| 1 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sqm on plan and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | Excavation in trenches n.exc. 1.5 m wide and exc. 1.5 m and n. exc. 3.0 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified and as directed. |
| 3 | Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed. |
| 4 | Removing the excavated soil to a distanceexc 250m and n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 5 | Demolition and breaking up drain pipes(salt glazed ware,AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 100mm dia pipe complete all as specified and as directed. . |
| 6 | All as per item no 5 above but 150 mm dia pipe complete all as specified and as directed.. |
| 7 | All as per item no 5 above but 200 mm dia pipe complete all as specified and as directed. |
| 8 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) for 100mm dia pipe complete all as specified and as directed. |
| 9 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) 150mm dia drain pipecomplete all as specified and as directed. |
| 10 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2(using 40mm graded crushed stone aggregates) 200 mm dia drain pipecomplete all as specified and as directed. |
| 11 | M&L for SWG drain pipe grade \"A\" of100 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and as directed. |
| 12 | M&L for SWG drain pipe grade \"A\" of150 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and as directed. |
| 13 | M&L for SWG drain pipe grade \"A\" of200 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and as directed. |
| 14 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1(using 40mm graded crushed stone aggregates) smooth finished, and reforming benching as required for 100 mm dia SWG pipe complete all as specified and as directed. |
| 15 | All as per item no 14 above but 150mm dia. complete all as specified and as directed. |
| 16 | All as per item no 14 above but 200 mm dia complete all as specified and as directed. |
| 17 | Cleaning of Sewage line of 100mm bore including manholes, gully traps, grease traps etc. upto 1.5 m deep by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley spraying required bleaching powder complete all as specified and as directed. |
| 18 | All as per serial item No. 17 here-in-above but sewage line of 150 mm bore and depth of sewage line upto 1.50m complete all as specified and as directed.. |
| 19 | All as per serial item No. 17 here-in-above but sewage line of 150 mm bore and depth of sewage line upto 3.00m complete all as specified and as directed.. |
| 20 | Cleaning of manholes depth upto 1.5 mtr by removing all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils out side MD landsprying required quantities of bleaching powder and taken out cover slab and reset in the same position after cleaning and testing complete all as specified and as directed. cleaning shall be done either manually or mechanically as required and complete all as specified and as directed. |
| 21 | All as per serial item No. 20.00 here-in-above but depth exceeding 1.5 m and not exc 3 m deep complete all as specified and as directed. |
| 22 | Cleaningof all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100 mm/75 mm dia CI pipe stacks upto 1st Manhole, CI/SGSW pipe between gully trap & 1st Manhole, CI Tee/Door bends etc to maintain internal sewage system in Md/OTM Accn ofthe area under AGE B/R -IISecunderabadwith and including manual/pressure cleaning pump & flexible rods and other necessary equipments complete all as specified and directed .Note : (i) Contractor or his authorised representative will collect such type of complaints from SFC Centre complaint cell of AGE B/R - II at 9.00 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint. (ii) Complaint must be attended within 24 hours of receipt of complaint else recovery of Rs. 100/-per complaint/ per day will be Charged |
| 23 | Demolition of Brick or stone masonry built in cement mortar complete all as specified and as directed.. |
| 24 | M&L forbrick work with Fly Ashbricks built in CM 1:4 straight or curved on plan exceeding 6m mean radius complete all as specified and as directed. |
| 25 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:4)complete all as specified and as directed. |
| 26 | All as per item 25 here-in-above but except stone complete all as specified and as directed. |
| 27 | M&L for raised pointing to random or polygonal rubble uncoursed or brought upto course in CM 1:4 complete all as specified and as directed. |
| 28 | S&F in repairs galvanised two strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including scuring tying at crossing with and provision of galvanisd mild steel wire taples or steel pins complete all as specified and as directed. |
| 29 | Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 30 | M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate ) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4) complete all as specified and as directed. Note:- Reinforcement will be measured and paid separately |
| 31 | S&F MS TMT bars 10 mmdia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 32 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of man holes, septic tank, filter bed etc incl removing of debrie complete all as specified and as directed. |
| 33 | Supply only intergral water proofing compound complete all as specified and as directed. |
| 34 | M&L for rendering 15mm thick in CM 1:4 with WPC on fair faces of brick/concrete finished even and fair without using extra cement complete all as specified and as directed. Note: WPC will be measured and paid separately under relevant item |
| 35 | Cleaning and de-sludging of existing septic tanks/ deep manholes up to 3 metre deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any meansSpraying required quantities of bleaching powder complete (working in foul condition) complete all as specified and as directed. |
| 36 | S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm complete all as specified and as directed.. |
| 37 | S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 75 mm. complete all as specified and as directed. |
| 38 | S&F PVC (SWR) bends 110 mm dia complete all as specified and as directed. |
| 39 | S&F PVC (SWR) junction double,(double T),equal or unequal. 110 mm dia with access door.complete all as specified and as directed. |
| 40 | S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and as directed. |
| 41 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete all as specified and as directed. |
| 42 | S&F for PVC (SWR) gully trap of I25/110 mm dia set and jointing wilh solvent cement complete all as specified and as directed. |
| 43 | Dismantling fencing wire mesh, any type and in any position complete all as specified and as directed. |
| 44 | Dismantling posts/struts (wood, steel or RCC) any section including taking out embedded portion from concrete/brick masonry etc andmaking good disturbed ground incl barbed wire complete all as specified and directed . |
| 45 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard or dence soil complete all as specified and as directed.. |
| 46 | M&L for cement concrete in foundation filling and mass concrete type D2 1:4:8 (using 40mm graded crushed stone aggregate) complete all as specified and as directed.. |
| 47 | S&F mild steel sections for posts and struts in fencing including embedding in concrete and screwing etc. including securing bolts;cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 48 | Supply only Chain link MS galvanised fencing, of any size or type. complete all as specified and as directed. |
| 49 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.complete all as specified and as directed. |
| 50 | M&L for 5 to 10mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed. |
| 51 | M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 52 | Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortarcomplete all as specified and as directed. |
| 53 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level)complete all as specified and as directed. |
| 54 | M & L for 75mm thickPCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and as directed. |
| 55 | M & L for 75mm thickPCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in base/flooring and finishing surface even and smooth without using extra cement complete all as specified and as directed. |
| 56 | M&L for Chequered cement concrete tiles of size 30 cmx 30 cmx 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment and including 20mm thick screed bed with cement mortar 1:6complete all as specified and as directed. |
| 57 | M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS 15658-2006 of 60 mm thickness, M-35 Gradeover 40 mm thick sand cushioncomplete all as specified and as directed. |
| 58 | M&L for PCC type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in copings, plinth courses, bed plates, kerbs incl necessary formwork etc complete all as specified and as directed.. |
| 59 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces finished even and fair complete all as specified and as directed. |
| 60 | M&L for preparation of newly plastered surfaces of wall ie over a coat of cement primer complete all as specified and as directed |
| 61 | M&L forpreparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed |
| 62 | M&L for Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and as directed..Note: Inner girth only shall be measured. |
| 63 | M&L Preparing newly steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primercomplete all as specified and as directed. |