Tender For Repair And Maint Of Window/Split Type Ac And Other Summer Appliances At Morar Cantt Under Ge Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair And Maint Of Window/Split Type Ac And Other Summer Appliances At Morar Cantt Under Ge Gwalior. Submission Date for this Tender is 28-02-2024. Air Conditioner Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41994960
Corrigendum : Tender For Repair And Maint Of Window/Split Type Ac And Other Summer Appliances At Morar Cantt Under Ge Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
28-02-2024

Tender Details

Repair And Maint Of Window/Split Type Ac And Other Summer Appliances At Morar Cantt Under Ge Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINT OF WINDOW/SPLIT TYPE AC AND OTHER SUMMER APPLIANCES AT MORAR CANTT UNDER GE GWALIOR
Sl. No. Item Description
1Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from window type AC and S&F New compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed.
2All as per Seritem No 1 above but compressorsuitable for window AC ofcapacity2.0 Ton complete all as specified and directed.
3Dismantling and taking out the existing old unserviceable compressor hermetically/rotarysealed unit of any make from split type AC and S&F New compressor suitable forSplitAC of capacity 1.5 Ton complete all as specified and directed.
4All as per Srlitem No.3 here in beforebut compressorsuitable for Split AC ofcapacity2.0 Ton complete all as specified and directed.
5M&Lfor testing leakage in systemSplitWindow type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the systemcomplete all as specified and directed.
6All as per Ser item No 5 above but Air conditioner of 2 to 3 ton capacitycomplete all as specified and directed.
7M&L for servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed. Note:- Item Serial No. 1.00 to 7.00(i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed. (ii)Spare parts alongwith Refrigerant gas shall be measured and paid separately there rate above Rs. 100/-
8The following items supply only :-
9Starting capacitor of capacity 80/100 MFD
10Starting capacitor of capacity 100/120 MFD
11Condenser capacity of5/6 MFD
12Condenser capacity of10 MFD
13Condenser capacity of36 MFD
14Condenser capacity of45 MFD
15Condenser capacity of50 MFD
16Condenser capacity of55 MFD
17Heating Coil suitable for 1.5 Ton Capacity Window AC
18Heating Coil suitable for 2.0Ton Capacity Window AC
19Heating Coil suitable for 1.5 Ton Capacity Split AC
20Heating Coil suitable for 2.0 Ton Capacity Split AC
21Cooling Coil suitable for 1.5 Ton Capacity Window AC
22Cooling Coil suitable for 2.0Ton Capacity Window AC
23Cooling Coil suitable for 1.5 Ton Capacity Split AC
24Cooling Coil suitable for 2.0 Ton Capacity Split AC
25Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner
26Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner
27Swing motor suitable for 1.5 Ton Capacity Split type Air Conditioner
28Swing motor suitable for 2.0 Ton Capacity Split type Air Conditioner
29Over load relay suitable for 1.5/2.0 Ton Window type AC
30Over load relay suitable for 1.5/2.0 Ton Split type AC
31Electric blower motor suitable for 1.5 Ton Capacity Window type AC
32Electric blower motor suitable for 2.0 Ton Capacity Window type AC
33Electric blower motor suitable for1.5 Ton Split AC (Evaporator/Condenser)
34Electric blower motor suitable for2.0 Ton Split AC (Evaporator/Condenser)
35Blower motor fan blade suitable for 1.5/2.0 Windowtype AC
36Blower motor fan blade suitable for 1.5/2.0 Split type AC
37Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC
38Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC
39Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC
40Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC
41Air Filter Suitable for1.5/2.0 Ton Capacity Window/Split type Air conditioner
42Capillary tube length as per existing size suitable for 1.5/2.0 Ton Capacity Air conditioner
43PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC
44PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 split type capacity Air Conditioner
45Repair of PCB of all type of AC.
46Metal top with bottomsuitable for 16 Amps Capacity1.5/2.0/3.0 Ton Capacity Air conditionerMake:Anchor/Havells/Philips/polycab and as per site requirement.
