Rural Development Local Bodies Closing in 0 days TDR #41989154

Annual Plan-Wandoor Grama Panchayath Thrikkaikuth Anganvadi Electrification-S0399/24-General Electrical Work

Issued by Local Bodies · anganvadi, Kerala
Tender Value
1 Lakhs
Estimated cost
Bid Submission
12 Feb 2024
0 days left
EMD
2028
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
anganvadi → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Annual Plan-Wandoor Grama Panchayath Thrikkaikuth Anganvadi Electrification-S0399 / 24-General Electrical Work- 1 Electrical 2 1.10.3:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 3 1.14.1:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 4 1.14.2:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 5 1.14.3:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 6 1.25:Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 7 90.3.20.3:Supply & Installation Of Light Fittings On Tw Round Block Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture 8 Od330861 / 2023-2024:Supply Conveyance, Installation, Testing And Commissioning Of20w Led Flood Light With Ip 65 Protection Led Chip E With Thd Less Than10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenanc 9 Od330862 / 2023-2024:Supply And Fixing12w Ledbulk Head Fittingheat Resistant Prismatic Glass Cover To Wall / Ceiling Including Giving Connections With Required Length Of 16 / 0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss Or Extending The Original Wiringand Making Good The Surface As Required. 10 90.5.1.3:Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650 / 1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell 11 Od330863 / 2023-2024:Supply, Installation Testing And Commissioning Exhaust Fan Of Size 150Mm Sweep Light Duty In Plastic Body With Self Opening Lowers In The Existing Opening, Fixing Necessary Anchor Bolts / Bolt And Nut With 0.3M, 110Mm Pvc Pipe Neatly Plastered Including Making Exhaust Fan Hole If Required, Making Good The Damages, Color Washing Etc As Required And Giving Connection With Required Length Of 24 / 0.20Mm Pvc Insulted And Pvc Sheathed 650 / 1100V Grade 3 Core Round Copper Conductor Flexible Wire 12 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0 ( Cub Meter / Minute / Watt ) , Air Delivery Minimum 210 ( Cubic Meter / Minute ) , Copper Winding Suitable For 230V / 240V Single Phase Ac Supply 13 1.58:Supplying And Fixing Pvc Batten / Angle Holder Including Connection Etc. As Required. 14 Od330864 / 2023-2024:Supply And Fixing Of 9W Led Bulb, As Required 15 1.31:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 16 1.32:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 17 1.56:Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlets And 2 Nos. 5 / 6 A Modular Switches, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 18 1.27.1:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module ( 75Mmx75mm ) 19 90.10.1.2:Supply & Fixing The Following Types / Sizes Of Boxes Suitable For Modular Accessories In Surface / Recess Including Making Good The Damages, Colour Washing Etc As Required ( Rohs Compliant ) 2 Module Moulded Plastic Box On Surface 20 90.10.3.15:Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 32A Dp Switch With Indicator 21 1.24.4:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 22 1.24.5:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 23 1.24.1:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 24 2.3.3:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator12 Way, Double Door 25 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 26 2.14.1:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residualcurrent Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps 27 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 28 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 29 Od330865 / 2023-2024:Supplying And Providing And Fixing 25 Mm X 3 Mm G.I. Strip Earth Lead From The Test Joint To The Earth Plate 30 Od330866 / 2023-2024:Supply, Providing And Fixing 2 X 25 Mm X 3 Mm G.I. Strip Test Joint For Earthing System 31 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 32 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 33 Od330867 / 2023-2024:Supply And Providing 25X6mm Brass Nut And Bolt Etc. As Required. 34 Od330868 / 2023-2024:Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly, Door Interlock And Pad Locking Arrangement Of The Following Ratings On Existing Angle Iron Frame Work Or Directly To Wall Using Necessary Bolts & Nuts, Fixing The Unit To Wall, Making Good The Damages, Colour Washing Etc. Including Giving Necessary Connections As Required 32 A, 230 V, 50 Hz, Spn Sdf Hrc Type 35 Od330869 / 2023-2024:Supply & Installation Of Dust And Vermin Proof, 1 Phase Syntax Meter Board Gs-Mb-3425-Std-Nfand To Fix Kseb Meters, Fuse Units, Ct Etcand To Fix Kseb Meters, Fuse Units, Ct Etc As Required Including Fixing It On Wall, Making Good The Damages Colour Washing Etc. As Required. 36 Od330870 / 2023-2024:Supplying And Fixing32 A, 2 Way Neutral Links Mounted On Dmc / Smc Base With Connections, In Existing Meter Board 37 Od330871 / 2023-2024:Supplying And Fixing32a, Hrc Fuse With Hrc Fuse Link With Connections, In Existing Meter Board 38 Od330872 / 2023-2024:Supplying And Fixing Of Following Sizes Oflight Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall / Ground And Making Good The Same In Case Of Recessed Conduit As Required.32Mm As Service Pipe 39 Od330873 / 2023-2024:Supplying Andproviding M8 Anchor Bolt Hook In Wall / Parapet For Binding Supportservice Wireetc As Required 40 Od330874 / 2023-2024: Charges For Preperation Of Kseb Test Report For Submittingto The Concerned Kseb Section Office

BOQ

Work Name:Annual Plan-Wandoor Grama Panchayath Thrikkaikuth Anganvadi Electrification-S0399/24-General Electrical Work
Sl. No. Item Description
1Electrical
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
31.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
41.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
51.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
61.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
790.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
8OD330861/2023-2024:Supply Conveyance, installation, testing and commissioning of20W LED Flood light with IP 65 protection LED Chip e with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenanc
9OD330862/2023-2024:Supply and fixing12W LEDbulk head fittingheat resistant prismatic glass cover to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiringand making good the surface as required.
1090.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
11OD330863/2023-2024:Supply, installation testing and commissioning exhaust fan of size 150mm sweep Light duty in plastic body with self opening lowers in the existing opening, fixing necessary anchor bolts/bolt and nut with 0.3m,110mm PVC pipe neatly plastered including making exhaust fan hole if required, making good the damages, color washing etc as required and giving connection with required length of 24/0.20mm PVC insulted and PVC Sheathed 650/1100V grade 3 core round copper conductor flexible wire
1290.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
131.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
14OD330864/2023-2024:Supply and fixing of 9W LED Bulb, as required
151.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
161.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
171.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
181.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1990.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
2090.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
211.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
221.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
231.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
242.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
252.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
262.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
272.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
285.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
29OD330865/2023-2024:Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
30OD330866/2023-2024:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
3190.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3290.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
33OD330867/2023-2024:Supply and providing 25x6mm brass nut and bolt etc. as required.
34OD330868/2023-2024:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required 32 A, 230 V, 50 Hz, SPN SDF HRC type
35OD330869/2023-2024:Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board GS-MB-3425-STD-NFand to fix KSEB meters, fuse units, CT etcand to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
36OD330870/2023-2024:Supplying and fixing32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
37OD330871/2023-2024:Supplying and fixing32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
38OD330872/2023-2024:Supplying and fixing of following sizes oflight class PVC conduit along with accessories in surface/ recess including cutting the wall/ground and making good the same in case of recessed conduit as required.32mm as service pipe
39OD330873/2023-2024:Supplying andProviding M8 anchor bolt hook in wall/parapet for binding supportservice wireetc as required
40OD330874/2023-2024: Charges for preperation of KSEB test Report for submittingto the concerned KSEB section office

AI Tender Summary

OUR REF NO 41989154
AUTHORITY Local Bodies
TENDER VALUE 1 Lakhs
LAST DATE 12-02-2024
Authority
Authority Name Grama Panchayat
Work Description Annual Plan-Wandoor Grama Panchayath Thrikkaikuth Anganvadi Electrification-S0399 / 24-General Electrical Work- 1 Electrical 2 1.10.3:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 3 1.14.1:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 4 1.14.2:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 5 1.14.3:Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 6 1.25:Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 7 90.3.20.3:Supply & Installation Of Light Fittings On Tw Round Block Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture 8 Od330861 / 2023-2024:Supply Conveyance, Installation, Testing And Commissioning Of20w Led Flood Light With Ip 65 Protection Led Chip E With Thd Less Than10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenanc 9 Od330862 / 2023-2024:Supply And Fixing12w Ledbulk Head Fittingheat Resistant Prismatic Glass Cover To Wall / Ceiling Including Giving Connections With Required Length Of 16 / 0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss Or Extending The Original Wiringand Making Good The Surface As Required. 10 90.5.1.3:Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650 / 1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell 11 Od330863 / 2023-2024:Supply, Installation Testing And Commissioning Exhaust Fan Of Size 150Mm Sweep Light Duty In Plastic Body With Self Opening Lowers In The Existing Opening, Fixing Necessary Anchor Bolts / Bolt And Nut With 0.3M, 110Mm Pvc Pipe Neatly Plastered Including Making Exhaust Fan Hole If Required, Making Good The Damages, Color Washing Etc As Required And Giving Connection With Required Length Of 24 / 0.20Mm Pvc Insulted And Pvc Sheathed 650 / 1100V Grade 3 Core Round Copper Conductor Flexible Wire 12 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0 ( Cub Meter / Minute / Watt ) , Air Delivery Minimum 210 ( Cubic Meter / Minute ) , Copper Winding Suitable For 230V / 240V Single Phase Ac Supply 13 1.58:Supplying And Fixing Pvc Batten / Angle Holder Including Connection Etc. As Required. 14 Od330864 / 2023-2024:Supply And Fixing Of 9W Led Bulb, As Required 15 1.31:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 16 1.32:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 17 1.56:Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlets And 2 Nos. 5 / 6 A Modular Switches, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 18 1.27.1:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module ( 75Mmx75mm ) 19 90.10.1.2:Supply & Fixing The Following Types / Sizes Of Boxes Suitable For Modular Accessories In Surface / Recess Including Making Good The Damages, Colour Washing Etc As Required ( Rohs Compliant ) 2 Module Moulded Plastic Box On Surface 20 90.10.3.15:Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 32A Dp Switch With Indicator 21 1.24.4:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 22 1.24.5:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 23 1.24.1:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 24 2.3.3:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator12 Way, Double Door 25 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 26 2.14.1:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residualcurrent Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps 27 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 28 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 29 Od330865 / 2023-2024:Supplying And Providing And Fixing 25 Mm X 3 Mm G.I. Strip Earth Lead From The Test Joint To The Earth Plate 30 Od330866 / 2023-2024:Supply, Providing And Fixing 2 X 25 Mm X 3 Mm G.I. Strip Test Joint For Earthing System 31 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 32 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 33 Od330867 / 2023-2024:Supply And Providing 25X6mm Brass Nut And Bolt Etc. As Required. 34 Od330868 / 2023-2024:Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly, Door Interlock And Pad Locking Arrangement Of The Following Ratings On Existing Angle Iron Frame Work Or Directly To Wall Using Necessary Bolts & Nuts, Fixing The Unit To Wall, Making Good The Damages, Colour Washing Etc. Including Giving Necessary Connections As Required 32 A, 230 V, 50 Hz, Spn Sdf Hrc Type 35 Od330869 / 2023-2024:Supply & Installation Of Dust And Vermin Proof, 1 Phase Syntax Meter Board Gs-Mb-3425-Std-Nfand To Fix Kseb Meters, Fuse Units, Ct Etcand To Fix Kseb Meters, Fuse Units, Ct Etc As Required Including Fixing It On Wall, Making Good The Damages Colour Washing Etc. As Required. 36 Od330870 / 2023-2024:Supplying And Fixing32 A, 2 Way Neutral Links Mounted On Dmc / Smc Base With Connections, In Existing Meter Board 37 Od330871 / 2023-2024:Supplying And Fixing32a, Hrc Fuse With Hrc Fuse Link With Connections, In Existing Meter Board 38 Od330872 / 2023-2024:Supplying And Fixing Of Following Sizes Oflight Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall / Ground And Making Good The Same In Case Of Recessed Conduit As Required.32Mm As Service Pipe 39 Od330873 / 2023-2024:Supplying Andproviding M8 Anchor Bolt Hook In Wall / Parapet For Binding Supportservice Wireetc As Required 40 Od330874 / 2023-2024: Charges For Preperation Of Kseb Test Report For Submittingto The Concerned Kseb Section Office
Basic Detail
Tender No TE-JC3-204/24-5
Bidding Type Tender
Location
City anganvadi
State Kerala
Key Dates
Publish Date 02 Feb 2024
Submission Date 12 Feb 2024
Open Date 13 Feb 2024
Finance
Tender Value 1 Lakhs
Tender Fee 555
EMD 2028
Exemption Not Available
Document List
18e1bab5-9564-4627-845a-d295581b3ef7.html
BOQ_1006196.xls
E-PAY.pdf
IPACT.pdf
preliminaryagreement.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 02, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 12, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 13, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

18e1bab5-9564-4627-845a-d295581b3ef7.html

xls

BOQ_1006196.xls

pdf

E-PAY.pdf

pdf

IPACT.pdf

pdf

preliminaryagreement.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders