Tender For Repair Replacement Of Winter And Summer Cooling Appliances And Associated Works At Air Force Station Amritsar, amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair Replacement Of Winter And Summer Cooling Appliances And Associated Works At Air Force Station Amritsar. Submission Date for this Tender is 28-02-2024. Air Conditioner Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41993218
Corrigendum : Tender For Repair Replacement Of Winter And Summer Cooling Appliances And Associated Works At Air Force Station Amritsar
Open Tender
Indian
Punjab
amritsar
28-02-2024

Tender Details

Repair Replacement Of Winter And Summer Cooling Appliances And Associated Works At Air Force Station Amritsar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
INR 8 Lakhs /-

BOQ Items

Name of Work :REPAIR / REPLACEMENT OF WINTER & SUMMER COOLING APPLIANCES AND ASSOCIATED WORKS AT AIR FORCE STATION AMRITSAR
Sl. No. Item Description
1Summer Cooling Appliances
2Servicing cleaning of window type room air conditioner 1.5 Ton capacity at site, cleaning of equipment with blower for removing dust, checking the complete wiring, running capacitor, staring relay, overload relay, thermostat switches condenser motor, blower/condensor fan rectification of fault, connecting and testing the same on load complete all as specified and directed. Note: Replacement of spares parts and filling of refrigeration gas shall be measured and paid separately under respective item.
3Servicing cleaning of split type air conditioner 1.5Ton/2 Ton capacity at site, cleaning of equipment with blower for removing dust, checking thecomplete wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified and directed. Note: Replacement of spares parts and filling of refrigeration gas shall be measured and paid separately under respective item.
4Servicing of water cooler of any capacity at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condenser motor, blower fan, rectification of fault replacement of spare and fillingof gas as on required basis, connecting & testing on load for performance all as specified and directed by Engineer-In-Charge Note: Replacement of spares parts and filling of refrigeration gas shall be measured and paid separately under respective item.
5Disconnecting, cutting and taking out unserviceable sealed unit compressor of window/split type air conditioner 1.5 ton capacity anymake & model and supply and fixing in replacement of compressor of same make as exiting of window/split type air conditioner 1.5 ton capacity type soldering, welding, brazing as required including filling of refrigerant gas, making electric & mechanical connections and water connection, installations of the same at site and testing on load, completeall as specified and directed by the Engr-in-Charge.
6Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type and supply and fixing in replacement of compressor of same capacity for water cooler storage type soldering, welding, brazing as required including filling of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of the same at site and testing on load completeall as specified and directed by the Engr-in-Charge.
7Disconnecting, cutting and taking out unserviceable sealed unit compressor of Refrigerator and supply and fixing in replacement of compressor of same make for Refrigerator of any capacitysoldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load completeall as specified and directed by the Engr-in-Charge.
8Supply and fix in replacement of, starting relay for 1.5 Ton window/split type AC including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge
9Supply and fixing in replacement, of thermostat switch of temperature range of 18°C to 30°C suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
10Supply and fix in replacement blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for window type room air conditioner 1.5 Ton capacity of existing make and size including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge
11Supply and fix in replacement blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for split type room air conditioner 1.5 Ton capacity of existing make and size including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge
12Cutting, disconnecting & taking out the condensing unit of window type room air conditioner 1.5 Ton capacity and S&F in replacement new condensing unit of appropriate size and model including welding brazing etc and testing on load complete all as specified and directed by Engineer-in-Charge
13Supply and fixing in replacement electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
14Supply and fixing, in replacement, starting capacitor suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
15Supply and fix, in replacement of air filter suitable for window/Split type AC 1.5 Ton capacity complete all as per sample and directed by Engineer-in-Charge .
16Supply and fixing, in replacement, of running capacitor suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
17Supply and fix, in replacement starting relay for Refrigerator of existing HP including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge
18Supply and fix, in replacement starting relay for Water Cooler including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge
19Supply and fix, in replacementthermostatic switches for any capacity for water cooler including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge.
20Supply and fix, in replacement Float valve with PVC float ball complete with screwed for iron pipe 15 mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge
21Supply and fix, in replacementPush cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler including dismantling the old unserviceable push cock complete all as specified and directed by Engineer-in-Charge.
22Supply and fix, in replacement Condensing coil for water cooler as existing make & model including dismantling the old unserviceable coil, complete all as specified and directed.
23S&F in replacement of blower motor of water cooler of same capacity at site, and testing on load complete all as specified and directed by Engineer-in-Charge
24Supply and filling of Refrigeration gas R-134/R-22/F-22 (Mefron/Refron) in returnable cylinder at site, complete all as specified and directed by Engineer-in-Charge .
25Material and labour for shifting outdoor / indoor unit split type and window type AC of any capacity from existing position to other location including civil work, copper pipe, PVC pipe and other material requirement at site, complete with making good disturbed surface of wall by providing brickwork, plastering colour so as to match withthe colour of existing wall and necessary arrangement for fixing of AC, complete all as specified and directed.
26Supply and fix, in replacement Automatic voltage stabilizer single phase 50 Hz 5 KVA capacity complete with voltage meter, time delay relay & auto cut off in the event of low/high voltage and all as per the following parameters fixed in replacement complete all as directed. (i)Incoming voltage 140 V to 200 V (ii)Stabilized voltage 230 +- 5%
27Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparations surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the plastic part of tullu pump and cooler body and oiling the pump & motor complete all as specified and directed by Engineer-in-Charge .
28Supply and fix, in replacementFan motor 1/5 HP, 230V, single phasefor desert cooler including dismantling the old u/s fan motor complete all as directed.
29Supply and fix, in replacement Pump motor 1/26 HP (Tullu pump) 230 volts, single phase,for desert cooler including dismantling the old unserviceable pump motorcomplete all as specified and directed by Engineer-in-Charge
30Supply and fix, Wood wool pad set suitable for desert cooler heavy duty including dismantling the old unserviceable wood wool pad set complete all as directed by Engineer-in-Charge
31Collectingu/s (burnt) ceiling fan with blade of any make 1200 mm / 1400 mm sweep from E/M yard , transporting to local workshop and back , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewindingwith new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing, screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running, and refixing the ceiling fan on their respective location (loc of the same received from respective section through complaint slip ) complete all as directed by Engr in charge Note:Bush, bearing, capacitor, andsockets shall be measured and paid for separately as supply only but Collecting & fixing is included in this items.
32Collecting unserviceable (burnt) exhaust fan of any make any size 250 mm/450 mm sweepfrom E/M yard , transporting to local workshop and back , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewindingwith new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures,varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless runningand refixing the exhaust fan on their respective location (loc of the same received from respective section through complaint slip ) complete all as directed by Engr in charge Note:Bush, bearing, capacitor, andsockets shall be measured and paid for separately as supply only but Collecting & fixing is included in this items.
33Material & labour, Spray painting of ceiling fan 1200/1400 mm sweep and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed by Engr-in-charge.
34Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
35Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.
36Supply only capacitor 2.50/3.15 MFD, 440 Volt AC, 50 Hz PCB Oil filled type complete all as directed.
37Supply only capacitor 4.0 MFD, 440 Volt AC, 50 Hz PCB Oil filled type complete all as directed.
38Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.
39Supply and fix, iron blade for Eaxhaust fansuitable for 300/ 400/ 450mm sweep made out of MS sheet duly painted, complete all as specified and directed.
40Supply and fix in replacement for louvers for existing exhaust fan of any size/ capacity, complete all as specified and directed.
41Winter Appliances
42Taking down electric water heater/ geysers of capacity 35 ltrs site for complete overhauling, de scaling, cleaning of sludge and washed down with the help of spray, with new gasket set assembly, replacement of nuts, bolts and washers as required at site and re-assembling and refixing the same after repair and testing complete all as specified and as directed by Engineer-in-charge.
43Taking down electric water heater/ geysers of capacity 25 ltrs site for complete overhauling, de scaling, cleaning of sludge and washed down with the help of spray, with new gasket set assembly, replacement of nuts, bolts and washers as required at site and re-assembling and refixing the same after repair and testing complete all as specified and as directed by Engineer-in-charge. Note for Item Ser No42 & 43Any damage if ooccured during the process of cleaning the geyser will be made good by contactor at no extra cost.
44S & F in replacement of heating element of 1.5 KW / 2 KW ratingdouble tube typewith cup type of circular /traingle shape includingrubber washerssuitable to fitin the existing geyser without any water leakagecompleteall as specified and as directed by Engr-in-Charge . Make : DASS PASS,Theta.
45S & F apparatus plate (Geysers assembly) suitable for existing Geysers of Cap 25 Litres of copper /brass complete with nuts and bolts and rubber washer complete all as specified and directed. Make:- Bajaj, Havells, CG.
46S & F apparatus plate (Geysers assembly) suitable for existing Geysers of Cap 35 Litres of copper /brass complete with nuts and bolts and rubber washer complete all as specified and directed. Make:- Bajaj, Havells, CG.
47S & F in replacement of GM vertical non return valve 15 mm dia as per site requirement complete, all as specified and as directed by Engr-in-Charge . ISI mark
48S & Fstainless steelinner tank 18 gauge heavy duty in replacement of steel inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing25/35 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
49S & F in replacement the thermostat for the geysers 25/35/50Ltrs capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge .Make DASS PASS/THETA/Bajaj.
50S & F in replacement of safety valve/high pressure valve 15mm,as per site requirement completeall as specified and as directed by Engr-in-Charge . ISI marked.
51S & F in replacement heavy duty braided PVC connecting of PTMT pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixing in position all as approved by Engineer-in-charge.Make :Havells/Prayg.
52S&F in replacement of 1100 Volt grade cable flexible 3 core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm ISI mark Make:-Havells, Anchor, RR Kable.
53S & F in replacementsuitable fastner not less than 100 mm long for geyserincluding making good to disturbed surface of wall and maching existing surface and finishingcomplete all as specified and as directedin Engr – in- Charge.
54S & F in replacement of indicating lamp Red /Green as per Geyser suitability complete all as specified and as directed by Engr In Charge
55M & L for Painting of geyser of cap 25/35/50 ltrs complete at site or in store with super synthetic enamel white paint by spraying including filling cavities with filler, one coat after scraping old paint, cleaning all dust etc complete all as specified an as directed by Engineer -in -charge.
56S&F in replacement metal clad plug top 2 pin 240 volt AC of capacity 15 /20 Amp . Make: Havells /L&T/Standard
57Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit.