the array structures shall be Hot Dip Galvanized. Thickness of galvanization will be IS-4759 or relevant standard. All nuts and bolts shall also be with suitable corrosion protection system. (b) Module Mounting Structures shall be designed to withstand the extreme weather conditions in the area. The risk coefficient factor (K1), terrain factor (K2) and topography factor (K3) shall be considered as per IS 2061-1992 and galvanised as per IS 4759 during the design of the structure. The minimum clearance of the structure from the roof level should be 300-400mm complete all as specified and directed. (Niwaru-18800, Pioneer -4800, Bhakrota-7600, Station Furniture-7600, Command MT-9200)
67DC Cables, HDPE Conduit ISI UV resistant, and supporting Accesories :- One Core 4 Sqmm Cu 1.5kV , UV protected XLPO Solar Grade Cable Type 1. IS-1554 Part-1,Temp range:- 10Deg C to +120Deg C, Voltage range-1.5KV,excellent resistance to heat, cold, water, oil, UV radiation, flexible. Life of cable-more then 25 year. Cable should be annealed Hight conduction copper conductor withXLPO insulation, UV protected. XLPO having working voltage -1500V,UV resistant for outdoor installation IS/IEC 60227/IS 694,For AC/DC cables Voltage drop= 2% limited. The DC cables from the SPV module array shall run through a UV-stabilized PVC conduit pipe of adequate diameter with a minimum wall thickness of 1.5mm. All cables and connectors for use for installation of solar field must be of solar grade which can withstand harsh environment conditions including High temperatures, UV radiation, rain, humidity, dirt, salt, burial and attack by moss and microbes for 25 years and voltages as per latest IEC standards. DC cables used from solar modules to array junction box shall be solar grade copper (Cu) with XLPO insulation and rated for 1.1kV as per relevant standards only. Cable Routing/ Marking: All cable/wires are to be routed in a HDPE Conduit ISI UV resistence and suitably tagged and marked with proper manner by good quality ferule or by other means so that the cable easily identified. In addition, cable drum no. / Batch no. to be embossed/ printed at every one meter complete all as specified and directed. (Niwaru-4700, Pioneer -1500, Bhakrota-1900, Station Furniture-1900, Command MT-1900)
68S&F MC4 CONNECTOR PAIR( MALE & FEMALE) :- Cables and wires used for the interconnection of solar PV modules shall be provided with solar PV connectors (MC4) and couplers complete all as specified and directed. (Niwaru-100, Pioneer -30, Bhakrota-50, Station Furniture-50, Command MT-50)
69Supply,fixing,testing and commissioning of DC DB with 10 Input and 10 output in pairs for protection of inveter and grid, ABS Enclosure: IP 65/67 rated polycarbonate enclosure with danger signage,DC fuse with fuse holders: 1000 V DC(16A) 10 Nos,DC MCB 16 A,FP,800V,10 Sqmm terminal with shorting link, cable glands UV protected,connectors, MCB channel, label, lugs and other accessories all specified and directed. (Niwaru-5,Pioneer -2,Bhakrota-4,Station Furniture-2, Command MT-3)
70Supply, fixing and testing of DC Cables, HDPE Conduit ISI UV resistant, and supporting Accesories :- One Core 6 Sqmm Cu 1.5kV , UV protected XLPO Solar Grade Cable Type 1. IS-1554 Part-1,Temp range:- 10Deg C to +120Deg C, Voltage range-1.5KV,excellent resistance to heat, cold, water, oil, UV radiation, flexible. Life of cable-more then 25 year. Cable should be annealed Hight conduction copper conductor withXLPO insulation, UV protected. XLPO having working voltage -1500V,UV resistant for outdoor installation IS/IEC 69947,For AC/DC cables Voltage drop= 2% limited. The DC cables from the SPV module array shall run through a UV-stabilized PVC conduit pipe of adequate diameter with a minimum wall thickness of 1.5mm. All cables and connectors for use for installation of solar field must be of solar grade which can withstand harsh environment conditions including High temperatures, UV radiation, rain, humidity, dirt, salt, burial and attack by moss and microbes for 25 years and voltages as per latest IEC standards. DC cables used from solar modules to array junction box shall be solar grade copper (Cu) with XLPO insulation and rated for 1.1kV as per relevant standards only. Cable Routing/ Marking: All cable/wires are to be routed in a HDPE Conduit ISI UV resistence and suitably tagged and marked with proper manner by good quality ferule or by other means so that the cable easily identified. In addition, cable drum no. / Batch no. to be embossed/ printed at every one meter complete all as specified and directed (Niwaru-50, Pioneer -50, Bhakrota-50, Station Furniture-50, Command MT-50)
71Supply,fix and testingofLT cable of size185 sq.mm 3.5 core , copper cable, laid in HDPE pipe of suitable size ARM XLPE Cable 1.1kV(ISI marked as per IS 7098(Part-I): 1988) complete all as specified and directed (Niwaru-50)
72Supply,fix and testingofLT cable of size 240 sq.mmsingle core 4X2 per phase , aluminium cable, laid in HDPE pipe of suitable size ARM XLPE Cable 1.1kV(ISI marked as per IS 7098(Part-I): 1988) complete all as specified and directed (Niwaru-120)
73Supply,fixing and testing 33KV XLPE cable of size 185 Sqmm 3 core armoured type IS 7098/(Part-II) 1985 complete all as specified and directed complete all as specified and directed (Niwaru-300)
74S&F of OPR-60 Early stremer Emission (ESE) lightening protection air terminal with NFC - 17- 102 standards complete all as specified and directed (Niwaru-1,Pioneer -1,Bhakrota-1, Station Furniture-1, Command MT-1)
75S&F stainless steel mounting mast of 3 meter height with guy wire and suitable base plate should have been provision for proper fixing of mast including PCC (1:2:4) type B-1 work for grouting of mast on roof complete all as specified and directed. (Niwaru-1, Pioneer -1,Bhakrota-1, Station Furniture-1,Command MT-1)
76S&F of lightening flash counter working electro mechanically with out any power supply equipment should count lightening strokes of 0.4 KA to 150 KA complete all as specified and directed (Niwaru-1, Pioneer -1, Bhakrota-1,Station Furniture-1,Command MT-1)
77Supply and fix of LT single core PVC insulated unarmoured70 sqmm copper cable down conductor with suitable mounting accessoreis complete all as specified and directed. (Niwaru-10, Pioneer -10, Bhakrota-10, Station Furniture-10, Command MT-10)
78Supply, install, testing (including CPRI type test certified) and commissioningLT feeder pillar box (KIOSK) out door type, floor mounted,compartmantalised and IP-54 suitable for 415 Volts, 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar chamber. The panel shall be dust and vermin proof made of 3.15 mm CRCA MS sheet and with base frame of 40x40x6 mm angle iron, powder coated, having front and back openable hinged double door shutters with aprons for cable entryincluding PCC foundation as specified and directed with locking arrangement complete as follows: - (For Niwaru-01)
79(a) ACB, manual draw out type 1000 amp, 4 pole, 50 KA, with micro processored based release with integral over load, short circuit & earth fault & neutral protection, 50 Hz, 415 volts grade - 01 No. (b)Digital volt and ammeter with selector switch and CT"s set - 01 Set (c)LED indicating lamps (R, Y & B) -01 Set. (d) Earth fault module (e) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, not less than 60 cm long mounted on insulators for outgoing supply. (f) PCC foundation for the mounting base. (g) AC SPD:( Type II,1000V 40 KA) Note: The quoted rate includes PCC foundation work or the mounting base.
80Supply, install, testing for tarrif metering, combined CT PT as per RSEB (JVVNL) recommendation and testing done NABL labs as per direction of JVVNL DISCOM complete all as specified & directed. Note:- The contractor will laise with the JVVNL DISCOM for installation of CT PT without any extra cost to the deptt. (Niwaru-01, Furniture-2)
81CT:Normal system voltage (KV rms) 33, Highest system voltage (KV rms) 36,Frequency 50 Hz,Impulse withstand voltage (KVP)(on assembled CTPT set)170, One minute power frequency drywithstand voltage (on assembled CT-PT set)a) primary (KV r.m.s.)b) secondary (KV r.m.s.),One minute frequency wetwithstand voltage (KV Peak)(On assembled CT-PT set)703Root2x70 Rms,Transformation ratio (CT Ratio) 200/5 A, 150/5 A, 100/5 A, 50/5 A&25/5A, Rated output (VA burden) 15 VA,Class of accuracy 0.5S, Rated continuous thermal current 1.2 times of rated primary current,Short time thermal current 18 KA for one second for CT ratio100/5 A, 50/5 A & 25/5 A.18 KA for 3 seconds for CT ratio150/5 A & 200/5 A,Rated dynamic current 2.5 times of short time thermal current rating, Number of cores One,Instrument security factor Not exceeding 5,Max. ratio error As per IS:2705/ 1992xiv) Max. phase angle error As per IS:2705/ 1992, Max. temp. rise over max. ambienttemp. of 50 deg. C at ratedcontinuous thermal current at ratedfrequency and with rated burden.
82PT:-Nominal system voltage (KV rms) 33 Highest system voltage (KV rms) 36, Nos. of phases three Impulse withstand voltage (KVP)(on assembled CTPT set)170, One minute power frequency drywithstand voltage (on assembledCT-PT set)a) primary (KV r.m.s, secondary (KV r.m.s.),One minute frequency wetwithstand voltage (KV Peak)(On assembled CT-PT set)703Root 2x70rms, Frequency 50 Hz, Transformation ratio(PT Ratio)33 KV/ 110V, Rated output (VA burden) 30 VA per phaseix) Class of accuracy 0.5 (A s per IS:3156/1992,Winding connection Star/Star, Rated voltage factor and time 1.2 continuos and 1.9 for30 secs.,Temp.rise over max. ambienttemp.Within limits of IS:3156/1992 ,Max. Phase angle error Within limits of IS:3156/1992, Ratio error (Max.) Within limits of IS:3156/19923.05
83Supply , install , testing Net Meter as as per JVVNL Regulation(RERC - 2015)for import and export of energy to DISCOM complete all as specified & directed. Note:- (1) The contractor will laise with the JVVNL DISCOM for the installation of Solar Meters and CT PT awithout any claim to extra cost. (2) The Net Metering should be compatible to CT PT and the grid. (Niwaru-01, Furniture-2)
84Supply and fix HT 33 KV. 3 phase 50 cycles, outdoor type,totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity upto 750 MVA, overload and earth fault protection,ammeter, voltmeter and of rating upto 400 Amp.Type Porcelain Clad, Structure mounted Out Door VCB Reference Standard IEC 62271-100, IEC 62271-200 Arc quenching medium Vacuum No. of break / phase (Niwaru-01)
85One Rated voltage 33 KV Highest voltage 36 KV Frequency 50 Hz Rated normal current 1250A Breaking Capacity 25 KA for 3 sec Making Capacity 62.5 KA STC for 3 Sec. 25 KA Insulation level 36 KV/70 KV/170 KV(P) Minimum Creepage distance 900 mm Temperature rise As per IEC Operating duty cycle 0-0.3 sec – CO-3min-CO First pole to clear factor 1.5 Single phase capacitor breaking capacity As per IEC. Cable charging breaking capacity As per IEC. Minimum Pole to Pole clearance 700 mm. Closing time < 100 milli sec. Opening time < 60 milli sec. Mechanical Endurance Capacity M2 Class Electrical Endurance Capacity E2 Class Operating mechanism Motor wound spring charged stored energy. Number of Trip coil Two DC Aux. voltage 30 volt. AC Aux. voltage 230 volt. No. of spare contacts Aux Switch (NO & NC) 6 NO+6NC ( As per scheme requirement ) No. of spare contacts in Limit Switch (NO & NC) 4 NO + 4NC( As per scheme requirement ) Contact multiplier To be provided, if required for scheme requirement. Space heater 230 V AC, 80 Watt, Thermostat control. Illuminating lamp 230 V AC, 100 Watt Anti pumping Relay To be provided rated for 30 V DC Breaker control switch 3 Position, 4 Ways spring return to Neutral type. Angular movement 45º - 45º. Local Remote switch Two position, eight ways stay put type. Angular movement 90º, Current rating 16 Amps. Spring charging motor Voltage rating 230 Volt AC Degree of Protection of control cubicle IP 55 Sheet thickness of control cubicle 3 mm. 2. Vacuum Bottle Make SEIL / CGL / ABB / Siemens / BEL Rated Voltage 33 KV Normal Current 1600 Amps. Breaking Capacity 25 KA Making Capacity 62.5 KA STC for 3 sec 25 KA Minimum .
86Mechanical life in no. of operations 30000 Minimum Electrical life in no. of operations at rated current 20000 Minimum Electrical life in no. of operations at 25 KA 100 no. Dry Power Frequency withstand voltage for 1 min. 70 KV Impulse withstand voltage 170 KVp Contact Material Copper Chromium Alloy Type of plating Silver 3. Low Voltage Terminal connector Make Elmex / Connectwel / Phoenix Type Locking Stud Size Suitable for 2.5 sq. mm control wire. 4. Primary Terminal Connector Material Extruded Aluminum Size Suitable for Panther ACSR. Continuous current rating 800 Amps Nuts, bolts & washers MS hot dip galvanised. Reference Standard IS 5561 Number of connector per VCB Six number 5. Trip & Close coil Voltage & Wattage of Closing coil 30V DC, 200 Watt. Voltage & Wattage of Trip coil 30V DC, 200 Watt. 6. Control wire Make KEI/Relicab/Polycab Voltage grade 750V Size 2.5 sq.mm Colour DC Circuit : Grey AC Circuit : Phase : Red, Neutral : Black. Earth circuit : Green. 7. Earthing Terminal Material Copper Shape Rectangular Size 50 mm x 6 mm Current Rating Adequate to carry fault current. 8. Painting details Surface cleaning process 7 Tank process. Paint thickness 60-80 micron Paint shade RAL 7032 9. Accessories Spring charging handle 1 no. per set. VCB operating handle 1 no per Set. 10. Name Plate details Manufacturer To be provided Type of VCB To be provided Rated voltage 33 KV Rated current 1250 Amps Rated frequency 50 Hz Insulation level 36 KV / 70 KV / 170 KV(p) Short Circuit Breaking Current 25 KA Short Circuit withstand Current & duration 25 KA for 3 Sec. Short Circuit Making Current 62.5 KA (p) Operating sequence O - 0.3 Sec – CO - 3 min - CO. Make and Model of Vacuum Interrupter To be provided Aux. DC voltage 30 Volt Aux. AC voltage 230 Volt
87Supply ,fixing testing and commissioning of CT 1 phase outdoor 2 core oil cooled type 33kV .5 Accuracy class andprotection 5P10 burden 15 VA, withstand voltage 70KV,System fault level 25 KA for 3 sec complete all as specified and directed (Niwaru-3)
88Supply ,fixing testing and commissioning of PT IS 3156 part (I-IV) ,IS 4146 ,1 phase outdoor type 33kV .5 Accuracy class andprotection 3P andburden 100 VA, withstand voltage 70KV,Secondary 3KV for 1min complete all as specified and directed (Niwaru-3)
89Supply and fixing Gang operated devices horizontal/vertical of 33KV alongwith the insulators and channels complete with operating handle all as specified and directed (Niwaru-1)
90S&F other Misc items :- Ferrules-0 to 9 (Each letter is hundred in one packet) a to z (Each letter is hundred in one packet)PU Foam 750 ML, Silicon Sealant,Electrical Tape,RED, YELLOW, BLUE, BLACK, GREEN complete all as specified and directed (Niwaru-1, Pioneer -1, Bhakrota-1, Station Furniture-1, Command MT-1)
91Design, Supply, install, testing and commissioning of Solar Observatory system or Weather Station complete all as specified and directed consisting of following:- 1. Pyranometers: 1 2. Rain Guage: 1 3. Module Temp Sensor: 4 4. Ultrasonic Anemometer: 1 5. Temp & relative Humidity Meter: 1 6. Solar Panel (35 W) + Battery Bank: 1 7. Data Logger: 1 Note : All data shall be recorded chronologically date wise. The data file shall be MS Excel compatible. The data logger shall have internal reliable battery backup to record all sorts of data simultaneously round the clock. All data shall be stored in a common work sheet chronologically. Representation of monitored data shall be in graphics mode and/or in tabulation form. All instantaneous data can be shown in the Computer Screen. (Niwaru-1)
92DATA ACQUISITION SYSTEM/PLANT MONITORING& SCADA: Design, supply, installation, testing and commissioning of on grid Data Acquistition/Plant monitoring system (SCADA)suitable for 3 Phase, 415V, 50Hz, AC power string inverter with all protection & controlling as per specifications complete etc as per requirement with an overall efficiency of not less than 98% (with inbuilt or external data logging device & on line portal log-in ID & password) & one PC with intel i5 processor, 2TB HDD, 4GB RAM, 40"" LED monitor, preloaded with Window10 & MS Office, one all-in-one printer suitable for A-4 size papers (black and white). The following parameters (Niwaru-1)
93(i)to (xxiii) should be accessible via operating interface display in real time separately for solar power plant. i. AC Voltage ii. AC Out put current iii.Output power iv.Power factorv. DC Input Voltagevi.DC Input Current vii.Time ActiveviiiTime Disabledix. Time Idlex. Power produced xi.Protective function limits (viz-AC Over Voltage, AC Under voltage, Over frequency)xii.All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing thourgh the internal microprocessor & should be read on the digital frontpanel.xiii.PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current and Energy gererated by the PV system provided. Energy meter along wiht CT/PT should be of 0.5 accuracy class.xiv. Computerized DC String/ Array monitoring and AC output monitoring shall be provided as part of the inverter and/or monitoring shall be provided as part of the inverter and /or string/array combiner box or separately.
94(xix) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xx) Local server data storage capacity shall be sufficient to provide all parameters stored. It should have read and write facility CD/ DVD. (xxi)Remote Monitoring and data acquisition through Remote Monitoring System software at the owners location with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encured by the supplier. Provision for interfacing these data on owners server and portal in future shlall be kept.
95NOTE: The cost of all equipments , internet, ethernet connections, connected cables, computer, printer etc. are included in this item. Training:On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by accepting officer for 03 days. (xxii) Supply, fix/lay and testingofDC Solar cable of size - 1x 4 Sq mm Tinned multistranded Copper Cable with required accessories like conduits, glands, cable tie, ferrules etc. String to SMB of suitable length as per design requirement.
96Design, Supply, install, testing and commissioning of Main distribution board Floor Mounted PDB with 1 x 63A, four pole main incomer with energy meter, indication lamps complete all as specified and directed with and including following outgoings :- (a) 1 x 25A TPN MCB (b) 2 x 63A TPN MCB (c) 4 x 10A TPN MCB (d) 4 x 6A DP MCB (Niwaru-01)
97Design, Supply, install, testing and commissioning of 5 kVA UPS with battery bank for 60 minutesbackup at 100 % loadas per design & specifications for Solar System critical components, Industrial type Onine UPS with static switches for bypass complete all as specified and directed. (Niwaru-1 )
98Design, Supply, install, testing and commissioning of UPS distribution board of Floor Mounted UPS DB, indication lamp as per site conditions. (a) 1x 32 A DP MCB with 100mA ELCB main incomer with energy meter (b) 4 x 10A DP MCB (c) 4 x 6A SPN MCB (Niwaru-1)
99Supply and fixing of fire fighting automation and signboards in buildings, foam type and CO2 fire extinguisher. Supply of LT (1.1kV) Rubber Mat, MV (11kV) Rubber Mat, discharge rods, Sand bucket with stand, 11kV Hand Gloves, First Aid Box and Shock Treatment Chart. (Niwaru-1)
100Registration of solar power project, deposit processing fee with RREC for less than 10 MW including service tax (Niwaru-1) Note 1 :- All items catered in the estimate should fulfill the domestic content requirement for VGF claim and should be compatible to MNRE Guideline. Note 2 :-Entire Design of Solar PV System should comply/approved by SECI/MNRE guidelines.
101Inverters :- 3 phase On Grid String Inverters, 1nos inverters of 100 kw The inverters/ PCUs shall be warranted for 10 years from date of commissioning. Cooling method Smart forced air cooling, Grid Support Reactive power at night function, LVRT, HVRT,active & reactive power control and power ramp rate control, Volt/Watt, Frequency/Watt, DC reverse connection protection, AC short circuit protection, Leakage current protection, Grid monitoring, Ground fault monitoring, Arc fault circuit interrupter (AFCI),PV String current monitoring, Reactive power at night function, Overvoltage protection DC Type II and AC Type IIThe Inverter should comply the IEC 62116. Technical Specification"s are following:- (Pioneer -1, Station Furniture-2)
102(1)Input (DC) -- Recomonded max input npower (Wp) - 15000 Wp , Max. Input voltage - 1100 V , Rated Input Voltage - 625 V, Start-up Voltage - 200 V , MPPT Operating Voltage Range - 180 V - 1000 V, Full Power MPPT Voltage range - 500 V - 850 V, Number of MPP Trackers - 10, Number of DC inputs - 20, Max. Input Current per MPPT - 30A, Max. Input Short Circuit Current per MPPT - 50A, (2) Output (AC) -- Rated Power - 100 KW, Max. AC Power - 110 KVA , Max. Output Current - 160 A , Nominal Grid Voltage - 3/N/PE, 230V/400 vac , Grid Voltage Range - 310 Vac - 480 Vac , Nominal Frequency - 50Hz/60Hz , Grid Frequency range - 45-55 HZ / 54-66 HZ(According to local Standard) , Active power adjustable range - 0-100% , THDI - < 3%, Power Factor - 1 default (adjustable -/+0.8). (3) Performance -- Max Efficiency - 98.70% , European Weighted efficiency - 98.30% , MPPT efficiency - >99.9% . (4) Protection -- DC Reverse polarity protection - Yes , Anti-Islanding Protection - Yes , Leakage Current Protection - Yes , Ground Fault Monitoring- Yes , PV-Array string Fault Monitoring- Yes , DC Switch - Yes , Protection Class/Overvoltage category - I/III , Input/Output SPD - PV: Type II Standard , AC : Type II Standard , Certification - IEC 62116 , IEC 61727 , IEC 61683 , IEC 60068 , (1,2,14,30) , IEC 62109-1/2 , IEC 61000 , IP 65. (5) Communication --Power Management Unit - According to certification and request , communication - RS 485 , Optional WiFi/GPRS. (7)General Data -- Topology - Transformer Less , Ambient Temperature range - -30 - +60 ,Degree of Protection - IP66 ,Allowable Relative Humidity range- 0%-100% ,Max Operating altitude 4000 m , Noice - <60 dB , Weight - 90 Kg , Cooling - Smart Forced air cooling , Display - LDC , Dimension - 995.5 mm * 693.5 mm * 368 mm , Warranty - 10 Years. 100KW inverter.
103Inverters :- 3 phase On Grid String Inverters, 1nos inverters 1no of 30 KW The inverters/ PCUs shall be warranted for 10 years from date of commissioning.Cooling method Smart forced air cooling, Grid Support Reactive power at night function, LVRT, HVRT,active & reactive power control and power ramp rate control, Volt/Watt, Frequency/Watt, DC reverse connection protection, AC short circuit protection, Leakage current protection, Grid monitoring, Ground fault monitoring, Arc fault circuit interrupter (AFCI),PV String current monitoring, Reactive power at night function, Overvoltage protection DC Type II and AC Type II.The Inverter should comply the IEC 62116. Technical Specification"s are following:- (For Pioneer-01)
104(1)Input (DC) -- Recomonded max input npower (Wp) - 15000 Wp , Max. Input voltage - 1100 V , Rated Input Voltage - 625 V, Start-up Voltage - 200 V , MPPT Operating Voltage Range - 180 V - 1000 V, Full Power MPPT Voltage range - 500 V - 850 V, Number of MPP Trackers - 10, Number of DC inputs - 20, Max. Input Current per MPPT - 30A, Max. Input Short Circuit Current per MPPT - 50A, (2) Output (AC) -- Rated Power - 100 KW, Max. AC Power - 110 KVA , Max. Output Current - 160 A , Nominal Grid Voltage - 3/N/PE, 230V/400 vac , Grid Voltage Range - 310 Vac - 480 Vac , Nominal Frequency - 50Hz/60Hz , Grid Frequency range - 45-55 HZ / 54-66 HZ(According to local Standard) , Active power adjustable range - 0-100% , THDI - < 3%, Power Factor - 1 default (adjustable -/+0.8). (3) Performance -- Max Efficiency - 98.70% , European Weighted efficiency - 98.30% , MPPT efficiency - >99.9% . (4) Protection -- DC Reverse polarity protection - Yes , Anti-Islanding Protection - Yes , Leakage Current Protection - Yes , Ground Fault Monitoring- Yes , PV-Array string Fault Monitoring- Yes , DC Switch - Yes , Protection Class/Overvoltage category - I/III , Input/Output SPD - PV: Type II Standard , AC : Type II Standard , Certification - IEC 62116 , IEC 61727 , IEC 61683 , IEC 60068 , (1,2,14,30) , IEC 62109-1/2 , IEC 61000 , IP 65. (5) Communication --Power Management Unit - According to certification and request , communication - RS 485 , Optional WiFi/GPRS. (7)General Data -- Topology - Transformer Less , Ambient Temperature range - -30 - +60 ,Degree of Protection - IP66 ,Allowable Relative Humidity range- 0%-100% ,Max Operating altitude 4000 m , Noice - <60 dB , Weight - 90 Kg , Cooling - Smart Forced air cooling , Display - LDC , Dimension - 995.5 mm * 693.5 mm * 368 mm , Warranty - 10 Years.
105Inverters :- 3 phase On Grid String Inverters, 1nos inverters of 50 kw.The inverters/ PCUs shall be warranted for 10 years from date of commissioning.Cooling method Smart forced air cooling, Grid Support Reactive power at night function, LVRT, HVRT,active & reactive power control and power ramp rate control, Volt/Watt, Frequency/Watt, DC reverse connection protection, AC short circuit protection, Leakage current protection, Grid monitoring, Ground fault monitoring, Arc fault circuit interrupter (AFCI),PV String current monitoring, Reactive power at night function, Overvoltage protection DC Type II and AC Type II.The Inverter should comply the IEC 62116. Technical Specification"s are following:- (For Bhakrota-04, Command MT-06)
106(1)Input (DC) -- Max input power (Wp) - 66500 Wp , Max DC power for single of MPPT - 22000W/16000W/16000W , Number of independent MPPT - 3 , number of DC input - 4/3/3 ,Max. Input voltage - 1000 V , Rated Input Voltage - 600 V, Start-up input Voltage - 350 V , MPPT Voltage Range - 250 V - 950 V, Full Power MPPT Voltage range - 530 V - 830 V,Max. Input MPPT Current - 40A/30A/30A ,Max. InputCurrent per String - 12 A , Max DC input Isc per MPPT - 48A/36A/36A. (2) Output (AC) -- Rated Power(@230 V, 50Hz) - 50 KW, Max. AC Power - 50 KVA , Max. Output Current - 80 A , Nominal Grid Voltage - 3/N/PE, 220/380 Vac, 230/400 vac , 240/415 Vac , Grid Voltage Range - 310 Vac - 480 Vac(according to local standard) , Nominal Frequency - 50Hz/60Hz , Grid Frequency range - 45-55 HZ(According to local Standard) , Active power adjustable range - 0-100% , THDI - < 3%, Power Factor - (adjustable -/+0.8). (3) Performance -- Max Efficiency - 98.50% , European Weighted efficiency - 98.30% , MPPT efficiency - >99.9% , Self Consumption at night - <1 W. (4) Protection -- DC Reverse polarity protection - Yes ,DC Switch - Yes , Protection Class/Overvoltage category - I/III , Input/Output SPD(II) - PV: Type II Standard , AC : Type II Optional , Safety protection - Anti islanding, RCMU, Groundfault monitering , Certification - IEC 62116 , IEC 61727 , IEC 61683 , IEC 60068 , (1,2,14,30) , IEC 62109-1/2 , IEC 61000 , IP 65 , ARPC Anti Reverse power controller (optional). . (5) Communication --Power Management Unit - According to certification and request , Standard communication Mode - RS 485 , Optional WiFi/GPRS , SD Card , Multi-function relay. (7) General Data -- Ambient Temperature range - -25 - +60 , Topology - Transformer Less , Degree of Protection - IP65 ,Allowable Relative Humidity range- 0%-100% ,Max Operating altitude 4000 m , Noice - <60 dB , Weight - 68 Kg , Cooling - Fan, Display - LDC Display , Dimension - 713 mm * 737 mm * 297 mm , Warranty - 10 Years , BIS Certified -IS 16221 (part 2):2015/IEC 62109-2 : 2011&IS 16169 : 2014 IEC 62116 :2008 . 50KW inverter.
107Remote Monotoring device ( web designing or software for cloud data for monitoring ofgeneration of Solar Plant ) complete all as directed. (Pioneer -1, Bhakrota-1, Station Furniture-1, Command MT-1)
108Supply, install, testing of Solar meter formonitoring of monthly production of the plant along with CT and PT and related accessories complete allas specified and directed (Pioneer -1, Bhakrota-1, Station Furniture-1, Command MT-1)