47Refrigerant gas R22/R-32 for topping up.
48Refrigerant gas R 134(a) for topping up.
49Refrigerant gas R 410(a) for topping up.
50M&L for replacement of damagedInsulation in white colour with water proof of size 1/4&3/8for Split AC complete as per existing sitecomplete all as specified and directed.
51M&L for replacement of damaged Insulation in white colour with water proofof size 1/2 & 5/8for Split AC complete as per existing sitecomplete all as specified and directed.
52M&L for replacement of Rubber bush suitable for 1.5/2.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed.
53M&L in servicing of inverter AC of capacity 1.5 Ton with pressure cleaning complete all as specified and directed.
54M&L for replacement of Copper Tube of size 1/4suitable for any type and any capacity Air conditionercomplete all as specified and directed.
55M&L for replacement of Copper Tube of size 3/8 and 5/8 suitable for any type and any capacity Air conditionercomplete all as specified and directed.
56Taking out and shifting new locationand refixingboth indoor and outdoor unit ofsplit type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0/3.0 Tonin wall with rowl plugs including making holes for inlet /outlet in the wallwith condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed.
57S&F bracket for fixing of AC"s complete all as specified and directed.
58M&L for repairs to walk in cooler 1.5 Ton andrepair/replacement the compressor, filter including gas charging and general service complete all as specified and directed.
59S&F in repair of complete indoor unit of window/Split AC of capacity 1.5 Ton complete all as specified and directed.
60S&F in repair of complete outdoor unit of window/Split AC 1.5 Ton complete all as specified and directed.
61S&F in repair of complete indoor unit of window/Split AC of capacity 2 Ton complete all as specified and directed.
62S&F in repair of complete outdoor unit of window/Split AC 2 Ton complete all as specified and directed.
63S&F in repair of complete inverter type indoor unit ofSplit AC 1.5 Ton complete all as specified and directed.
64S&F in repair of complete inverter type outdoor unit ofSplit AC 1.5 Ton complete all as specified and directed.
65Dismantling and taking out the existing old unserviceable compressor any make from invertor type split AC and S&F New compressor suitable for inverter type Split AC of capacity 1.5 Ton complete all as specified and directed.
66PCB Circuit suitable forinverter type Split AC of capacity 1.5 Ton complete all as specified and directed.
67S&F In Repair Air Conditioner Outdoor Valve with size of 1/2 Inch L type (13mm) for 1.5 Ton complete all as specified and directed.
68S&F In Repair Air Conditioner Outdoor Valve with size of1/4 Inch L type(13mm) for 1.5 Ton complete all as specified and directed.
69S&F In Repair Air Conditioner Outdoor Valve with size of 1/4 Inch L type (13mm) for 2 Ton complete all as specified and directed.
70S&F In Repair Air Conditioner Outdoor Valve with size of 5/8Inch L type(13mm) for 1.5 Ton complete all as specified and directed.
71S&F in Repair Copper wire with size of 2.5 Sqmm with 3 Core complete all as specified and directed.
72S&F in Repair Copper wire with size of 2.5 Sqmm with 4 Core complete all as specified and directed.
73Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F newcompressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I,suitable for Water cooler of cooling capacity 40/80 ltrs/hrs complete all as specified and directed.
74All as per Ser item No 32 abovebut compressorsuitable for Water Cooler of cooling capacity 150 ltrs/hrs complete all as specified and directed..
75M&L for carry out through check up of the unserviceable watercooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed.
76The following items supply only :-
77Blower fan motor SP,230V, 50 Hz suitable for 40/80, 60/120 capacitywater cooleras per existng sample complete all as specified and directed.
78All as per Ser item No 35.01 above but suitable for 150/180 or equivalent water cooleras per existng sample complete all as specified and directed.
79Capacitor for condenser motor suitable for any capacity, size complete
80Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
81Thermostat switch with knobsuitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
82PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia .
83Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity.
84M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed.
85M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed.
86All as per Ser item No 37.00 above but compressorsuitable for refrigerator capacity of 280 to 320 Ltrs complete all as specified and directed..
87The following items supply only :-
88Freezer suitable for165 to 200 ltrs capacity Refrigerator
89Freezer door suitable for 280 to 310 Ltrs capacity Refigerator
90Relay current typeand over load protector suitable for compressor complete.
91Thermostat auto defrost type suitable for any make and any capacity Refrigerator single door.
92Thermostat auto defrost type suitable for any make and any capacity Refrigerator doubledoor.
93Air Filter suitable for for any make and any capacity Refrigerator
94S&F suitable timer for any capacity.
95Electric blower motor suitable for 300 ltr refrigerater inverter type.
96PCB Circuit suitable for 300 ltr refrigerater inverter type.
97Heating sensor suitable for 300 ltr regrigerater inverter type
98Thermostate suitable for 300 ltr regrigerater inverter type
99Compressorsuitable for 300 ltr regrigerater inverter type
100Refrigerant gas R-600/R-290 in 150gm Canfor topping up for regrigerater inverter type
101M&Lfor testing the leakage in system by charging Nitrogen Gas up to 300 PSI.Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed.
102M&L carry out through check up the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc completeNote:- petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed.
103Dismantling and taking out the existing old unsv compressor sealed unit from Deep freezer and S&F newcompressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I,suitable for Water cooler of cooling capacity 310/320 ltrs/hrs and complete all as specified and directed.
104The following items supply only :-
105Relay current type and over load protector suitable for compressor .
106Thermostat auto defrost type suitable for any make and any capacity Deep Freezer
107Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complte
108Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity
109Starting relay with overload suitable for310/320 ltrs capacity Deep freezer
110Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer.
111Labour only for charging refrigerent gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and splittype Air conditioner after duly rectifying leakagesby welding/brazing and testng by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas to be measured and paid separately under relabent items of this schedule
112Dismantling and taking out the existing old unsv fan motor with blade including mounting brackets from Desert coolers and S&F new3 speed fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable forD/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed.
113Taking out burnt winding wire from cooler(Which req rewinding) Motor capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable forD/cooler of capacity 4000/5000/6000 Cum per hrs,single phase,Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & throughly cleaning all the components of Motar, oiling,greesing,replacement of rusted/unsv nuts,bolt,machine screws,shaft etc as required reassembling the Motar to Desert Cooler ,testing complete & Transporting back to MES Yard complete all as specified and directed. Note : (i) Testing should be done to repair Desert coolerminimum 24 Hrs continues running in MES store yard before fixing at site complete.
114The following items supply only :-
115Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr.
116Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size
117Capacitor for 2.5/4MFD
118Capacitor for 5/6 MFD.
119Front panel repair of dimension as per existing size suitable for desert coolerof capacity 4000/5000/6000 Cum per hrs
120PVC Flexible hose suitable for desert coolercooling system
121PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample
122Selector switch as per existing model and size
123Bolt, nut with washers as per sample
124PVC Connector i.e (Elbow, Tee,3 way etc)
1255 Amp Switch.
1265 Amp Plug Top.
127Monoplate with 5 Amp switch.
128S&F top portion/cover of the desert cooler of the existing size.
129S&F flexible wire of 2 core with size of 1.5 Sqmm complete.
130Taking down the evaporative type desert coolers of Capacity upto 5000 Cum/hr by disconnecting all the electrical connections cleaning all the components by removing the side panels and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panel and reconnecting with electrical connections and writing the MES No complete all as specified and directed.
131S&F leak prof desert cooler tank of size 29" x 14" made of 20 guage GI sheet complete all as specified and directed.
132Complete Repairing/Servicing/Testing of Stabilizer with capacity of 2 KVA complete all as specified and directed.
133Complete Repairing/Servicing/Testing of Stabilizer with capacity of3 KVAcomplete all as specified and directed.
134Complete Repairing/Servicing/Testing of Stabilizer with capacity of4 KVAcomplete all as specified and directed.
135Complete Repairing/Servicing/Testing of Stabilizer with capacity of5 KVAcomplete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail