Tender For Repairing Replacement And Servicing Of Split And Window Ac Units And Accessories Of The Offices Under Esd Atul Grove Road And Residence Of Sr. Officers Of Bsnl Under The Jurisdiction Of Bsnl Electrical Division I, New Delhi. Ch. To Rm Of A, delhi-Delhi

Bharat Sanchar Nigam Limited-BSNL has published Tender For Repairing Replacement And Servicing Of Split And Window Ac Units And Accessories Of The Offices Under Esd Atul Grove Road And Residence Of Sr. Officers Of Bsnl Under The Jurisdiction Of Bsnl Electrical Division I, New Delhi. Ch. To Rm Of A. Submission Date for this Tender is 14-02-2024. Air Conditioner Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42012851
Tender For Repairing Replacement And Servicing Of Split And Window Ac Units And Accessories Of The Offices Under Esd Atul Grove Road And Residence Of Sr. Officers Of Bsnl Under The Jurisdiction Of Bsnl Electrical Division I, New Delhi. Ch. To Rm Of A
Open Tender
Indian
Delhi
delhi
14-02-2024

Tender Details

Repairing Replacement And Servicing Of Split And Window Ac Units And Accessories Of The Offices Under Esd Atul Grove Road And Residence Of Sr. Officers Of Bsnl Under The Jurisdiction Of Bsnl Electrical Division I, New Delhi. Ch. To Rm Of Ac Units

Key Value

Document Fees
INR 590 /-
EMD
INR 11390.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:"Repairing/ Replacementand servicing of Split & Window AC Units and accessories of theofficesunder ESD-Atul Grove Road and Residence of Sr. officials of BSNLunder the jurisdiction of BSNL Electrical Division-II, New Delhi."
Sl. No. Item Description
1Dismantling 1.5TR/2TR window AC unit along with accessories and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required.
2Dismantling 1.5TR/2TR Split AC unit along with refrigerant pipe lines, power cable and other accessories and keeping all the dismantled items at desired location as per the directions of engineer in charge etc. as required.
3ITC of 1.5/ 2.0 TR Split AC units at desired location, i/c fixing of refrigerant piping with insulation, drain pipe, flexible covering, power connections, testing, commissioning etc. complete as reqd.
41.5/2.0 TR Split A.C. Units
5Installation of 1.5/2TR window type A.C. in the existing window i/c modification and fixing suitable wooden frame, loading unloading etc. complete as reqd.
6Servicing offollowing capacity Window / SplitAC / water cooler Units including washing & cleaning of filters, complete unit i.e evaporator unit, condenser unit i/c oiling, greasingof motors, testing, commissioning etc. complete as reqd.
71.5/2.0 TR Window/ Split A.C. Units & water cooler
8Repairing & Testing of 1.5/2.0 TR Capacity Split AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal ofleakage inIndoor unit & out door unit including supply & charging of refrigerant gas (R-22) and oiling, greasingof motors, testing commissioning etc. complete as reqd.
9Supply and topping up of refrigerant gas (R-22) in existing 1.5/2.0 TR capacity Split AC units, i/c tracing the leakage if any and rectifying the same, refinishing of refrigerant pipes, joints, testing & commissioning of A C unit etc. complete as reqd.
10Replacement of following faulty motor with new copper wounded motor suitable for operation on single phase 230 V, A C supply in the existing Split/Window AC unit i/c removal of faulty motor, making electrical connections, testing, commissioning etc. complete as reqd. (M/s Crompton, Ashu or as per manufacturer recommendation)NOTE:- The motor shall be guaranteed for One Year
111/8 HP Condenser Fan Motor
121/4 HP Condenser Fan Motor/water cooler condensing fan motor
131/35 HP Indoor Unit Fan Motor
141/8 HP Double Shaft Fan/Blower Motor
15Replacement of following defective/ unserviceable compressor in the existing Window / Split AC units with following new compressor suitable for operation on single phase, 50 Hz A C Supply i/c removal and re-installation of defective compressor, refrigerant piping & nut bolts of foundation, electrical connection and making connection with existing refrigerant pipe lines, brazing, electrical wire/ cable terminations, making joints (wherever required), testing, commissioning etc. complete as reqd. (NOTE:- Original Invoice and Test Certificate of the compressor shall be submitted.)
161.5 TR Capacity Rotary Sealed Compressor (M/s Hitachi/ LG/ Voltas)
172.0 TR Capacity Rotary Sealed Compressor (M/s Hitachi/ LG/ Voltas)
181.5 TR Capacity Reciprocating Hermetically Sealed Compressor (M/s Hitachi/ Daikin / LG/ Voltas/Emerson)
192.0 TR Capacity Reciprocating Hermitically Sealed Compressor (M/s Hitachi/ Voltas / LG/Emerson)
20S/Fixing, pre-fabricated M S Frame made out of 35x35x5 mm thk M S angle stand for 1.5/ 2.0 TR Split AC condenser i/c 2 coats of paint, grouting/ fixing on floor etc. as required.
21Replacement of existing faulty/unserviceable 1.5 TR Indoor Units of Split AC Units by supplying new 1.5 TR Indoor Unit, suitable for operation on 230 V AC supply, complete with blower, cooling coil, filters, controls & all accessories and remote control,etc. complete as reqd. (Make : M/S Hitachi/ Blue Star/Carrier/Voltas make)
22Replacement of condenser coil of existing outdoor units of 1.5/2.0 TR split AC unit with new copper coil i/c removing the old coil nut bolt installing the new coil brazing testing commissioning etc. complete as reqd.
23Replacement of cooling coil 1.5/2.0 TR split AC unit i/c removing the old coil nut bolt fixing the new coil refrigerant piping brazing connection testing commissioning etc. as reqd.
24Providing and fixing of 3mm thick ply wood in the existing window i/c cutting & fixing with the help of screws etc. complete as required.
25Replacement /Fixing of following items in existing 1.5/2.0 TR capacity Split AC unit suitable for operation on Single phase, 240 Volt, AC Supply, testing, commissioning etc. complete as reqd.
26Running capacitor 45 mfd/ 50+5 mfd
27Starting Capacitor (120/150 mfd)
28Copper wiring kit
29Condenser Fan Blade (Transparent PVC/ Metallic)
30Thermostat (Danfoss or Renutrol)
31PCB repairing for remote control of A C unit
32SITC of new PCB for remote control of AC unit
33Supply/ Fixing of Remote Hand Set with enclosure
34Hitachi
35LG
36Gujral
37Supply/ Fixing of 3 Pin 20 Amp, 240 Volt AC Industrial Top
38S/Fixing 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i/c connections etc. complete as reqd.
39S/Fixing PVC flexible pipe to cover the refrigerant pipes and power cables in the existing wall/on surface/ M S Tray with saddles, screwsincluding S/F clamps etc. as required.
4050 mm Dia
41S/Fixing of following size 1.1 KV Grade PVC insulated copper conductor flexible cable in the existing M.S. Tray/Surface/Wall including S/F saddles, screws, thimbles i/c making connections, testing etc. complete as required.
423 Core 2.5 Sqmm
43Pdg. & installing following size 22 Gauge of copper refrigerant pipe along with insulation including cutting bending, jointing, brazing , testing and commissioning etc as required.
441/4 inch size nominal dia
451/2 inch size nominal dia
465/8 inch size nominal dia
47Supplying and fixing of wall mounted relay operated line Voltage Stabilizer suitable to work for incoming main from 150 to 270 Volts, Output Voltage between 195 to 245 Volts of 4 KVA with High and Low Voltage cut-off and Time Delay Relay etc. complete as required. (M/S Bluebird/ Logicstat/Microtek make).
48Repairing of existing faulty 4KVA/5KVA Voltage Stabilizer installed for window/split AC Units i/c replacement of faulty/burnt components such as PCB, Transformer, Voltmeter, TDR Switch etc., connections, testing etc. complete as reqd.
49Note: The dismanled material shall be the property of Contractor. Rates must be Quoted accordingly. SCOPE OF WORK: 1. No material shall be supplied by the department. 2. Nothing extra shall be paid on account of cartage. Suitable arrangement should be made by the firm to attend the complaint within 2 Hours after receiving the complaint. For this purpose the contractor shall have to provide minimum 1 No. Skilled and 1 No. Un-skilled worker between 09:00 AM to 06:30 PM at ESD-Atul Grove Road (If more man power is required at any stage, same shall be provided by the Agency without any extra cost) from Monday to Saturday. Necessary arrangement should be made by the firm for attending the complaint throughout 24 hours. The Contractor should quote their rates accordingly.
50Note:- 1. 1. The Agency has to submit police verification record & ID proof of each staff. 2. The firm shall provide each staff with working cell phone. 3. The staff may be deputed for duty as per instruction of concerned SDE (E)/JTO (E). 4. Penalty shall be imposed in case of absence of any staff as per T & C of contract. 5.The GST / other Input Tax Credit (ITC) taxes shall be quoted by the firm as applicable as per latest amendments of GST Rules. 6.The contractor shall provide correct tariff heads & other details to enable BSNL claim Input Tax Credit. 7.Bidder must mandatorily quote for all GST components (CGST, SGST, and IGST) as required. 8.The bidder who submits the offer with concessional Goods and Service Tax (GST) shall submit the proof of applicable concessional GST. In case the Concessional GST is not creditable to BSNL it should be included in the price of the goods/services. 9. The FF & packing amount quoted shall not be subject to change after bid evaluation /ordering on account of change of copper, lead base price, change in duties & taxes of item etc. 13. Bidder must mandatorily mention HSN & SAC numbers. 14. Evaluation of bids: - The evaluation and comparison of responsive bids shall be done on the basis of Net cost to BSNL on the prices of the goods & Services (i.e. complete work) offered along with all applicable Taxes, packing Forwarding Freight & Insurance charges etc. exclusive of GST. Declaration by Bidder 1.We hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the GST Act introduced w.e.f. 1 July 2017 and further extended on more items till date. 2. We hereby certify that HSN/SAC shown in column 17 are correct & credit of GST for the amount shown in column 14 above are admissible as per GST Laws. Name of bidder: Seal of Company: GST No./(s)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail