All India Institute Of Medical Sciences-AIIMS has published Tender For Proposal Of Civil & Electrical Work With Cable Laying In The Proposed Kendriya Bhandarnear Blood Bank At Aiims Patna.. Submission Date for this Tender is 20-02-2024. Electrical Maintenance Tenders in patna Bihar. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | EARTH WORK Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. |
2 | CEMENT CONCRETE (CAST IN SITU)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
3 | MASONRY WORKBrick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
4 | WOOD AND P. V. C. WORK Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
5 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
6 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm |
7 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
8 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
9 | FINISHING12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
10 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
12 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
15 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
16 | Dismantling and Demolishing Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
17 | ROAD WORKDry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
18 | ALUMINIUM WORKProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
19 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
21 | ELECTRICAL WORKWiringforlightpoint/fanpoint/exhaustfanpoint/callbellpoint with1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecableinsurface/recessedsteelconduit,with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor single core cable etc. as required. Group A |
22 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
23 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
24 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
25 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
26 | Supplyingandfixing20A,240V,SPNIndustrial typesocket outlet,with2poleandearth,metalenclosedplugtop alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
27 | Supplyingandfixingoffollowingwayssurface/recess mounting, verticaltype, 415 V, TPN MCB distribution board of sheetsteel,dustprotected,dulypowderpainted,inclusive of 200Atinnedcopperbusbar,commonneutrallink,earthbar, din bar for mounting MCBs (but without MCBs and incomer ) as required.(Note:VerticaltypeMCBTPDBisnormallyused where 3 phase outlets are required.)8 way (4 + 24), Double door |
28 | Supplyingand fixing 5A to32A rating, 240/415V, 10kA, "C" curve,miniature circuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Single pole (25 Amp) |
29 | Supplyingand fixing 5A to32A rating, 240/415V, 10kA, "C" curve,miniature circuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Single pole (10 Amp) |
30 | Supplyingand fixing 5A to32A rating, 240/415V, 10kA, "C" curve,miniature circuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Triple pole and neutral( 63 Amp) |
31 | Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required.15/16 A switch |
32 | Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required.15/16 A Modular socket outlet |
33 | Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required. 5/6 A Switch |
34 | Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required. 10/6 A modular socket outlet |
35 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
36 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
37 | Laying of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground includingexcavation,sandcushioning,protective coveringand refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm |
38 | LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mmMS flat clamp) |
39 | Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 50 sq. mm (35mm) |
40 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
41 | 3.5 c x 50 sqmm AL/ AR cable |
42 | 18 watt led batten light |
43 | 100 amp MCCB with Box |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy