Tender For Maint, Repair, Replacement Of Def Items Of Lt Distribution System, Dbs, Mcbs, Cables And Allied Services And Repair Of Defective Items Of Street Lights / Security Lights, Dg Sets, Amf Panel And Misc Items Under Ge (Af) Lohegaon At 9 Brd Af, pune-Maharashtra

Military Engineer Services-MES has published Tender For Maint, Repair, Replacement Of Def Items Of Lt Distribution System, Dbs, Mcbs, Cables And Allied Services And Repair Of Defective Items Of Street Lights / Security Lights, Dg Sets, Amf Panel And Misc Items Under Ge (Af) Lohegaon At 9 Brd Af. Submission Date for this Tender is 09-03-2024. Diesel Generators Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42017922
Corrigendum : Tender For Maint, Repair, Replacement Of Def Items Of Lt Distribution System, Dbs, Mcbs, Cables And Allied Services And Repair Of Defective Items Of Street Lights / Security Lights, Dg Sets, Amf Panel And Misc Items Under Ge (Af) Lohegaon At 9 Brd Af
Open Tender
Indian
Maharashtra
pune
09-03-2024

Tender Details

Maint, Repair, Replacement Of Def Items Of Lt Distribution System, Dbs, Mcbs, Cables And Allied Services And Repair Of Defective Items Of Street Lights / Security Lights, Dg Sets, Amf Panel And Misc Items Under Ge ( Af ) Lohegaon At 9 Brd Af Stn Pune

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Feb-2024 REV CRIC DATES Date 27-02-2024
2 22-Feb-2024 REVISED TENDER PAGE Other 02-03-2024
3 22-Feb-2024 REVISION OF BOQ BOQ 02-03-2024
4 22-Feb-2024 CRIC DATE REVISION Date 02-03-2024
5 02-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

BOQ Items

Name of Work:MAINTENANCE, REPAIR AND REPLACEMENT OF DEFECTIVE ITEMS OF LT DISTRIBUTION SYSTEM, DISTRIBUTION BOARDS, MCBS, CABLES AND ALLIED SERVICES AND REPAIR AND REPLACEMENT OF DEFECTIVE ITEMS OF STREET LIGHTS / SECURITY LIGHTS, DG SETS, AMF PANEL AND MISC ITEMS AT 9 BRD AF STN PUNE UNDER GE (AF) LOHEGAON
Sl. No. Item Description
1Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed.
2Dismantling / taking out insulator of any size / type from existing electric LT lines complete.
3Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete
4Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as directed.
5Disconnecting of incoming / outgoing cables and earthing lead and taking out existing unserviceable outdoor feeder pillar box / Paneland removing unserviceable pillar box / Panel with frame from the PCC foundation complete all as directed.
6Taking down Old unserviceableLT UG cable of service connection or distribution systemof any size and removing from site all as directed.( Excavation and earth work will be measured seperately)
7M&L for scrapping of old alum paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces andpainting with two coats of alum paint on pole , brackets old junction boxes channels etc inclalternate 30 cm wide white andblue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed by Engr -in-Charge.
8Material & Labour forpainting to feeder pillar box / LT panel & duct coveretc, including angle iron frame with two coat of grey synthetic enamel paint includingwelding of door with proper size new hinges of suitable size and locking arrangementswhere required complete as specified.
9Cutting/trimming of treesupto 150 mmgirth including cutting of upper portion of branches above poleclearance up to 10 mtrs and disposal ofsame at a distance not exc 50 mtr and clearing of site complete as directed.(Note:Tools/ladder required for cutting/trimming of trees will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.) Note:Each Span will be measured from one pole to another pole
10Provn ofservices for cable fault locationfor LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
11Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below all as specified and directed.
1225 to 50 sqmm 3.5 core
1370 to 150 sqmm 3.5 core
14185-240 sqmm 3.5 core
15300-400 sqmm 3.5 core
16Supply and fix GI Pipe Light gradewith all connected accessoriesof sizes100 mm completed as directed
17Supply and fix GI Pipe Light gradewith all connected accessoriesof sizes80 mm completed as directed
18Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of pole all as specified and directed at site.
19Material and labour for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections, including nut bolts, washer welding bending cold/ hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one premer coat of red oxide primer, one under coat and one finishing coat of aluminium paint all as directed and as specified.
20S&F shackle type insulator vitreous procelain white / brown / greenwith and including galvanised mild steel straps, washer insulator, bolts and nuts, insulator of size 100mm height and 115 mm max dia with working pressure 1100 volt and galvanised steel straps 3 to 5 mm size and suitable size nut and bolts all as directed and as specified.
21M&L for providing pin type procelain white / brown / green / insulator including galvanised mild steel spindle, two galvanised iron.Washer and one galvanised iron nut, 100mm height 65 mm dia for 1100 volts grade all as directed.
22M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm all as directed
23M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation or as required on siteetc complete all as directed by Eng-in-Charge
24M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as required on siteetc complete all as directed by Eng-in-Charge
25M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etcor as required on siteetc complete all as directed by Eng-in-Charge
26Supplying, spreading & leveling stone aggregate size of 40 mm grade to the existing sub station or all as specified and directed by Engineer-in-Charge.
27Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specifiedfor following size:-
2810 sqmm 2 core
2916 sqmm 4 core
3025 sqmm 3.5 core
3135 sqmm 3.5 core
3250 sqmm 3.5 core
3370 sqmm 3.5 core
3495 sqmm 3.5 core
35120 sqmm 3.5 core
36150 sqmm 3.5 core
37185 sqmm 3.5 core
38240 sqmm 3.5 core
39300 sqmm 3.5 core
40Relaying ofold serviceable LT/HT under groundPVC/XLPE cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and as directed by Engineer-in-charge. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
41Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc.
42Soft/loose soil
43Hard/dense soil
44Soft/disintegrated rock
45Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil.
46Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level.
47Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measurement will be done after punning]
48M&L for brick protection covers laid over cables of sub class"B" bricks old size all as specified and directed.
49Supply and fix in repair / replacement of MCCB FP 630 Amps Adjustable type with breaking capacity50 KAincluding connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
50Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity36 KAincluding connections and testing for proper functioning incl taking out unserviceablecomplete all as specified and directed.
51Supply and fix in repair / replacement of MCCB FP 250 AmpsAdjustable type with breaking capacity36 KAincluding connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
52Supply and fix in repair / replacement of MCCB FP 200 AmpsAdjustable type with breaking capacity36 KAincluding connections and testing for proper functioning incl taking out unserviceablecomplete all as specified and directed.
53Supply and fix in repair / replacement of MCCB FP 160 AmpsAdjustable type with breaking capacity36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
54Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity36 KAincluding connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
55Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity36 KAincluding connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
56Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KAincluding connections and testing for proper functioning incl taking out unserviceablecomplete all as specified and directed.
57Supply and fix in repair / replacement of MCCB TP 63 AmpsFixed type with breaking capacity16 KAincluding connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
58Supply install, test and commissioning of Powder coated LTpanel cubical out door type Channel mounted compartmentalized in construction allConfirming to IS 8623 Part 1 1993CPRI approved factory fabricatedmade out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars of 400 A. incomer MCCB and outgoing feeder.The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhaveabottomchannel. A detachable predrilled gland plateof thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side.The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wireand consisting the following, includingdisconnecting Existing cables & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts
59a) Copper bus bar 400 Amps for 3 phase andNeutral b) MCCB FP 250 Amps415 Volt 25 KA - 1 Nos c) MCCB FP 100 Amps - 415 Volt 16 KA- 2 Nos d) MCCB FP 63 Amps 415 Volt16 KA - 4 Nos e) 3 Phase digital voltmeter-1 f) 3 Phase digital Ammeter-1 g) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved from the Accepting officer by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer from list of manufacturer given in particular specification
60All as per item no 58 but with the following acessoriesa) Copper bus bar 500 Amps for 3 phase andNeutral b) MCCB FP 315 Amps415 Volt 36 KA - 1 Nos c) MCCB FP 100 Amps - 415 Volt 16 KA- 6 Nos d) MCCB FP 63 Amps 415 Volt16 KA - 2 Nos d) MCCB FP 125 Amps - 415 Volt 18 KA- 1 Nos e) 3 Phase digital voltmeter-1 f) 3 Phase digital Ammeter-1 g) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved from the Accepting officer by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer from list of manufacturer given in particular specification
61All as per item no 58 but with the following acessoriesa) Copper bus bar 400 Amps for 3 phase andNeutral b) MCCB FP 160 Amps415 Volt 36 KA - 1 Nos e) 3 Phase digital voltmeter-1 f) 3 Phase digital Ammeter-1 g) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved from the Accepting officer by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer from list of manufacturer given in particular specification
62S & F VTPNDB 4 Waysheet metal enclosure double door suitable for MCCB incommer andMCBs outgoing including MCCB 4P 125 Amps 10 KAcomplete all as speccified and directed including making good disturbed surfaces complete.
63Supply and fixing SP 5 To 32 Amps rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing andcommissioning.
64All as above as per item no 62 butSPN 32 Amps
65All as above as per item no 62 butTP 25 to 63Amps 415 Volts
66S & F Sub Main Wiringwith PVC Insulatedmultistranded copper conductorwires ofsize2x6.0 sq. mm + 1x6.0 sq. mm earth wireincluding PVC cassing and capping complete all as specified and directed
67Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm),funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
68S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as directed.
69Opening/disconnecting the electrical connection of defective/burnt out underground LT Cable of any size 2 to 4 core from main switch/DB/ junction box / LT panel /LT OH line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable, providing required thimbles/ connectors at cable end and reconnecting the cable in previous location with existing main switch/ DB/Junction box /LT Panel/ OH line etc complete all as directed.
70Material and labour for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out removing of grass and vegetation grown around the electrical installations like transformers, LT panels, 2 pole structure, HT panels and complete area inside the fencing all as specified and directed by Engr-in-Charge Note : Item may be measured and paid more than one time as per site requirement to clean the E/M Installations
71Supply and fix all in one solar street light fitting 20 watt having high lumen efficiency, includinginbuilt solar panel and long life maintenance free lithium ferro phosphate battery micro controller based integrated MPPT charge controler with driver complete all as specified and directed by engr-in-charge.
72M&L for Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm),funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
73M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified. Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
74Supply and fix in repair / replacement of MCCB FP 1250 Amps Thermal magnetic Adjustable type microprocessor release with breaking capacity65 KAincluding connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
75S& F in replacement 3 Phase Digital voltmeter 0-1100V Range including selector push btton suitable for fixing in existing panel including control wiring complete.
76S& F in replacement 3PhaseDigital Ammeter 0-800AmpRange including selector push btton suitable for fixing in existing panel including control wiring complete.
77Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 6 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and as directed by Engineer-in-charge.
78M/L for sub main wiring with two runs of single core 2.5 Sq mmFRLS PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 2.5 Sq mmsingle core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 2.5 Sqmm copper cable & one run of 2.5 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
79S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length).
80M&L for Servicing of APFC panel of rating upto 200KVA including checking of CTs, control wiring, cleaning of panel and capacitor banks, tightning incoming and outgoing connections, supply and replacement of contactor, checking of capacitor banks, contact relayetc and making APFC panel serviceable complete upto satisfaction of Engr-In-Charge. (Note : Any minor/major spare partfound faulty during checking such as contactor, CTs,contact relay and cable lugs , minor wire pieces including cost of T&P, multimeter etc shall be included in quoted rates of this item)
81M & L for servicing of high mast light driving mechanism by checking alll electrical and machnical component, chain, pully, rope,. Motor etc and greasing oiling of chain, motor, pully etc servicing of motor, control panel, auxiliary contacts, replacement of u/s items i.e. toggle switch, indicator light, control wiring complete all as specified and directed.
82Labour& Tools incl ladders toattanding general street light complaints for repair / maint of steert light/ flood light fitting any type and capacityafter taking out from poles upto 11 mtrs height any place wihin the stn checking throughly function of drivers and connected item, removing carbon on joints, repairing of cable joints/ loose connection, making sholdering etc incl replacement of small parts like wire upto 1.5 mtr long, nut bolts, screws , insulation tape etc fixing on pole after carry out nacessary repairs and testing for smooth functioning complete all as specified and directed. Note :(a) Repairs may be carryed out as an when required basis on sitei.e number of times andshall be measured and paid as per site requirement as per satisfaction of Engr-in-Charge andSpare parts like electronic drivers, ballast , lamp , ignator etc shall be measured and paid separately in respective items.
83Lowering down of high mast light at any height repairing and replacement of unserviceable parts such as ignitor, capacitor, ballast, lamp electronic driver and internal and external circuit etcas required on site complete all as specified and directed. (Note : Spare / parts required for replacement shall be measured and paid seperately and lowering down work may be carry out as and when required basis for any kind of repair.)
84Taking down the existing street light fitting and Supply & fix (inRepalcement)energy saving and environmental frindly long life LEDStreet light fitting35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete withimpact and corrosion resistant including thermalmanagement in multiple opticsIP 65/IP66 road way luminarieswith LEDs as light source and lensembedded PC cover /toughened glassand impact resistance of IK07 and electronic driverfixed on pole with and includingsuitabledia sizebracket as per manufacturer recommendation, bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.
85-ditto- all as per item Ser No 83.00 above but 60 Watt complete all as specified and directed
86-ditto- all as per item Ser No 83.00 above but 70 Watt complete all as specified and directed
87-ditto- all as per item Ser No 83.00 above but 90 Watt complete all as specified and directed
88Taking down the existingFlood lights fitting and Supply & fix (inRepalcement)energy saving and environmental frindly long life exclusive innovative flood light luminaries 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with LEDs as light source and lensembedded PC cover /toughened glassand impact resistance of IK07 and electronic driverfixed on high mast poleor any any other place as requird on site incl making all nacessary arrangement for fixing complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers complete all as specified and directed.
89-ditto- all as per item Ser No 87.00 above but 120 Watt complete all as specified and directed
90-ditto- all as per item Ser No 87.00 above but 170/180 Watt complete all as specified and directed
91-ditto- all as per item Ser No 87.00 above but 200/210 Watt complete all as specified and directed
92Taking down old,rusted, unsv Junction boxof any size, type and supply & fix new junction box of size not less than 400 mm x300 mm x 190 mm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof, restricted to unauthorised tapping with class FV-0 as per IS : 11731 Part-II or V-0 as per UL-94and fixing to pole etc using suitable clamps nuts, bolts etc for accommodating and including the following complete all as specified and directed:- a)Four strip Aluminium Bus barof capacity 100 A , 20 CM long- 01 Set b) MCB SP 10A-01 Nos
93S&F in replacement of PVC insulated 1.5 sqmm copperthree core conductor cable between cable loops box to fitting drawn through the pole complete all as specified and directed
94S&F along pole PVC non metallic conduit of dia 20 mm medium grade including MS clamps and nut bolts etc for fixing along the pole complete all as specified and directed
95Supply and fix GI Pipe Light gradewith all connected accessoriesof sizes40 mm complete all as specified and directed
96Supply and fix GI Pipe Light gradewith all connected accessoriesof sizes50 mm complete all as specified and directed
97Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin coremultistranded cable flat or circulas 4 sqmm incl taking out old unserviceable wire complete all as specified and directed.
98Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin coremultistranded cable flat or circulas 10 sqmm incl taking out old unserviceable wire complete all as specified and directed.
99Trimming for branches of trees, bushes, hurbs under over head line including removal of trees branches INCL CREEPERS etc to a distance not exceeding 5 mtr from over head line complete all as specified and directed.(Note: one span shall be considered as pole to pole distance between two poles)
100Supplyand fixing LED Post top fitting40 Watt5700 K CCT IP 65powder coated aluminium die cast and spun aluminium with cleardiffuser suitable for landscape lighting incl making necessary arrangement for mounting fittingas reqd on site and testing complete all as specified and directed.
101Taking old unserviceable driver from LED light fitting and S&F LED outdoor driver with all Electricals connection as per existing make on site and testing for smooth functioning complete all as specified and directed. For followingcapacity oflight fitting
102(a) for LED light fitting 60-72 Watts
103(b) for LED light fitting 80-120 Watts
104(c) for LED light fitting 150 Watt
105(d) for LED light fitting 250 Watt
106(e )for LED light fitting 300 Watt
107Supplyand fixing LED Bollard light fitting8W IP 65powder coated PDCaluminium body with opaldiffuser weather proof900 mm long suitable for landscape lighting incl making necessary arrangement for mounting fittingincl PCCwork as reqd on site andtesting complete all as specified and directed.
108Taking down the existinghighbay light fitting and Supply & fix (inRepalcement)energy saving and environmental friendly robost IP 65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended)mount 120 Watt with system efficiencynot less than 120 lm/W incl electronicdriverfixed inceiling/ suspended incl making all nacessary arrangementfor fixing/hanging and ancheringas required on sitemaking electrical connections complete all as specified and directed.
109Taking out carefully serviceableLT UG Cable/wiresafter disconnecting from DBs on wall/duct/cutting of walls ofassorted size as required on siteand re routing properly by making proper cutting in wall/cable duct clamping etc completed and making good disturbed surface of wall/floor as existing sourrounding complete all as specified and directed.
110Supply and fix MCB SPN 40 Amp, 230 volt "C" series complete all as specified and directed.
111S&F in replacement of old unserviceable contactor ML-3,40 Amps power operating voltage 415 V AC Capacity. complete all as specified and directed
112Taking out the old unserviceable all In one solar street light including solar panel from pole after disconnecting connection wires carefully, checking the connections, replacement of driver if unsv, cleaning of solar panel, checking of battery connectinsetc, making light serviceable and refixing at original position complete all as directed .
113Cleanig of solar street light PV panel mounted on pole of any height for better efficiency of solar light ON MONTHLY BASIScomplete all as directed.
114Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to and including galvanised iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate no. 3 of SSR part I, and testing on completion including excavation and earth work in any type of soil, PCC 1:3:6 type C1 earthing chamber, precast slab 50 mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire fabric (XPM) weight not less than 4kg/sqm, funnel with wire mesh, watering pipe of 20 mm bore medium grade GI pipe and lugs, earthing wire protected by galvanised iron or steel pipe 15 mm dia medium grade 7.5 metre long complete all as specified and as directed.
115M&L for servicing of DG set 62.5 KVA to 125 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
116M&L for servicing of DG set 160 KVA to 250 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etcgreasing oiling and checking for smooth functioning of DG Set complete all as specified and directed.( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
117M&L for servicing of DG set 500 KVA to 750 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above)
118Material only for the following item of DG set62.5 KVA to 125 KVA DG set be incorporated in repairs for item No 112.00 complete all as specified and directed.
119(a) Fuel Filter
120(b)Oil Filter element with "O" ring
121(c) Fan belt
122(d) Alternator belt
123(e) Radiator hose pipe inlet/outlet
124(f) Solenoid switch 12 volts,DC
125(g) Oil Pressure Pipe
126(h) Fuel Pressure Pipe
127Material only for the following item of DG set 160 KVAto 250 KVA to be incorporated in repairs for item No 113.00 complete all as specified and directed.
128(a) Fuel Filter
129(b) Oil Filter element with "O" ring
130(c) Fan belt
131(d) Alternator belt
132(e) Radiator hose pipe inlet/outlet
133(f) Solenoid switch 12/24 volts,DC
134(g) Oil Pressure Pipe
135(h) Fuel Pressure Pipe
136Material only for the following item of DG set 500 KVA to 750 KVA to be incorporated in repairs for item No 114.00 complete all as specified and directed.
137(a) Fuel Filter
138(b)Oil Filter element with "O" ring
139(c) Fan belt
140(d) Alternator belt
141(e) Radiator hose pipe inlet/outlet
142(g) Oil Pressure Pipe
143(h) Fuel Pressure Pipe
144M &L for Removing the fuel injection pump (FIP) & injectors from DG set cap 62.5 KVA to 160 KVA and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning complete all as specified and directed. Note :-Repairs will be carried out from authorised workshop.
145Taking down defective self starter 12 Volt of DG set of cap from 20KVAand below160 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
146(a) Rewinding the burnt field coil.
147(b) Rewinding the burnt armature coil with commutator.
148(c) Replacement of bush/ bearing.
149(d) Replace the worm out carbon brush with brush holder.
150(e) Replacement of clutch.
151(f) Replacement of solenoid switch.
152(g) Replacement of Bentex drive.
153Taking down defective self starter 24 Volt of DG set of cap from 160 KVA to 750 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
154(a) Rewinding the burnt field coil.
155(b) Rewinding the burnt armature coil with commutator.
156(c) Replacement of bush/ bearing.
157(d) Replace the worm out carbon brush with brush holder.
158(e) Replacement of clutch.
159(f) Replacement of solenoid switch.
160(g) Replacement of Bentex drive.
161M&L for disconnecting the U/S alternator capacity of 30 KVA to 160 KVA, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning complete all as specified and directed.
162Taking down old US contactor and S&F new contactor for the following range complete all as specified and directed.
163(i) Power Contactor40A, 415 volt, 4 pole, 2 NO+
164(ii) Power Contactor80A, 415 volt, 4 pole, 2 NO+
165(iii) Power Contactor225A, 415 volt, 4 pole, 2 NO+2NC
166Material and labour for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as specified and directed.
167Material and labour for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as specified and directed.
168M & L for replacement ofbrass battery terminal suitablefor lead Acid Battery 12 V 40 AH to 12 V , 180 AH complete all as specified and directed.
169M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter complete and testing complete all as specified and directed. Note :- Spare parts required will be measured and paid separatelyunder relevant item of this Schedule here after.
170(a)Toggle switch suitable for AMF panel.
171(b)CT"s of range 62.5 to 400 KVA
172(c)Relay of range 62.5 KVA to 400 KVA.
173(d)Ammeter digital type square flush type
174(e)Voltmeter digital type square flush type
175(f) Copper wire single core for internal connection.
176(g) Voltage monitoring relay (digital type)
177(h) DG set AMF digital Controller
178M&L for taking out diesel from the fuel tank of DG set of capacity 20 KVA to 160 KVA and cleaning the fuel tank complete of any size complete all as specified and directed..
179M&L for De-scaling & cleaning , painting (except fins area) & welding / soldering / brazing of radiator of any capacity & any type ccomplete all as specified and directed.
180Supply only coolant for radiators of DG sets of capacity 30 KVA to 750 KVA complete all as specified and directed.
181Supply only battery distilled water for batteries of DG sets complete all as specified and directed.
182M&L for draining out old engine oil and filling new engine oil of grade as recommended by manufacturer for DG set any make and capacity complete all as specified and directed.
183S & F in replacement of fuel indication transparent plastic tube of any size as per existing complete all as specified and directed.
184Supply and fix in replacement of broken acoustic enclosure door hinges with stainless steel hinges complete with nut bolts etc as per site requirement of any type, cap and make of DG set complete all as specified and directed.
185Materials andlabour for scraping removing and cleaning old rusty paint from enclosure of DG set 62.5 KVA to 160KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint complete all as specified and directed.
186S&F Silencer with exhaust pipe complete bends, coupling etc suitable for 100 to 400 KVA DG set including fixing arrangements and painting with silver colour over a coat of red oxide primer complete all as specified and directed.
187Supply & Fix in replacement of automatic voltage regulator 62.5 to 400 KVA DG set complete all as specified and directed.
188Supply and fixing ofPVC Insulated, PVC Round Sheathed Multi Core Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volt 1.5 sqmm and 7 core from DG set to AMF Panelcomplete all as specified and directed.
189Supply and fixing of 180 AH sealed lead acid battery 12 volt into DG set with all necessary connections complete all as specified and directed.
190Labour only for comprehensive maintenance ofand attending day to day break down of DG Set including servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner including replacements of defective/ worn out spares such as diesel filters, oil filters, rubber hose pipe ,V-belt, fuel pipe and change of oils etc. and cleaning of Radiator with new at site complete all as specified and directed. Note:- (i) The maintenance cost of DG Set shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts and labour cost for fixing spares. (ii)All spares and oil replaced will be measured and paid under relevant items of schedule ‘A’. (iii) Servicing shall be carried out authorised dealer of manufacturer i.e. OEM. (iv)Non attending the complaint with in 8 Hrs @ Rs. 2000.00/day shall be recovered by the contractor. (v)Keep the complaint pending after one day @ Rs.4000.00/day shall be recovered by the contractor. (vi) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-Incharge. (g) Spares shall be measured and paid separately. (h) Comprehensive maintenance of DG sets is applicable for contract period per job and shall be measured and paid once as one job on completion of contract only
191(a) 62.5 KVA to 125 KVA
192(b) 160 KVA to 250 KVA
193(c) 500 KVA to 750 KVA
Disclaimer :