Government Medical College-GMC has published Tender For Supply Of Neuro Implants In Nuerosurgery Department In Hospital. Submission Date for this Tender is 23-02-2024. General Use Diagnostic Assessment Products Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

41998585
Tender For Supply Of Neuro Implants In Nuerosurgery Department In Hospital
Open Tender
Indian
Rajasthan
kota
23-02-2024

Tender Details

Supply Of Neuro Implants In Nuerosurgery Department In Hospital , Anterior Cervical Plating System ( Variable Angle Screws System ) A ) Single Plate Must Provide The Option Of Rigid, Toggling And Hybrid Construct. B ) The Angulations Must Be Of 28 Degree Cephalad / Caudal Range With 8 Degree Of Off Set. C ) Locking Mechanism Of The Screws Must Be One Step Locking Should Block The Screws From Coming Out. D ) The Thickness Of Plate Must Be 2.0Mm Or Less And Width 16.5 Mm E ) The Core Diameter Of The Screws Must Be 3Mm With Outer Diameter Being 4.0Mm And 4.5Mm. F ) All The Screws Must Be Colour Coded And Available In Self Tapping As Well As Self Drilling Options. G ) The Plates Must Be Available In All Sizes.- , I Level , Ii Level , Iii Level , Cervical Peek Cage A ) The Cage Must Be Radiolucent With Sharp Teeth Inter Body Fusion Cage System Of Implants And Instruments Designed For Anterior Cervical Interbody Fusion ( Acif ) And Should Be Compatible With Anterior Cervical Plating System ( Acp ) .B ) The Cages Must Be Curved Cages, Which Mimic The Curvature Of The Healthy Endplate. C ) The Cages Must Be Wedge-Shaped Cages, Which Match The Flattened Degenerated End Plate. D ) All Implants Must Be 15Mm Wide And 12.5Mm Deep And Are Supplied Sterile Pre-Packed. E ) The Available Implant Heights Must Be - , The Available Implant Heights Must Be 5Mm , The Available Implant Heights Must Be 6Mm , The Available Implant Heights Must Be 7Mm , The Available Implant Heights Must Be 8Mm , The Available Implant Heights Must Be 9Mm , The Available Implant Heights Must Be 10Mm. , Expandable Cervical Corpectomy Cages A ) Expandable Vertebral Body Replacements For Cervical & Upper Thoracic ( C3-T2 ) Spine B ) Should Have Continuous Expansion System So That Height Can Be Achieved C ) Should Have Rapid & Controlled In Situ Expansion D ) Should Have Locking Clip To Secure The Expanded Implant To Prevent Micro Movements. E ) Should Have Foot Print Of 11.9 Mm X 15.0 Mm F ) Should Achieve Height From 17Mm To 70Mm & Angle From 4.5 To7 Degree G ) Should Be Made Of Medical Grade Titanium Material , Locking Cervical Cage With Plate A ) Expandable Vertebral Body Replacements Cage With In Built Cervical Plate For Fixation In Situ With In The System For Cervical & Upper Thoracic ( C3-T2 ) Spine. B ) Should Have Continuous Expansion System So That Desirable Height Can Be Achieved C ) Should Have Rapid & Controlled In Situ Expansion With Plate Providing The Option Of Rigid, Toggling And Hybrid Construct D ) Should Be Made Of Medical Grade Titanium Materiale ) Locking Mechanism Of The Plate Screws Must Be One Step Locking Which Should Block The Screws From Coming Out.F ) All The Screws Must Be Colour Coded And Available In Self Tapping As Well As Self Drilling Options. G ) The Core Diameter Of The Screws Must Be 3Mm With Outer Diameter Being And. H ) The Plates Must Be Available In All Sizes- , G ) The Core Diameter Of The Screws Must Be 3Mm With Outer Diameter Being And. 4.0Mm , 4.5Mm , H ) The Plates Must Be Available In All Sizes- I Level , Ii Level , Iii Level , Cervical Disc Replacement A ) Superior And Inferior Implant Plate Made Of Cobalt-Chromium Molybdenum Alloy According Iso 5832-12. B ) Plasma-Sprayed Titanium Coating. C ) Inlay Made Of Ultra-High Molecular Weight Polyethylene ( Uhmwpe ) D ) Ball And Socket Principal – Metal On Polymer. E ) Modular Anatomical Design. F ) Optimal Primary Stability Due To H Keel Anchorage Of The A Prosthesis In The Vertebral Body. G ) Anatomical Foot Print Design For Maximum Endplate Coverage. , H ) Six Different Footprints Available For Optimal Coverage Of The Vertebral End Plate : M , Md , Ld , Xl , Xld , I ) Three Different Heights ( 5, 6 And 7Mm ) Allowing Adjustments To The Individual Dimensions Of The Patient’S Disc.5 , Three Different Heights ( 5, 6 And 7Mm ) Allowing Adjustments To The Individual Dimensions Of The Patient’S Disc 6 , Three Different Heights ( 5, 6 And 7Mm ) Allowing Adjustments To The Individual Dimensions Of The Patient’S Disc. 7 , Lumbar Disc Replacement A ) Superior And Inferior Implant Plate Made Of Cobalt-Chromium Molybdenum Alloy. B ) Ball And Socket Principle- Metal On Polymer. C ) Inlay Made Of Ultra-High Molecular Weight Polyethylene ( Uhmwpe ) D ) There Must Be Vacuum Plasma Spray Coatinge ) There Must Be Primary Stability Through Central Keel. F ) Angulations Selection Must Be From: , Superior Plate: 3 °, 6° And 11° , Inferior Plate: 0°, 3° And 8 , Combinations : 3°, 6°, 9°, 11° , Posterior Cervical Fixation System ( Lateral Mass Fixation System ) A ) The System Should Have Cancellous Bone And Cortex Screws. B ) The System Should Have Locking Screws For Angularly Stable Locking And Fixation Of The Rod. C ) The System Must Have Self Tapping Screws. D ) The System Must Have 3.5Mm Ti Rod. E ) The System Should Have Oc Fusion Option. F ) The System Should Offer Hooks. G ) The System Should Have Cortical Profile Bone Screws :3.5Mm With 2Mm Increments. H ) The System Should Have Rod = 9Mm. I ) The System Should Have Transverse Connector: 60Mm And 75 Mm. J ) The System Should Have 3.5Mm Ti Transverse Bar.K ) The System Should Have Occipital Plate / Rods. , L ) The System Should Have Cancellous Profile Bone Screws : I. 3.5Mm With 2Mm Increments. , Ii. 4.0 Mm With 2Mm Increments. , M ) Shaft Screws Should Have 10Mm Unthreaded Portion Rods : I. 3.0Mm , 3.5Mm Ti Rod. , Ii. 3.5Mm / 5.0Mm Ti Rod. , Iii. 3.5Mm / 6.0Mm Ti Rod. , Mesh Cage For Vertebral Body Replacement The Mesh Cage Must Be Available In The Following Specifications And Must Come Along With Press Fit End Rings: , A ) Mesh, Round ( For Cervical ) I. 10Mm: Heights 4-18Mm , Ii. 12Mm: Heights 4-88Mm , Iii. 15Mm: Heights 8-88Mm , B ) Corresponding Press Fit End Rings, Round I. Angles Of 00 Or 2.50 In 10Mm Diameter Options. , Ii. Angles Of 00 Or 2.50 In 12Mm Diameter Options. , Iii. Angles Of 00 Or 2.50 In 15Mm Diameter Options. , C ) Mesh, Oblong ( For Thoracic And Lumbar Region ) – I. Dimensions: 17X22mm, 22X28mm And 26X33mm – Heights: 6-88Mm , Ii. End Rings, Oblong Angles Of 00 Or 50For The Corresponding Dimensions; 17X22mm, 22X28mm And 26X33mm. , Cv Junction Fixation System ( Occiput To C2 ) A ) The System Should Have Medial And Lateral Plates Of 50Mm & 60Mm, One & Two Hole Clamps Which Must Allow The Medial And Lateral Rod Placement, And Should Be Able To Give 15 Degree Of Screw Angulations B ) The System Must Have Straight And Pre Contoured ‘3.5Mm Rods. C ) The System Should Have Blunt 4.5Mm Occipital Screws Qrid 5Mm Emergency Screws With 4-18Mm Lengths.D ) The System Should Have Screwdriver Shaft Stardrive T15, Self Holding, With Cordan Joint As Well As Straight, For Quick Coupling. E ) The System Must Have The Templates Of Occipital Plates To Avoid Wrong Plate Selection. F ) The System Should Have Simple Locking Mechanism Of Each Screws. G ) The System Should Have Tap For Better Screw Purchase And 2Mm Torque Limiting Screw Driver For Final Tightening. H ) Following Components Should Be Available In System :I ) Occipital Plate ( T Or Y Shaped ) J ) Transverse Connector , 50Mm , 60Mm , One Hole Clamps , Two Hole Clamps , Cv Junction Fixation System ( C1 To C2 ) A ) The System Should Be Versatile, Must Have Set Of 6 Screws And Two Rods B ) The System Must Have Straight And Pre Contoured ‘3.5Mm Rods. C ) Titanium Made 3.5 Mm Diameter, Polyaxial Screw Of Different Lengths From 12 Mm To 36 Mm Length For Posterior Cervical Fixation. D ) The System Should Have Tap For Better Screw Purchase And 2Mm Torque Limiting Screw Driver For Final Tightening. E ) Joint Spacer Of Various Sizes Made Of Titanium , Zero Profile Anterior Cervical Interbody Fusion Devices A ) The Implant Should Act As Stand Alone Interbody Fusion Device For Cervical Spine With The Benefits Of Both As Interbody Spacer And As Anterior Cervical Plate. B ) The Implant Must Be A Combination Of ‘End Screw And Spacer’ & Where The Spacermust Automatically Align When Inserted. C ) The Implant Must Have Radio Opaque Marker For Posterior Visualization During Imaging And Teeth On Superior And Anterior Surface For Initial Stability. D ) Spacer Component Must Be Made Of Peek Optima ( Polyetherketone ) . E ) The Implant Must Have One Step Locking Screw And Screws Should Form A Bone Wedge With 40° 5° Cranial / Caudal Angle With 2.5° Medical Lateral Angle. F ) The Screw Must Come With Self Tapping And Self Centering Options With Titanium Alloy Material ( Ti-6Ai-7Nb ) G ) Implant’S Triobular Thread Cutting Flutes Should Be Self Centering. H ) The Implants Must Come In Parallel Lordotic And Convex Implants Sets With Heights Varying From 5Mm To 12Mm With An Increment Of 1Mm Each. I ) The Screws Must Come In 3.0Mm Diameter & Must Be Colour Coded By Screw Length Varying From- , 12 Mm , 14 Mm , 16 Mm , Odontoid Screw A ) Screw Should Made Up Of Tianium Alloy ( Tan ) . B ) Screw Should Be Cannulated. C ) Screw Should Be Self-Drilling And Self Tapping. D ) Screw Should Consist Of 12Mm Short Thread. E ) Screw Should Be Of 3.5Mm Ø. F ) Screw Should Be Available In The Length Of 36Mm To 50Mm. G ) The Whole System Should Thus Enable The Following-H ) Help In Preservation Of Atlantoaxial Mobility With Lag Screw Compression Technique. I ) With Wire Guiding Ensures Precise Positioning Of Implants & Instruments. , Top Loading Pedicle Screw System A ) Top Loading Pedicle Screw And Rod System For The Posterior Stabilization Of The Lower Back. B ) The Pedicle Screw System Must Have Polyaxial As Well As Monoaxial Head For Case Specific Manipulation. C ) The Polyaxial Head Should Offer 25 Degree Of Angulations About The Axis Of The Screw.D ) The Pedicle Screw System Must Have Dual Core Screws For Rapid Insertion And Secure Anchorage In Both, Cortical And Cancellous Bone. E ) The Screws Must Be Colour Coded F ) Single Step Locking Mechanism. G ) The Option Of Achieving Case Specific Lordotic And Parallel Compression With The Same System. H ) Curved Rods In 6Mm Diameter From Length 70Mm To 300Mm. I ) Straight Rod In 6Mm Diameter From 80Mm To 150Mm. J ) Monoaxial, Multiaxial And Reduction Screws Should Be Available. With Provision Of Persuader For Spondylo-Listhesis Reduction. , K ) Screw Dimensions Should Be-4.5Mm , 5.5Mm , 6.5Mm , L ) Diameter Length 30Mm , 35Mm , 40Mm , 45Mm , 50Mm , Trans Foraminal Lumbar Interbody Fusiona ) The Cage Must Be Radiolucent Made Up Of Peek – Optima Material With Sharp Teeth Designed For Trans Foraminal Lumbar Interbody Fusion ( Tlif ) . B ) The Cage Must Have Rounded Tapering Edges Allowing Easy Insertion Thus Minimizing Injuries To End Plates And Neural Structures.C ) The Cage Must Have 3 Titanium Markers ( Two Lateral, One Central ) To Indicate The Cage Position On X-Ray.D ) The Cage Must Have Injection Moulded Roughened Surface Promoting Bone Integration And On Growth.E ) The Cages Must Have Biconvex Shape Providing Even Distribution Of Compressive Forces Along The Endplates Thus Stability. F ) The Cage Must Have One Broad Graft Hole And Two Lateral Holes. G ) Implants Must Be Available In Two Footprints Sizes , 14 ( G ) -1 10X27mm , 14 ( G ) -211Mm , 14 ( G ) -312Mm , 14 ( G ) -4 13Mm , 14 ( G ) -5 15Mm , 14 ( G ) -6 17Mm , Posterior Lumbar Interbody Fusion A ) The System Should Be Able To Provide: - Adequate Stability Restores Disc Heightrestores Lordosispreserves The Integrity Of The Vertebral Body Endplates Provides An Optimized Fusion Bed B ) It Should Be Radiolucent Interbody Fusion System Of Implants And Instruments For Posterior Lumbar Interbody Fusion ( Plif ) . C ) Cage Must Be Made Of Peek Optima® Material Facilitating Radiographic Assessment Of Fusion. D ) Cage Must Have Two X-Ray Markers Integrated Into The Cages To Enable Easy Visualization Of Their Position Postoperatively. E ) Peek Material Used Must Contain No Carbon Fibres, Thereby Reducing The Risk Of Systemic Uptake And Local Inflammatory Response. F ) Cages Must Be Available In 6 Heights In 2 Mm Increments, And Should Be Supplied Sterile Pre-Packed. G ) The Optimal Anatomical Shape And Supportive Superior And Inferior Surface Design Of The Cage Should Reduces The Risk Of Subsidence Into The Adjacent Vertebrae. H ) The Cage Should Have Perforated Structure Which Must Allows For Bony Ingrowth Through The Cage And The Design Must Ensures Optimal Implant-To-Endplate Contact. I ) Cage Must Be Designed For An Optimal Fit Into The Natural Concavity Between Two Adjacent Vertebral Bodies. J ) Cage Must Have Teeth On The Superior And Inferior Surfaces Providing Additional Primary Stability. K ) The Cage Must Be Injection Moulded Peek Cage So That It Has Roughened Surface, Which Is Superior To A Machined Peek Surface In That Promotes Bone Integration And Ongrowth. , Anterior Stabilization Of Thoracolumbar Spine A ) The Implant Should Provide Anterior Stabilization To Thoracolumber Spine. B ) The Implant Should Provide The Plate And Rod Construct And Be Designed To Be Used Along With Either Bone Graft Or With A Vertebral Body Replacement. C ) The Implant Should Come With Instruments Which Are Designed For Use In Open, Minima-Open Or Endoscopically Assisted Approaches. D ) The Implants Should Come With Telescopic Mechanism With The Facility Of In Situ Compression And Distraction. E ) The Implantsshould Comein The Following Sizes : F ) Height Of The Implant Above Bone Without Posterior Locking Screws Should Be 7.7Mm And With Posterior Locking Screws Should Be 9.0 Mm And Convergence Of Screws Should Be Of 7.0°. G ) The Posterior Screws Should Be Of 7.0 Mm Diameter, Cannulated For Use With K-Wire, Dual Core And Double Lead. H ) The Implants Should Come With Polyaxial Bushings Which Allow An Angulation Of 15° For Screw Insertion Tailored To The Individual Anatomical Situation. , I ) Mono-Segmental:- 29-33 Mm , 31-37Mm , 35-45Mm , 41-57Mm , J ) Bi-Segmental :- 53-71Mm , 66-86Mm , Expandable Thoracic And Lumber Corpectomy Cages.A ) Expandable Vertebral Body Replacements B ) For Lumber & Lower Thoracic ( T5- L4 ) Spine C ) For Mono, Bi & Trisegmental Fusion D ) Should Have Rapid & Controlled In Situ Expansion.E ) Should Have Ratchet System So That Height Can Be Achieved F ) Should Have Foot Print Of22 X 21 Mm And 25 X 28 Mm G ) Should Achieve Height From 20Mm To 73Mm & Angle From -5°, 0°, 10°, 20°, -6°. H ) Should Be In Titanium Tan Alloy. , Low Profile Neuro ( Mini Plates ) A ) A Plating Systems To Offer Neuro Surgeons A Choice Do Rigid Fixations Of Craniotomies And Other Cranial Procedures Which Should Be Very Low Profile In Nature And Be A Complete System For A Broad Spectrum Of Cranial Indications Having Following Specifications Technically : B ) A Modular System Having Autoclavable Module For Instruments And Implantsc ) All Plates Are Should Be 0.5Mm Thick And Implants Should Be Offered In Various Shapes For An Optimal And Appropriate Choice In The Procedure There Should Include Basic Plates, Frame Plates, Adaption Plates-Available In Multi Holes, Burr Hole Covers, Burr Hole Covers For Shunt And Mesh Plates In Various Dimensions ( Both 0.4Mm & 0.6Mm Should Be Available ) . D ) Temporal & Mastoid Region Should Have Dedicated Plates For Use. E ) Screw / Plate Profile Should Be Not More Than 0.6Mm For Minimum Palpability.F ) Despite The Minimum Profile, The Plate Strength Should Be Comparable To Thicker Cranial Plates. G ) The Screws Should Be Designed For Hard Cranial Bones And Should Have A Plus Drive Recess For Excellent Screw Retention In The Shaft. H ) The Screws Should Have A Flat Head And Should Be Easy To Pick Up With A Self Holding Shaft. I ) The Screws Should Have A Selection Self-Drilling And Self Tapping Types. J ) Screw Lengths Should Be Available In 3-6Mm. K ) Emergency Screws Having Different Colour Than Regular Screws. L ) The Screw Driver Handles With Hexagonal Coupling. M ) Long ( 66Mm ) And Short ( 42Mm ) Shafts Which Should Be Self Holding In Nature And Compatible With All Screws In The System And Also Fit The Handle Instantly. N ) Holding Instrument For Plates Must Be A Part Of The Instrumentstion. O ) A Special Cutter For Strut & Mesh Plares To Be Provided In The System. P ) Appropriate 1.3Mm Drill Bits Of 4Mm & 6Mm Depth Having Stops. Q ) Appropriate Lable Clips For The Screws Which Should Be Replaceable. , Burr Hole Cover Plate , Cranial Fixation System For Craniotomized Bone Flaps And Bone Fragments In Neurosurgery ( Equivalent To Craniofix ) , Ha Coated Multiaxial Screws For Osteoporotic Spine Fixation A ) ( Implants Compatible With Vertebral Column Manipulation And Vertebral Body Rotation Rotation Instrumentation ) , B ) Open Ended Reverse Thread Toploading Top Tightening Fixed Angle Screws With Breako Off Type Of Plug ( Assorted Size ) - 4.5Mm , 5.5Mm , 6.5 Mm , C ) Open Ended Reverse Thread Toploading Top Tightening Multiaxial Screws ( Assorted Size ) - 4.5Mm , 5.5Mm , 6.5 Mm , D ) Reduction Screws, 4.5Mm , 5.5Mm , 6.5 Mm , 7.5 Mm , E ) Break Off Plugs F ) Reduction Break Off Plugs G ) Transverse Connectors ( Assorted Size ) H ) Staples -13Mm , 15Mm , 17Mm , I ) Double Rod Staplerostral And Caudal J ) Domino’S Axial Connectors K ) Reverse Thread Top Loading Top Tighteneing Pediatric Hooks-Upper Thoracic, Laminar, Pedicular Small And Medium, Right / Left Offset, Angled Hooks. 21Mm , 23Mm , 25Mm , Percutaneous Pedicular Screw Systemsfor Multilevel Fixation ( For Mis System ) A ) The Minimal Invasive Pedical Screw System Must Be Offered That Is Suitable For Offset 3 Levels Of Fixation.B ) The Raw Material Used For The Implant Should Be Titaniumc ) Mis Screws Have To Be Cannulated, Which Designed To Work In Tandem With Expandable Retractor That Facilitates Screw Implantation In Spite Of Reduced Visualisation Within Narrower Working Channels. D ) The Placement Of The Rod In Miss Is Crucial As The Surgery Is Percutaneous. E ) The Rods Should Be Precontoured. , Bone Substitute A ) Bone Substitutes Should Be Made Up Of Combination Of Btcp ( 85% ) And Ha ( 15% ) Having Capability Of Re-Generating New Bone Twice As Fast As Hydroxyapatite. B ) It Should Also Have A Dual Mechanism Of Action.C ) It Should Be In Sterile Packing And One Unit Should Contain 10Cc. D ) It Should Be Available In The Form Of Block, Cylinder, Wedge, Granules, Strip, Paste. , Digital Kyphoplasty-Kit A ) Consists Of: Balloon Placements And Cement Delivery System, Biopsy Trocar / Canula Kyphoplasty Cement, Inflatable Balloon – 15Mm / 20Mm, Pressure Gauge Syringe. , Digital Vertebroplasty-Kita ) Consists Of: Cement Delivery System, Biopsy Trocar / Canula Vertebroplasty Cement , Inuse Bone Graft ( Small, Medium, Large ) , Sublaminar Titanium Cable System A ) The Cable Should Be Made Of Multiple Strands Of Titanium To Enable Better Grip Over Tissues. B ) The Individual Packaging Should Be Available In Double Cable And Single Cable Individual Sterilized Packaging.C ) It Should Be Malleable. D ) It Should With Stand Twisting And Knotting Without Loosing Its Tensile Strength. E ) It Should Have A Built In Crimp To Enable Fixation Without Having To Tie A Knot And Have Optimal Tension After Fixation. F ) It Should Be Of Medical Grade Titanium And Should Be Artifact Free On Mri And Ct. G ) Titanium Double Cable With Integral Crimp H ) Titanium Single Cable With Integral Crimp I ) Provisional Crimps – 2Nos J ) Cable Tensioner – 1Nos K ) Cable Cutter-1Nos L ) Graphic Sterlization Case , Shunt System: A. Omaya Reservoir ( Puding Type ) B. Ventriculo Peritoneal Shunt ( Equilent To Vp Shunt By Surgiwear / Hindustan Latex Pvt Ltd. ) I. Lowpressure Ii. Medium Pressure Iii. High Pressure C. Ventriculo Peritoneal Shunt Variable Adjustable Pressure With At Least 8-10 I. Variable Pressure Settings, Non Invasive, No Mandatory But Optional X Ray Ii. Confirmation Of Pressure Settings, Mri Compatible D. Theco-Peritoneal Shunt E. External Ventricular Drainage System F. External Lumbar Drainage System , Aneurysm Clips : A ) Sugita Type B ) Made Of Titanium Or Mri Compatible Material C ) Both Temporary And Permanent Type D ) Fenesterated / Non Fenestrated E ) In Various Shapes Straight / Up Curve / Downcurve / Bayonet Type / Right Angle Bent / 45 Angled / Lateral Bent F ) With Clip Applicators Availability For Both Permanent And Temporary Clips Of Variable Sizes At The Time Of Surgery , G ) Sizes Mini In Each Shape And Type Mentioned Above 5Mm , 6Mm , 7Mm , 8Mm , 9Mm , 10Mm , 12Mm , Disposable Items For Rfta Machine Compatible Withlnomed Made Model , I ) Patient Plate With Wire , Ii ) Rf Reusable Electrode 10 Cm With Wire , Iii ) Rf Disposable Cannula 10 Cm Long, 10Mm Tip, 22G , Iv ) Rf Disposable Cannula 10 Cm Long, 5 Mm Tip, 22G , V ) Rf Disposable Cannula 10 Cm Long, 10 Mm Tip, 20G , Vi ) Rf Disposable Cannula 10 Cm Long, 5 Mm Tip, 20G , Vii ) Rf Disposable Cannula 5 Cm Long, 4 Mm Tip, 22G , Viii ) Rf Disposable Cannula 15 Cm Long, 10 Tip, 20G , Ix ) Rf Reusable Electrode 15 Cm With Wire , X ) Rf Reusable Electrode 5 Cm With Wire , Disposable Items For Electric High Speed Drill Styker Made , 01. 5100060001 Perforator Bit , 02. 5820010010 Cutting Bur 1 Mm , 03. 5820010220 Cutting Bur 2 Mm , 04. 5820010230 Cutting Bur 3 Mm , 05. 5820010240 Cutting Bur 4 Mm , 06. 5820010250 Cutting Bur 5 Mm , 07. 5820010260 Cutting Bur 6 Mm , 08. 5820012010 Round Diamond Bur 1.0 Mm , 09. 5820012020 Round Diamond Bur 2.0 Mm , 10. 5820012030 Round Diamond Bur 3.0 Mm , 11. 5820012040 Round Diamond Bur 4.0 Mm , 12. 5820012050 Round Diamond Bur 5.0 Mm , 13. 5820012060 Round Diamond Bur 4.0 Mm , 14. 5407Fa2023 Fa2 2.3 Mm Tapered Router 16 Mm , 15. 5290075000 Core Essx / Hummer Irrigat Cas ( Pk Of 10 ) , 16. 5290640100 4.0 Mm 60 Deg. Agg Serr Blade ( Pk Of 5 ) , 17. 5290740200 4.0 Mm Convex Angled Aggressive ( Pk Of 5 ) , 18. 5290740100 4.0 Mm Angled Aggressive Blade ( Pk Of 5 ) , 19. 5290645000 4.0 Mm Aggressive Serrated ( Pk Of 5 ) , 20. 5290011000 4.0 Mm Aggressive Blade 11 Cm ( Pk Of 5 ) , 21. 5290440100 4.0 Mm 40 Deg. Agg Serr Blade , 22. Irrigation Cassette With Tubing Disposable , 23. Burr Perforator , Miscellaneous Items: A ) Dural Replacements / Substitute For Repair Of Dural Defects B ) Bone Cement Depuy Or Equivalent For Cranioplasty C ) Customized Peek Cranioplasty Impant For Better Reconstruction Of Craniectomy Defect D ) Fibrin Glue & Floseal ( As Per Specification Of Baxter / Releseal ) E ) 5 Amino Levulanic Acid Dye 20Ml / 50Ml F ) Percutaneous Tracheostomy Sets Of Variable Sizes With Griggs Forceps , G ) Indo Cyanine Green Dye 20 Ml , H ) Indo Cyanine Green Dye 50 Ml , I ) 5 Amino Levulanic Acid Dye 20 Ml , 5 Amino Levulanic Acid Dye 50 Ml , J ) Polyvinyle Alcohol Nasal Packing With Thread , K ) Sterile Powder Free And Latex Free Gloves 7.5 , Sterile Powder Free And Latex Free Gloves 8 , L ) Bipolar Cable : Compatible With Alan Made Cautery , Bipolar Cable : Compatible With Storz Endoscopy Cautery , M ) Bipolar Forceps Non Sticky Tip Bayonet / Straight : Compatible With Alan Made Cautery , Bipolar Forceps Non Sticky Tip Bayonet / Straight : Compatible With Storz Endoscopy Cautery , N ) Subcutaneous Ventriculo Peritoneal Shunt Passer ( Paediatric ) , O ) Subcutaneous Ventriculo Peritoneal Shund Passer ( Adult ) , P ) Disposable Microscope Cover For Pentero 900 , Q ) Autoclaveble Ot Shoes , R ) Antimicrobial / Iodofor Impregnated Drapes Of Various Sizes , Neuro Surgery Instruments Set , Cushing Dural Hook 140Mm , Gruenwald Forceps Bayonet Shape, 7 T.C. Tip - , Mayo Hegars Needle Holders 200Mm , Hegar Needle Holder Withgroove 20Cm , Inge Lamina Spreader Jaws Opento 1-1 / 4 Length 6 - , Ferris Smith I.V.D Ronguers Cd.Up180mm 3Mmx 10Mm , Ferris Smith I.V.D Ronguers Cd.Up180mm 4Mm X 10Mm , Brain Cannula8mm , Brain Cannula10mm , Mayos Scissors Cd. 160Mm , Ventricular Cannula 2 X 70Mm Dia. , - Do -, 2.5 X 70Mm Dia. , Gerald Dressing Forceps Bayonetplain 190Mm , Hudsons Brace , Yasargil Micro Scissorstraight 185Mm , Jacobson Micro Scissorcurved 185Mm , Potts-Yasargil Micro Scissorangled 45 Deg, 185Mm , Micro Suture Tying Forceps St.Tip0.3Mm X 150Mm , Micro Suture Tying Forceps Cd.Tip0.3Mm X 150Mm , Micro Suture Tying Forceps St.Tip0.5Mm X 180Mm , Micro Needle Holder With Catchst. 185Mm , Yasargil Ligature Guide & Carrier Ball Tipped Curved 185Mm , Yasargil Micro Raspatory Microdissector Angled 185Mm , Dandy Scalp Haemostatic Forcepscurved 140Mm , Cushing Dissecting Forceps Bayonetshape Plain 180Mm , Halsted Mosquito Artery Forceps Cd.125Mm , Adson Cerebeller Retractor Sharp, Angled 180Mm , Adsons Dissecting Forceps Plain125mm , Adsons Dissecting Forceps Toothed125mm , Adsons Dissecting Forceps Toothed150mm , Cushing Dissecting Forceps Bayonetshape Toothed 200Mm , Wullstien S / R Retractor3 X 3 Prongs Blunt 13Cm Sisco , Ruskin Bone Ronguers D / A Cd.4Mm X185mm , Penfield Dissector Doubleended 175Mm , Schimider Taylor Scissor16cm , Mallable Brain Spatula Narrow With Serrated 200Mm , Malleable Retractor Of Various Sizes , Disc Forceps In Various Sizes , Bone Punches ( Ronguers ) Of Various Sizes , Gillies Tissue Forceps 1X2 Teeth150mm , Micro Adsons Dissecting Forcepstoothed 180Mm , Yasargil Micro Scissorstraight 225Mm , Yasargil Micro Scissor Bayonetstraight 165Mm , Jacobson Micro Probe With Balltip ( Counter Presser ) 185Mm , Cloward Cervical Vertebra Spreader , Cloward Large Cervical Retractorset Of 10 Blades 255Mm , Mayo Hegar Needle Holder T / C Tip150mm , Toennis-Adson Scissors Tc Tipcd. 175Mm , Metzenbaum Scissors Tc Tip St200mm , Cottle Chisel 4Mm X 180Mm , Landolt Tumour Grasping Forcepsblunt Shaft 200Mm , Malleable Brain Spatulas, 8 , Caspar Longus Colli Muscledissector 175Mm , Farazier Dural Hook 5 , Suction Canula Set Of Four, No. 1, 2, 3, 4 , Scalpal Handle Bayonet Shape 210Mm 8.50 Inch , Cairns Neuro Scissors , Listonbone Cutting Forceps 275 Mm Curved On Flat , Hartman Crocodile Brain Biopsy Forceps 175Mm , ----------------------Do-------------------------------250 Mm , Adson Self Retaining Retractor Blunt 330Mm , Miskimon Cerebellar Retractor , Harvey Jackson Laminectomy Retractor Hined Arms Blade 1.5 Wide ;1.75 Deep ;Length 290Mm , Kilner Needle Holder Box Joint 0.4Mm ;5 Length Tc Jaws Gold Plated , Auto Clavable S.Steel Drums 15X12 , Auto Clavable S.S Tray With Lid For Microsurgical Ins. With Silicone Matt. , Auto Clavable S.Steel Tray With Lid 12X18 , Schlesinger Ivd Rongeur, Size :- 152 Mm Shaft :, Cup 2X10mm , Schlesinger Ivd Rongeur, Size :- 152 Mm Shaft:, Cup 3X10mm , Schlesinger Ivd Rongeur, Size :- 152 Mm Shaft :, Cup 4X10mm , Hardy Kerrision Punch , Size :- 1Mm, 40Degree Up’’ Length , Cervical Kerrision Thin Plate , Size :- 40º Degree Up, 2Mm, 7’’ Lengthgold Screw , Lumbar Kerrision Rongeur , Size :- 40º Degree Up, 3Mm, 8’’ Length , Lumbar Kerrison Rongerurhardy Style Handle Withball Spring 40º Up 8’’ Length , Stille Leur Rongeur Curved Bite, 5Mmlength 229Mm , Stille Leur Rongeur Curved Bite, 10 Mm, Length 216 Mm , Cervical Self Retainingretractor Set Length-254 Mm Opening- 144 Mm With Seven Pairsretractor Blade 25Mm To 55 Mm@ 5Mm Interval , Vertebral Body Spreader With Ratchet Lock Length – 127Mm , Mayo Hegar Needle Holder , Length – 7’’ Tc Inserts , Adson Dural Needle Holder Fenestrated Jaws , Length -181Mm , Arachnoid Knife 2Mm / 3 Mm / 4Mm , Fogarty’S Balloon Catheter For Endoscopic Third Ventriculostomy 4 Fr / 5 Fr , Long Artery Forceps , Cheatle Forceps , Tongue Depressor , Catspaw Retractor , Markham – Meyerding Hemilaminectomy Retractor Of Various Sizes , Mayo Table , Craniotomy Burr Perforator For Use With Hudson Brace , Yasargil Arachnoid Knife , Subcutaneous Ventriculo Peritoneal Shunt Passer ( Adult ) , Yasargil Biopsy Forcep , Toothed Dissecting Forceps , Wooden Handle Dissector , Titanium Made Neuro Surgery Instruments Set , 01. Micro – Scissor Of Various Sizes , 02. Micro Needle Holder Of Various Sizes , 03. Tissue / Tumor Grasping Forceps Of Various Tips And Sizes , 04. Microscopic Probe , 05. Microscopic Scoop , 06. Microscopic Dissector , 07. Microscopic Curette , 08. Microscopic Resparatory , 09. Microscopic Tumor Knife , 10. Microscopic Hooks , 11. Modular Suction Cannula , 12. Bipolar Forceps , 13. Instrumentorganization System Trays , 14. Microscopic Arachnoid Knife , Electrical Drill ( Manman ) Craniotome & Perforator Specification For Electrical Drill ( Manman ) Craniotome & Perforator , Craniotome Cutter Blade , Craniotome Hand Piece , Craniotome Cutter Hand Piece , Shaft For Craniotome , Reusable Perforator 10 / 12 / 14Mm Burr

Key Value

Document Fees
INR 2000 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

dk;Z dk uke %& fpfdRlky; ds U;wjksltZjh foHkkx esa U;wjksbEIykUV~l dh vkiwfrZ ckcr~A
Sl. No. Item Description
1Anterior Cervical Plating System (Variable Angle Screws System)a)        Single plate must provide the option of rigid, toggling and hybrid construct. b)       The angulations must be of 28 degree cephalad /caudal range with 8 degree of off set. c)        Locking mechanism of the screws must be one step locking should block the screws from coming out. d)       The thickness of plate must be 2.0mm OR less and width 16.5 mm e)       The core diameter of the screws must be 3mm with outer diameter being 4.0mm and 4.5mm. f)         All the screws must be colour coded and available in self tapping as well as self drilling options. g)        The plates must be available in all sizes.-
2I level
3II level
4III level
5Cervical Peek Cage a)       The cage must be radiolucent with sharp teeth inter body fusion cage system of implants and instruments designed for anterior cervical interbody fusion (ACIF) and should be compatible with anterior cervical plating system (ACP).b)       The cages must be Curved cages, which mimic the curvature of the healthy endplate. c)       The cages must be Wedge-shaped cages, which match the flattened degenerated end plate. d)       All implants must be 15mm wide and 12.5mm deep and are supplied sterile pre-packed. e)      The available implant heights must be -
6The available implant heights must be 5mm
7The available implant heights must be 6mm
8The available implant heights must be 7mm
9The available implant heights must be 8mm
10The available implant heights must be 9mm
11The available implant heights must be 10mm.
12Expandable Cervical Corpectomy cages a)       Expandable vertebral body replacements For Cervical & upper Thoracic (C3-T2) Spine b)       Should have continuous expansion system so that height can be achieved c)       Should have rapid & controlled in situ expansion d)       Should have locking clip to secure the expanded implant to prevent micro movements. e)       Should have foot print of 11.9 mm X 15.0 mm f)        Should achieve height from 17mm to 70mm & angle from 4.5 to7 degree g)      Should be made of medical grade titanium material
13Locking Cervical Cage With Plate a)       Expandable vertebral body replacements cage with in built cervical plate for fixation in situ with in the system for Cervical & upper Thoracic (C3-T2) Spine. b)       Should have continuous expansion system so that desirable height can be achieved c)       Should have rapid & controlled in situ expansion with plate providing the option of rigid, toggling and hybrid construct d)       Should be made of medical grade titanium materiale)       Locking mechanism of the plate screws must be one step locking which should block the screws from coming out.f)        All the screws must be colour coded and available in self tapping as well as self drilling options. g)       The core diameter of the screws must be 3mm with outer diameter being and. h)       The plates must be available in all sizes-
14g)       The core diameter of the screws must be 3mm with outer diameter being and. 4.0mm
154.5mm
16h)       The plates must be available in all sizes- I level
17II level
18III level
19Cervical Disc replacement a)       Superior and inferior implant plate made of cobalt-chromium molybdenum alloy according ISO 5832-12. b)       Plasma-sprayed titanium coating. c)       Inlay made of ultra-high molecular weight polyethylene(UHMWPE) d)       Ball and socket principal – Metal on polymer. e)       Modular anatomical design. f)        Optimal primary stability due to H keel anchorage of the a prosthesis in the vertebral body. g)       Anatomical foot print design for maximum endplate coverage.
20h)       Six different footprints available for optimal coverage of the vertebral end plate : M
21MD
22LD
23XL
24XLD
25i)         Three different heights (5, 6 and 7mm) allowing adjustments to the individual dimensions of the patient’s disc.5
26Three different heights (5, 6 and 7mm) allowing adjustments to the individual dimensions of the patient’s disc 6
27Three different heights (5, 6 and 7mm) allowing adjustments to the individual dimensions of the patient’s disc. 7
28Lumbar Disc Replacement a)       Superior and inferior implant plate made of cobalt-chromium molybdenum alloy. b)       Ball and socket principle- Metal on Polymer. c)       Inlay made of ultra-high molecular weight polyethylene (UHMWPE) d)       There must be Vacuum Plasma spray Coatinge)       There must be primary stability through central keel. f)        Angulations selection must be from:
29Superior Plate: 3 °, 6° and 11°
30Inferior plate: 0°, 3° and 8
31Combinations : 3°, 6°, 9°, 11°
32Posterior Cervical Fixation System(Lateral Mass Fixation System) a)       The system should have cancellous bone and cortex screws. b)       The system should have locking screws for angularly stable locking and fixation of the rod. c)       The system must have self tapping screws. d)       The system must have 3.5mm Ti Rod. e)       The system should have OC fusion option. f)        The system should offer hooks. g)       The system should have Cortical profile bone screws :3.5mm with 2mm increments. h)      The system should have Rod = 9mm. i)         The system should have Transverse connector: 60mm and 75 mm. j)         The system should have 3.5mm Ti Transverse Bar.k)       The system should have Occipital Plate/Rods.
33l)         The system should have Cancellous profile bone screws :           I.            3.5mm with 2mm increments.
34II.            4.0 mm with 2mm increments.
35m)       Shaft Screws should have 10mm unthreaded portion Rods : I. 3.0mm , 3.5mm Ti Rod.
36II. 3.5mm / 5.0mm Ti Rod.
37III. 3.5mm / 6.0mm Ti Rod.
38Mesh Cage for vertebral body replacement The mesh cage must be available in the following specifications and must come along with press fit end rings:
39a)    Mesh, round (for Cervical)    I.    10mm: heights 4-18mm
40II.     12mm: heights 4-88mm
41III.     15mm: heights 8-88mm
42b)    Corresponding press fit end rings, round    I.     Angles of 00 or 2.50 in 10mm diameter options.
43II.     Angles of 00 or 2.50 in 12mm diameter options.
44III.     Angles of 00 or 2.50 in 15mm diameter options.
45c)    Mesh, oblong (For thoracic and lumbar region) –    I.     Dimensions: 17X22mm, 22X28mm and 26X33mm – Heights: 6-88mm
46II.   End Rings, oblong Angles of 00 or 50for the corresponding dimensions; 17X22mm, 22X28mm and 26X33mm.
47CV Junction fixation System (occiput to C2) a)       The system should have medial and lateral plates of 50mm & 60mm, one & two hole clamps which must allow the medial and lateral rod placement, and should be able to give 15 degree of screw angulations b)       The system must have straight and pre contoured ‘3.5mm rods. c)       The system should have blunt 4.5mm occipital screws Qrid 5mm emergency screws with 4-18mm lengths.d)       The system should have screwdriver shaft stardrive T15, self holding, with cordan joint as well as straight, for Quick coupling. e)       The system must have the templates of occipital plates to avoid wrong plate selection. f)        The system should have simple locking mechanism of each screws. g)       The system should have tap for better screw purchase and 2mm torque limiting screw driver for final tightening. h)       Following components should be available in system :i)         Occipital plate (t or y shaped) j)         Transverse Connector
4850mm
4960mm
50one hole clamps
51two hole clamps
52CV Junction fixation System (C1 to C2) a)       The system should be versatile, must have set of 6 screws and two rods b)       The system must have straight and pre contoured ‘3.5mm rods. c)       Titanium made 3.5 mm diameter, polyaxial screw of different lengths from 12 mm to 36 mm length for posterior cervical fixation. d)       The system should have tap for better screw purchase and 2mm torque limiting screw driver for final tightening. e)       Joint spacer of various sizes made of titanium
53Zero profile anterior cervical interbody fusion devices a)       The implant should act as stand alone interbody fusion device for cervical spine with the benefits of both as interbody spacer and as anterior cervical plate. b)       The implant must be a combination of ‘end screw and spacer’ & where the spacermust automatically align when inserted. c)       The implant must have radio opaque marker for posterior visualization during imaging and teeth on superior and anterior surface for initial stability. d)      Spacer Component must be made of PEEK optima (polyetherketone). e)      The implant must have one step locking screw and screws should form a bone wedge with 40° 5° cranial/caudal angle with 2.5° medical lateral angle. f)       The screw must come with self tapping and self centering options with titanium alloy material (Ti-6AI-7NB) g)      Implant’s triobular thread cutting flutes should be self centering. h)      The implants must come in parallel lordotic and convex implants sets with heights varying from 5mm to 12mm with an increment of 1mm each. i)         The screws must come in 3.0mm diameter & must be colour coded by screw length varying from-
5412 mm
5514 mm
5616 mm
57Odontoid Screw a)      Screw should made up of Tianium Alloy (TAN). b)      Screw should be Cannulated. c)      Screw should be self-drilling and self tapping. d)      Screw should consist of 12mm short thread. e)      Screw should be of 3.5mm Ø. f)       Screw should be available in the length of 36mm to 50mm. g)      The whole system should thus enable the following-h)      Help in preservation of atlantoaxial mobility with lag screw compression technique. i)        With wire guiding ensures precise positioning of Implants & instruments.
58Top Loading Pedicle screw system a)       Top loading pedicle screw and rod system for the posterior stabilization of the lower back. b)       The pedicle screw system must have polyaxial as well as monoaxial head for case specific manipulation. c)       The polyaxial head should offer 25 degree of angulations about the axis of the screw.d)       The pedicle screw system must have dual core screws for rapid insertion and secure anchorage in both, cortical and cancellous bone. e)       The screws must be colour coded f)        Single step locking mechanism. g)       The option of achieving case specific lordotic and parallel compression with the same system. h)       Curved rods in 6mm diameter from length 70mm to 300mm. i)         Straight rod in 6mm diameter from 80mm to 150mm. j)         Monoaxial, Multiaxial and Reduction screws should be available. With provision of persuader for spondylo-listhesis reduction.
59k)       Screw dimensions should be-4.5mm
605.5mm
616.5mm
62l)         diameter LENGTH 30mm
6335mm
6440mm
6545mm
6650mm
67Trans Foraminal Lumbar Interbody Fusiona)       The cage must be radiolucent made up of PEEK – optima material with sharp teeth designed for Trans foraminal Lumbar Interbody Fusion (TLIF). b)       The cage must have rounded tapering edges allowing easy insertion thus minimizing injuries to end plates and neural structures.c)       The cage must have 3 titanium markers (Two lateral, one central) to indicate the cage position on x-ray.d)       The cage must have injection moulded roughened surface promoting bone integration and on growth.e)       The cages must have biconvex shape providing even distribution of compressive forces along the endplates thus stability. f)        The cage must have one broad graft hole and two lateral holes. g)       Implants must be available in two footprints sizes
6814 (g)-1 10x27mm
6914 (g)-211mm
7014 (g)-312mm
7114 (g)-4 13mm
7214 (g)-5 15mm
7314 (g)-6 17mm
74Posterior Lumbar Interbody Fusion a)  The system should be able to provide: -   Adequate stability       Restores disc heightRestores LordosisPreserves the integrity of the vertebral body endplates Provides an optimized fusion bed b)   It should be radiolucent interbody fusion system of implants and instruments for posterior Lumbar Interbody Fusion (PLIF). c)  Cage must be made of PEEK optima® material facilitating radiographic assessment of fusion. d)  Cage must have two x-ray markers integrated into the cages to enable easy visualization of their position postoperatively. e)  PEEK material used must contain no carbon fibres, thereby reducing the risk of systemic uptake and local inflammatory response. f)  Cages must be available in 6 heights in 2 mm increments, and should be supplied sterile pre-packed. g)  The optimal anatomical shape and supportive superior and inferior surface design of the cage should reduces the risk of subsidence into the adjacent vertebrae. h)  The cage should have perforated structure which must allows for bony ingrowth through the cage and the design must ensures optimal implant-to-endplate contact. i)  Cage must be designed for an optimal fit into the natural concavity between two adjacent vertebral bodies. j)  Cage must have teeth on the superior and inferior surfaces providing additional primary stability. k)  The cage must be injection moulded PEEK cage so that it has roughened surface, which is superior to a machined PEEK surface in that promotes bone integration and ongrowth.
75Anterior stabilization of thoracolumbar spine a)  The implant should provide anterior stabilization to thoracolumber spine. b) The implant should provide the plate and rod construct and be designed to be used along with either bone graft or with a vertebral body replacement. c)  The implant should come with instruments which are designed for use in open, minima-open or endoscopically assisted approaches. d)  The implants should come with telescopic mechanism with the facility of in situ compression and distraction. e) The implantsshould comein the following sizes : f) Height of the implant above bone without posterior locking screws should be 7.7mm and with posterior locking screws should be 9.0 mm and convergence of screws should be of 7.0°. g)  The posterior screws should be of 7.0 mm diameter, cannulated for use with k-wire, dual core and double lead. h) The implants should come with polyaxial bushings which allow an angulation of 15° for screw insertion tailored to the individual anatomical situation.
76i)  Mono-segmental:- 29-33 mm
7731-37mm
7835-45mm
7941-57mm
80j)         Bi-segmental :- 53-71mm
8166-86mm
82Expandable Thoracic and Lumber Corpectomy cages.a)       Expandable vertebral body replacements b)       For Lumber & Lower Thoracic (T5- L4) Spine c)       For mono, bi & trisegmental fusion d)       Should have rapid & controlled in situ expansion.e)       Should have ratchet system so that height can be achieved f)        Should have foot print of22 X 21 mm and 25 X 28 mm g)       Should achieve height from 20mm to 73mm & angle from -5°, 0°, 10°, 20°, -6°. h)       Should be in Titanium TAN alloy.
83Low Profile Neuro (Mini plates) a)       A Plating systems to offer Neuro surgeons a choice do rigid fixations of craniotomies and other cranial procedures which should be very low profile in nature and be a Complete system for a broad spectrum of cranial indications having following specifications technically : b)       A modular system having autoclavable module for instruments and implantsc)       All plates are should be 0.5mm thick and implants should be offered in various shapes for an optimal and appropriate choice in the procedure there should include basic plates, frame plates, adaption plates-available in multi holes, burr hole covers, burr hole covers for shunt and mesh plates in various dimensions (both 0.4mm & 0.6mm should be available). d)       Temporal & mastoid region should have dedicated plates for use. e)       Screw/plate profile should be not more than 0.6mm for minimum palpability.f)        Despite the minimum profile, the plate strength should be comparable to thicker cranial plates. g)       The screws should be designed for hard cranial bones and should have a plus Drive recess for excellent screw retention in the shaft. h)       The screws should have a flat head and should be easy to pick up with a self holding shaft. i)         The screws should have a selection self-drilling and self tapping types. j)         Screw lengths should be available in 3-6mm. k)       Emergency screws having different colour than regular screws. l)         The screw driver handles with hexagonal coupling. m)     Long (66mm) and short (42mm) shafts which should be self holding in nature and compatible with all screws in the system and also fit the handle instantly. n)       Holding instrument for plates must be a part of the instrumentstion. o)       A special cutter for strut & mesh plares to be provided in the system. p)       Appropriate 1.3mm drill bits of 4mm & 6mm depth having stops. q)       Appropriate Lable clips for the screws which should be replaceable.
84Burr Hole Cover Plate
85Cranial Fixation system for craniotomized bone flaps and bone fragments in neurosurgery (equivalent to craniofix)
86HA coated Multiaxial screws for osteoporotic spine fixation a)       (Implants compatible with vertebral column manipulation and vertebral body rotation rotation instrumentation)
87b)       Open ended Reverse thread Toploading Top Tightening fixed Angle screws with breako off type of plug (assorted size)- 4.5mm
885.5mm
896.5 mm
90c)       Open ended Reverse thread Toploading Top Tightening Multiaxial screws (assorted size)- 4.5mm
915.5mm
926.5 mm
93d)       Reduction Screws,4.5mm
945.5mm
956.5 mm
967.5 mm
97e)       Break off plugs f)        Reduction Break off plugs g)       Transverse connectors (assorted size) h)       Staples -13mm
9815mm
9917mm
100i)         Double Rod Staplerostral and Caudal j)         Domino’s axial connectors k)       Reverse thread Top loading Top Tighteneing pediatric Hooks-upper thoracic, laminar, Pedicular small and medium, right/left offset, Angled hooks. 21mm
10123mm
10225mm
103Percutaneous Pedicular screw Systemsfor multilevel fixation (For MIS system) a)       The minimal invasive pedical screw system must be offered that is suitable for offset 3 levels of fixation.b)       The raw material used for the implant should be Titaniumc)       MIS screws have to be cannulated,which designed to work in tandem with expandable retractor that facilitates screw implantation in spite of reduced visualisation within narrower working channels. d)       The placement of the rod in MISS is crucial as the surgery is Percutaneous. e)       The Rods should be precontoured.
104Bone Substitute a)       Bone Substitutes should be made up of combination of BTCP (85%) and HA(15%) having capability of re-generating new bone twice as fast as hydroxyapatite. b)       It should also have a dual mechanism of action.c)       It should be in sterile packing and one unit should contain 10cc. d)       It should be available in the form of Block, Cylinder, Wedge, Granules, Strip, Paste.
105Digital kyphoplasty-Kit a)       Consists of: Balloon placements and cement delivery system, Biopsy trocar/canula kyphoplasty cement, Inflatable balloon – 15mm/20mm, Pressure gauge syringe.
106Digital Vertebroplasty-Kita)       Consists of: cement delivery system, Biopsy trocar/canula vertebroplasty cement
107INUSE BONE GRAFT (small, medium, large)
108SUBLAMINAR TITANIUM CABLE SYSTEM a)       The Cable should be made of multiple strands of titanium to enable better grip over tissues. b)       The individual packaging should be available in double cable and Single Cable individual sterilized packaging.c)       It should be malleable. d)       It should with stand twisting and knotting without loosing its tensile strength. e)       It should have a built in crimp to enable fixation without having to tie a knot and have optimal tension after fixation. f)        It should be of Medical Grade Titanium and should be artifact free on MRI and CT. g)       Titanium double cable with integral crimp h)       Titanium single cable with integral crimp i)         Provisional crimps – 2Nos j)         Cable Tensioner – 1Nos k)       Cable Cutter-1Nos l)         Graphic Sterlization case
109SHUNT SYSTEM: a.        Omaya Reservoir (Puding type) b.       Ventriculo Peritoneal Shunt (equilent to VP shunt by Surgiwear/Hindustan Latex Pvt Ltd.) I.         Lowpressure II.        Medium pressure III.       High pressure c.        Ventriculo peritoneal shunt variable adjustable pressure with at least 8-10 I.        variable pressure settings, non invasive, no mandatory but optional x ray II.        confirmation of pressure settings, MRI compatible d.       Theco-peritoneal shunt e.       External Ventricular drainage system f.         External Lumbar Drainage system
110Aneurysm Clips : a)       Sugita type b)       Made of titanium or MRI compatible material c)       Both temporary and permanent type d)       Fenesterated/ non fenestrated e)       In various shapes straight/ up curve/downcurve/bayonet type/ right angle bent/ 45 angled/ lateral bent f)        With clip applicators availability for both permanent and temporary clips of variable sizes at the time of surgery
111g)       Sizes mini in each shape and type mentioned above 5mm
1126mm
1137mm
1148mm
1159mm
11610mm
11712mm
118Disposable items for RFTA Machine compatible withlnomed made model
119i)Patient plate with wire
120ii)RF Reusable electrode 10 cm with wire
121iii) RF Disposable Cannula 10 cm long, 10mm tip, 22G
122iv)RF Disposable Cannula 10 cm long, 5 mm tip, 22G
123v)RF Disposable Cannula 10 cm long, 10 mm tip, 20G
124vi)RF Disposable Cannula 10 cm long, 5 mm tip, 20G
125vii)RF Disposable Cannula 5 cm long, 4 mm tip, 22G
126viii) RF Disposable Cannula 15 cm long, 10 tip, 20G
127ix)RF Reusable Electrode 15 cm with wire
128x)RF Reusable electrode 5 cm with wire
129Disposable items for Electric high speed drill Styker made
13001.    5100060001 perforator bit
13102.    5820010010 cutting bur 1 mm
13203.    5820010220 cutting bur 2 mm
13304.    5820010230 cutting bur 3 mm
13405.    5820010240 cutting bur 4 mm
13506.    5820010250 cutting bur 5 mm
13607.    5820010260 cutting bur 6 mm
13708.    5820012010 round diamond bur 1.0 mm
13809.    5820012020 round diamond bur 2.0 mm
13910.    5820012030 round diamond bur 3.0 mm
14011.    5820012040 round diamond bur 4.0 mm
14112.    5820012050 round diamond bur 5.0 mm
14213.    5820012060 round diamond bur 4.0 mm
14314.    5407FA2023 FA2 2.3 MM TAPERED ROUTER 16 MM
14415.    5290075000 CORE ESSX/HUMMER IRRIGAT CAS (Pk of 10)
14516.    5290640100 4.0 mm 60 DEG. AGG SERR BLADE (Pk of 5)
14617.    5290740200 4.0 mm Convex angled aggressive (Pk of 5)
14718.    5290740100 4.0 mm angled aggressive blade (Pk of 5)
14819.    5290645000 4.0 mm aggressive serrated (Pk of 5)
14920.    5290011000 4.0 mm aggressive blade 11 cm (Pk of 5)
15021.    5290440100 4.0 mm 40 Deg. Agg serr blade
15122.    Irrigation cassette with tubing disposable
15223. Burr perforator
153Miscellaneous Items: a)      Dural replacements/substitute for repair of dural defects b)      Bone cement depuy or equivalent for cranioplasty c)      Customized peek cranioplasty impant for better reconstruction of craniectomy defect d)      Fibrin glue & floseal (as per specification of baxter/releseal) e)       5 amino levulanic acid dye 20ml/50ml f)        Percutaneous tracheostomy sets of variable sizes with griggs forceps
154g) Indo cyanine green dye 20 ml
155h) Indo cyanine green dye 50 ml
156i) 5 amino levulanic acid dye 20 ml
1575 amino levulanic acid dye 50 ml
158j) Polyvinyle alcohol nasal packing with thread
159k) Sterile powder free and latex free gloves 7.5
160Sterile powder free and latex free gloves 8
161l) Bipolar cable : Compatible with alan made cautery
162Bipolar cable : Compatible with storz endoscopy cautery
163m) Bipolar forceps non sticky tip bayonet/straight : Compatible with alan made cautery
164Bipolar forceps non sticky tip bayonet/straight : Compatible with storz endoscopy cautery
165n) Subcutaneous ventriculo peritoneal shunt passer (paediatric)
166o) Subcutaneous ventriculo peritoneal shund passer (adult)
167p)Disposable microscope cover for pentero 900
168q)Autoclaveble ot shoes
169r)Antimicrobial/iodofor impregnated drapes of various sizes
170NEURO SURGERY INSTRUMENTS SET
171CUSHING DURAL HOOK 140mm
172GRUENWALD FORCEPS BAYONET SHAPE,7" T.C. TIP -
173MAYO HEGARS NEEDLE HOLDERS 200mm
174HEGAR NEEDLE HOLDER WITHGROOVE 20CM
175INGE LAMINA SPREADER JAWS OPENTO 1-1/4" LENGTH 6" -
176FERRIS SMITH I.V.D RONGUERS CD.UP180mm 3mmx 10mm
177FERRIS SMITH I.V.D RONGUERS CD.UP180mm 4mm x 10mm
178BRAIN CANNULA8MM
179BRAIN CANNULA10MM
180MAYOS SCISSORS CD. 160mm
181VENTRICULAR CANNULA 2 X 70MM DIA.
182- DO -, 2.5 X 70MM DIA.
183GERALD DRESSING FORCEPS BAYONETPLAIN 190mm
184HUDSONS BRACE
185YASARGIL MICRO SCISSORSTRAIGHT 185mm
186JACOBSON MICRO SCISSORCURVED 185mm
187POTTS-YASARGIL MICRO SCISSORANGLED 45 DEG, 185mm
188MICRO SUTURE TYING FORCEPS ST.TIP0.3mm x 150mm
189MICRO SUTURE TYING FORCEPS CD.TIP0.3mm x 150mm
190MICRO SUTURE TYING FORCEPS ST.TIP0.5mm x 180mm
191MICRO NEEDLE HOLDER WITH CATCHST. 185mm
192YASARGIL LIGATURE GUIDE & CARRIER BALL TIPPED CURVED 185MM
193YASARGIL MICRO RASPATORY MICRODISSECTOR ANGLED 185mm
194DANDY SCALP HAEMOSTATIC FORCEPSCURVED 140mm
195CUSHING DISSECTING FORCEPS BAYONETSHAPE PLAIN 180mm
196HALSTED MOSQUITO ARTERY FORCEPS CD.125mm
197ADSON CEREBELLER RETRACTOR SHARP,ANGLED 180mm
198ADSONS DISSECTING FORCEPS PLAIN125mm
199ADSONS DISSECTING FORCEPS TOOTHED125mm
200ADSONS DISSECTING FORCEPS TOOTHED150mm
201CUSHING DISSECTING FORCEPS BAYONETSHAPE TOOTHED 200mm
202WULLSTIEN S/R RETRACTOR3 X 3 PRONGS BLUNT 13CM SISCO
203RUSKIN BONE RONGUERS D/A CD.4mm x185mm
204PENFIELD DISSECTOR DOUBLEENDED 175mm
205SCHIMIDER TAYLOR SCISSOR16CM
206MALLABLE BRAIN SPATULA NARROW WITH SERRATED 200mm
207MALLEABLE RETRACTOR of various sizes
208Disc Forceps in various sizes
209Bone Punches (Ronguers) of various sizes
210GILLIES TISSUE FORCEPS 1x2 TEETH150mm
211MICRO ADSONS DISSECTING FORCEPSTOOTHED 180mm
212YASARGIL MICRO SCISSORSTRAIGHT 225mm
213YASARGIL MICRO SCISSOR BAYONETSTRAIGHT 165mm
214JACOBSON MICRO PROBE WITH BALLTIP (COUNTER PRESSER) 185mm
215CLOWARD CERVICAL VERTEBRA SPREADER
216CLOWARD LARGE CERVICAL RETRACTORSET OF 10 BLADES 255mm
217MAYO HEGAR NEEDLE HOLDER T/C TIP150MM
218TOENNIS-ADSON SCISSORS TC TIPCD. 175MM
219METZENBAUM SCISSORS TC TIP ST200mm
220COTTLE CHISEL 4mm x 180mm
221LANDOLT TUMOUR GRASPING FORCEPSBLUNT SHAFT 200mm
222MALLEABLE BRAIN SPATULAS, 8"
223CASPAR LONGUS COLLI MUSCLEDISSECTOR 175MM
224FARAZIER DURAL HOOK 5"
225Suction canula set of four, No. 1,2,3,4
226Scalpal handle bayonet shape 210mm 8.50 inch
227Cairns neuro scissors
228ListonBone cutting Forceps 275 mm curved on flat
229Hartman crocodile brain biopsy forceps 175mm
230----------------------do-------------------------------250 mm
231Adson self retaining retractor blunt 330mm
232Miskimon cerebellar retractor
233Harvey jackson laminectomy retractor hined arms blade 1.5" wide ;1.75" deep ;Length 290mm
234Kilner Needle Holder Box Joint 0.4mm ;5" length TC jaws Gold plated
235Auto clavable s.steel drum"s 15"x12"
236Auto clavable s.s tray with LID for microsurgical ins. with Silicone matt.
237Auto clavable s.steel tray with LID 12"x18"
238Schlesinger IVD Rongeur,Size :- 152 mm shaft :,cup 2x10mm
239Schlesinger IVD Rongeur, Size :- 152 mm shaft:, cup 3x10mm
240Schlesinger IVD Rongeur, Size :- 152 mm shaft :,cup 4x10mm
241Hardy kerrision punch , Size :- 1mm, 40degree up’’ Length
242Cervical kerrision thin plate , Size :- 40º degree up, 2mm, 7’’ lengthGold screw
243Lumbar kerrision Rongeur , Size :- 40º degree up, 3mm, 8’’ Length
244Lumbar Kerrison RongerurHardy style Handle withBall spring 40º up 8’’ Length
245Stille Leur Rongeur Curved Bite, 5mmLength 229mm
246Stille Leur Rongeur curved Bite, 10 mm, Length 216 mm
247Cervical Self RetainingRetractor set Length-254 mm Opening- 144 mm With Seven PairsRetractor Blade 25mm to 55 mm@ 5mm Interval
248Vertebral body spreader with ratchet lock length – 127mm
249Mayo Hegar needle holder , length – 7’’ TC Inserts
250Adson dural needle holder fenestrated jaws , length -181mm
251Arachnoid Knife 2mm / 3 mm / 4mm
252Fogarty’s balloon catheter for endoscopic third ventriculostomy 4 Fr/ 5 Fr
253Long artery forceps
254Cheatle forceps
255Tongue depressor
256Catspaw retractor
257Markham – meyerding hemilaminectomy retractor of various sizes
258Mayo table
259Craniotomy burr perforator for use with Hudson brace
260Yasargil arachnoid knife
261Subcutaneous ventriculo peritoneal shunt passer (adult)
262Yasargil biopsy forcep
263Toothed dissecting forceps
264Wooden handle dissector
265Titanium made Neuro Surgery Instruments Set
26601. micro – scissor of various sizes
26702. micro needle holder of various sizes
26803. tissue/tumor grasping forceps of various tips and sizes
26904. microscopic probe
27005. microscopic scoop
27106. microscopic dissector
27207. microscopic curette
27308. microscopic resparatory
27409. microscopic tumor knife
27510. microscopic hooks
27611. modular suction cannula
27712. bipolar forceps
27813. instrumentorganization system trays
27914. microscopic arachnoid knife
280Electrical drill (manman) craniotome & perforator Specification for Electrical Drill (MANMAN)Craniotome & Perforator
281Craniotome cutter blade
282Craniotome hand piece
283Craniotome cutter hand piece
284Shaft for craniotome
285Reusable perforator 10/12/14mm burr
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail