Tender For Construction Of Foot Over Bridge ( S ) In The Proposed Kilambakkam Sub-Urban Train Halt Station Opposite To Kcbt And At Road Crossing At Kcbt With Escalators And Lifts, Chengalpattu-Tamil Nadu

Chennai Metropolitan Development Authority-CMDA has published Tender For Construction Of Foot Over Bridge ( S ) In The Proposed Kilambakkam Sub-Urban Train Halt Station Opposite To Kcbt And At Road Crossing At Kcbt With Escalators And Lifts. Submission Date for this Tender is 14-02-2024. Foot Over Bridge Tenders in Chengalpattu Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42009441
Tender For Construction Of Foot Over Bridge ( S ) In The Proposed Kilambakkam Sub-Urban Train Halt Station Opposite To Kcbt And At Road Crossing At Kcbt With Escalators And Lifts
Open Tender
Indian
Tamil Nadu
Chengalpattu
14-02-2024

Tender Details

Construction Of Foot Over Bridge ( S ) In The Proposed Kilambakkam Sub-Urban Train Halt Station Opposite To Kcbt And At Road Crossing At Kcbt With Escalators And Lifts

Key Value

Document Fees
Refer document
EMD
INR 2860000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of foot over bridge(S) in the proposedKilambakkam Sub-urban train halt station opposite to KCBT and at road crossing at KCBT With escalators and lifts
Sl. No. Item Description
1Civil Works
2Clearing Heavy jungle and surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish, lead upto 50 m, Transportation, and labour charges etc., complete complying with standard specification.
3Dismantling, removing, carefulluy stacking Corrugated Iron Sheet Roofing without roof timbers, complete complying with standard specification and as directed by the deparmental officers at the site,
4Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.complete complying with standard specification and as directed by the deparmental officers at the site.
5Demolishing Reinforced cement concrete using deploying machineries, including disposal of material / debris and carting within the site etc. Rate shall include for cutting of reinforcement steel of any size and shape with necessary tools and plants, scaffolding, water and power charges, cleaning the surface etc., complete and as directed. The rate shall include for stacking neatly and handing over the reinforcement steel removed from the dismantled concrete.
6Dismantling of Existing Asphalt surface to the required depth using milling machine including hire and running charges for the machine cleaning the milled surface as to avoid slippery including all other incidential charges and other unforeseen charges etc. complete as per standard specifications
7Earth work excavation for foundation with all intial leads and lifts in all kind of soils and to the required depth as may be directed except hard rock requiring blasting inclusive of shoring. strutting and bailing out water and depositing the surplus earth in places shown and levelling the site with all leads and lifts etc, complete complying with standard specifications and as directed by Departmental Officers (Foundation, Footings, Plinth Beams, Pilecaps, Tie Beams, Sump, Chambers, and other substructure works)
8(0 - 2m Depth)
9(2 - 3m Depth)
10(3 - 4m Depth)
11Supplying and Filling withM - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification.
12Providing and laying plain cement concrete1 : 4 : 8 ratio of (1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement including dewatering wherever necessary and laid in layers not more than 15 cm thick and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification.
13Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 250 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge.
14Carting away surplus excavated earthavailable with in the campus, is to be carted to the required locations within the campus. The rate shall include loading into the tipper/ lorry, transporting and unloading, leveling, breaking of clods, consolidating and sectioning the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
15Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including "C" & "U" clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
16For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc.
17For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
18For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc
19Providing & Fixing roofing consist of 0.8 mm thick galavanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100 X 100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beams with shear studs. The rate including all the fixtures and erection charges complete as directed by the engineer in charge.
20Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC tems of works with minimum cement content of 400 kg and maximum water cement ratio of 0.45, including admiture (plasticiser super plasticiser) recommended proportions as per IS:9103 to accelerate, retard seting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg of M-Sand, but excluding cost of reinforcement gril and fabricating charges, centering and shuttering and also including laying. vibrating with mechanical vibrators, fnishing. curing. etc. and providing fixtures like fan clamps in the RCC floor roof slabs wherever necessary without claiming extra, etc complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials)
21For footing and basement
22For Ground level
23For Deck slab
24Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
25Providing Fusion Bonded Epoxy coating not less than 175microns thickness and upto 300 microns to reinforcement of all diameters as per IS 13620/1993 including testing of coating at plant.The cost is inclusive of cost on account of careful handling, PVC coated binding wires, touchup material supplied by coating agency, repair work, loading, unloading and strengthening of bent rods etc., complete as per specification and as directed by the Engineer in charge
26Supplying & Erection in position of Structural Steel sections :Providing and fixing in position Hot rolled structural steel Members / Sections consists of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, flats etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint of Akzonoble make and total dry film thickness 225 microns. (Only Main structural supports related to Facade works if required any shall be considered and no base frame or support structure shall not be considere, which shall form part of the respective cladding and Glazing items). Refer Particular Specification for Mode of measurement for this item. The rate including the cost of all materials,labour,tools,tackle and plants, wastage etc.,as per specification and drawings complete. The rate including cost of bolts, nuts, washers, welding, electrodes and connections required for the work. No extra on this account will be paid for. The rate to include preparation of fabrication shop drawings for departmental engineer-in-charge approval before commencement of work.
27Providing & Grouting of Baseplate with M 60 Gradecementitious grout (Non Shrink) of approved make by suitable means (Free flowing / pump), curing etc., complete as per directions of Engineer-in-charge. (The payment shall be made on the basis of actual weight of approved grout injected)
28Supplying and installation of sandwich roof panels 50MM -PPGL -AZ70 sheet of -0.40/0.30mm of specified colour (structurally insulated puf sandwich panels) manufactured in completely automatic continuous production line using high pressure mixing production method running with uninterruped power supply, the puf panel is CFC free and Non- Ozpne Depeleting.The rate including cost of alltransporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying,fixing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge
29Paving the flooring with CEMENT CONCRETE TILES hydraulic pressed Antiskid tiles as per pattern design 20mm thick in cm 1:3 including pointing with colour cement etc., complete.(ISI). The rate including labour charges compelete as directed by the engineer in charge.
30Supplying and laying of flooring with quality approved make Ceramic Tack Tiles (seamless joint) confirming to IS 13006/EN 176Group B1a with technical specification as Mohs scratch hardness minimum7,Water Absorption of less than 0.5%, Modulus of Rupture greater than 35 N/mm2, Deep Abrasion resistant maximum 175 mm 3 Surface flatness, Straightness of sides ± 0.25%, thickness± 5% of size ofapproved colour and size & thick as specified below, setin 20mm thick C.M.1:4(1 cement and 4 manufactured sand )and pointing with white cementto matching colour shade as per Manufacturer"s Specification and as directed.Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, work atall levels and as directed. Rate shall be inclusive of forming pattern as directed byEngineer-in-charge. etc; as complete in all respects and complying with relevant standard specifications and as directed
31Supply & Laying flooring with best quality approved colour Granite Slab, (Black ribbed / BlackLeather granite ) not less than 18 mm thick of size not less than 1200 X 600mm machine cut and set in CM 1:4 20 mm thick topped white cement slurry (for surface contact of the bottom of the slab as per approved pattern including the finish joints with matching shade cement slurry cutting edge chamfering and polishing rough medium nice and tin oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportation charges, loading & unloading charges, preparation of surfaces necessary hacking in RCC surfaces cutting to required shape, edges, tools and plants curing, cleaning, acid wash over finished surface protection with Gypsum / pop layer over plastic sheet and removing the same before handling over as complete with all respect complying with relevant standard specification and as directed by the Engineer in charge
32Supplying and fixing 6mm thick multi wall polycarbonate sheet of 1.21m width and full length for the width of opening over the MS tubular truss and purlin. The joints of polycarbonate sheets will be done with extruded aluminium section of 50mm width and 2mm thick with necessary rubber beadings and filled with rubber sealent. The bottom aluminium extruded section is to be fixed over the MS arch member and using self tapping screws. The colour of the sheet is to be approved by the Executive Engineer. The rate inclusive of cost of sheet, labour charges for erection, transportation charges, aluminium extrusions, rubber beadings, silicon sealant, making the sheet to required shape etc., complete and as directed by the departmental officers. excluding steel Quantities
33Painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. The rate including cost of materials, brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
34Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
35Supplying & Erection in position of Structural Steel sections :Providing and fixing in position Hot rolled structural steel Members / Sections consists of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, flats etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint of Akzonoble make and total dry film thickness 225 microns. (Only Main structural supports related to Facade works if required any shall be considered and no base frame or support structure shall not be considere, which shall form part of the respective cladding and Glazing items). Refer Particular Specification for Mode of measurement for this item. The rate including the cost of all materials,labour,tools,tackle and plants, wastage etc.,as per specification and drawings complete. The rate including cost of bolts, nuts, washers, welding, electrodes and connections required for the work. No extra on this account will be paid for. The rate to include preparation of fabrication shop drawings for departmental engineer-in-charge approval before commencement of work.
36MS Elevation features with 175mm thk bracings and metal slats of 50 x 50mm box sections at 150mm spacing as per detail
37Plastering 15 mm thick for external surfaces with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer"s Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.
38Supplying and Fixing Silver Stainless Steel Perforated and Mesh Railing System. The rate including all the channels and fixing and includes the cost of transportation and labour charges complete as directed by the engineer in charge.
39Supplying and Fixing Gypsum Ceiling 60cm x 60cm. The rate including all the channels and fixing and includes the cost of transportation and labour charges complete as directed by the engineer in charge.
40FURNITURE AND ELEMENTS
41Supplying and fixing of Twin Tiliting type litter bin of 80 litres capacity . The frames for tilting and the bins are of Stainless Steel make. The material quality should be approved by the Executive Engineer. The rate including the cost of materials, transportation, labour for fixing, etc complete as directed by the engineer in charge.
42Map Sign: Providing, making and fixing Modular system signage of Vista, Co-sign or as per approved make system for Direction Signs, Maps as per concept drawings. Modular sign using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns) according to ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards 2 mm aluminium sheet face panel, 1.2 thick clear imported polycorbanate sheet, powder coated MS structure with graphics on 3m media (3M - IJ 1229), with 3M matt lamination and warranty as per manufacturer"s specifications. Sections can be used to create totems upto 6m with variable depths as per requirement. Fixing using anchor bolt, system cost with double side graphics. The Rate shall include fixing and printed matter (both side), protective coating (both side), Co-sign profile, finishing good etc. for all height all level but exclude the cost of all civil work related to foundation. The contractor should submit the drawings based on concept design and do the sampling and get it approved before mass production. The contractor shall submit the drawings based on concept design and do the sampling and get it approval before execution.
43Supply and constructing cement concrete solid block masonry work at all levels in cement mortar 1:5 (1 of Cement : 5 ofmanufactured sand ) using Portland Pozzolana Cementstandard size of 400 x 200 mm and 200 mm thick of solid cement concrete with minimum compressive strength of 5 N/Sq.mm.conforming to IS 2185 or equivalent BS and Fly ash conforming to IS : 3812 (Part III)-1966* may be used for part replacement of fine aggregate up to a limit of 20 percent complete and as directed. Concrete blocks manufactured under strict quality control conditions using modern rugged block casting and stripping machine with the latest mouldingtechniques etc,. only shall be used. The rate including cost of all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge
44WATER AND PLUMBING
45Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification for 110 mm dia
46Supplying and fixing of Gutter -G.I. sheets 30cm wide and 1.6mm thick over the length of the span for the rain water collection. The rate including all the necessary fittings and labour charges for fixing complete as directed by the engineer in charge.
47Electrical Works
48CT Metering Panel (as per the TANGEDCO norms) - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps,internal wirings, Digital voltmeter and Ammeterand other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring. 1set of125/5A CT with TNEB metering provision and 1 nos of 125A /5A CT for APFC.. For all items in this section, the rate includes necessarysupports as required at site. No extra payment will be made for the same. Rate shall inclusive of factory witness testand all accessories, breakers , control wiring, models has to be followed as per in the technical specification.
49125A Isolator Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of 100A TPN MCCB panel, cubicle type, Free standing, floor mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors,
50APFC PANEL Supply, installation, testing and commissioning of 20 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. Incoming of1 set of 63 A ,16kA,TPN Aluminium Bus Bar. outgoing of. 20A,TP MCB with Suitable contactor with 5KVAR Heavy duty capacitor - 3Nos, 10A,TP MCB with Suitable contactor with 2KVAR Heavy duty capacitor - 1No.6A,TP MCB with Suitable contactor with 1KVAR Heavy duty capacitor - 2Nos.6A, TP MCB with Suitable contactor with 0.5KVAR Heavy duty capacitor - 2Nos. start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., all inclusive.
51Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 1450 X L 1400 X D 400 ) mm with suitable to accommodate 125A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source , 1no 100A 4Pole MCCB, 1no of 100A 4Pole MCCB,4nos of 63A 4Pole MCCB"s,and 1no spare compartment for as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 33x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers.
52Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 1850 X L 1600 X D 450 ) mm with suitable to accommodate 400A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source , 1no 160A 4Pole MCCB, 1no of 125A 4Pole MCCB,and 4nos of 63A/40A 4Pole MCCB"s,compartment for as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 33x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers.
53LIFT Supplying, erecting, testingand commissioning of machine room less passenger Elevator having 13 passengers capacity, ratedspeed 1.0 mtr. / sec., for Basement, Ground , 1st floor and Second Floor400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding,simplex full collective with / with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman"s switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:-Clearopening and Transportation Charges including Loading and Unloading Charges etc.,
54Escalators Design, Supply, Installation, Testing, & Commissioning of Escalators, total rise distance 5 M approximately and inclination angle 30 deg. step width 1000 mmand escalator shall be capable of operating at 0.5 m/s with 2 persons on each tread, emergency push Buttons at upper and lower newel post as per technical data sheet & specification & work shall be carried out as per direction of engineer in-charge. Escalators shall conform to ANSI part VIII / EN 115 or more to stringent local requirements in construction, operation safety and installation and approved make and shall comply with all statutory requirement of the local Competent Authorities. The Rate shall includes providing and fixing of all three sides with1.2 mm thick SS cladding with required supports.The method of control shall beVVVF control. The rate quoted shall include all materials & Accessories required to complete job.From Lower Level to Ground Floor for height of 500 mm (approximately) and width of 1000 mm with the 30 degree inclination angle for outdoor application and Transportation Charges including Loading and Unloading Charges etc.,(Rising and Lowering )
55VERTICAL THREE PHASE and Neutral MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof12 way verticalTPNMCBsheetsteel Industrial Type TPMCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 125A FP MCB as Incoming and 6 Nos.of63A & 32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPNMCB DB with IP54 Protections)
56Supply and fixing of 7 segment12 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (3 x 12 ways in each segment) and seperate provision for MCB / Isolators ( totally 36 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only.
57Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal /acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 40A/32A 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating one no. 25A, 30MA 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and separate provision for 6A-32A SP MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only.
58Supply and fixing of 63A TPN MCCB WITH ENCLOSURE-for Lift. The Enclosures shall be IP 65 with transparent flaps or Doors. The Enclosureshall have flaps to access the circuitsbased on the specific circuit requirements. The doors / flaps shall be made of Thermoplastic Polycarbonate and the rest of the Board shall be made of Polysterene.In case of extreme outdoor conditions as high UV radiation, the board shall be made of complete Polycarbonate material ( Please follow special remarks at the end of the specifications). The Distribution board shall be surface type and internal screws used for mounting Din Rails & fixing of the board shall be made of stainless steel V2A screws.Blanking strips shall be provided to ensure closure of unused module spaces. The Enclosure shall be with multi-level knockouts for cable glands.(Lift Control )
59Supply and fixing of 12way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) 1No. 32A 30 MA 4 Pole ELCBas incoming and10 Nos. 6A to 32A SP MCB outgoing in flush with wall. The MCB DB and MCB"s should be with ISI mark (like standard make)
60Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection(For AC Plug)
61SUPPLY OF NERI - ARCHITECTURAL LINEAR DIFFUSED PROFILE LED LIGHT FIXTURE - NLP-D-15, 14-16W, LED, 3000k, IP 66, 1M Length - NLP-D-15 : The housing in light weight, made of high strength aluminium. Diffused screen in PMMA with high impact resistance. Pure Polyester powder coating in Standard Grey Colour.IP Rating : IP66 Length-1000mm,Height – 40mm, Width.- 30mm, Weight - 0.8Kgs. Power LED Module with high efficacy LED"s, on Printed Circuit Board with metal core plate. Common external electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection. Estimated LED Lifetime is L70-50,000 hours minimum - LM80 report from LED Manufacturer should be submitted. Minimum Light fixture Lumen output is 550Lumens. Sample Should be submitted for concerned engineer incharge for approval of light fixture.. (98Nos of 3M Length)
62SUPPLY OF NERI - ARCHITECTURAL CEILING SURFACE MOUNTED LED LIGHT FIXTURE - NCL-02M-Ceiling Light, 35-45W, LED, 3000k, IP 65 - Body in cylindrical shape made of die cast aluminium using pressure die casting process & Protection screen in clear tempered glass with high impact resistance (IK 08).Body is finished with Pure Polyester powder coating in RAL 9005 MAtt. Precise structure and multi-protection silicon gasket ensures ingress protection- IP 66 . Dimension-168mm (Dia.) x 150mm(H), Weight-2.1kg. LED source is of high efficacy COB. Colour Rendering Index: Ra > 80. Electronic Driver which offers Protection against Short Circuit, Over- Voltage & Over- Current. Estimated Lifetime-L70 @ 50,000 hours minimum. LM80 report from LED Manufacturer should be submitted. Sample should be submitted for approval from concerned engineer-in charge
63Supply and Fixing of100W LED FloodLight Fitting with LEDwith PVC unsheathed copper leads from terminals to the fitting and Suitable LED Street Light Pipe with suitable Clamps and Crews etc, Complete.(GI) (Make:Crompton/ Philips/Havells)
64The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates,materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fasteners, welding, anchor bolts, nuts etc.The rack shall have suitable cable clamping arrangements etc."Cable Tray /ladder should be powder quoted as match with ceiling colour as per PWD requirements. The rate shall inclusive of necessary Wedge anchors threaded rods,nuts & bolts, making clamp for rcc roof fix/ perlin/Truss, cable tray clamps etc, (8 mm threaded rod supports shall be providedat not more than 2 mtr center to center and as per site requirement )
65Supply and fixing ofGI Hot Dip / Powder Coated 16 SWG Cable Tray with 450mm width and 50mm height
66Supply and fixing ofGI Hot Dip / Powder Coated 16 SWG Cable Tray with 300 mm width and 50mm height
67Supply and fixing ofGI Hot Dip / Powder Coated 16 SWG Cable Tray with 150mm width and 50mm height
68Supplying and fabricating of MS structural steel supports for various applications using U channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above.
69Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required.
70Supply and laying of 31/2 core300 Sq.mm PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
71Supply and laying of 31/2 core120 Sq.mm PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
72Supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
73Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
74Supply and Laying of 31/2 x 25sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good
75Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
76Supply andlaying of 3CX2.5sqmm Cu. armoured LTUG Cablein the existing cable trench
77Supply and clamping of following XLPE armoured LTUG cable on post or on wall MS-Clamps , Saddles, plugs, Screws etc., as required.
78Supply and Clamping of 3 1/2 core x 300 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
79Supply and Clamping of 3 1/2 core x 120 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
80Supply and Clamping of 3 1/2 core x 70 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
81Supply and Clamping of 3 1/2 core x 50 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
82Supply and Clamping of 3 1/2 core x 35 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
83Supply and Clamping of 3 1/2 core x 25 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
84Supply and Clamping of 4C x 16 Sq.mm PVC armoured LTUGaluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
85Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection.
86Supply and fixing of brass cable gland for3 1/2 Cx 300 Sq.mm PVC LTUGarmoured cable with earth connection
87Supply and fixing of brass cable gland for3 1/2 Cx 120 Sq.mm PVC LTUGarmoured cable with earth connection
88Supply and fixing of brass cable gland for3 1/2 Cx 70 Sq.mm PVC LTUGarmoured cable with earth connection.
89Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGarmoured cable with earth connection
90Supply and fixing of brass cable gland for3 1/2 Cx 35 Sq.mm PVC LTUGarmoured cable with earth connection
91Supply and fixing of brass cable gland for3 1/2 Cx 25 Sq.mm PVC LTUGarmoured cable with earth connection.
92Supply and fixing of brass cable gland suitable for4C x 16 PVC armoured LTUG cable with earth connection.
93Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection.
94Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable)
95Supply and providing cable end termination of 3 1/2Corex 300 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
96Supply and providing cable end termination of 3 1/2Corex 120 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
97Supply and providing cable end termination of 3 1/2Corex 70 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
98Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
99Supply and providing cable end termination of 3 1/2Corex 35Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
100Supply and providing cable end termination of3 1/2Corex 25Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
101Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
102Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete.
103Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)( 4points / Coil)
104Lift ShaftLED Light with Wiring : Wiring, Connecting, Testing & Commissioningfor lift well light point and 6Amps power socket outlet for all 4 floorswith 2 x 2.5 sqmm FRLS PVC insulated stranded copper conductor of 1100V grade along with 1 x 2.5 sqmm FRLS PVC insulated standed copper conductor cable as earth wire inMS conduit including providing and fixing switch box, 2 Nos. of 5A single way module switch (for controlling light point and socket Outlet ) for each floor of the lift well , with bulkhead lamp 1 No. 5A 5 Pin shuttered socket outlet with flush type switch for each floor of the lift welland making necessary connections complete etc.( 6 points)
105Wiring with 3R x1.5 sq.mm. (22/0.3) PVC insulated unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1 run of 2.5 Sq.mm wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point.
106Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil).
107Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)
108Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour.
109Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour.
110Supply and fixing of thermoplastic loop - in and loop out boxes with lid of dimension min104X104X70MM with 20A connector. shorting link 2 way necessary and along DIN rail terminal block. The Junction Box shall be insulated and made out of high grade thermoplastic. The JB shall be IP Rated for outdoor applications, environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid& anti corrosive. The JB shall be rated for Degree of Ingress Protection IP 65 in accordance with IEC 60529.
111Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Scope cover wall cutting , grouting , flushing and making good on the wall.
112Supply and fixing of manufacturer"s GI metal back box and3 nos of 6A modularswitch, 3nos of 6A 3 pin combined modular type wall socketin flush with wall mounted on poly carbonate front plate with switch mounting metal parts, in flush with wall.
113Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wallwith connections. Scope cover wall cutting , grouting , flushing and making good on the wall.
114EARTH SYSTEM
115Earthing as per the ISI specification with an earth electrode of 2.10 metre Class "B" GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
116Supply, fabrication, of GI /Copper earth flatof following size in provided trench, clamping in wall, ceiling, with suitable Clamps/ saddles, connecting the joints through bracing / welding covering withtermination in the earth pits, Panels, Distribution boards and equipment"s with bitumen paint including accessories wooden plugs, screws, fastener etc., all inclusive
117Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection
118Supply and run of 25mm x 6mm GI flat with necessary clamps / supports on wall / floor / ground for earth connection
119Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
120Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
121Supply and Run of 2 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceilingwith painting of suitable colour.
122FIRE SAFETY
123First Aid Box complete with all First Aid Medicines
124Shock Treatment Chart fixed in glass frame
125Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms
126Danger Board as required by the Electrical Authorities
1272m x 1m Rubber Mat suitable for 11 KV installation confirming to IS(5 set)
128Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
129Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT /SAFETY FIRST / EQUIVALENT
130CCTV SYSTEM
131Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 6T Hard Disk Drive 4 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output ? HDMI1 / VGA1 outputs provided ? HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access ? Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony
132Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification: ?1/2.5" Progressive Scan CMOS, ? 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection) ? Face Detection ? 120dB WDR, ? BLC/3D DNR/ROI, IP67 complied ?On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ? Shutter Speed 1/3 s to 1/100,000 s, ? 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ? rotate: 0° to 360°, 2.8 mm, ? horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ?Lens Mount M12 ? IR Range I5: up to 50 m, ? Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ? Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ? Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Dahua/Panasonic)
133Supply ,Testing and Commissioning of Dom Camera 8MP IR camera
134Supply, Installation, Testing and Commissioning of 32" smart LED TV with following specifications a) Full HD b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remote (Make: Sony/ LG /Samsung).
135Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories.
136Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm.
137Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges.
138Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 °C ~ +75 °C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line.
139Supply and fixing of POE 8 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 °C ~ +75 °C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK)
140Supply and fixing of Out Door Weather Proof Box 2Ft x 2Ft Out Door Weather Proof Box 2Ft x 2Ft
141Supply and Fixing of Rack with Accessories -Higher end 42 U Rack with LNS unit and fan extra for the above rack.
142Supply and fixing of 2 feet CCTV Camera Stand with attachment fittings as follows: * Weather heads and couplings * Cabinet mounting fittings, plates, brackets as needed. * Reinforced couplings for wire entrances to cabinets.
143Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up
144Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 1 Hours back up
145PA SYSTEM
146Supply, Installation, Testing & commissioning of 30 watts wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response. Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable. It has impedance of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make: AhujaAMH402T/Bosch or its equivalent)
147Supply and Installation of 15 watts indoor Wall Speaker with Line Matching Transformer in the existing pole with supporting clamp Model:- Specification:- 1.Input Power : 15W RMS/20W Max 3. Frequency: 250-10,000Hz 4. SPL:108dB/1W/1m,122dB/25W/1m at 1kHz 5. Power Taps: 40/30/20/10/5W (Make: Ahuja, Bose, Yamaha or equivalent)(Make: AhujaAMH402T/Bosch or its equivalent)
148Supply, Installation, Testing & commissioning of 240 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the input channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make: Ahuja SSA 10000/Bosch or its equivalent)
149Supply, Installation, Testing & Commissioning of10" gooseneck with suitable base incorporates separate bush switches for momentary and dynamic microphone with 600ohm impedance and has 2.5mv/pa sensitivity and frequency response ranging from 50-15000hz with multi tone chime model.(Make:-ACM66 Ahuja/Bosch/its equivalent)
150Supplyand run ofArmoured Speaker Cable 2 core 1.5 sqmm PVC insulated SC unsheathedof 1100V Grade in suitable PVC conduit pipe onconcealed wall and ceiling with painting of suitable colour.
151Supply & Installation of custom built M.S Powder coated wall mounting Audio rack with Lock & key for housing of Amplifier & player/Recorder conforms to EIA-310,IEC-60297 and able to withstand the load of 40kg with welded construction made up of CRCA steel with suitable height, width and depth.
152Supply, Installation, Testing & Commissioning ofCordless mic UHF model.(Make:-ACM66 Ahuja/Bosch/its equivalent)
153CEIG licence and inspection charges
154TNEB Service connection Charges
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail